200131_Pre-Bid RFIs_Asbestos Report_Att. 5.pdf
PDF 632 KB Posted
- Attached to
- Initial Site Visit & RFI Responses for WWYK200131 - Repair Chilled Water System, Bldg. 2280
- Solicitation number
- FA813726R0010
About this file
This document is a Polarized Light Microscopy Asbestos Analysis Report prepared by QuanTEM Laboratories for Tinker Air Force Base Civil Engineering. The report analyzes samples collected on June 14, 2022, from Building 2280 West Mechanical Room during a mechanical room renovation project (Project Numbers WWYK190068 and WWYK200131). The analysis was conducted on June 15, 2022, by Benjamin Hill, Assistant Laboratory Manager, using EPA/600/R-93/116 methodology.
The report details the testing results for six samples collected from various building materials within the mechanical room. All samples tested negative for asbestos content. Sample compositions included a homogeneous perlite paint ceiling tile (containing 50% cellulose and 30% glass fiber), layered vinyl floor tile with calcium carbonate, adhesive glue, paint, and fiberboard insulation materials. Non-asbestos fibers identified in the samples included cellulose, glass fiber, perlite, and binder materials, with concentrations ranging from 30% to 90%. The laboratory is NVLAP accredited (Lab Code: 101959-0) and certified for analysis using EPA/600/M4-82-020 and EPA/600/R-93/116 methods. The report confirms that all sampled materials were in acceptable condition upon receipt and that asbestos was not present in any tested samples.
View the file
Other files
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Date Received: 06/14/2022
Project: Mechanical Room Reno
QuanTEM Lab No. 347428
Analyzed By: Benjamin Hill
Methodology: EPA/600/R-93/116
Polarized Light Microscopy Asbestos Analysis Report
Project Location: Bldg. 2280 West Mech Rm
Project Number: WWYK190068; WWYK200131
Account Number: B731
Received By: Baylie Longstreth
Date Analyzed: 06/15/2022
QuanTEM
Sample ID
Client
Sample ID Composition
Color /
Description Asbestos (%)
Non-Asbestos
Fiber (%)
Client: Tinker AFB - Civil Engineering
Laura Duck
Non Fibrous
001 GM220112 Homogeneous Perlite
Paint
Asbestos Not Present 50
Cellulose
Glass FiberCeiling Tile
White
002 GM220113 Layered CaCO3
Vinyl
Asbestos Not Present NA
Floor Tile
Tan/Brown
002a Layered GlueAsbestos Not Present NA
Adhesive
Yellow
002b Layered PaintAsbestos Not Present NA
Paint
Gray
003 GM220114 Layered BinderAsbestos Not Present 90Cellulose
Fiberboard
Brown
003a Layered PerliteAsbestos Not Present 30
Cellulose
Glass FiberInsulation
Brown/Tan
Date of Report
6/15/2022
Benjamin Hill, Assistant Laboratory Manager
QuanTEM is a NVLAP accredited Testing PLM laboratory (Lab Code: 101959-0). This report relates only to the specific items tested.
NVLAP accreditation applies only to analysis performed utilizing EPA/600/M4-82-020 and EPA/600/R-93/116 methods.
This report may not be used to claim product endorsement by NVLAP or any agency of the US Government.
This report may not be reproduced except in full, without the written approval of the laboratory.
Unless otherwise noted, upon receipt the condition of the sample was acceptable for analysis.