ASHE__11-1091_CCEB_REV.1.xls
XLS spreadsheet 783 KB Posted
- Attached to
- ASHE 11-1091 CONSTRUCT ADDITION REPAIR CORROSION CONTROL FAC. 9109 AND DEMO FAC. 973 and 974
- Solicitation number
- FA568218R0031
About this file
ASHE 11-1091 Cost Estimate Breakdown REV.1
View the file
Other files
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
NEW 9109.
| CONSTRUCTION COST ESTIMATE BREAKDOWN | |||||||||||||
| CONTRACTOR | ADDRESS | ||||||||||||
| CONTRACT FOR (Work to be performed) | PROPOSED TOTAL CONTRACT PRICE | ||||||||||||
| CONSTRUCT ADDITION REPAIR CORROSION CONTROL FAC. 9109 AND DEMO FAC.973 AND 974, AREA F, AVIANO AB, ITALY. | |||||||||||||
| PURCHASE REQUEST NUMBER | PROJECT NUMBER | WORK LOCATION | |||||||||||
| ASHE 11-1091 REV.1 | FAC.9109 and 9110, AREA F, AVIANO AIR BASE, ITALY | ||||||||||||
| MATERIAL COSTS | LABOR COSTS | ||||||||||||
| LINE NO. | ITEM | UNIT OF MEASURE | QUANTITY | UNIT | TOTAL | MANHOURS MANDAYS | AVERAGE RATE | TOTAL | OTHER DIRECT COSTS | LINE TOTAL | |||
| (1) | (2) | (3) | (4) | (5) | (6) | (7) | (8) | (9) | (10) | ||||
| FAC. 9109 PART. A - NEW CONSTRUCTION / Nuova Costruzione | |||||||||||||
| FAC.9109 PART I - DEMOLITIONS, EXCAVATIONS AND REMOVALS / Parte I - Demolizioni, Scavi e Rimozioni | |||||||||||||
| FAC. 9109 Ia Architectural Work - Ia Lavori Architettonici | |||||||||||||
| 1 | Metal Door Removal | ||||||||||||
| Rimozione Porte in Metallo | IT. No. Art. n. | 1 | Ea./No. | 2.00 | |||||||||
| Total Architectural Work - Totale Lavori Architettonici | |||||||||||||
| FAC.9109 Ib Structural Work - Ib Lavori Strutturali | |||||||||||||
| 2 | CONCRETE PAD DEMOLITION Demolizione Piazzola in c.a. | IT. No. Art. n. | 1 | LS/AC | 1.00 | ||||||||
| 3 | EXCAVATION FOR FOUNDATIONS | ||||||||||||
| Scavo per Fodazioni in c.a. | IT. No. Art. n. | 2 | m3 | 90.00 | |||||||||
| Total Structural Work - Totale Lavori Strutturali | |||||||||||||
| FAC.9109 Ic Civil Work - Ic Lavori Civili | |||||||||||||
| 4 | UNDERGROUND UTILITIES DEMOLITION | ||||||||||||
| Demolizione sottoservizi | IT. No. Art. n. | 1 | LS/AC | 1.00 | |||||||||
| 5 | EXCAVATION FOR NEW SUB-BASE | ||||||||||||
| Scavo sbancamento | IT. No. Art. n. | 2 | m3 | 170.00 | |||||||||
| Total Civil Work - Totale Lavori Civili | |||||||||||||
| FAC.9109 Id Mechanical Work - Id Lavori Meccanici | |||||||||||||
| 6 | EXCAVATION FOR UNDERGROUND PIPES | ||||||||||||
| Scavo per tubazioni interrate. | IT. No. Art. n. | 1 | LS/AC | 1.00 | |||||||||
| Total Mechanical Work - Totale Lavori Meccanici | |||||||||||||
| FAC. 9109 Ie Electrical Work - Ie Lavori Elettrici | |||||||||||||
| 7 | REMOVAL EXISTING ELECTRICAL SYSTEM | ||||||||||||
| rimozione impianto elettrico esistente | IT. No. Art. n. | 1 | LS/AC | 1.00 | |||||||||
| Total Electrical Work - Totale Lavori Elettrici | |||||||||||||
| TOTAL PART I - Totale Parte I | |||||||||||||
| FAC. 9109 PART IIa - ARCHITECTURAL, STRUCTURAL AND CIVIL WORK / Parte IIa - Lavori Architettonici, Strutturali e Civili | |||||||||||||
| IIa Architectural Work - Ia Lavori Architettonici | |||||||||||||
| 8 | CONCRETE LECA BLOCK WALLS | ||||||||||||
| Muratura in Mattone in cls LECA | IT. No. Art. n. | 1 | m2 | 75.00 | |||||||||
| 9 | INDUSTRIAL CONCRETE FLOOR | ||||||||||||
| Pavimento industriale in cls | IT. No. Art. n. | 2 | m2 | 200.00 | |||||||||
| 10 | 8/10 mm THICK STEEL FLASHING | ||||||||||||
| Scossaline in lamiera di acciaio, spessore 8/10 mm | IT. No. Art. n. | 3 | m | 26.00 | |||||||||
| 11 | 110 MM DIAMETER STEEL PIPE DOWNSPOUTS | ||||||||||||
| Pluviali in tubi di acciaio, diametro 110 mm | IT. No. Art. n. | 4 | m | 15.00 | |||||||||
| 12 | 8/10 mm THICK STEEL GUTTERS | ||||||||||||
| Gronde in lamiera di acciaio, spessore 8/10 mm | IT. No. Art. n. | 5 | m | 17.00 | |||||||||
| 13 | 8/10 mm THICK STEEL SHEET CARTER WITH 10.0cm THICK STRUCTURAL JOINT | ||||||||||||
| Carter in lamiera di acciaio spessore 8/10 mm e Giun to Strutturale Sp. 10.ocm | IT. No. Art. n. | 6 | m | 17.00 | |||||||||
| 14 | ROOF PACKAGE Pacchetto Isolamento/Impermeabilizzazione Tetto | IT. No. Art. n. | 7 | m2 | 218.00 | ||||||||
| 15 | AERATED FLOOR SLAB W/POLYPROPILENE IGLOO FORMS | ||||||||||||
| Solaio areato con forme di polipropilene tipo igloo | IT. No. Art. n. | 1 | m2 | 77.00 | |||||||||
| 16 | AERATED FLOOR SLAB W/POLYPROPILENE IGLOO FORMS | ||||||||||||
| Solaio areato con forme di polipropilene tipo igloo | IT. No. Art. n. | 1 | m2 | 77.00 | |||||||||
| 17 | AERATED FLOOR SLAB W/POLYPROPILENE IGLOO FORMS | ||||||||||||
| Solaio areato con forme di polipropilene tipo igloo | IT. No. Art. n. | 1 | m2 | 77.00 | |||||||||
| 18 | INTERNAL PLASTER Intonaco Interno | IT. No. Art. n. | 8 | m2 | 430.00 | ||||||||
| 19 | EXTERNAL PLASTER Intonaco Esterno | IT. No. Art. n. | 9 | m2 | 205.00 | ||||||||
| 20 | INTERNAL/EXTERNAL WALL/CEILING PAINTING Pitturazione interna/Esterna Muri/soffitti | IT. No. Art. n. | 10 | m2 | 840.00 | ||||||||
| 21 | 1200X2150 mm ALUMINUM DOOR, SYMBOL "D2" | ||||||||||||
| Porta in allumunio 1200x2150 mm, Sigla "D2" | IT. No. Art. n. | 11 | Ea./No. | 1.00 | |||||||||
| 22 | 2x1200X2150 mm ALUMINUM DOOR, SYMBOL "D3" | ||||||||||||
| Porta in allumunio 2x1200x2150 mm, Sigla "D3" | IT. No. Art. n. | 12 | Ea./No. | 1.00 | |||||||||
| 23 | 1200X2150 mm FIRE RATED METAL DOOR, "D4" | ||||||||||||
| Porta in ferro REI 60 1200x2150 mm, Sigla "D4" | IT. No. Art. n. | 13 | Ea./No. | 3.00 | |||||||||
| 24 | 3500X2500 mm ROLL-UP DOOR, SYMBOL "D5" | ||||||||||||
| Portone sezionale 3500x2500 mm, Sigla "D5" | IT. No. Art. n. | 14 | Ea./No. | 2.00 | |||||||||
| 25 | 2X900X2150 mm FIRE RATED METAL DOOR, "D7" | ||||||||||||
| Porta in ferro REI 60 2X900x2150 mm, Sigla "D7" | IT. No. Art. n. | 15 | Ea./No. | 1.00 | |||||||||
| 26 | FIRE CABINET AND PORTABLE EXTINGUISHER | ||||||||||||
| Armadietto portaestintore ed estintore anticendio portatile | IT. No. Art. n. | 16 | Ea./No. | 4.00 | |||||||||
| 27 | ROOF PERSONAL SAFETY HANCORS | ||||||||||||
| Ancoraggi di Sicurezza di copertura | IT. No. Art. n. | 17 | Ea./No. | 3.00 | |||||||||
| 28 | ROOF SAFETY LADDER | ||||||||||||
| Scala di Sicurezza per accesso tetto | IT. No. Art. n. | 18 | Ea./No. | 1.00 | |||||||||
| 29 | ROOF EXAUST CHIMENY | ||||||||||||
| Torrini di Ventilazione Naturale | IT. No. Art. n. | 19 | Ea./No. | 4.00 | |||||||||
| Total Architectural Work - Totale Lavori Architettonici | |||||||||||||
| FAC. 9109 IIb Structural Work - IIb Lavori Strutturali | |||||||||||||
| 30 | C16/20 LEAN CONCRETE SUBFOUNDATION | ||||||||||||
| Calcestruzzo C16/20 per sottofondazione | IT. No. Art. n. | 1 | m3 | 9.00 | |||||||||
| 31 | C20/25 CONC.FOR FOUNDATION BOND BEAM | ||||||||||||
| Calcestruzzo C20/25 per cordolo di fondazione | IT. No. Art. n. | 2 | m3 | 36.00 | |||||||||
| 32 | C25/30 CONCRETE FOR ELEVATION WALL | ||||||||||||
| Calcestruzzo C25/30 per muri in elevazione | IT. No. Art. n. | 3 | m3 | 73.50 | |||||||||
| 33 | C25/30 CONCRETE FOR CONCRETE COLUMNS | ||||||||||||
| Calcestruzzo C25/30 per pilastri in ca | IT. No. Art. n. | 4 | m3 | 1.00 | |||||||||
| 34 | PREDALLE SLAB | ||||||||||||
| Solaio Predalle | IT. No. Art. n. | 5 | m2 | 220.00 | |||||||||
| 35 | STEEL REBARS FOR RE-INFORCED CONCRETE | ||||||||||||
