Attachment 13 - B1655 _E-110_ Addendum01(RFI006).pdf
PDF 471 KB Posted
- Attached to
- Repair/Renovate LO_Sheet Metal_Bldg 1655
- Solicitation number
- FA6675R24R0004
About this file
This document appears to be an attachment related to a Request for Information (RFI) for a federal construction contract opportunity. The key details are:
The U.S. Air Force is requesting proposals for the renovation and repair of Air Force Low Observable (LO), Metals Tech, and Structures Shops Building #1655. The requirement includes demolition, construction, renovation, and related work per the provided A&E drawings and specifications. The construction includes civil, architectural, mechanical, and electrical components. This is a 100% small business set-aside with an estimated contract value between $5-10 million under NAICS code 236220. The solicitation will be issued on SAM.gov, with a site visit on 07/25/2024, RFI deadline of 08/05/2024, and proposal due date of 08/19/2024. The contract will be a single-award, firm-fixed-price type using a lowest-price technically acceptable source selection approach.
View the file
Other files
Show all 22
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
O C
O C
O C
OC OC
OC
G F
GF GF *
O C
O C O
C
O C
J J
J J J
J
J J
J J
JJ J
J
J J
J
J J
J
J J
J
J J
J
J
SHOP WORK
AREA
MT/A
CNC
LOASM
CLEAN ROOM
MECHANICAL
ROOM
MEN
MEN
108-2
WOMEN
107-1
WOMEN
EXISTING
CORRIDOR
DECON
AIR SHWR
VEST
LOCKER
COMM
JAN
WOMEN'S
LOCKER
MEN'S LOCKER
PARTS CAGE
TOOL CRIB
OFFICE
TRAINING
MAIN SHOP
TLT
MDP2
MDP
MDPSE
MRP1A: 2
MRP1A: 2
MRP1A: 2 MRP1A: 2
MRP1A: 2
MRP1A: 2
MRP1A: 3
MRP1A: 3
MRP1A: 3
MPP1A
MRP1A
MRP1A: 4
MRP1A: 4
MRP1A: 4 MRP1A: 4
MRP1A: 4MRP1A: 4
XFMR 1A
MRP1A: 8
MRP1A: 8
MRP1A: 8
MRP1A: 8
MRP1A: 7
MRP1A: 7
MRP1A: 7
MRP1A: 7
MRP1A: 7
MRP1A: 7
MRP1A: 5
MRP1A: 5
MRP1A: 5
MRP1A: 5
MRP1A: 5 MRP1A: 6
MRP1A: 6
MRP1A: 6
MRP1A: 6
MRP1A: 6
MRP1A: 10
MRP1A: 10
MRP1A: 10
MRP1A: 10
E40 E34
E28
E39
E35
E51 E26
E48
E48
E46 E32
E45 E44
E47 E44
E31E29
E53
E33
E37
E27
E27
E30 E36 E03 E01 E04
E02
E06
E07
E33
MDP1A
UTILITY XFMR
GF
GF
GF
GF
GF
GF
LDP1A
MRP1A: 64,66
MRP1A: 67,69
MRP1A: 60
MRP1A: 62
MRP1A: 9
MRP1A: 9
MRP1A: 9
MRP1A: 9
MRP1A: 9
MRP1A: 9
E-110
MRP1A: 11
MRP1A: 11
MRP1A: 11
M R
P A
MRP1A: 11
M R
P A
GF
1 3 4 5 6 7
B
D
A
C
E
8 9
MRP1A: 71
MRP1A: 72
D
RP-TR
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T
E D
B Y
P L O
T S
C A
L E
IS
S U
E D
A T
E
D A
T E
C O
N T
R A
C T
N O
A N
S I
D
F A
F
A F
R C
C o n tr a c ti n g
L y o n s D r.
