FA520510R0007_Attachment_1_Specifications.pdf
PDF 2 MB Posted
- Attached to
- Roads and Pavements IDIQ Contract Federal contract opportunity
- Solicitation number
- FA5205-10-R-0007
About this file
Attachment 1 Specifications RFP No. FA5205-10-R-0007
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| FA5205-10-R-0007-0001.pdf | ||
| Q A_FA5205-10-R-0007.pdf | ||
| Pre-proposal_Conference_Minutes_10R0007.pdf | ||
| FA520510R0007__SF1442.pdf | ||
| (Identifiable Offeror s Name)_10R0007_Exhibit A-C.xls | XLS spreadsheet | |
| No_Bid_Form.xls | XLS spreadsheet | |
| FA520510R0007_Attachment_3_Schedule_of_Contractors_Submittal.pdf | ||
| FA520510R0007_Attachment_4_Historical_Data.pdf | ||
| FA520510R0007_Attachment_2_Drawings.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ROADS/PAVEMENTS
IDIQ CONTRACT
SPECIFICATIONS
Date: 18 JUNE 2010 th Civil Engineer Squadron
Misawa Air Base, Japan
Prepared by:
Base Civil Engineer
Contracting Approval: _____________________
Solicitaion No. FA5205-10-R-0007
Contract No.
Attachment 1
ROADS/PAVEMENTS IDIQ CONTRACT
MISAWA AIR BASE, JAPAN
TABLE OF CONTENTS
DIVISION/
SECTION NUMBER TITLE PAGE NUMBERS
DIVISION 1 GENERAL REQUIREMENTS
01 11 00 Special Contract Requirements PAGE 1 - PAGE 35 01 33 00 Submittals PAGE 1 - PAGE 7 01 45 00 Cutting and Patching PAGE 1 - PAGE 3 01 57 20.00 10 Environmental Protection PAGE 1 - PAGE 11 01 77 00.00 20 Project Closeout PAGE 1 - PAGE 3
DIVISION 2 EXISTING CONDITIONS
02 32 00 Field and Laboratory Testing and Sampling PAGE 1 - PAGE 4 for Roads 02 41 00 Demolition and Removal PAGE 1 - PAGE 3
DIVISION 3 CONCRETE
03 31 01.00 10 Cast-In-Place Concrete (Minor Construction) PAGE 1 - PAGE 8
DIVISION 4 MASONRY
04 20 00 Reinforced Masonry PAGE 1 - PAGE 6
DIVISION 5 THROUGH DIVISION 8 (NOT USED)
DIVISION 9 FINISHES
09 90 00 Painting PAGE 1 - PAGE 14
DIVISION 10 THROUGH DIVISION 25 (NOT USED)
DIVISION 26 ELECTRICAL
26 00 00.00 20 Grounding PAGE 1 - PAGE 5 26 00 00.00 40 Electrical General Requirements PAGE 1 - PAGE 7 26 56 00 Exterior Lighting PAGE 1 - PAGE 4
DIVISION 27 THROUGH DIVISION 30 (NOT USED)
DIVISION 31 EARTHWORK
31 00 00 Earthwork for Roadways PAGE 1 - PAGE 6 31 11 00 Clearing and Grubbing PAGE 1 - PAGE 1
ROADS/PAVEMENTS IDIQ CONTRACT
TABLE OF CONTENTS (CON’T)
DIVISION/
SECTION NUMBER TITLE PAGE NUMBERS
DIVISION 32 EXTERIOR IMPROVEMENTS
32 01 16.17 Cold Milling of Bituminous Pavements PAGE 1 - PAGE 3 32 01 17 Cold-Mix Recycling PAGE 1 - PAGE 9 32 01 17.16 Sealing of Cracks in Bituminous Pavements PAGE 1 - PAGE 5 32 01 24 Hot In-Place Recycling of Bituminous Pavements PAGE 1 - PAGE 6 32 01 25 Recycled Asphalt Concrete Intermediate PAGE 1 - PAGE 10 And Wearing Courses for Roads 32 11 16.16 Subbase Course PAGE 1 - PAGE 5 32 11 24 Aggregate Base Course for Flexible Pavements PAGE 1 - PAGE 6 32 11 26.16 Portland Cement-Stabilized Subbase Course PAGE 1 - PAGE 7 32 11 27 Bituminous-Stabilized Base Course or Subgrade PAGE 1 - PAGE 11 32 11 34 Portland Cement-stabilized Base Cours or Subbase PAGE 1 - PAGE 13
Course 32 12 10 Bituminous Tack and Prime Coats PAGE 1 - PAGE 5 32 12 16 Hot-Mix Asphalt (HMA) for Roads PAGE 1 - PAGE 23 32 12 16.19 Paving Geotextile PAGE 1 - PAGE 6 32 13 13.06 Portland Cement Concrete Pavement for PAGE 1 - PAGE 16 Roads and Site Facilities 32 16 13 Concrete Sidewalks, Curbs and Gutters PAGE 1 - PAGE 12 32 16 15 Concrete Block Pavements PAGE 1 - PAGE 2 32 17 24.00 10 Pavement Markings PAGE 1 - PAGE 5 32 31 00.00 10 Fencing PAGE 1 - PAGE 9 32 92 19 Turf PAGE 1 - PAGE 7
DIVISION 33 UTILITIES
33 11 00 Water Distribution PAGE 1 - PAGE 10 33 40 01 Storm-Drainage System PAGE 1 - PAGE 6 33 70 01.00 10 Electrical Distribution System Aerial PAGE 1 - PAGE 15 33 70 02.00 10 Electrical Distribution System Underground PAGE 1 - PAGE 28