| Ferro d'armatura per c.a | IT. No. Art. n. | 6 | Kg | 8,000.00 | |||||||||
| 36 | STRUCTURAL WORKS FOR PAINT BOOTH SETTING | ||||||||||||
| Lavori Strutturali per Alloggiamento Cabina Verniciatura | IT. No. Art. n. | 7 | LS/AC | 1.00 | |||||||||
| 37 | TESTING | ||||||||||||
| Collaudi | IT. No. Art. n. | 8 | LS/AC | 1.00 | |||||||||
| Total Structural Work - Totale Lavori Strutturali | |||||||||||||
| FAC. 9109 IIc Civil Work - IIc Lavori Civili | |||||||||||||
| 38 | STABILIZED GRANULAR SUB-BASE | ||||||||||||
| Inerte Stabilizzato per sottofondi | IT. No. Art. n. | 1 | m3 | 112.00 | |||||||||
| 39 | EXTERNAL INDUSTRIAL CONCRETE FLOOR | ||||||||||||
| Pavimento industriale in c.a. per esterno | IT. No. Art. n. | 2 | LS/AC | 1.00 | |||||||||
| 40 | PRE-CAST CHANNEL 30x30cm | ||||||||||||
| Canala in c.a prefabbricata 30x30cm | IT. No. Art. n. | 3 | m | 24.00 | |||||||||
| 41 | 50X50 CM CONCRETE PIT | ||||||||||||
| Pozzetto in calcestruzzo 50x50 cm | IT. No. Art. n. | 4 | Ea./No. | 4.00 | |||||||||
| 42 | SITE RESTORATION | ||||||||||||
| Ripristino area esterna | IT. No. Art. n. | 5 | LS/AC | 1.00 | |||||||||
| Total CivilWork - Totale Lavori Civili | |||||||||||||
| FAC. 9109 TOTAL PART II / Totale Parte II | |||||||||||||
| FAC.9109 PART III - MECHANICAL WORK / Parte III - Lavori Meccanici | |||||||||||||
| PART IIIa - HVAC SYSTEM / Parte IIIa - impianti HVAC | |||||||||||||
| 43 | BOX FOR GAS VALVE | ||||||||||||
| Box per valvola del gas | IT. No. Art. n. | 1 | Ea./No. | 1.00 | |||||||||
| 44 | GAS LEAK DETECTION AND PREVENTION SYSTEM | ||||||||||||
| Impianto di rilevazione e prevenzione gas | IT. No. Art. n. | 2 | LS/AC | 1.00 | |||||||||
| 45 | THREADED BALL VALVES FOR GAS SYSTEM 3" | ||||||||||||
| Valvole a sfera filettate per impianto gas 3" | IT. No. Art. n. | 3 | Ea./No. | 2.00 | |||||||||
| 46 | GALVANIZED STEEL PIPES FOR GAS | ||||||||||||
| Tubi zincati per gas | IT. No. Art. n. | 4 | kg | 135.00 | |||||||||
| 47 | CONNECTION TO EXIST. GAS MAIN LINE | ||||||||||||
| Collegamento alla rete principale esistente del gas | IT. No. Art. n. | 5 | LS/AC | 1.00 | |||||||||
| 48 | POLYETHYLENE PIPE FOR GAS DN 90 | ||||||||||||
| Tubo polietilene per gas DN 90 | IT. No. Art. n. | 6 | m | 7.00 | |||||||||
| 49 | MANHOLE cm 80 x 80 | ||||||||||||
| Pozzetto cm 80 x 80 | IT. No. Art. n. | 7 | Ea./No. | 1.00 | |||||||||
| 50 | DIELECTRIC JOINTS DIA. 3" | ||||||||||||
| Cgiunti dielettrici diam. 3" | IT. No. Art. n. | 8 | Ea./No. | 1.00 | |||||||||
| 51 | GALVANIZED SHEET METAL DUCT | ||||||||||||
| Canali in lamiera zincata | IT. No. Art. n. | 9 | kg | 940.00 | |||||||||
| 52 | THER.INSUL.DUCTS -FLEX.SHEAT.-THICK.15 mm | ||||||||||||
| Isolam.termico canali - lastra flessibile - spess. 15 mm | IT. No. Art. n. | 10 | m2 | 32.00 | |||||||||
| 53 | AIR CONDITIONER SPLIT TYPE - PAINT STOREGE | ||||||||||||
| Condizionatore split - Deposito vernici | IT. No. Art. n. | 11 | Ea./No. | 1.00 | |||||||||
| 54 | AIR CONDITIONER WITH DUCTED UNIT | ||||||||||||
| Condizionatore con mobiletto canalizzato | IT. No. Art. n. | 12 | Ea./No. | 3.00 | |||||||||
| 55 | AIR DUCTS THICKNESS 21 mm | ||||||||||||
| Canali dell'aria spessore 21 mm | IT. No. Art. n. | 13 | m2 | 35.00 | |||||||||
| 56 | SUPPLY AIR GRILLE | ||||||||||||
| Griglia di mandata | IT. No. Art. n. | 14 | Ea./No. | 9.00 | |||||||||
| 57 | RETURN AIR GRILLE | ||||||||||||
| Griglia di ripresa | IT. No. Art. n. | 15 | Ea./No. | 3.00 | |||||||||
| 58 | CONDITIONING PREINSULATED COPPER PIPE | ||||||||||||
| Tubazione in rame preisolata per condizionamento | IT. No. Art. n. | ||||||||||||
| 59 | DIAMETER 6,4 mm | ||||||||||||
| Diametro 6,4 mm | IT. No. Art. n. | 16a | m | 3.00 | |||||||||
| 60 | DIAMETER 9,5 mm | ||||||||||||
| Diametro 9,5 mm | IT. No. Art. n. | 16b | m | 30.00 | |||||||||
| 61 | DIAMETER 15,9 mm | ||||||||||||
| Diametro 15,9 mm | IT. No. Art. n. | 16c | m | 30.00 | |||||||||
| 62 | PIPING ALUMINUM JACKET COVER | ||||||||||||
| Rivestimento in alluminio delle tubazioni | IT. No. Art. n. | 17 | m2 | 6.10 | |||||||||
| 63 | HDPE PIPES AND FITTINGS | ||||||||||||
| Tubazioni in polietilene alta densità | IT. No. Art. n. | ||||||||||||
| 64 | SIZE 32 mm | ||||||||||||
| Dimensione 32 mm | IT. No. Art. n. | 18a | m | 15.00 | |||||||||
| Total HVAC Systems - Totale Impianti HVAC | |||||||||||||
| PART IIIb - PLUMBING SYSTEM / Parte IIIb - impianto idrico sanitario | |||||||||||||
| 65 | CONNECTION TO EXIST. COLD WATER LINE | ||||||||||||
| Collegamento alla rete di acqua fredda | IT. No. Art. n. | 1 | LS/AC | 1.00 | |||||||||
| 66 | GALVANIZED STEEL PIPING FOR COLD WATER | ||||||||||||
| Tubi in acciaio zincato per acqua fredda | IT. No. Art. n. | 2 | kg | 90.00 | |||||||||
| 67 | THREADED BALL VALVES DIA. 1"1/4 | ||||||||||||
| Valvola a sfera filettata diam. 1"1/4 | IT. No. Art. n. | 3 | Ea./No. | 3.00 | |||||||||
| 68 | TH.INSUL. -SHEATING+ALUM- THICK. 9 mm - DIA. 1 1/4" | ||||||||||||
| Isol. termico - guaina - spess. 9 mm - diam. 1 1/4" | IT. No. Art. n. | 4 | m | 22.00 | |||||||||
| 69 | HARD POLYETHYLENE PIPES GEBERIT TYPE DN 50 | ||||||||||||
| Tubi in polietilene rigido tipo Geberit DN 50 | IT. No. Art. n. | 5a | m | 1.00 | |||||||||
| 70 | HARD POLYETHYLENE PIPES GEBERIT TYPE DN 75 | ||||||||||||
| Tubi in polietilene rigido tipo Geberit DN 76 | IT. No. Art. n. | 5b | m | 2.00 | |||||||||
| 71 | EMERGENCY STATION SHOWER EYE-WASH | ||||||||||||
| Stazione di emergenza doccia lavaocchi | IT. No. Art. n. | 6 | Ea./No. | 2.00 | |||||||||
| Total PLUMBING SYSTEM - Totale impianto idrico-sanitario | |||||||||||||
| PART IIIc - AIR COMPRESED SYSTEM / Parte IIIc - impianto aria compressa | |||||||||||||
| 72 | MODIFICATION OF THE COMPRESED AIR | ||||||||||||
| Modifica connessioni impianto aria compressa | IT. No. Art. n. | 1 | LS/AC | 1.00 | |||||||||
| 73 | GALVANIZED STEEL PIPING FOR COMPRESSED AIR | ||||||||||||
| Tubi in acciaio zincato per aria compressa | IT. No. Art. n. | 2 | kg | 289.00 | |||||||||
| 74 | THREADED BALL VALVES DIA. 1/2" | ||||||||||||
| Valvola a sfera filettata diam. 1/2" | IT. No. Art. n. | 3a | Ea./No. | 5.00 | |||||||||
| 75 | THREADED BALL VALVES DIA. 1" | ||||||||||||
| Valvola a sfera filettata diam. 1" | IT. No. Art. n. | 3b | Ea./No. | 4.00 | |||||||||
| 76 | THREADED BALL VALVES DIA. 1"1/2 | ||||||||||||
| Valvola a sfera filettata diam. 1"1/2 | IT. No. Art. n. | 3c | Ea./No. | 1.00 | |||||||||
| 77 | SEPARATOR OF CONDENSE | ||||||||||||
| Separatore di condensa | IT. No. Art. n. | 4 | Ea./No. | 1.00 | |||||||||
| Total AIR COMPRESED SYSTEM - Totale impianto aria compressa | |||||||||||||
| PART IIId - SPRINKLER SYSTEM / Parte IIId - impianto sprinkler | |||||||||||||
| 78 | CONNECTION TO EXIST.MAIN LINES | ||||||||||||
| Collegamento alle reti principali esistenti | IT. No. Art. n. | 1 | LS/AC | 1.00 | |||||||||
| 79 | UNDERGR.POLYETHYL.PIPE SPRINKLER - DN 90 | ||||||||||||
| Tubo polietilene interrato per sprinkler - DN 90 | IT. No. Art. n. | 2 | m | 80.00 | |||||||||
| 80 | CONNECTION/ALARM UNIT DN 65 | ||||||||||||
| Gruppo di connessione/allarme DN 65 | IT. No. Art. n. | 3 | Ea./No. | 1.00 | |||||||||
| 81 | GALV.STEEL PIPE SPRINKLER | ||||||||||||
