This document appears to be a data sheet providing test results for Victor Blast Protectors. The data sheet includes penetration depth measurements and associated California Bearing Ratio (CBR) values for the blast protectors tested in sandy/gravel soil.

The related federal contract opportunity is for the Department of the Air Force United States Air Forces in Europe - Air Forces Africa to procure 200 linear meters (656 feet) of mobile jet blast barriers. The barriers must be portable, designed to withstand wind speeds up to 45 m/s (100 mph), and between 6.7 m (22 ft) to 9 m (29.5 ft) in height. They will be constructed of hot dipped galvanized steel and installed on a concrete base with forklift slots for portability.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DCP TEST DATA

File Name: DCP 6

Project: Victor Blast Protectors Date: 12-Sep-24 Location: Soil Type(s): sandy/gravel

No. of Accumulative Type of

Blows Penetration Hammer (mm)

0 110 1

2 180 1

4 230 1

5 255 1

6 280 1

8 315 1

10 340 1

13 370 1

15 395 1

17 420 1

20 445 1

23 470 1

27 495 1

31 520 1

35 545 1

40 570 1

45 595 1

50 620 1

54 645 1

59 670 1

63 695 1

67 720 1

72 750 1

76 775 1

80 800 1

84 825 1

89 860 1

93 885 1

96 910 1

1 10 100 1000 10000

1 10 100 1000 10000

D E

P T

H , i n

CBR

D E

P T

H , m m

10.1 lbs.

17.6 lbs.

Both hammers used

Soil Type

CH

CL

All other soils

Hammer