FA6675-15-R-0006_B1344_Solicitation_Amendment__4.pdf

PDF 38 KB Posted

Attached to
B1344 RENOVATIONS Solicitation # FA6675-15-R-0006
Solicitation number
FA6675-15-R-0001
Issued by

About this file

FA6675-15-R-0006 B1344 Renovations Amendment 4 dated 1 Sep 2015

View the file

Other files

File Type Posted
RFI_0006AIP_B1344_20150831.pdf PDF
FA6675-15-R-0006_B1344_CATM_Renovations_SOW_03302015_Rev_4_08312015.pdf PDF
1344_-_301_CATAM_-_HVAC_Installation_Plan.pdf PDF
FA6675-15-R-0006_0003_B1344_Amendment__3.pdf PDF
FA6675-15-R-0006_B1344_CATM_Renovations_SOW_03302015_Rev_3_08252015.pdf PDF
1344_-_301_CATAM_-_Electrical_Power_Plan.pdf PDF
RFI_0002IES_20150822.pdf PDF
RFI_0003IES_20150822.pdf PDF
RFI_0001IES_20150822.pdf PDF
RFI_0001MCI_20150817-signed.pdf PDF
RFI_0003AIP_20150812-signed.pdf PDF
RFI_0005DME_20150818.pdf PDF
RFI_0004AIP_20150812.pdf PDF
RFI_0002AIP_20150812-Signed.pdf PDF
FA6675-15-R-0006_B1344_Solicitation_Amendment_0002.pdf PDF
RFI_0003DME_20150804-signed.pdf PDF
RFI_0004DME_20150811-signed.pdf PDF
RFI_0002DME_20150804.pdf PDF
RFI_0001DME_20150804.pdf PDF
1344_-_301_CATAM_-_Plumbing_Work_Required.pdf PDF
1344_-_301_CATAM_-_Lighting_Installation_Plan.pdf PDF
1344_-_301_CATAM_-_Plumbing_DEMO_Plan.pdf PDF
FA6675-15-R-0006_B1344_CATM_Renovations_SOW_03302015_Rev_2-1_08032015.pdf PDF
FA6675-15-R-0006_B1344_CATM_Renovations_SOW_03302015_Rev08032015.pdf PDF
B1344_Current_Exterior_Dimensions.pdf PDF
B1344_Interior_Dimensions_Post_Construction.pdf PDF
FA6675-15-R-0006_B1344_CATM_Renovations_SOW_03302015_Rev06172015.pdf PDF
B1344_Existing_Concrete_Dimensions.pdf PDF
B1344_Electrical_Power_Plan.pdf PDF
B1344_Ceiling_Demo_Plan.pdf PDF
FA6675-15-R-0006_B1344_Solicitation_Amendment_0001.pdf PDF
B1344_Comm_Plan.pdf PDF
WD_TX150322_03062015_TX322.pdf PDF
B1344_HVAC_Demo_Plan_Model_2.pdf PDF
B1344_Concrete_Work_Required.pdf PDF
B1344_Flooring_Install.pdf PDF
B1344_Exterior_Dimensions_Post_Construction.pdf PDF
B1344_Ceiling_Install.pdf PDF
B1344_Lighting_Demo_Plan.pdf PDF
B1344_Rm_102_Millwork.pdf PDF
B1344_Electrical_Demo_Plan.pdf PDF
B1344_HVAC_Installation_Plan.pdf PDF
B1344_Current_Interior_Dimensions.pdf PDF
B1344_Fire_Suppression_Install.pdf PDF
B1344_Current_Fire_Suppression.pdf PDF
FA6675-15-R-0006_B1344_CATM_Solicitation.pdf PDF
RFI_-RFC_FORM_20150420.doc DOC document
B1344_HVAC_Demo_Plan_Model_1.pdf PDF
Show all 48

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

301ST CONF/LGC - RONALD PYLES

1776 CARSWELL AVE

NAS JRB

FORT WORTH TX 76127

DDPM 16-0001

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER (Type or print)

30-105-04EXCEPTION TO SF 30

APPROVED BY OIRM 11-84

STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA

FAR (48 CFR) 53.243

The purpose of this amendment is to a) Revise the Statement of Work, b) Revise the HVAC Installation Plan draw ing and c) Extend the proposal due date to 4 Sep 2015 @ 1000 AM Central to allow time for proposal preparation.

1. CONTRACT ID CODE PAGE OF PAGES

J 1 4

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

16C. DATE SIGNED

BY 01-Sep-2015

16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR

(Signature of Contracting Officer)(Signature of person authorized to sign)

8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X FA6675-15-R-0006

X 9B. DATED (SEE ITEM 11)

24-Jun-2015

10B. DATED (SEE ITEM 13)

9A. AMENDMENT OF SOLICITATION NO.

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer X is extended, is not extended.

Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:

(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (If required)

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE

CONTRACT ORDER NO. IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

10A. MOD. OF CONTRACT/ORDER NO.

2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)

6. ISSUED BY

3. EFFECTIVE DATE

01-Sep-2015

CODE

301ST CONF/LGC

1776 CARSWELL AVE

NAS JRB

FT. WORTH TX 76127-6200

FA6675 7. ADMINISTERED BY (If other than item 6)

4. REQUISITION/PURCHASE REQ. NO.

CODE FA6675

FACILITY CODECODE

EMAIL:TEL:

FA6675-15-R-0006

SECTION SF 30 BLOCK 14 CONTINUATION PAGE

SUMMARY OF CHANGES

SECTION A - SOLICITATION/CONTRACT FORM

The required response date/time has changed from 02-Sep-2015 01:00 PM to 04-Sep-2015 10:00 AM.