| Tubi acciaio zincato per sprinkler | IT. No. Art. n. | 4 | kg | 65.00 | |||||||||
| 82 | SYSTEM CONFIGURATION SPRINKLER | ||||||||||||
| Configurazione impianto sprinkler | IT. No. Art. n. | 5 | LS/AC | 1.00 | |||||||||
| 83 | TEST CONNECTION | ||||||||||||
| Derivazione di prova | IT. No. Art. n. | 6 | LS/AC | 1.00 | |||||||||
| 84 | SPRINKLER DESIGN AND CERTIFICATES | ||||||||||||
| Progetto e certificazioni sprinkler | IT. No. Art. n. | 7 | LS/AC | 1.00 | |||||||||
| Total SPRINKLER SYSTEM - Totale impianto sprinkler | |||||||||||||
| TOTAL PART III / Totale Parte III | |||||||||||||
| FAC.9109 PART IV- ELECTRICAL WORK / Parte IV - Lavori Elettrici | |||||||||||||
| 1 | FURNISH AND INSTALL NEW PAINT BOOTH 7mX4mx2,70m AS REQUIRED BY BLOWTHERM SPECIFIC - SEE TECHNICAL SPECIFICATION IN TO WORK ITEM | ||||||||||||
| fornitura e posa in opera di nuova cabina di verniciatura 7mx4mx2,70m come da specifiche della Blowtherm - analizzare specifiche tecnicahe inserite nel capitolato tecnico. | IT. No. Art. n. | 1 | LS/AC | 1.00 | |||||||||
| 2 | "QN1" NEW ELECTRICAL PANEL | ||||||||||||
| nuovo quadro elettrico esistente "QN1" | IT. No. Art. n. | 2a | LS/AC | 1.00 | |||||||||
| 3 | "BPR" EXISTING ELECTRICAL PANEL (QN2) | ||||||||||||
| quadro elettrico esistente "BPR" (QN2) | IT. No. Art. n. | 2b | LS/AC | 1.00 | |||||||||
| 4 | ELECTRICAL CABLE FG16OR16 2X1,5mmq | ||||||||||||
| Cavo elettrico FG16OR16 2X1,5mmq | IT. No. | 3a | m | 80.00 | |||||||||
| 5 | ELECTRICAL CABLE FG16OR16 3G1,5mmq | ||||||||||||
| Cavo elettrico FG16OR16 3G1,5mmq | IT. No. | 3b | m | 85.00 | |||||||||
| 6 | ELECTRICAL CABLE FG16OR16 3G2,5mmq | ||||||||||||
| Cavo elettrico FG16OR16 3G2,5mmq | IT. No. | 3c | m | 160.00 | |||||||||
| 7 | ELECTRICAL CABLE FG16OR16 3G4mmq | ||||||||||||
| Cavo elettrico FG16OR16 3G4mmq | IT. No. | 3d | m | 235.00 | |||||||||
| 8 | ELECTRICAL CABLE FG16OR16 3G6mmq | ||||||||||||
| Cavo elettrico FG16OR16 3G6mmq | IT. No. | 3e | m | 70.00 | |||||||||
| 9 | ELECTRICAL CABLE FG16OR16 4G4mmq | ||||||||||||
| Cavo elettrico FG16OR16 4G4mmq | IT. No. | 3f | m | 20.00 | |||||||||
| 10 | ELECTRICAL CABLE FG16OR16 5G4mmq | ||||||||||||
| Cavo elettrico FG16OR16 5G4mmq | IT. No. | 3g | m | 120.00 | |||||||||
| 11 | ELECTRICAL CABLE FG16OR16 5G6mmq | ||||||||||||
| Cavo elettrico FG16OR16 5G6mmq | IT. No. | 3h | m | 140.00 | |||||||||
| 12 | ELECTRICAL CABLE FG16OR16 5G10mmq | ||||||||||||
| Cavo elettrico FG16OR16 5G10mmq | IT. No. | 3I | m | 25.00 | |||||||||
| 12 | FURNISHING AND INSTALLATION NEW PVC CONDUIT - DIAM 20mm | ||||||||||||
| Fornitura e posa in opera di nuova tubazione in pvc rigida - diametro 20mm | IT. No. | 4a | m | 120.00 | |||||||||
| 13 | FURNISHING AND INSTALLATION NEW PVC CONDUIT - DIAM 25mm | ||||||||||||
| Fornitura e posa in opera di nuova tubazione in pvc rigida - diametro 25mm | IT. No. | 4b | m | 150.00 | |||||||||
| 14 | FURNISHING AND INSTALLATION NEW PVC CONDUIT - DIAM 32mm | ||||||||||||
| Fornitura e posa in opera di nuova tubazione in pvc rigida - diametro 32mm | IT. No. | 4c | m | 150.00 | |||||||||
| 15 | FURNISHING AND INSTALLATION NEW PVC CONDUIT - DIAM 40mm | ||||||||||||
| Fornitura e posa in opera di nuova tubazione in pvc rigida - diametro 40mm | IT. No. | 4d | m | 100.00 | |||||||||
| 16 | FURNISHING AND INSTALLATION NEW TRAY CABLE 150x75mm | ||||||||||||
| Fornitura e posa in opera di nuovo canale metallico 150x75mm | IT. No. | 5a | m | 165.00 | |||||||||
| 17 | FURNISHING AND INSTALLATION OF WALL FLUSHED POWER POINT FOR GENERAL USE. | ||||||||||||
| Fornitura e posa in opera di punto di alimentazione generale | IT. No. | 6 | EA/NO | 12.00 | |||||||||
| 18 | FURNISHING AND INSTALLATION OF ELECTRICAL RECEPTACLE EU+IT STANDARD - IP40 | ||||||||||||
| forniturae posa in opera di presa elettriche standard europeo+italiano - IP40 | IT. No. | 7a | EA/NO | 5.00 | |||||||||
| 19 | FURNISHING AND INSTALLATION OF 2P+G-230V-16A CEE TYPE INTERLOCKED OUTLET WITH FUSE, PLUG PROVIDED | ||||||||||||
| forniturae posa in opera di presa interbloccata stagna tipo CEE (2P+T+230V-16A) con fusibili e completa di spina. | IT. No. | 7b | EA/NO | 4.00 | |||||||||
| 20 | FURNISHING AND INSTALLATION OF 3P+G-400V-16A CEE TYPE INTERLOCKED OUTLET WITH FUSE, PLUG PROVIDED | ||||||||||||
| forniturae posa in opera di presa interbloccata stagna tipo CEE (3P+T+400V-16A) con fusibili e completa di spina. | IT. No. | 7c | EA/NO | 4.00 | |||||||||
| 21 | FURNISHING AND INSTALLATION OF 3P+G-400V-32A CEE TYPE INTERLOCKED OUTLET WITH FUSE, PLUG PROVIDED | ||||||||||||
| forniturae posa in opera di presa interbloccata stagna tipo CEE (3P+T+400V-32A) con fusibili e completa di spina. | IT. No. | 7d | EA/NO | 3.00 | |||||||||
| 22 | FURNISHING AND INSTALLATION OF WALL LIGHT BUTTON OR SWITCH-IP40/55 | ||||||||||||
| fornitura e posa in opera di Interruttore o pulsante a vista - IP40/55 | IT. No. | 8a | EA/NO | 2.00 | |||||||||
| 23 | FURNISHING AND INSTALLATION OF WALL FLUSHED LIGHT SHUNT-IP40/55 | ||||||||||||
| Fornitura e posa in opera di Deviatore a vista - IP40/55 | IT. No. | 8b | EA/NO | 4.00 | |||||||||
| 23 | FURNISHING AND INSTALLATION OF LIGHT POINT ADDED | ||||||||||||
| fornitura e posa in opera di punto luce aggiunto | IT. No. | 8c | EA/NO | 39.00 | |||||||||
| 24 | FURNISHING AND INSTALLATION OF LIGHTING OUTLET POSITION - EXTERNAL | ||||||||||||
| Fornitura e posa in opera di punto luce - esterno | IT. No. | 8d | EA/NO | 4.00 | |||||||||
| 24 | FURNISHING AND INSTALLATION OF STEEL LED LIGHTING FIXTURE 68W (LED 2X30W) WATERPROOF-3FFILIPPI 55149 TYPE | ||||||||||||
| fornitura e posa in opera di plafoniera a LED 68W (LED 2x30W) in acciaio -TIPO -3FFILIPPI 55149 | IT. No. | 9a | EA/NO | 17.00 | |||||||||
| 24 | FURNISHING AND INSTALLATION OF EXTERNAL FLOOD LIGHT FOR LED LAMP 113W 12420lm - DISANO TYPE | ||||||||||||
| fornitura e posa in opera di proiettore industriale da esterno, per lampade a led 113W - 12420 lumen - tipo disano | IT. No. | 9b | EA/NO | 5.00 | |||||||||
| 25 | FURNISH AND INSTALL EXIT/EMERGENCY LIGHT, 2 HOURS RATED DURATION, LED LAMP - 400 LM | ||||||||||||
| fornitura e posa in opera di lampada di emergenza, autonomia 2 ore, lampada al led, 400 lumen | IT. No. | 10a | EA/NO | 13.00 | |||||||||
| 26 | FURNISHING AND INSTALLATION OF LED EMERGENCY LIGHTING IP65 EXIT SIGN, 2 HOURS RATED DURATON. | ||||||||||||
| Lampada di emergenza con segnale "EXIT" a led, 2 ore di autonomia. | IT. No. | 10b | EA/NO | 4.00 | |||||||||
| 27 | FURNISHING AND INSTALLATION EMERGENCY BUTTON-IP65 | ||||||||||||
| Fornitura e posa in opera di pulsante di emergenza - IP65 | IT. No. | 11 | EA/NO | 2.00 | |||||||||
| 28 | GROUNDING AND LIGHTINING PROTECTION SYSTEM EXTENSION | ||||||||||||
| Estensione Impianto di messa a terra e impianto LPS | IT. No. | 12 | LS/AC | 1.00 | |||||||||
| 29 | FURNISH AND INSTALL OPTICAL FIRE SMOKE DETECTOR, ADRESSABLE TYPE. | ||||||||||||
| Fornitura e posa in opera di rivelatore di fumo indirizzabile | IT. No. | 13a | EA/NO | 5.00 | |||||||||
| 30 | FURNISH AND INSTALL HEAT DETECTOR, ADRESSABLE TYPE. | ||||||||||||
| Fornitura e posa in opera di rivelatore termovelocimetrico | IT. No. | 13b | EA/NO | 1.00 | |||||||||