N
A S
J R
B
F o rt W o rt h T
X
B L
O S
H O
P
D E
S
IG
N
SHEET
NUMBER
H D
R E
N G
IN
E
E R
IN
G
IN
C
N
W L
O O
P
S
U
IT
E
S A
N A
N T
O N
IO
T E
X A
S
T e x a s P
.E
F ir m R e g is tr a ti o n
N o
F -7
H D
R
A S
N O
T E
D
F A
D
F A
C
E
A W
KEYPLAN
PLAN NORTH
IS
S
U E
D F
O R
C O
N S
T R
U C
T
IO
N
IS
S
U E
D F
O R
C O
N S
T R
U C
T
IO
N
/2
/2
T
R
P O
W E
R P
L A
N
E-110
/2
/2
P N
P N
J K
3/32" = 1'-0"1
FIRST FLOOR POWER PLAN
GENERAL NOTES
1. FULLY COORDINATE THE INSTALLATION OF ALL ELECTRICAL
DEVICES WITH THE WORK OF OTHER TRADES.
2. FULLY COORDINATE THE LOCATION OF ALL HVAC EQUIPMENT
WITH THE MECHANICAL AND CONTROLS CONTRACTORS.
PROVIDE ALL DEVICES (I.E. STARTERS, SWITCHES, CONTACTS,
ETC.) REQUIRED TO ENSURE SATISFACTORY OPERATION OF ALL
SYSTEMS AND EQUIPMENT. (LOW VOLTAGE CONTROL WIRING
TO BE PROVIDED BY MECHANICAL CONTRACTOR.) COORDINATE
DEVICE REQUIREMENTS WITH ACTUAL EQUIPMENT INSTALLED
AND MECHANICAL PLANS. WHERE STARTERS AND CONTROLS
ARE NOT SHOWN ON MECHANICAL PLANS AS PROVIDED BY
EQUIPMENT VENDOR, THEY SHALL BE PROVIDED BY ELECTRICAL
CONTRACTOR.
3. FOR ALL HVAC CONTROL DEVICES PROVIDED BY THE
ELECTRICAL CONTRACTOR, PROVIDE ALL NECESSARY AUXILIARY
COMPONENTS AND CONTRACTS TO ENSURE PROPER SYSTEM
CONTROL FUNCTIONS. FULLY COORDINATE ALL REQUIREMENTS
WITH THE MECHANICAL AND CONTROLS CONTRACTORS.
4. SEAL AROUND ALL CONDUIT AND CABLE PENETRATIONS
THROUGH WALLS, CEILINGS AND FLOORS TO MAINTAIN CODE
REQUIRED RATINGS. REFER TO ARCHITECTURAL DRAWINGS
FOR ADDITIONAL INFORMATION.
5. PROVIDE FULLY EQUIPPED PANELBOARDS WITH 20/1 CIRCUIT
BREAKERS FOR ALL LIGHTING AND APPLIANCE PANELBOARDS.
6. SEE MECHANICAL PLANS FOR LOCATION OF ALL MECHANICAL
EQUIPMENT AND INSTALL PER ELECTRICAL EQUIPMENT
SCHEDULE.
7. PROVIDE DEDICATED 120-VOLT CIRCUITS TO ALL HVAC CONTROL
PANELS. UTILIZE EXISTING SPARE 20/1 CIRCUIT BREAKER IN
NEAREST PANEL.
8. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE
CONNECTION OF ALL CONTROLS AND WIRING 100V AND
GREATER. ALL LOW VOLTAGE CONTROLS, LESS THAN 100V,
SHALL BE THE RESPONSIBILITY OF THE CONTROLS
MANUFACTURER.
9. PROVIDE RECEPTACLE AND/OR DATA CONNECTION(S) FOR ALL
SPECIAL SYSTEMS. COORDINATE FINAL MOUNTING HEIGHT(S)
AND LOCATION(S) WITH OWNER.
10. LOCATE JUNCTION BOX AS REQUIRED BY EQUIPMENT ROUGH-IN
REQUIREMENTS.