SECTION J - LIST OF DOCUMENTS, EXHIBITS AND OTHER ATTACHMENTS

The Table of Contents has changed from:

Exhibit/Attachment Table of Contents

DOCUMENT TYPE DESCRIPTION PAGES DATE

Attachment 1 Revised SOW B1344

Renovation

25-AUG-2015

Attachment 10 1344 - 301 CATAM - HVAC DEMO Model (2)

1 19-JUN-2015

Attachment 11 1344 - 301 CATAM - HVAC DEMO Model (1)

1 19-JUN-2015

Attachment 12 1344 - 301 CATAM - Flooring Installation Plan

- CADD Model (

1 19-JUN-2015

Attachment 13 1344 - 301 CATAM - Fire Install Model (1)

1 19-JUN-2015

Attachment 14 1344 - 301 CATAM - Fire DEMO Model (1)

1 19-JUN-2015

Attachment 15 1344 - 301 CATAM - Exterior DIM Post Construction Model (1)

1 19-JUN-2015

Attachment 16 1344 - 301 CATAM - Exterior DIM Model (1)

1 19-JUN-2015

Attachment 17 1344 - 301 CATAM - Existing Concrete Model (1)

1 19-JUN-2015

Attachment 18 1344 - 301 CATAM - Electrical Power Plan Model (1)

1 19-JUN-2015

Attachment 19 1344 - 301 CATAM - Electrical DEMO Model (1)

1 19-JUN-2015

Attachment 2 GD WD NO TX150322

20150306 TX322

6 06-MAR-2015

Attachment 20 1344 - 301 CATAM - Concrete Work Required Model (1)

1 19-JUN-2015

Attachment 21 1344 - 301 CATAM - Ceiling Demo Plan - CADD Layout2 (1)

1 19-JUN-2015

Attachment 22 1344 - 301 CATAM - Ceiling Construction Plan

- CADD Model (1

1 19-JUN-2015

Attachment 23 B1344 Electrical Power

Plan Attachment 3 1344 - Schedule of

Materials - DDPM 160001

1 19-JUN-2015

Attachment 4 1344 - Drawing - Millwork - DDPM 160001

1 19-JUN-2015

Attachment 5 1344 - Drawing - COMM Plan

1 19-JUN-2015

Attachment 6 1344 - 301 CATAM - Lighting DEMO Model (1)

1 19-JUN-2015

Attachment 7 1344 - 301 CATAM - Interior DIM Post Construction Model (1)

1 19-JUN-2015

Attachment 8 1344 - 301 CATAM - Interior DIM Model (1)

1 19-JUN-2015

Attachment 9 1344 - 301 CATAM - HVAC Installation Plan Model (1)

1 19-JUN-2015

to:

Exhibit/Attachment Table of Contents

DOCUMENT TYPE DESCRIPTION PAGES DATE

Attachment 1 SOW Rev 4 31-AUG-2015 Attachment 10 1344 - 301 CATAM -

HVAC DEMO Model (2)

1 19-JUN-2015

Attachment 11 1344 - 301 CATAM - HVAC DEMO Model (1)

1 19-JUN-2015

Attachment 12 1344 - 301 CATAM - Flooring Installation Plan

- CADD Model (

1 19-JUN-2015

Attachment 13 1344 - 301 CATAM - Fire Install Model (1)

1 19-JUN-2015

Attachment 14 1344 - 301 CATAM - Fire DEMO Model (1)

1 19-JUN-2015

Attachment 15 1344 - 301 CATAM - Exterior DIM Post Construction Model (1)

1 19-JUN-2015

Attachment 16 1344 - 301 CATAM - Exterior DIM Model (1)

1 19-JUN-2015

Attachment 17 1344 - 301 CATAM - Existing Concrete Model (1)

1 19-JUN-2015

Attachment 18 1344 - 301 CATAM - Electrical Power Plan Model (1)

1 19-JUN-2015

Attachment 19 1344 - 301 CATAM - Electrical DEMO Model (1)

1 19-JUN-2015

Attachment 2 GD WD NO TX150322

20150306 TX322

6 06-MAR-2015

Attachment 20 1344 - 301 CATAM - Concrete Work Required Model (1)

1 19-JUN-2015

Attachment 21 1344 - 301 CATAM - Ceiling Demo Plan - CADD Layout2 (1)

1 19-JUN-2015

Attachment 22 1344 - 301 CATAM - Ceiling Construction Plan

- CADD Model (1

1 19-JUN-2015

Attachment 23 B1344 Electrical Power Plan

Attachment 3 1344 - Schedule of Materials - DDPM 160001

1 19-JUN-2015

Attachment 4 1344 - Drawing - Millwork - DDPM 160001

1 19-JUN-2015

Attachment 5 1344 - Drawing - COMM Plan

1 19-JUN-2015

Attachment 6 1344 - 301 CATAM - Lighting DEMO Model (1)

1 19-JUN-2015

Attachment 7 1344 - 301 CATAM - Interior DIM Post Construction Model (1)

1 19-JUN-2015

Attachment 8 1344 - 301 CATAM - Interior DIM Model (1)

1 19-JUN-2015

Attachment 9 Revised HVAC Installation Plan drawing

31-AUG-2015

(End of Summary of Changes)

File details come from the government source that posted it. Updated .