| 31 | FURNISH AND INSTALL GAS DETECTOR ADRESSABLE TYPE. | ||||||||||||
| Fornitura e posa in opera di rivelatore di gas | IT. No. | 13c | EA/NO | 1.00 | |||||||||
| 32 | FURNISH AND INSTALL FIRE MANUAL PULL STATION, ADRESSABLE TYPE. | ||||||||||||
| Fornitura e posa in opera pulsante manuale di allarme incendio | IT. No. | 13d | EA/NO | 4.00 | |||||||||
| 33 | FURNISH AND INSTALL OPTIC / ACOUSTIC FIRE ALARM DEVICE. | ||||||||||||
| Fornitura e posa in opera di dispositivo di allarme incendio ottico / sonoro. | IT. No. | 13e | EA/NO | 4.00 | |||||||||
| 34 | FURNISH AND INSTALL ADRESSABLE GA ALARM CONTROL PANEL. EQUIPPED WITH 2X12V / 7AH BATTERIES AND ACCESSORIES. | ||||||||||||
| Fornitura e posa in opera di centrale allarme gas. Equipaggaita con batterie 2x12V / 7Ah ed accessori. | IT. No. | 13f | LS/AC | 1.00 | |||||||||
| 161 | FURNISH AND INSTALL ADDRESSABLE MODULE ANALOGUE INTERFACES 2 INPUTS + 1 OUTPUT MODULE | ||||||||||||
| Fornitura e posa in opera di modulo indirizzato - 2 moduli di ingresso e 1 uscita | IT. No. | 13g | EA/NO | 3.00 | |||||||||
| 161 | FURNISH AND INSTALL AUDIO-VISUAL OUTDOOR ALARM DEVICE - IP55 | ||||||||||||
| Fornitura e posa in opera di avvisatore audio-visivo da esterno per impianto allarme-IP55 | IT. No. | 13h | EA/NO | 3.00 | |||||||||
| 35 | FURNISH AND INSTALL CABLES FOR FIRE ALARM AND SIGNALING SYSTEM - FTE40M1 100/100V (PH120) UNI9795 TYPE SECTION 2X1,5 SQ.MM. | ||||||||||||
| Fornitura e posa in opera di cavo per applicazioni in sistemi fissi automatici di segnalazine e allarme incendio - FTE40M1 100/100V (PH120) UNI9795 - sezione 2x1,5 mmq. | IT. No. | 14a | m | 400.00 | |||||||||
| 36 | FURNISH AND INSTALL LOOP CABLE FOR FIRE ALARM DETECTORS, PULL STATIONS, ETC. - SECTION 2X1 SQ.MM.-FG4OHM1 100/100V TYPE UNI9795. | ||||||||||||
| Fornitura e posa in opera di cavo loop per allarme incendio - FG4OHM1 100/100V sezione 2x1 mmq. UNI9795. | IT. No. | 14b | m | 550.00 | |||||||||
| 37 | TEST AND CERTIFICATION OF THE NEW FIRE ALARM SYSTEM. | ||||||||||||
| Collaudo e certificazione del nuovo impianto allarme incendio. | IT. No. | 14c | LS/AC | 1.00 | |||||||||
| 38 | EXECUTION OF THE AS BUILT DRAWINGS AND SCHEDULES | ||||||||||||
| Redazione ed emissione di disegni e schemi di As Built finali | IT. No. | 14d | LS/AC | 1.00 | |||||||||
| 37 | FURNISHING AND INSTALLATION NEW RED STEEL PIPE - DIAM 25mm | ||||||||||||
| Fornitura e posa in opera di nuova tubazione in acciaio di colore rosso - diametro 25mm | IT. No. | 15a | m | 150.00 | |||||||||
| 38 | FURNISHING AND INSTALLATION NEW RED STEEL PIPE - DIAM 40mm | ||||||||||||
| Fornitura e posa in opera di nuova tubazione in acciaio di colore rosso - diametro 40mm | IT. No. | 15b | m | 120.00 | |||||||||
| 40 | SEALING THE HOLES | ||||||||||||
| Sigillare i fori o gli attraversamenti | IT. No. Art. n. | 16 | LS/AC | 1.00 | |||||||||
| TOTAL PART IV / Totale Parte IV | |||||||||||||
| PART I - DEMOLITIONS, EXCAVATIONS AND REMOVALS | |||||||||||||
| PART II - ARCHITECTURAL, STRUCTURAL AND CIVIL WORK | |||||||||||||
| PART III - MECHANICAL WORK | |||||||||||||
| PART IV - ELECTRICAL WORK | |||||||||||||
| TOTAL PRICE / Costo Totale |
&C&"Arial,Grassetto"&12FOR OFFICIAL USE ONLY &C&12FOR OFFICIAL USE ONLY&RSheet &P of &N
RPR 9109
| CONSTRUCTION COST ESTIMATE BREAKDOWN | |||||||||||||
| CONTRACTOR | ADDRESS | ||||||||||||
| CONTRACT FOR (Work to be performed) | PROPOSED TOTAL CONTRACT PRICE | ||||||||||||
| CONSTRUCT ADDITION REPAIR CORROSION CONTROL FAC. 9109 AND DEMO FAC.973 AND 974, AREA F, AVIANO AB, ITALY. | |||||||||||||
| PURCHASE REQUEST NUMBER | PROJECT NUMBER | WORK LOCATION | |||||||||||
| ASHE 11-1091 REV.1 | FAC.9109 AND 9110, AREA F, AVIANO AIR BASE, ITALY | ||||||||||||
| MATERIAL COSTS | LABOR COSTS | ||||||||||||
| LINE NO. | ITEM | UNIT OF MEASURE | QUANTITY | UNIT | TOTAL | MANHOURS MANDAYS | AVERAGE RATE | TOTAL | OTHER DIRECT COSTS | LINE TOTAL | |||
| (1) | (2) | (3) | (4) | (5) | (6) | (7) | (8) | (9) | (10) | ||||
| FAC.9109 PART. B - REPAIR WORK / Lavori di Ristrutturazione | |||||||||||||
| FAC. 9109 PART I - DEMOLITIONS, EXCAVATIONS AND REMOVALS / Parte I - Demolizioni, Scavi e Rimozioni | |||||||||||||
| FAC. 9110 Ia Architectural Work - Ia Lavori Architettonici | |||||||||||||
| 1 | DEMOLITION OF INTERNAL PARTITION/CERAMIC FLOOR/CERAMIC WALL/SHOWER/SINK | ||||||||||||
| Demolizione di tramezzi interni/Pavimento Ceramica/Rivestimento Ceramica/doccia/Lavelli | IT. No. Art. n. | 1 | LS/AC | 1.00 | |||||||||
| Total Architectural Work - Totale Lavori Architettonici | |||||||||||||
| FAC.9109 Ib Structural Work - Ib Lavori Strutturali | |||||||||||||
| Not Applicable Non Applicabile | IT. No. Art. n. | ||||||||||||
| Total Structural Work - Totale Lavori Strutturali | |||||||||||||
| FAC.9109 Ic Civil Work - Ic Lavori Civili | |||||||||||||
| Not Applicable Non Applicabile | IT. No. Art. n. | ||||||||||||
| Total Civil Work - Totale Lavori Civili | |||||||||||||
| FAC.9109 Id Mechanical Work- Id Lavori Meccanici | |||||||||||||
| 2 | REMOVAL OF EXISTING PIPING, INSULATION AND FITTINGS (PLUMBING SYSTEM) | ||||||||||||
| Rimozione delle tubazioni, degli isolamenti e degli accessori esistenti (Imp. idrico sanitario) | IT. No. Art. n. | 1 | LS/AC | 1.00 | |||||||||
| 3 | REMOVAL OF EXISTING SANITARY FIXTURES AND FITTINGS (PLUMBING SYSTEM) | ||||||||||||
| Rimozione degli apparecchi sanitari esistenti ed accessori (Impianto idrico sanitario) | IT. No. Art. n. | 2 | LS/AC | 1.00 | |||||||||
| Total Mechanical Work - Totale Lavori Meccanici | |||||||||||||
| FAC.9109 Ie Electrical Work - Ie Lavori Elettrici | |||||||||||||
| 4 | REMOVAL EXISTING ELECTRICAL SYSTEM AND FIRE ALLARM SYSTEM NON COMPLIANCE | ||||||||||||
| rimozione impianto elettrico esistente e impianto allarme incendio NON CONFORME. | IT. No. Art. n. | 1 | LS/AC | 1.00 | |||||||||
| Total Electrical Work - Totale Lavori Elettrici | |||||||||||||
| TOTAL PART I / Totale Parte I | |||||||||||||
| FAC.9109 PART II - ARCHITECTURAL, STRUCTURAL AND CIVIL WORK / Parte II - Lavori Architettonici, Strutturali e Civili | |||||||||||||
| FAC.9109 IIa Architectural Work - Ia Lavori Architettonici | |||||||||||||
| 5 | 13.0 CM THICK GYPSUM BOARD PARTITIONS | ||||||||||||
| Tramezzi in cartongesso, spessore 13,0 cm | IT. No. Art. n. | 1 | m2 | 10.00 | |||||||||
| 6 | 900X2150 mm ALUMINUM DOOR, SYMBOL "D1" | ||||||||||||
| Porta in alluminio 900x2150 mm, Sigla "D1" | IT. No. Art. n. | 2 | Ea./No. | 3.00 | |||||||||
| 7 | 20x20 CM CERAMIC TILE FLOOR | ||||||||||||
| Pavimento Piastrelle di ceramica 20x20 cm | IT. No. Art. n. | 3 | m2 | 40.00 | |||||||||
| 8 | 20x20 CM CERAMIC TILE WALL | ||||||||||||
| Piastrelle di ceramica 20x20 cm per muri | IT. No. Art. n. | 4 | m2 | 80.00 | |||||||||
| 9 | PAINTING OF INTERIOR WALLS | ||||||||||||
| Tinteggiatura di pareti interne | IT. No. Art. n. | 5 | m2 | 450.00 | |||||||||
| 10 | NEW CERAMIC SINK | ||||||||||||
| Nuovo Lavello in ceramica | IT. No. Art. n. | 6 | Ea./No. | 2.00 | |||||||||
| 11 | LIQUID SOAP DISPENSER | ||||||||||||
| Dispensatore di sapone liquido | IT. No. Art. n. | 7a | Ea./No. | 2.00 | |||||||||
| 12 | PAPER TOWEL DISPENSER | ||||||||||||
| Dispensatore di salviette di carta | IT. No. Art. n. | 7b | Ea./No. | 2.00 | |||||||||