DIVISION 34 TRANSPORTATION
34 71 13.19 Traffic Barriers PAGE 1 - PAGE 3
DIVISION 35 THROUGH DIVISION 48 (NOT USED)
ROADS/PAVEMENTS IDIQ CONTRACT,
SECTION 01 11 00 PAGE 1
SECTION 01 11 00
SPECIAL CONTRACT REQUIREMENTS
PART 1 - GENERAL
1.1 GENERAL DESCRIPTION: This is an Indefinite Delivery/Indefinite Quantity (IDIQ) Contract, Roads/Pavements IDIQ Contract, Misawa AB, Japan. This project is to repair, maintain or construct roads, parking lots and/or other pavements, with their associated incidental works, such as, but not limited to, curb, gutter, U-ditch, drainage pipe, manhole, utility line, street light, sign post, fence, guardrail, traffic striping, earth work, sodding, planting, and related work on Misawa AB, Japan, and its remote areas including any U.S. Government facility within 150 KM of Misawa AB, except for Airfield at Misawa AB and Hachinohe POL. This is an IDIQ contract wherein work will be accomplished through issuance of the task order(s) on DD Form 1155 (DD 1155). The task order consists of work elements which are to be performed by the contractor to achieve specific construction requirements in the Scope of Work (SOW). In the task order, the contractor shall furnishing all labor, equipment, materials, and services including temporary work, overhead, and management necessary to perform all operations required to complete the construction for use, in accordance with the specifications and drawings, within the terms and conditions of the contract. The contractor must thoroughly understand the requirements of each Contract Line Item Number (CLIN) and its corresponding Exhibit Line Item Numbers (ELINs) and SubELINs described in this specification section to satisfy themselves of the required scope of work to be completed under the respective line items.
1.1.1 Contract Line Items/Exhibit Line Items:
1.1.1.1 GENERAL: Pricing schedule of this contract is structured in the Section B with its corresponding Exhibits A thru C. CLIN 0001, 1001, and 2001 specified in the pricing schedule, Section B of solicitation/contract are for basic year, option year one (1), and option year two (2), respectively. ELIN A001, B001 and C001 listed in the Exhibit A, B and C correspond to CLIN 0001, 1001 and 2001, respectively.
The ELINs are further broken into SubELINs (or simply called as “Line Item(s)” hereunder), which describe specific work to be furnished. Work to be performed under this contract will be composed by an aggregate of applicable Line Items listed in the Pricing Schedule. The principal features of the work to be included under the Line Items are noted herein. Work required by the drawings, specification and not particularly mentioned shall be included in the contract prices for the Line Items to which the work applies.
LINE ITEMS: The items listed hereinafter are the respective SubELINs and are also listed in the Pricing Schedule.
SECTION 01 11 00 PAGE 2
1.1.1.2 SURVEY AND TEST
SubELIN A001AA, B001 AA, and C001 AA, Quantity Survey and Report, 2,000 SM Area
A survey to identify/verify required items of work and quantities per the scope of work for the Task Order (DD 1155) in the unit of 2,000 Square Meter, as a Lot (LOT). This item shall consist of supplemental physical measuring based on a topographic survey data, including the locations and elevations of existing features, inverts, pipe sizes, etc. described in the Task Order. The report shall consist of a report per area, identifying quantity, unit price, and amount for individual proposal items and total price to complete the work. This item shall be exercised in quantities of 2,000 SM increments, appropriate to the scope of the Subject Task Order. This item does not contain topographic survey.