##KEYNOTES
MACHINE SHOP EQUIPMENT SCHEDULE
EQUIP. NO. DESCRIPTION VOLTAGE PHASE AMPS PANEL CIRCUIT NUMBER CB SIZE POLE BRANCH WIRING CONDUIT CONNECTION TYPE MOUNTING
LOCAL
DISCONNECT
E01 POWER DIMPLER 120 V 1 4 A MRP1A 1 20A 1 2#12 & 1#12G 3/4" 5-20R DROP CORD --
E02 BELT SANDER 120 V 1 8 A MRP1A 33 20A 1 2#12 & 1#12G 3/4" 5-20R DROP CORD --
E03 DRILL PRESS 208 V 3 5 A MRP1A 34,36,38 20A 3 3#12 & 1#12G 3/4" HARDWIRED DROP CORD 30A/240V/3P/NON-FUSED/NEMA1
E04 POWER ROLLER 208 V 1 9 A MRP1A 35,37 20A 2 2#12 & 1#12G 3/4" HARDWIRED DROP CORD 30A/240V/2P/NON-FUSED/NEMA1
E06 FLARING MACHINE AND TOOLBOX 208 V 1 9 A MRP1A 39,41 20A 2 2#12 & 1#12G 3/4" HARDWIRED DROP CORD 30A/240V/2P/NON-FUSED/NEMA1
E07 BAND SAW 480 V 3 5 A MPP1A 14,16,18 20A 3 3#12 & 1#12G 3/4" HARDWIRED DROP CORD 30A/600V/3P/NON-FUSED/NEMA1
E26 ACCURSHEAR 480 V 3 18 A MPP1A 19,21,23 30A 3 3#10 & 1#10G 3/4" HARDWIRED DROP CORD 30A/600V/3P/NON-FUSED/NEMA1
E27 SUNNEN HONING MACHINE 120 V 1 7 A MRP1A 40 20A 1 2#12 & 1#12G 3/4" 5-20R WALL --
E27 SUNNEN HONING MACHINE 120 V 1 7 A MRP1A 42 20A 1 2#12 & 1#12G 3/4" 5-20R WALL --
E28 CARBIDE GRINDER 120 V 1 3 A MRP1A 43 20A 1 2#12 & 1#12G 3/4" 5-20R WALL --
E29 PIRANHA METAL WORKER 208 V 3 8 A MRP1A 44,46,48 20A 3 3#12 & 1#12G 3/4" HARDWIRED DROP CORD 30A/240V/3P/NON-FUSED/NEMA1
E30 BRIDGEPORT MILL 208 V 3 24 A MRP1A 45,47,49 30A 3 3#10 & 1#10G 3/4" HARDWIRED DROP CORD 30A/240V/3P/NON-FUSED/NEMA1
E31 HORIZONTAL BAND SAW 208 V 3 24 A MRP1A 50,52,54 30A 3 3#10 & 1#10G 3/4" HARDWIRED DROP CORD 30A/240V/3P/NON-FUSED/NEMA1
E32 PEDESTAL GRINDER 208 V 3 24 A MRP1A 51,53,55 30A 3 3#10 & 1#10G 3/4" HARDWIRED DROP CORD 30A/240V/3P/NON-FUSED/NEMA1
E33 MACHINE LATHE 208 V 3 45 A LDP1A 2,4,6 60A 3 3#6 & 1#8G 1-1/4" HARDWIRED FROM ABOVE 60A/240V/3P/NON-FUSED/NEMA1
E33 MACHINE LATHE 208 V 3 45 A LDP1A 7,9,11 60A 3 3#6 & 1#8G 1-1/4" HARDWIRED FROM ABOVE 60A/240V/3P/NON-FUSED/NEMA1
E34 HAAS CNC MILL 208 V 3 45 A LDP1A 8,10,12 60A 3 3#6 & 1#8G 1-1/4" HARDWIRED WALL 60A/240V/3P/NON-FUSED/NEMA1
E35 HAAS CNC LATHE ST-30Y 480 V 3 21 A MPP1A 20,22,24 30A 3 3#10 & 1#12G 1" HARDWIRED WALL 30A/600V/3P/NON-FUSED/NEMA1
E36 KONDIA MILL 480 V 3 21 A MPP1A 25,27,29 30A 3 3#10 & 1#12G 1" HARDWIRED DROP CORD 30A/600V/3P/NON-FUSED/NEMA1
E37 SURFACE GRINDER 480 V 3 42 A MDP1A 20,22,24 60A 3 3#8 & 1#10G 1-1/4" HARDWIRED WALL 60A/600V/3P/NON-FUSED/NEMA1