| 13 | 50x85 CM MIRROR WITH STAINLESS STEEL FRAME | ||||||||||||
| Specchio 50x85 cm con cornice in acciaio inossidabile | IT. No. Art. n. | 7c | Ea./No. | 3.00 | |||||||||
| 14 | ELECTRIC HAND DRYER | ||||||||||||
| Asciugamani elettrico | IT. No. Art. n. | 7d | Ea./No. | 2.00 | |||||||||
| 15 | SOAP HOLDER | ||||||||||||
| Portasapone | IT. No. Art. n. | 7e | Ea./No. | 2.00 | |||||||||
| 16 | SHOWER FOLDING DOOR | ||||||||||||
| Porta a soffietto per doccia | IT. No. Art. n. | 7f | Ea./No. | 2.00 | |||||||||
| 17 | METAL CATWALK FOR SAND AREA | ||||||||||||
| Camminamento in metallo Zona Sabbiatura | IT. No. Art. n. | 8 | LS/AC | 1.00 | |||||||||
| 18 | NEW PLENUM GATE DESIIGN AND BUILD | ||||||||||||
| Design and Build del nuovo portone plenum | IT. No. Art. n. | 9 | LS/AC | 1.00 | |||||||||
| Total Architectural Work - Totale Lavori Architettonici | |||||||||||||
| FAC.9109 IIc Structural Work - IIc Lavori Strutturali | |||||||||||||
| Not Applicable |
Non applicabile
| Total StructuralL Work - Totale Lavori Strutturali | ||||
| FAC.9109 IIb Civil Work - IIb Lavori Civili | ||||
| 19 | Sketch # 1 works | |||
| Lavori come da schema 1 | LS/AC | 1.00 | ||
| Total Civil Work - Totale Lavori Civili | ||||
| TOTAL PART II / Totale Parte II | ||||
| FAC.9109 PART III - MECHANICAL WORK / Parte III - Lavori Meccanici | ||||
| 20 | SHOWER | |||
| Doccia | IT. No. Art. n. | 1 | Ea./No. | 2.00 |
| 21 | NEW WATER CONNECTION TO SANITARY APPLIANCES | |||
| Nuove connesioni idrauliche agli apparecchi sanitari | IT. No. Art. n. | 2 | LS/AC | 1.00 |
| 22 | NEW DRAIN CONNECTION TO SANITARY APPLIANCES | |||
| New drain connections to sanitary appliances | IT. No. Art. n. | 3 | LS/AC | 1.00 |
| 21 | HVAC OVERHAUL AND RESTORING | |||
| Revisione e riparazione impianto trattamento aria | IT. No. Art. n. | 4 | LS/AC | 1.00 |
| 22 | UPDATE HYDRANT SYSTEM BUILDING 9109 | |||
| Adeguamento rete idranti esterna per costruzione edificio 9109 | IT. No. Art. n. | 5 | LS/AC | 1.00 |
| TOTAL PART III / Totale Parte III | ||||
| FAC.9109 PART IV- ELECTRICAL WORK / Parte VI - Lavori Elettrici | ||||
| 23 | FURNISHING AND INSTALLATION OF THE NEW BACKUP AC UNITS - 250KVA-400VAC -external position | |||
| fornitra e posa in opera di nuovo gruppo elettrogeno da 250KVA-400VAC da esterno cofanato | IT. No. Art. n. | 1 | LS/AC | 1.00 |
| 24 | FURNISHING AND INSTALLATION NEW CENTRAL POWER SUPPLY SYSTEMS (CPSS) FOR FOAM SYSTEM - CPSS 3F - 200KVA - 48 MINUTES - 30KW | |||
| nuovo box soccorritore (CPSS) per pompe antincendio - CPSS TRIFASE 200 KVA - 48 MINUTI - 30 KW | IT. No. Art. n. | 2 | LS/AC | 1.00 |
| 25 | "Q0" EXISTING ELECTRICAL PANEL - REVISE | |||
| Quadro elettrico esistente "Q0" - da modificare | IT. No. Art. n. | 3a | LS/AC | 1.00 |
| 26 | "Q11" EXISTING ELECTRICAL PANEL - REVISE | |||
| Quadro elettrico esistente "Q11" - da modificare | IT. No. Art. n. | 3b | LS/AC | 1.00 |
| 27 | "Q5" EXISTING ELECTRICAL PANEL - REVISE | |||
| Quadro elettrico esistente "Q5" - da modificare | IT. No. Art. n. | 3c | LS/AC | 1.00 |
| 28 | "Q6" EXISTING ELECTRICAL PANEL - REVISE | |||
| Quadro elettrico esistente "Q6" - da modificare | IT. No. Art. n. | 3d | LS/AC | 1.00 |
| 29 | ADJUSTING AND UP-DATE THE ACH550-01 DRIVES ABB; RESTORE THE RELIABILITY OF THE POWER DISTRIBUTION SYSTEM OF THE HVAC BUILDING ( RCD, GROUNDING LOOP, SUPPRESSOR FILTERS,); | |||
| Adeguamento impiantistico dei driver ABB ACH550-01 medinate il ripristino delle protezioni esistenti in fase di collaudo del prodotto (RCD, messa terra, filtri EMC) | IT. No. Art. n. | 3e | LS/AC | 1.00 |
| 30 | FURNISHING AND INSTALLATION OF TRANSFORMER 400Vac / 208-120Vac-50/60HZ-5KVA | |||
| Fornitura e installazione trasformatore 400Vac / 208/120Vac -50-60HZ-5KVA | IT. No. Art. n. | 4 | LS/AC | 1.00 |
| 31 | ELECTRICAL CABLE FG16OR16 1x35mmq | |||
| Cavo elettrico FG16OR16 1x35mmq | IT. No. | 5a | m | 560.00 |
| 32 | ELECTRICAL CABLE FG16OR16 1x16mmq | |||
| Cavo elettrico FG16OR16 1x16mmq | IT. No. | 5b | m | 370.00 |
| 33 | ELECTRICAL CABLE FG16OR16 5G6mmq | |||
| Cavo elettrico FG16OR16 5G6mmq | IT. No. | 5c | m | 60.00 |
| 34 | ELECTRICAL CABLE FG16OR16 3G6mmq | |||
| Cavo elettrico FG16OR16 3G6mmq | IT. No. | 5d | m | 370.00 |
| 35 | ELECTRICAL CABLE FG16OR16 2X1,5mmq | |||
| Cavo elettrico FG16OR16 2x1,5 mmq | IT. No. | 5e | m | 150.00 |
| 36 | ELECTRICAL CABLE FG16OR16 3G4mmq | |||
| Cavo elettrico FG16OR16 3G4mmq | IT. No. | 5f | m | 420.00 |
| 37 | ELECTRICAL CABLE FTG10OM1 1x240mmq | |||
| Cavo elettrico FTG10OM1 1x240mmq | IT. No. | 6a | m | 135.00 |
| 38 | ELECTRICAL CABLE FTG10OM1 1x120mmq | |||
| Cavo elettrico FTG10OM1 1x120mmq | IT. No. | 6b | m | 250.00 |
| 39 | ELECTRICAL CABLE FTG10OM1 1x70mmq | |||
| Cavo elettrico FTG10OM1 1x70mmq | IT. No. | 6c | m | 115.00 |
| 40 | SUPPLY AND INSTALLATION AT SIGHT, OR DIGGING WITHIN WELLS, CONDUITS OF HIGH-DENSITY POLYETHYLENE "HDPE DIAM. 160mm | |||
| Fornitura e posa in opera a vista, entro cavedi o scavo, di cavidotti in polietilene alta densità "PEHD DIAM. 160mm | IT. No. | 7 | m | 50.00 |
| 41 | PRECAST REINFORCED CONCRETE MANHOLES WITH MANHOLE DRIVEWAY VIBRATED BY 50X50X50X5cm. | |||
| Pozzetti prefabbricati in CLS armato vibrato con chiusino carrabile da 50x50x50x5cm | IT. No. | 8a | EA/NO | 1.00 |
| 42 | FURNISHING AND INSTALLATION NEW PVC CONDUIT - DIAM 20mm | |||
| Fornitura e posa in opera di nuova tubazione in pvc rigida - diametro 20mm | IT. No. | 9a | m | 300.00 |
| 43 | FURNISHING AND INSTALLATION NEW PVC CONDUIT - DIAM 25mm | |||
| Fornitura e posa in opera di nuova tubazione in pvc rigida - diametro 25mm | IT. No. | 9b | m | 120.00 |
| 44 | FURNISHING AND INSTALLATION NEW PVC CONDUIT - DIAM 32mm | |||
| Fornitura e posa in opera di nuova tubazione in pvc rigida - diametro 32mm | IT. No. | 9c | m | 100.00 |
| 45 | FURNISHING AND INSTALLATION NEW PVC CONDUIT - DIAM 40mm | |||
| Fornitura e posa in opera di nuova tubazione in pvc rigida - diametro 40mm | IT. No. | 4d | m | 150.00 |
| 46 | FURNISHING AND INSTALLATION NEW TRAY CABLE 150x75mm | |||
| Fornitura e posa in opera di nuovo canale metallico 150x75mm | IT. No. | 10a | m | 15.00 |
| 47 | FURNISHING AND INSTALLATION NEW TRAY CABLE 200x75mm | |||
| Fornitura e posa in opera di nuovo canale metallico 200x75mm | IT. No. | 10b | m | 25.00 |
| 48 | FURNISHING AND INSTALLATION OF WALL LIGHT BUTTON OR SWITCH-IP40/55 | |||
| Fornitura e posa in opera di Interruttore o pulsante a vista - IP40/55 | IT. No. | 11a | EA/NO | 2.00 |
| 49 | FURNISHING AND INSTALLATION OF LIGHT POINT ADDED | |||
| fornitura e posa in opera di punto luce aggiunto | IT. No. | 11b | EA/NO | 71.00 |
| 50 | LIGHT POINT ADDED MOVEMENT DETECTOR RECESSED IN SUSPENDED CEILING - LUXOMAT PD3-1C TYPE | |||
| Fornitura e posa in operadi rivelatore di movimento incassato a controsoffitto - TIPO LUXOMAT PD3-1C | IT. No. | 11c | EA/NO | 2.00 |
| 43 | FURNISHING AND INSTALLATION OF NEW LIGHTING CONTROL PANEL FOR BAY. | |||
| Fornitura e posa in opera di nuovo quadro di controllo luce per hangar. | IT. No. | 11d | EA/NO | 2.00 |
| 44 | FURNISHING AND INSTALLATION OF FLOOD LIGHT 154W - Ex-d - CORTEM TYPE | |||