SubELIN A001AB, B001AB, and C001AB, Topographic Survey including Road Profile and Sections at 20 m intervals and Provide Survey Map, 2,000 SM Area
Provide a topographic survey to identify/verify required items of work and quantities per the scope of work for the Task Order (DD 1155) in the unit of 2,000 Square Meter, as a Lot (LOT). The survey shall consist of professional survey by registered surveyor, including the locations and elevations of existing natural features, inverts, pipe sizes, etc. of man-made features described in the Task Order. The report shall consist of a topographic survey map (Auto CAD File), road profile and sections at intervals of 20 meter centerline, and identifying quantity data for individual proposal items, respectively to complete the work.
This item shall be exercised in quantities of 2,000 SM increments, appropriate to the scope of the Subject Task Order.
SubELIN A001AC, B001AC, and C001AC, Quantity Survey and Report, Underground Utility Lines and Manholes
SubELIN A001AD, B001AD, and C001AD, Quantity Survey and Report, Pavement Cracks or Curbs or Markings
A survey to identify/verify required items of utility lines, pavement cracks, concrete curbs or stripe markings, and quantities shall be per linear meter (LM) described in the Task Order (DD 1155) by physically measuring. The report shall consist of a report per each required item, identifying quantity, unit price, and amount for individual utility or pavement proposal items, respectively, and total cost to complete the work. This item does not contain topographic survey.
SubELIN A001AE, B001AE, and C001AE. Field CBR and Lab Tests of Roads, Parking Lots and Other Surfaces
Field CBR (California Bearing Ratio) and laboratory test of roads, parking lots and other surfaces shall be per each (EA) test completed, including and not limited to saw cutting a 1 meter by 2 meter rectangle, removal of Asphalt Concrete (AC), performing a field CBR test and in-place density test, determining the thickness, sampling and testing in-place base/Sub-base course, backfilling and compacting, reconstruction of pavement structure, performing certified
SECTION 01 11 00 PAGE 3
laboratory tests for base course, Sub base course, and Sub-grade, and Submitting certified results of all tests in triplicate.
SubELIN A001AF, B001AF, and C001AF. Core Drilling and Sampling of AC or PCC Pavements of Roads, Parking Lots, and Other Surfaces
Core drilling and sampling of AC or Portland Cement Concrete (PCC) pavements of roads, parking lots and other surfaces shall be per each (EA.) test completed, including and not limited to coring completely through the AC or PCC pavement with a coring machine, sampling of the AC or PCC core, reconstruction of the pavement surface, and Submitting certified results of all sample measurements in triplicate, and one set of recovered and identified samples.
SubELIN A001AG, B001AG, and C001AG, Test Digging of AC Pavement, not exceed 1m x 1m x 1m including temporary pavement restoration
Test digging of AC Pavement, not to exceed 1m x 1m x 1m including temporary pavement restoration shall be per each (EA) of AC Pavement area tested, including but not limited to, AC saw cutting, excavation, backfill, temporary asphalt pavement restoration, and site cleanup.
1.1.1.3 ASPHALT CONCRETE SURFACES
SubELIN A001AH, B001AH, and C001AH, Remove & Reconstruct 50mm Thick AC Surface, including Fine Grade and Compaction
Remove & reconstruct 50mm thick AC surface, including fine grade and compaction shall be per compacted square meter (SM.) of AC pavement, including and not limited to fine grade preparation of aggregate base course, edge preparation, compaction, AC placement, compaction and testing. Milling, removal of existing AC pavement, fine grading, and compacting existing base course necessary for this work are included. Application of prime coat is not included in this line item.
SubELIN A001AJ, B001AJ, and C001AJ, 30 mm Thick AC Overlay of Paved Surfaces, including Edge Preparation & Restoration
SubELIN A001AK, B001AK, and C001AK, 50 mm Thick AC Overlay of Paved Surfaces, including Edge Preparation & Restoration
30mm, or 50 mm thick AC overlay, respectively, of existing paved surfaces, including edge preparation & restoration shall be per compacted square meter (SM.) of AC overlay, including but not limited to edge preparation & restoration, surface cleaning, AC overlay placement, compaction and testing. Application of crack sealing, prime coat or tack coat is not included in this line item.
