200131_Pre-Bid RFIs_Asbestos Report_Att. 5.pdf

PDF 632 KB Posted

Attached to
Initial Site Visit & RFI Responses for WWYK200131 - Repair Chilled Water System, Bldg. 2280
Solicitation number
FA813726R0010
Issued by

About this file

This document is a Polarized Light Microscopy Asbestos Analysis Report prepared by QuanTEM Laboratories for Tinker Air Force Base Civil Engineering. The report analyzes samples collected on June 14, 2022, from Building 2280 West Mechanical Room during a mechanical room renovation project (Project Numbers WWYK190068 and WWYK200131). The analysis was conducted on June 15, 2022, by Benjamin Hill, Assistant Laboratory Manager, using EPA/600/R-93/116 methodology.

The report details the testing results for six samples collected from various building materials within the mechanical room. All samples tested negative for asbestos content. Sample compositions included a homogeneous perlite paint ceiling tile (containing 50% cellulose and 30% glass fiber), layered vinyl floor tile with calcium carbonate, adhesive glue, paint, and fiberboard insulation materials. Non-asbestos fibers identified in the samples included cellulose, glass fiber, perlite, and binder materials, with concentrations ranging from 30% to 90%. The laboratory is NVLAP accredited (Lab Code: 101959-0) and certified for analysis using EPA/600/M4-82-020 and EPA/600/R-93/116 methods. The report confirms that all sampled materials were in acceptable condition upon receipt and that asbestos was not present in any tested samples.

View the file

Other files

Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Date Received: 06/14/2022

Project: Mechanical Room Reno

QuanTEM Lab No. 347428

Analyzed By: Benjamin Hill

Methodology: EPA/600/R-93/116

Polarized Light Microscopy Asbestos Analysis Report

Project Location: Bldg. 2280 West Mech Rm

Project Number: WWYK190068; WWYK200131

Account Number: B731

Received By: Baylie Longstreth

Date Analyzed: 06/15/2022

QuanTEM

Sample ID

Client

Sample ID Composition

Color /

Description Asbestos (%)

Non-Asbestos

Fiber (%)

Client: Tinker AFB - Civil Engineering

Laura Duck

Non Fibrous

001 GM220112 Homogeneous Perlite

Paint

Asbestos Not Present 50

Cellulose

Glass FiberCeiling Tile

White

002 GM220113 Layered CaCO3

Vinyl

Asbestos Not Present NA

Floor Tile

Tan/Brown

002a Layered GlueAsbestos Not Present NA

Adhesive

Yellow

002b Layered PaintAsbestos Not Present NA

Paint

Gray

003 GM220114 Layered BinderAsbestos Not Present 90Cellulose

Fiberboard

Brown

003a Layered PerliteAsbestos Not Present 30

Cellulose

Glass FiberInsulation

Brown/Tan

Date of Report

6/15/2022

Benjamin Hill, Assistant Laboratory Manager

QuanTEM is a NVLAP accredited Testing PLM laboratory (Lab Code: 101959-0). This report relates only to the specific items tested.

NVLAP accreditation applies only to analysis performed utilizing EPA/600/M4-82-020 and EPA/600/R-93/116 methods.

This report may not be used to claim product endorsement by NVLAP or any agency of the US Government.

This report may not be reproduced except in full, without the written approval of the laboratory.

Unless otherwise noted, upon receipt the condition of the sample was acceptable for analysis.