| fornitura e posa in opera di proiettore industriale da esterno, a fascio largo LED 154W - Ex -d - tipo CORTEM | IT. No. | 12a | EA/NO | 24.00 |
| 45 | FURNISHING AND INSTALLATION LED LIGHTING FIXTURE 2x31W - TYPE II 2GD Ex-d IIC T6 - FLFE-231L (GE) CORTEM TYPE (5414 lm; 52.0 W) | |||
| Fornitura e posa in opera di plafoniera a led 2x31w - tipo ii 2gd ex-d iic t6 - flfe-231l (ge) tipo cortem (5414 lm; 52.0 w) | IT. No. | 12b | EA/NO | 11.00 |
| 46 | 4x14W IP20 LIGHTING FIXTURE DARK LIGHT | |||
| Lampada IP20 4x14W dark light | IT. No. | 13a | EA/NO | 1.00 |
| 47 | FURNISHING AND INSTALLATION OF STEEL LED LIGHTING FIXTURE 68W (LED 2X30W) WATERPROOF-3FFILIPPI 55149 TYPE | |||
| fornitura e posa in opera di plafoniera a LED 68W (LED 2x30W) in acciaio -TIPO -3FFILIPPI 55149 | IT. No. | 13b | EA/NO | 8.00 |
| 48 | AS ABOVE BUT WITH EMERGENCY BATTERY UNIT (EMERGENCY WIRING, 2HR DURATION WITH 24HRS RECHARGE, FUSE. COMPLIANT WITH EN 60598-2-22. | |||
| Come sopra ma con batteria d'emergenza (cablaggio in emergenza 2 ore di autonomia, ricarica 24h, fusibile. conforme alla norma en 60598-2-22.) | IT. No. | 13c | EA/NO | 9.00 |
| 49 | FURNISH AND INSTALL EXIT/EMERGENCY LIGHT, 2 HOURS RATED DURATION, LED LAMP - 400 LM | |||
| fornitura e posa in opera di lampada di emergenza, al ni Cd di emergenza, 2 ore di autonomia, lampada al led, 400 lumen | IT. No. | 14a | EA/NO | 24.00 |
| 50 | FURNISHING AND INSTALLATION OF LED EMERGENCY LIGHTING IP65 EXIT SIGN, 2 HOURS RATED DURATON. | |||
| Lampada di emergenzasegnale "EXIT" a led, 2 ore di autonomia | IT. No. | 14b | EA/NO | 12.00 |
| 51 | FURNISH AND INSTALL OF GALVANIZED STEEL PIPE (UNI 7683) - 1 INCH DIAMETER | |||
| Fornitura e posa in opera di tubo in acciaio zinacato (UNI 7683) - diametro 1 pollice | IT. No. | 15a | m | 320.00 |
| 52 | FURNISH AND INSTALL OF GALVANIZED STEEL PIPE (UNI 7683) - 2 INCH DIAMETER | |||
| Fornitura e posa in opera di tubo in acciaio zinacato (UNI 7683) - diametro 2 pollicI | IT. No. | 15b | m | 280.00 |
| 53 | FURNISH AND INSTALL CONVENTIONAL MANUAL CALL POINT - PUSH BUTTON - EXPLOSION PROOF II2GD Ex d IIB T6 | |||
| Fornitura e posa in opera di pulsante antincendio completro di cartello monitore - CE ATEX II2GD Ex d IIB T6 | IT. No. | 16a | EA/NO | 16.00 |
| 54 | FURNISH AND INSTALL BLU FLASHING LIGHT - EXPLOSION PROOF II 2GD Ex d IIC T6 | |||
| Fornitura e posa in opera lampeggiatore luminoso BLU - CE ATEX II 2GD Ex d IIC T6 | IT. No. | 16b | EA/NO | 2.00 |
| 55 | FURNISH AND INSTALL NEW LINEAR SMOKE DETECTOR, COMPLETE WITH TRANSMITTER AND RECEIVE - EEx-d | |||
| Fornitura e posa in opera di barriera lineare, completo di trasmettitore e ricevitore, barriera intrinseca, e interfaccia rele' | IT. No. | 16c | EA/NO | 4.00 |
| 56 | FURNISH AND INSTALL OPTICAL FIRE SMOKE DETECTOR, ADRESSABLE TYPE. | |||
| Fornitura e posa in opera di rivelatore di fumo indirizzabile | IT. No. | 16d | EA/NO | 7.00 |
| 57 | FURNISH AND INSTALL LED WARNING - INDICATES ABOVE CEILING ALARM SYSTEM TYPE. | |||
| Fornitura e posa in opera di LED di segnalazione allarme incedio sopra controsoffitto. | IT. No. | 16e | EA/NO | 3.00 |
| 58 | FURNISH AND INSTALL GAS DETECTOR ADRESSABLE TYPE. | |||
| Fornitura e posa in opera di rivelatore di gas | IT. No. | 16f | EA/NO | 2.00 |
| 59 | FURNISH AND INSTALL FIRE MANUAL PULL STATION, ADRESSABLE TYPE. | |||
| Fornitura e posa in opera pulsante manuale di allarme incendio | IT. No. | 16g | EA/NO | 3.00 |
| 60 | FURNISH AND INSTALL OPTIC / ACOUSTIC FIRE ALARM DEVICE. | |||
| Fornitura e posa in opera di dispositivo di allarme incendio ottico / sonoro. | IT. No. | 16h | EA/NO | 1.00 |
| 61 | FURNISH AND INSTALL ADDRESSABLE MODULE ANALOGUE INTERFACES 2 INPUTS + 1 OUTPUT MODULE | |||
| Fornitura e posa in opera di modulo indirizzato - 2 moduli di ingresso e 1 uscita | IT. No. | 16i | EA/NO | 26.00 |
| 62 | FURNISH AND INSTALL ADDERESSABLE MODULE INTERFACES FOR REVISE OF FIRE PUMP PANEL | |||
| Fornitura e posa in opera di moduli di controllo per l'adeguamento del pannello delle pompe antincendio | IT. No. | 16l | LS/AC | 1.00 |
| 63 | FURNISH AND INSTALL HITH TEMPERATURE DETECTOR WITH ADDERESSABLE MODULE INTERFACES. | |||
| Fornitura e posa in opera di rivelatore ad alta temperatura, completo di modulo I/O di interfaccia | IT. No. | 16m | EA/NO | 1.00 |
| 64 | FURNISH AND INSTALL MONOXIDE ALLARM DETECTOR, WITH ADDERESSABLE MODULE INTERFACES. | |||
| Fornitura e posa in opera di rivelatore di monossido di carbonio, completo di modulo I/O di interfaccia | IT. No. | 16n | EA/NO | 1.00 |
| 65 | FURNISH AND INSTALL ADRESSABLE FIRE ALARM CONTROL PANEL. EQUIPPED WITH 2X12V / 24AH BATTERIES AND ACCESSORIES 8 LOOP | |||
| Fornitura e posa in opera di centrale allarme incendio. Equipaggaita con batterie 2x12V / 24Ah ed accessori - 8 LOOP | IT. No. | 16o | LS/AC | 1.00 |
| 66 | FURNISH AND INSTALL ADRESSABLE GA ALARM CONTROL PANEL. EQUIPPED WITH 2X12V / 7AH BATTERIES AND ACCESSORIES. | |||
| Fornitura e posa in opera di centrale allarme gas. Equipaggaita con batterie 2x12V / 7Ah ed accessori. | IT. No. | 16p | LS/AC | 1.00 |
| 67 | FURNISH AND INSTALL CABLES FOR FIRE ALARM AND SIGNALING SYSTEM - FTE40M1 100/100V (PH120) UNI9795 TYPE SECTION 2X1,5 SQ.MM. | |||
| Fornitura e posa in opera di cavo per applicazioni in sistemi fissi automatici di segnalazine e allarme incendio - FTE40M1 100/100V (PH120) UNI9795 - sezione 2x1,5 mmq. | IT. No. | 17a | m | 400.00 |
| 68 | FURNISH AND INSTALL LOOP CABLE FOR FIRE ALARM DETECTORS, PULL STATIONS, ETC. - SECTION 2X1 SQ.MM.-FG4OHM1 100/100V TYPE UNI9795. | |||
| Fornitura e posa in opera di cavo loop per allarme incendio - FG4OHM1 100/100V sezione 2x1 mmq. UNI9795. | IT. No. | 17b | m | 600.00 |
| 69 | TEST AND CERTIFICATION OF THE NEW FIRE ALARM SYSTEM. | |||
| Collaudo e certificazione del nuovo impianto allarme incendio. | IT. No. | 17c | LS/AC | 1.00 |
| 70 | EXECUTION OF THE AS BUILT DRAWINGS AND SCHEDULES | |||
| Redazione ed emissione di disegni e schemi di As Built finali | IT. No. | 17d | LS/AC | 1.00 |
| 71 | FURNISHING AND INSTALLATION NEW RED STEEL PIPE - DIAM 25mm | |||
| Fornitura e posa in opera di nuova tubazione in acciaio di colore rosso - diametro 25mm | IT. No. | 17e | m | 250.00 |
| 72 | FURNISHING AND INSTALLATION NEW RED STEEL PIPE - DIAM 40mm | |||
| Fornitura e posa in opera di nuova tubazione in acciaio di colore rosso - diametro 40mm | IT. No. | 17f | m | 150.00 |
| 73 | SEALING THE HOLES | |||
| Sigillare i fori o gli attraversamenti | IT. No. Art. n. | 18 | LS/AC | 1.00 |
| 74 | UPDATE FIRE SUPPRESSION SYSTEM AND FIRE DETECTION DEFICIENCIES | |||
| Adeguamneto impiantistico sistema di spegnimento e imp. di rivelazione incendio | IT. No. | 19 | LS/AC | 1.00 |
| 75 | FURNISHING AND INSTALLATION OF NEW SONIC BIRD CONTROL SYSTEM, GOVERNMENT GSA APPROVED, SUITABLE TO COVER UP TO 15000 SQM., WITH SOUND PRESSURE OF 110 DB AT 1 METER AND FREQUENCY 3-5 KHZ. | |||
| Fornitura e posa in opera di nuovo sistema SONIC BIRD CONTROL, approvato dal governo GSA, idononeo per una coeprtura fino a 15000mq. pressione sonora 110DB a 1 metro e frequenza 3-5 kHz | IT. No. | 20 | LS/AC | 1.00 |
| 76 | FURNISHING AND INSTALLATION EMERGENCY BUTTON-IP65 | |||
