3847QAIR.pdf
PDF 86 KB Posted
- Attached to
- CAD/PAD Initiators, Drogue Gun Carts, Gyro Spin up Gas Generators and Harness Release Cartridges
- Solicitation number
- FA821319R3012
About this file
QAIR
View the file
Other files
| File | Type | Posted |
|---|---|---|
| ADCSOW.doc | DOC document | |
| 0537QAIR.pdf | ||
| ES7034.doc | DOC document | |
| AIRSPEC.docx | DOCX document | |
| 0537JQRS.pdf | ||
| 0537EDL.pdf | ||
| 18-50031-EDL-0552-UPDATE.pdf | ||
| 2801EDL.pdf | ||
| PHSTSOW.pdf | ||
| CADPADMarkingInstrApr2016.doc | DOC document | |
| 3847JQRS.pdf | ||
| IDCombined.pdf | ||
| AirSpecAttachments.pdf | ||
| 0537ID.pdf | ||
| IHCJHCS50031.pdf | ||
| AIRSPEC50032.docx | DOCX document | |
| HRCDROGUEGYROQALI.pdf | ||
| 18-50031-EDL-0548-UPDATE.pdf | ||
| F010528208.pdf | ||
| F013193847.pdf | ||
| EDL.pdf | ||
| ItemDescription.pdf | ||
| 2801QAIR.pdf | ||
| EDLCombined.pdf | ||
| CDRLS.pdf | ||
| GFP.pdf | ||
| 2CDRLS.pdf | ||
| 8208ID.pdf | ||
| 3847EDL.pdf | ||
| 8208EDL.pdf | ||
| SOWOct152013.doc | DOC document | |
| 2801ID.pdf | ||
| CDRL50032.pdf | ||
| CEDHarnessCartIHC.pdf | ||
| 8208QAIR.pdf | ||
| FA821319R3012_______0002.pdf | ||
| FA821319R3012_______0001.pdf | ||
| FA821319R3012.pdf |
Show all 38
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
RECOMMENDED QUALITY ASSURANCE PROVISIONS
AND SPECIAL INSPECTION REQUIREMENTS
1. PR / MIPR NUMBER
2. NATIONAL STOCK NUMBER
1377013193847ES
3. POINT OF INSPECTION
SOURCE DESTINATION
X
SEE DFARS 246.402
4. POINT OF ACCEPTANCE
SOURCE DESTINATION
X
5. ITEM MANAGER / PHONE
Stettler, Lisa S / 801-777-5694
6. EQUIPMENT SPEC / PHONE
JAMES, LASELUTE E / 801-586-9087
7. CONTRACT QUALITY REQUIREMENTS/SPECIAL INSPECTION REQUIREMENTS
CERTIFICATE OF CONFORMANCE
FAR 52.246-15
CONTRACT RESPONSIBILITY
FOR INSPECTION
FAR 52.246-1
STANDARD INSPECTION
FAR 52.246-2,-3,-4,-5 OR -6
AS APPLICABLE TO CONTRACT
X HIGHER LEVEL CONTRACT QUALITY REQUIREMENTS
ISO 9001:2000
COMMERCIAL ITEM INSPECTION
FAR 52.212-4
OTHER (Describe in Block 8)
8. REMARKS
Johnson, Avery SNAME: 31 MAY 2017DATE:
In accordance with AFMCI 23-102, paragraph 14.2.1, the chief engineer has determined source inspection is required for airmunitions procurements. The following statements, submitted by the chief engineer in accordance with FAR 46.402(f), provide further support for source inspection of munitions items: Quality assurance inspection of explosives and munitions items must be completed at the source to reduce the risk of defective or improperly marked explosives reaching the end-user. The safety consequences of a single defective explosive or improperly marked explosive reaching the end-user are very severe. Customers of typical industrial commodities may be able to tolerate a percent defective of 1% - 3%. In the case of explosives procurement, this percent defective may result in the maiming or death of personnel involved in the handling and use of the items. Airmunitions contracts (under $250K) are primarily for delivery of explosive components used in ammunition, precision guided weapons and the ejection seats of combat aircraft. The lives of transportation and combat personnel are directly related to the successful performance these items. Thus, to ensure explosives safety and quality, source inspection is required for this airmunition procurement.
Hancey, Allen RNAME: 21 OCT 2016DATE:
ISO 9001 OR EQUIVALENT WILL BE ACCEPTABLE
8a. OZONE DEPLETING SUBSTANCES (ODS)
X STATEMENT
"I HAVE REVIEWED THE REQUIREMENT, INCLUDING AVAILABLE TECHNICAL DOCUMENTATION, AND BELIEVE THAT IT DOES NOT REQUIRE THE CONTRACTOR USE CLASS I OZONE DEPLETING SUBSTANCES (ODS) IDENTIFIED IN AIR FORCE POLICY, NOR IS IT WRITTEN SO THAT IT CAN
ONLY BE MET BY THE USE OF A CLASS I ODS."
WAIVER (SEE AF FARS 5323)
NOTE: Quality provisions as annotated hereon will not be downgraded without Technical Authority coordination. The Technical Authority must be notified if award selection is made to a new source using Acquisition Method Code (AMC) 3, 4, or 5.
9. QUALITY PRE-AWARD SURVEY
YES NEW SOURCE
X PREVIOUS SOURCEX NO
AFMC PARTICIPATION
RECOMMENDED
10. CODES
A. I&A
B. CQR
G
11. SIGNATURE OF TECHNICAL AUTHORITY
Johnson, Avery S
ORGANIZATION / SYMBOL
AFLCMC / EBHJ
PHONE
801-777-7326 / 777-7326
DATE
31 MAY 2017
Page 1 of 1AFMC FORM 807, 20060111, V1 Version 2Generated by PRPS using Jasper Reports on 07 Jun 2018
File details come from the government source that posted it.