ASHE_18-1039_SOW_ADD__2.pdf

PDF 20 KB Posted

Attached to
ASHE 18-1039 RENOVATE BLDG. 7300 FOR 56TH SQUADRON, AREA F, AVIANO AB
Solicitation number
FA5682-18-R-0026
Issued by

About this file

ADDENDUM#2 ASHE 18-1039

View the file

Other files

File Type Posted
FA568218R0026_0001.pdf PDF
FA568218R0026.pdf PDF
ASHE_18-1039_Tech_Specs_R.pdf PDF
ASHE_18-1039_Drawings_1_-_REV.pdf PDF
ASHE_18-1039_SOW_ADD__1.pdf PDF
Additional_Requirements.pdf PDF
ASHE_18-1039_CnstCostEstimate_R.xls XLS spreadsheet
ASHE_18-1039__Technical_Specifications.pdf PDF
ASHE_18-1039__Drawings_1.pdf PDF
ASHE_18-1039__Drawings_2.pdf PDF
Master_Technical_Specs_Nov_2005_English.zip ZIP file
ASHE_18-1039__Safety_Plan.pdf PDF
Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Project # ASHE 18-1039 A#2 Statement of Work DATE: May 2018

31CES/CENM 1

ASHE 18-1039

RENOVATION OF BLDG 7300 FOR 56TH SQUADRON

AREA F, AVIANO AB, AVIANO (PN) ITALY

ADDENDUM #2

A2.1 Access doors locks:

A2.1.1 In revised specifications, page 3:

A2.1.1.1. Change the item: ”Provision and installation of new keypad/badge reader electronic system on existing doors to control access in rooms no. 050, 053, 035, and 061.” To read:” Provision and installation of new keypad/badge interconnected reader electronic system “rolling code technology” on existing doors to control access in rooms no. 050, 053, 035, and 061”;

A2.1.1.2. Change the item: “Provision and installation of keyless mechanical lockset to all exterior access doors and some interior doors as indicated on the drawings” to read:

“Provision and installation of new keypad/badge interconnected reader electronic system “rolling code technology”on all exterior access doors and some interior doors as indicated on the drawings”.

A2.1.2 Page 15 in material submittal change, item 7 “Mechanical Cipher Lock Part IIb Item 14” to read “keypad/badge interconnected reader electronic system part Part IIb item 13 and 15”.

A2.1.3 Page 69, Part IIb, item 13, change: “Door upgrade for the installation of new control access electronic system on existing doors type “D1” and “D4” to control access in rooms

no. 050, 053, 035 and 061. Item includes:

- Provision and installation of new automatic door closer

- Provision and installation of new magnetic seal alarm

- All operations necessary for the workmanlike execution of the work.

To read: “Door upgrade for the installation of new control access electronic system on existing doors type “D1” and “D4” to control access in rooms no. 050, 053, 035 and

061. Item includes:

-Design, realization and certification of the feeding electric system;

-Design, realization and certification of network control system connected to a portable computer furnished with another item;

- Provision and installation of new automatic door closer

- Provision and installation of new magnetic seal alarm

- All operations necessary for the workmanlike execution of the work”

A2.1.4 Page 70, Part IIb, item 15, change: “Provision and installation of new keypad mechanical lockset system on existing interior and exterior doors type “D6” including cylinder with a “master” key in common for emergency opening. Item includes:

-All new hardware necessary works to upgrade the existing locksets in order not to inhibit opening operations by internal existing opening devices -All operations necessary for the workmanlike execution of the work.

To read: “Provision and installation of new control access electronic system on existing interior and exterior doors type “D6” including cylinder with a “master” key in common for emergency opening. Item includes:

Project # ASHE 18-1039 A#2 Statement of Work DATE: May 2018

31CES/CENM 2

-Design, realization and certification of the feeding electric system;

-Design, realization and certification of network control system connected to a portable computer;

-Furnishing and installation of a new industrial computer certified to work 7/7 24/24 with professional hardware static components only made (SSD HHD professional, static dissipation system for CPU, etc.) and consistent with suggested performance given from software manufacturer, operating system consistent with the dedicated software to create the access cards and to register continuously the doors access to have a log of all access indicating day, time, door and card and if the door is opened from inside (of course without the card number) including the training which includes filmed frontal lesson and power points;

-Furnishing and installation of the system to create the cards;

-All new hardware necessary works to upgrade the existing locksets in order not to inhibit opening operations by internal existing opening devices -All operations necessary for the workmanlike execution of the work”

A2.2 Page 74 Part III Mechanical Works, IIIa HVAC system, Item 5, the original system is “Kiebach & Peter” and the area technician to refer to is Mr. Andrea Boraso 349-8087019.

File details come from the government source that posted it.