| Fornitura e posa in opera di pulsante di emergenza - IP65 | IT. No. | 21 | EA/NO | 2.00 |
| TOTAL PART IV / Totale Parte IV | ||||
| REPAIR WORK SUMMARY / Riepilogo Lavori di Ristrutturazione | ||||
| PART I - DEMOLITIONS, EXCAVATIONS AND REMOVALS | ||||
| PART II - ARCHITECTURAL, STRUCTURAL AND CIVIL WORK | ||||
| PART III - MECHANICAL WORK | ||||
| PART IV - ELECTRICAL WORK | ||||
| TOTAL PRICE / Costo Totale |
&C&"Arial,Grassetto"&12FOR OFFICIAL USE ONLY &C&12FOR OFFICIAL USE ONLY&RSheet &P of &N
DEMO
| CONSTRUCTION COST ESTIMATE BREAKDOWN | |||||||||||||
| CONTRACTOR | ADDRESS | ||||||||||||
| CONTRACT FOR (Work to be performed) | PROPOSED TOTAL CONTRACT PRICE | ||||||||||||
| CONSTRUCT ADDITION REPAIR CORROSION CONTROL FAC. 9109 AND DEMO FAC.973 AND 974, AREA F, AVIANO AB, ITALY. | |||||||||||||
| PURCHASE REQUEST NUMBER | PROJECT NUMBER | WORK LOCATION | |||||||||||
| ASHE 11-1091 REV.1 | FAC.9109 AND 9110, AREA F, AVIANO AIR BASE, ITALY | ||||||||||||
| MATERIAL COSTS | LABOR COSTS | ||||||||||||
| LINE NO. | ITEM | UNIT OF MEASURE | QUANTITY | UNIT | TOTAL | MANHOURS MANDAYS | AVERAGE RATE | TOTAL | OTHER DIRECT COSTS | LINE TOTAL | |||
| (1) | (2) | (3) | (4) | (5) | (6) | (7) | (8) | (9) | (10) | ||||
| FAC.973 AND 974 PART. D DEMO WORK | |||||||||||||
| 1 | DEMOLITION OF FAC. 973 AND 974 | ||||||||||||
| Demolizione edifci 973 e 974 | IT. No. Art. n. | 1 | LS/AC | 1.00 | |||||||||
| 0.00 | 0.00 | 0.00 | |||||||||||
| Total DEMO WORKS - Totale Lavori di demolizione | 0.00 | 0.00 | 0.00 | 0.00 |
NEW 9110
| CONSTRUCTION COST ESTIMATE BREAKDOWN | |||||||||||||
| CONTRACTOR | ADDRESS | ||||||||||||
| CONTRACT FOR (Work to be performed) | PROPOSED TOTAL CONTRACT PRICE | ||||||||||||
| CONSTRUCT ADDITION REPAIR CORROSION CONTROL FAC. 9109 AND DEMO FAC.973 AND 974, AREA F, AVIANO AB, ITALY. | |||||||||||||
| PURCHASE REQUEST NUMBER | PROJECT NUMBER | WORK LOCATION | |||||||||||
| ASHE 11-1091 REV.1 | FAC.9109 and 9110, AREA F, AVIANO AIR BASE, ITALY | ||||||||||||
| MATERIAL COSTS | LABOR COSTS | ||||||||||||
| LINE NO. | ITEM | UNIT OF MEASURE | QUANTITY | UNIT | TOTAL | MANHOURS MANDAYS | AVERAGE RATE | TOTAL | OTHER DIRECT COSTS | LINE TOTAL | |||
| (1) | (2) | (3) | (4) | (5) | (6) | (7) | (8) | (9) | (10) | ||||
| FAC. 9110 PART. A - NEW CONSTRUCTION / Nuova Costruzione | |||||||||||||
| FAC.9110 PART I - DEMOLITIONS, EXCAVATIONS AND REMOVALS / Parte I - Demolizioni, Scavi e Rimozioni | |||||||||||||
| FAC. 9110 Ia Architectural Work - Ia Lavori Architettonici | |||||||||||||
| Not Applicable Non Applicabile | IT. No. Art. n. | ||||||||||||
| Total Architectural Work - Totale Lavori Architettonici | |||||||||||||
| FAC.9110 Ib Structural Work - Ib Lavori Strutturali | |||||||||||||
| 1 | CONCRETE PAD DEMOLITION Demolizione Piazzola in c.a. | IT. No. Art. n. | 1 | LS/AC | 1.00 | ||||||||
| 2 | EXCAVATION FOR FOUNDATIONS | ||||||||||||
| Scavo per Fodazioni in c.a. | IT. No. Art. n. | 2 | m3 | 90.00 | |||||||||
| Total Structural Work - Totale Lavori Strutturali | |||||||||||||
| FAC.9110 Ic Civil Work - Ic Lavori Civili | |||||||||||||
| 3 | EXCAVATION FOR NEW SUB-BASE | ||||||||||||
| Scavo sbancamento | IT. No. Art. n. | 1 | m3 | 45.00 | |||||||||
| 4 | EXCAVATION FOR NEW CONDUIT | ||||||||||||
| Scavo per nuove tubazioni interrate | IT. No. Art. n. | 2 | m3 | 60.00 | |||||||||
| Total Civil Work - Totale Lavori Civili | |||||||||||||
| FAC.9110 Id Mechanical Work - Id Lavori Meccanici | |||||||||||||
| Not Applicable Non Applicabile | IT. No. Art. n. | ||||||||||||
| Total Mechanical Work - Totale Lavori Meccanici | |||||||||||||
| FAC. 9110 Ie Electrical Work - Ie Lavori Elettrici | |||||||||||||
| 5 | REMOVAL EXISTING ELECTRICAL SYSTEM | ||||||||||||
| rimozione impianto elettrico esistente | IT. No. Art. n. | 1 | LS/AC | 1.00 | |||||||||
| Total Electrical Work - Totale Lavori Elettrici | |||||||||||||
| TOTAL PART I - Totale Parte I | |||||||||||||
| FAC. 9110 PART IIa - ARCHITECTURAL, STRUCTURAL AND CIVIL WORK / Parte IIa - Lavori Architettonici, Strutturali e Civili | |||||||||||||
| IIa Architectural Work - Ia Lavori Architettonici | |||||||||||||
| 6 | 8/10 mm THICK STEEL FLASHING | ||||||||||||
| Scossaline in lamiera di acciaio, spessore 8/10 mm | IT. No. Art. n. | 1 | m | 154.00 | |||||||||
| 7 | 8/10 mm THICK STEEL SHEET CARTER | ||||||||||||
| Carter in lamiera di acciaio spessore 8/10 mm | IT. No. Art. n. | 2 | m | 26.00 | |||||||||
| 8 | WALLS SANDWICH PANELS Pannelli Sandwich di tamponamento | IT. No. Art. n. | 3 | m2 | 540.00 | ||||||||
| 9 | 1200X2150 mm ALUMINUM DOOR, SYMBOL "D2" | ||||||||||||
| Porta in allumunio 1200x2150 mm, Sigla "D2" | IT. No. Art. n. | 4 | Ea./No. | 2.00 | |||||||||
| 10 | 3000X1700 mm ALUMINUM WINDOW, SYMBOL "W2" | ||||||||||||
| Finestra in allumunio 3000x1700 mm, Sigla "W2" | IT. No. Art. n. | 5 | Ea./No. | 4.00 | |||||||||
| 11 | SLIDING GATE | ||||||||||||
| Portoni scorrevoli | IT. No. Art. n. | 6 | Ea./No. | 1.00 | |||||||||
| 12 | FIRE RATED PAINTING | ||||||||||||
| Pittura Intumescente REI 60 | IT. No. Art. n. | 7 | LS/AC | 1.00 | |||||||||
| 13 | ROOF EXAUST CHIMENY | ||||||||||||
| Torrini di Ventilazione Naturale | IT. No. Art. n. | 8 | Ea./No. | 6.00 | |||||||||
| 14 | ROOF PERSONAL SAFETY HANCORS | ||||||||||||
| Ancoraggi di Sicurezza di copertura | IT. No. Art. n. | 9 | Ea./No. | 4.00 | |||||||||
| Total Architectural Work - Totale Lavori Architettonici | |||||||||||||
| FAC.9110 IIb Structural Work - IIb Lavori Strutturali | |||||||||||||
| 15 | C16/20 LEAN CONCRETE SUBFOUNDATION | ||||||||||||
| Calcestruzzo C16/20 per sottofondazione | IT. No. Art. n. | 1 | m3 | 2.00 | |||||||||
| 16 | C20/25 CONC.FOR FOUNDATION BOND BEAM | ||||||||||||
| Calcestruzzo C20/25 per cordolo di fondazione | IT. No. Art. n. | 2 | m3 | 48.00 | |||||||||
| 17 | STEEL REBARS FOR RE-INFORCED CONCRETE | ||||||||||||
| Ferro d'armatura per c.a | IT. No. Art. n. | 3 | Kg | 6,000.00 | |||||||||
| 18 | STRUCTURAL STEEL PROFILES | ||||||||||||
| Profili in ferro per strutture | IT. No. Art. n. | 4 | Kg | 5,500.00 | |||||||||
| 19 | TESTING | ||||||||||||
| Collaudi | IT. No. Art. n. | 5 | LS/AC | 1.00 | |||||||||
| Total Structural Work - Totale Lavori Strutturali | |||||||||||||
| FAC. 9110 IIc Civil Work - IIc Lavori Civili | |||||||||||||
| 20 | STABILIZED GRANULAR SUB-BASE | ||||||||||||
| Inerte Stabilizzato per sottofondi | IT. No. Art. n. | 1 | m3 | 70.00 | |||||||||
| 21 | EXTERNAL INDUSTRIAL CONCRETE FLOOR | ||||||||||||
| Pavimento industriale in c.a. per esterno | IT. No. Art. n. | 2 | m3 | 56.00 | |||||||||
| 22 | PRE-CAST CHANNEL 30x30cm | ||||||||||||
| Canala in c.a prefabbricata 30x30cm | IT. No. Art. n. | 3 | m | 25.00 | |||||||||
| 23 | SITE RESTORATION | ||||||||||||
| Ripristino area esterna | IT. No. Art. n. | 4 | LS/AC | 1.00 | |||||||||
| 24 | BITUMINOUS WEARING COURSE 3CM | ||||||||||||
| Asfalto per strato d'usura sp.3cm | IT. No. Art. n. | 5 | SQ/MQ | 45.00 | |||||||||
| Total CivilWork - Totale Lavori Civili | |||||||||||||
| TOTAL PART II / Totale Parte II | |||||||||||||
| FAC.9110 PART III - MECHANICAL WORK / Parte III - Lavori Meccanici | |||||||||||||
| PART IIIa - HVAC SYSTEMS / Parte IIIa -Impianti HVAC | |||||||||||||
