1. There will be a need for approximately 1,800 Linear Feet (LF) of single mode OSP fiber to connect from Building 1344 to Building 1251.
2. There will be a need for approximately 750 LF of 4" Schedule 40 PVC conduit with 3 cell MaxCell innerduct to tie into the existing hand hole that sits just east of Building 1251 across Military Parkway and possibly the need for one additional hand hole to match the existing hand holes on the installation which would be 30"W x 48"L x 36"D. Note: This is a rough estimate as the network cable engineers for Carswell were not available to complete a survey.