E39 HAAS CNC LATHE TL-1 208 V 1 30 A MRP1A 63,65 40A 2 2#8 & 1#12G 1" HARDWIRED WALL 60A/240V/2P/NON-FUSED/NEMA1
E40 HAAS CNC LATHE VR8 208 V 1 48 A LDP1A 19,21 70A 2 2#8 & 1#8G 1" HARDWIRED WALL 100A/240V/2P/NON-FUSED/NEMA1
E44 PLASMA MANUAL/CNC 208 V 3 65 A LDP1A 14,16,18 100A 3 3#6& 1#8G 1-1/4" HARDWIRED DROP CORD 100A/240V/3P/NON-FUSED/NEMA1
E44 PLASMA MANUAL/CNC 208 V 3 65 A LDP1A 13,15,17 100A 3 3#6& 1#8G 1-1/4" HARDWIRED DROP CORD 100A/240V/3P/NON-FUSED/NEMA1
E45 DOWN DRAFT TABLE 208 V 1 12 A MRP1A 73,75 20A 2 2#12 & 1#12G 3/4" HARDWIRED DROP CORD 30A/240V/2P/NON-FUSED/NEMA1
E46 MIG WELDER A 208 V 3 19 A MRP1A 57,59,61 30A 3 3#10& 1#10G 3/4" HARDWIRED DROP CORD 30A/240V/3P/NON-FUSED/NEMA1
E47 MIG WELDER B 208 V 1 34 A MRP1A 56,58 50A 2 2#10 & 1#10G 3/4" HARDWIRED WALL 60A/240V/2P/NON-FUSED/NEMA1
E48 TIG/STICK WELDER 480 V 3 35 A MDP1A 14,16,18 60A 3 3#8 & 1#10G 1" HARDWIRED WALL 60A/600V/3P/NON-FUSED/NEMA1
E48 TIG/STICK WELDER 480 V 3 35 A MDP1A 19,21,23 60A 3 3#8 & 1#10G 1" HARDWIRED WALL 60A/600V/3P/NON-FUSED/NEMA1
E51 HEAT TREAT OVEN 480 V 3 36 A MDP1A 13,15,17 60A 3 3#4 & 1#8G 1-1/4" HARDWIRED, GFCI BREAKER WALL 60A/600V/3P/NON-FUSED/NEMA1
E53 OMAX WATERJET 55100 480 V 3 76 A MDP1A 8,10,12 100A 3 3#2, 1#8G 1-1/4" HARDWIRED WALL 100A/600V/3P/NON-FUSED/NEMA1
1/4" = 1'-0"2
ENLARGED POWER PLAN -
TELECOMMUNICATIONS ROOM
1. 120V, 1PH DEDICATED CIRCUIT FOR FIRE ALARM NAC PANEL.
2. NEMA 5-20R OUTLET FOR WASHER AND NEMA 14-30R OUTLET
FOR DRYER. COORDINATE MOUNTING HEIGHT WITH
ARCHITECTURAL PLANS.
3. 120/240V, 100A, 1PH PANELBOARD WITH 20 SPACES.
4. 240V, 1PH TWIST-LOCK RECEPTACLE FOR MULTI-OUTLET
POWER STRIP IN RACK. TWIST-LOCK RECEPTACLE SHALL BE
INSTALLED ABOVE RACK, MOUNTED TO TELECOM CABLE
TRAY.
5. 120V, 1PH TWIST-LOCK RECEPTACLE FOR MULTI-OUTLET
POWER STRIP IN RACK. TWIST-LOCK RECEPTACLE SHALL BE
INSTALLED ABOVE RACK, MOUNTED TO TELECOM CABLE
TRAY.
6. ALL LOADS IN TELECOMMUNICATIONS ROOM (EXCEPT
LIGHTING) SHALL BE FED FROM DEDICATED 120/240V
PANELBOARD.
7. PROVIDE HOUSEKEEPING PAD FOR TRANSFORMER.
8. 480V, 3PH, 6.9FLA POWER CONNECTION FOR AIR SHOWER.
MOTOR STARTER WITH ELECTRONIC OVERLOADS LOCATED
INSIDE CONTROL PANEL. PROVIDE DISCONNECT SWITCH
MOUNTED ON THE FACE OF THE ELECRICAL CONTROL PANEL.
PROVIDE (1) 3 - #12, 1 - #12G IN 3/4"C.
A
D D
E N
D U
M
R
F I
/2 /2
26 Aug 2024
| Sheets |
| E-110 - POWER PLAN |
File details come from the government source that posted it. Updated .