| 25 | PACKAGED SYSTEM WITH HEAT GENERATOR | ||||||||||||
| Gruppo preassemblato con generatore di calore | IT. No. Art. n. | 1 | LS/AC | 1.00 | |||||||||
| 26 | SMOKE STACK DIA. 130 MM | ||||||||||||
| Raccordo al camino diam. 130 mm | IT. No. Art. n. | 2 | m | 4.00 | |||||||||
| 27 | CHIMNEY DIA. 130 mm | ||||||||||||
| Camino diam. 130 mm | IT. No. Art. n. | 3 | m | 14.00 | |||||||||
| 28 | CIRCULATING PUMP CP | ||||||||||||
| Pompa circolazione CP | IT. No. Art. n. | 4 | Ea./No. | 2.00 | |||||||||
| 29 | EXPANSION TANK CAP. 50 liters | ||||||||||||
| Vaso espansione cap. 50 litri | IT. No. Art. n. | 5 | Ea./No. | 1.00 | |||||||||
| 30 | HEAT COUNTER - HEATING SYSTEM - 2" | ||||||||||||
| Contatore di calore - impianto riscaldamento - 2" | IT. No. Art. n. | 6 | Ea./No. | 1.00 | |||||||||
| 31 | THREADED BALL VALVES DIA. 2" | ||||||||||||
| Valvola a sfera filettata diam. 2" | IT. No. Art. n. | 7 | Ea./No. | 7.00 | |||||||||
| 32 | THREADED CHECK VALVE DIA. 2" | ||||||||||||
| Valvola ritegno filettata diam. 2" | IT. No. Art. n. | 8 | Ea./No. | 2.00 | |||||||||
| 33 | THERMOMETERS PIPE INSTALLED | ||||||||||||
| Termometri da tubazione | IT. No. Art. n. | 9 | Ea./No. | 2.00 | |||||||||
| 34 | MANOMETRI | ||||||||||||
| Manometri | IT. No. Art. n. | 10 | Ea./No. | 4.00 | |||||||||
| 35 | HYDRONIC SEPARATOR | ||||||||||||
| Separatore idraulico | IT. No. Art. n. | 11 | Ea./No. | 1.00 | |||||||||
| 36 | ANTI-FREEZING THERMOSTAT | ||||||||||||
| Termostato antigelo | IT. No. Art. n. | 12 | Ea./No. | 1.00 | |||||||||
| 37 | ELECTRICAL RADIATOR 1.000 W | ||||||||||||
| Radiatore elettrico 1.000 W | IT. No. Art. n. | 13 | Ea./No. | 1.00 | |||||||||
| 38 | CEILING RADIANT PANELS | ||||||||||||
| Termostrisce radianti a soffitto | IT. No. Art. n. | 14 | Ea./No. | 7.00 | |||||||||
| 39 | ROOM THERMOSTAT, BLACK BULB TYPE, ATEX | ||||||||||||
| Termostato ambiente a bulbo nero ATEX | IT. No. Art. n. | 15 | Ea./No. | 1.00 | |||||||||
| 40 | BLACK STEEL PIPING - HEATING LINES | ||||||||||||
| Tubazioni in acciaio nero per riscaldamento | IT. No. Art. n. | 16 | kg | 690.00 | |||||||||
| 41 | THERMAL INSULATION - FIBER GLASS AND ALUMINUM - THICK. 60 mm | ||||||||||||
| Isolamento termico - fibre vetro e alluminio - spess. 60 mm | IT. No. Art. n. | 17 | m2 | 8.50 | |||||||||
| 42 | TH.INSUL. -SHEATING+ALUM.-THICK. 19 mm-DIA. 3/4" | ||||||||||||
| Isolam.termico - guaina+allum. - spess. 19 mm - diam. 3/4" | IT. No. Art. n. | 18a | m | 17.00 | |||||||||
| 43 | TH.INSUL. -SHEATING+ALUM.-THICK. 19 mm-DIA. 1 1/4" | ||||||||||||
| Isolam.termico - guaina+allum. - spess. 19 mm - diam. 1 1/4" | IT. No. Art. n. | 18b | m | 13.00 | |||||||||
| 44 | TH.INSUL. -SHEATING+ALUM.-THICK. 19 mm-DIA. 1 1/2" | ||||||||||||
| Isolam.termico - guaina+allum. - spess. 19 mm - diam. 1 1/2" | IT. No. Art. n. | 18c | m | 13.00 | |||||||||
| 45 | TH.INSUL. -SHEATING+ALUM.-THICK. 19 mm-DIA. 2" | ||||||||||||
| Isolam.termico - guaina+allum. - spess. 19 mm - diam. 2" | IT. No. Art. n. | 18d | m | 75.00 | |||||||||
| 46 | THREADED BALL VALVES DIA. 3/4" | ||||||||||||
| Valvola a sfera filettata diam. 3/4" | IT. No. Art. n. | 19 | Ea./No. | 14.00 | |||||||||
| 47 | FLEXIBLE STEEL PIPES, INOX | ||||||||||||
| Tubi flessibili inox | IT. No. Art. n. | 20 | Ea./No. | 14.00 | |||||||||
| 48 | THERMAL TAPE | ||||||||||||
| termonastro | IT. No. Art. n. | 21 | m | 5.00 | |||||||||
| 49 | BOX FOR GAS VALVE | ||||||||||||
| Box per valvola del gas | IT. No. Art. n. | 22 | Ea./No. | 1.00 | |||||||||
| 50 | GAS LEAK DETECTION AND PREVENTION SYSTEM | ||||||||||||
| Impianto di rilevazione e prevenzione gas | IT. No. Art. n. | 23 | LS/AC | 1.00 | |||||||||
| 51 | THREADED BALL VALVES FOR GAS SYSTEM 2" | ||||||||||||
| Valvole a sfera filettate per impianto gas 2" | IT. No. Art. n. | 24a | Ea./No. | 2.00 | |||||||||
| 52 | THREADED BALL VALVES FOR GAS SYSTEM 3" | ||||||||||||
| Valvole a sfera filettate per impianto gas 3" | IT. No. Art. n. | 24b | Ea./No. | 1.00 | |||||||||
| 53 | GALVANIZED STEEL PIPES FOR GAS | ||||||||||||
| Tubi zincati per gas | IT. No. Art. n. | 25 | kg | 280.00 | |||||||||
| 54 | POLYETHYLENE PIPE FOR GAS DN 63 | ||||||||||||
| Tubo polietilene per gas DN 63 | IT. No. Art. n. | 26a | m | 25.00 | |||||||||
| 55 | POLYETHYLENE PIPE FOR GAS DN 110 | ||||||||||||
| Tubo polietilene per gas DN 110 | IT. No. Art. n. | 26b | m | 35.00 | |||||||||
| 56 | MANHOLE cm 80 x 80 | ||||||||||||
| Pozzetto cm 80 x 80 | IT. No. Art. n. | 27 | Ea./No. | 2.00 | |||||||||
| 57 | DIELECTRIC JOINTS DIA. 2" | ||||||||||||
| Giunti dielettrici diam. 2" | IT. No. Art. n. | 28a | Ea./No. | 1.00 | |||||||||
| 58 | DIELECTRIC JOINTS DIA. 3" | ||||||||||||
| Giunti dielettrici diam. 3" | IT. No. Art. n. | 28b | Ea./No. | 1.00 | |||||||||
| 59 | CONNECTION TO EXIST. GAS MAIN LINE | ||||||||||||
| Collegamento alla rete principale esistente del gas | IT. No. Art. n. | 29 | LS/AC | 1.00 | |||||||||
| 60 | HARD POLYETHYLENE PIPES GEBERIT TYPE DN 50 | ||||||||||||
| Tubi in polietilene rigido tipo Geberit DN 50 | IT. No. Art. n. | 30a | m | 5.00 | |||||||||
| 61 | HARD POLYETHYLENE PIPES GEBERIT TYPE DN 75 | ||||||||||||
| Tubi in polietilene rigido tipo Geberit DN 75 | IT. No. Art. n. | 30b | m | 10.00 | |||||||||
| Total HVAC Systems - Totale Impianti HVAC | |||||||||||||
| PART IIIb - PLUMBING SYSTEMS / PARTE IIIb - Impianto idrico-sanitario | |||||||||||||
| 62 | CONNECTION TO EXIST. COLD WATER LINE | ||||||||||||
| Collegamento alla rete di acqua fredda | IT. No. Art. n. | 1 | LS/AC | 1.00 | |||||||||
| 63 | BACK FLOW PREVENTER DIA. 3/4" | ||||||||||||
| Disconnettore diam. 3/4" | IT. No. Art. n. | 2 | Ea./No. | 1.00 | |||||||||
| 64 | PRESSURE REDUCING VALVE DIA. 3/4" | ||||||||||||
| Riduttore di pressione diam. 3/4" | IT. No. Art. n. | 3 | Ea./No. | 1.00 | |||||||||
| 65 | MICROMETRIC FILTER DIA. 3/4" | ||||||||||||
| Filtro micrometrico diam. 3/4" | IT. No. Art. n. | 4 | Ea./No. | 1.00 | |||||||||
| 66 | POLYAMINE DOSER | ||||||||||||
| Dosatore di poliammine | IT. No. Art. n. | 5 | Ea./No. | 1.00 | |||||||||
| 67 | WATER MAKE-UP AUTOMATIC FEEDER DIA. 1/2" | ||||||||||||
| Alimentatore automatico diam. 1/2" | IT. No. Art. n. | 6 | Ea./No. | 1.00 | |||||||||
| 68 | VOLUME COUNTER FOR COLD WATER DIA. 3/4" | ||||||||||||
| Contatore portata per acqua fredda diam. 3/4" | IT. No. Art. n. | 7 | Ea./No. | 1.00 | |||||||||
| 69 | THREADED BALL VALVES DIA. 1/2" | ||||||||||||
| Valvola a sfera filettata diam. 1/2" | IT. No. Art. n. | 8a | Ea./No. | 2.00 | |||||||||
| 70 | THREADED BALL VALVES DIA. 3/4" | ||||||||||||
| Valvola a sfera filettata diam. 3/4" | IT. No. Art. n. | 8b | Ea./No. | 8.00 | |||||||||
| 71 | THREADED BALL VALVES DIA. 1"1/4 | ||||||||||||
| Valvola a sfera filettata diam. 1"1/4 | IT. No. Art. n. | 8c | Ea./No. | 1.00 | |||||||||
| 72 | THREADED CHECK VALVE DIA. 3/4" | ||||||||||||
| Valvola ritegno filettata diam. 3/4" | IT. No. Art. n. | 9 | Ea./No. | 1.00 | |||||||||
| 73 | GALVANIZED STEEL PIPING FOR COLD WATER | ||||||||||||
| Tubi in acciaio zincato per acqua fredda | IT. No. Art. n. | 10 | kg | 270.00 | |||||||||
| 74 | TH.INSUL. -SHEATING+ALUM.-THICK. 9 mm-DIA. 3/4" |
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it.