SubELIN A001AL, B001AL, and C001AL, 50 mm Thick AC Surface, including Fine Grade and Compaction
50 mm thick AC surface, including fine grade and compaction shall be per compacted square meter (SM.) of AC pavement, including but not limited to fine grade preparation of aggregate base course, edge preparation, compaction, AC placement, compaction and testing. Application of prime coat or tack coat is not
SECTION 01 11 00 PAGE 4
SubELIN A001AM, B001AM, and C001AM, Place AC Intermediate Leveling Course
Place AC intermediate leveling course shall be per metric ton (MTON.) of AC intermediate course, including but not limited to fine grade preparation, edge preparation & restoration, placement of variable thickness AC intermediate leveling course, compaction and testing. Application of prime coat or tack coat is not included in this line item.
SubELIN A001AN, B001AN, and C001AN, Construct Base Course (Mixtured Stone M30-0)
SubELIN A001AP, B001AP, and C001AP, Construct Sub-base Course (Crushed Stone C40-0)
SubELIN A001AQ, B001AQ, and C001AQ, Construct Granular Material (Mountain Sand)
Construct base course, sub-base course or granular material, respectively, shall be per cubic meter (CM.) of compacted material in-place and ready for use, including but not limited to preparatory work, spreading and compaction to required density in 150mm lifts, fine grading, final compaction, testing and clean-
up. Application of prime coat or tack coat is not included in this line item.
SubELIN A001AR, B001AR, and C001AR, Apply Soil-Cement Stabilization of Existing or New Sub-base (200mm Thick)
Apply soil-cement stabilization of existing or new Sub-base (200mm Thick) shall be per square meter (SM.) of compacted material in-place and ready for use, including but not limited to preparatory work, spreading, water application, mixing, compaction to required density, fine grading, final compaction, testing and clean-up.
SubELIN A001AS, B001AS, and C001AS, Remix and Repave with Heating Stabilization of Existing AC Pavement, Cement and Asphalt Mixtures In-place (100mm Thick)
Remix and repave with heating stabilization of existing AC pavement, cement and asphalt mixtures in-place (100mm Thick) shall be per square meter (SM.) of compacted material in-place and ready for use, including but not limited to preparatory work, scraping/stabilizing, mixture application, heating/mixing, spreading, grading, compaction to required density, testing and clean-up.
1.1.1.4 ADDITIONAL MINOR PAVEMENT WORK
SubELIN A001AT, B001AT, and C001AT, Furnish & Apply Asphalt Prime Coat SubELIN A001AU, B001AU, and C001AU, Furnish & Apply Asphalt Tack Coat Furnish & apply asphalt prime coat, or tack coat, respectively, shall be per square meter (SM.) of new coating applied on approved base course or AC
SECTION 01 11 00 PAGE 5
surfaces, including but not limited to surface preparation, cleaning, application of new coating, protection from traffic until cured or covered by pavement, and clean-up.
SubELIN A001AV, B001AV, and C001AV, Repair Cracks of existing AC or PCC Pavement with Routing and Crack-cutting and Hot Apply Sealing, 1 - 20 mm in width and depth
Repair cracks of existing AC or PCC pavement with crack-cutting and hot apply sealing, 1-20 mm in width and depth shall be per linear meter (LM.), including but not limited to crack-cut, clean & dry at crack, primer coat, heating at thermo-melter, machine injection of crack sealant, spreading of stone dust for surface protection and curing. , Saw cutting is not included in this line item.
SubELIN A001AW, B001AW, and C001AW, Sealing Cracks or Joints in between new and existing AC or PCC Pavement with saw cutting and routing, approx. 20 mm in width and depth
Sealing cracks or joints in between new and existing AC or PCC pavement with saw cutting and routing, approx. 20 mm in width and depth shall be per linear meter (LM.), including but not limited to saw-cut, remove existing concrete chips & sealant, clean & dry surface, primer coat, application of joint sealant or bituminous mixture, protection from traffic until cured, and clean-up.
SubELIN A001AX, B001AX, and C001AX, Place Expansion Joint Filler and Sealant
Place expansion joint filler and sealant shall be per liner meter (LM.), including but not limited to saw cutting, installation of full depth pre-molded 13mm thick joint filler not including sealant depth, bond breaker if required, application of joint sealant, protection from traffic until cured, and clean-up.
SubELIN A001AY, B001AY, and C001AY, Surface Treatment on existing AC Pavement (Cold-Application Mixture, not less than 1.26 kg per square meter)
Surface treatment on existing AC pavement (Cold-application mixture, not less than 1.26 kg per square meter) shall be per square meter (SM.) of applied, including but not limited to clean, dry out surface with burner, cold mixing of reactant type emulsion & sand, surface slushing with rubber rake, continue raking, brush finish, protection from traffic until cured, and clean-up.
Crack sealing is not included in this line item.
SubELIN A001AZ, B001AZ, and C001AZ, Place Portland Cement Concrete
Placing Portland Cement Concrete (PCC) shall be per cubic meter (CM.) of miscellaneous 211 Kg/sq.cm. (3000psi) concrete complete in-place, including but not limited to surface preparation, incidental formwork, concrete placing, vibrating, finishing, curing and protection, restoration work and testing. This item is to place miscellaneous concrete for the items not already includes the PCC placement, such as saddles, thrust blocks, etc. This item does not contain topographic survey.
SECTION 01 11 00 PAGE 6
SubELIN A001BA, B001BA, and C001BA, Install Concrete Formwork
Install concrete formwork shall be per square meter (SM.) of formwork measured by the finished dimensions of the formed structure and oiled and ready for use, including but not limited to preparatory work, pre-fabrication, installation, ties, shims, stakes, braces, etc., and removal. This item is limited to only those items which do not already include formwork in the line item, such as exterior concrete columns, and etc.
SubELIN A001BB, B001BB, and C001BB, Install Concrete Reinforcement Bars
Install concrete reinforcement bars shall be per kilogram (KG.) of re-bar, including splices, complete and tied in place and ready for concrete placement, including but not limited to preparatory work, bending, cutting, pre-fabrication, chairs, seats, installation, splicing, tie wire, snap ties and all other miscellaneous materials and work. This item is limited to only those items which do not already include re-bar in the line item, such as exterior concrete columns, and etc.
1.1.1.5 RECYCLED AC PAVEMENT
SubELIN A001BC, B001BC, and C001BC, 50 mm Thick Recycled AC Overlay of Paved Surfaces, including Edge Preparation & Restoration
50 mm thick recycled AC overlay of paved surfaces, including edge preparation & restoration shall be per compacted square meter (SM.) of recycled AC overlay, including but not limited to cleaning and preparing existing surface, edge preparation & restoration, produce and deliver recycled mixtures, spreading, compaction and testing. Application of prime coat or tack coat is not included in this line item.
SubELIN A001BD, B001BD, and C001BD, 50 mm Thick Recycled AC Pavement over Base Course, including Fine Grade and Compaction
50mm thick recycled AC pavement over base course, including fine grade and compaction shall be per compacted square meter (SM.) of recycled AC pavement, including but not limited to fine grade preparation, grading, compaction, produce and deliver recycled mixtures, spreading, compaction and testing. Application of prime coat or tack coat is not included in this line item.
1.1.1.6 PAVEMENT MARKINGS
SubELIN A001BE, B001BE, and C001BE, Removal of Pavement Marking
Removal of pavement marking shall be per square meter (SM.) of removed paint without damage to existing AC or PCC surfaces, including but not limited to preparatory work, application of water-blasting and/ or light sand-blasting, and
SECTION 01 11 00 PAGE 7
SubELIN A001BF, B001BF, and C001BF, Pavement Marking Stripes, Reflective, 150mm Wide, White
Pavement marking stripes reflective, 150mm wide, white shall be per linear meter (LM.) of painted pavement markings, measured and approved, including but not limited to preparatory work, application of glass beads for reflective markings, protection until dry, and clean-up.
SubELIN A001BG, B001BG, and C001BG, Alphanumeric Concrete Curb Marking
Alphanumeric concrete curb marking shall be per each (EA.) of location of painted curb background and alphanumeric set of markings, including but not limited to preparatory work, protection until dry/ cured, and clean-up.
SubELIN A001BH, B001BH, and C001BH, White, Handicap Symbol Parking Stall Pavement Marking
White, handicap symbol parking stall pavement marking shall be per each (EA.)
of painted pavement markings, including but not limited to preparatory work, protection until dry/ cured, and clean-up.
1.1.1.7 SIDEWALK/STAIRS/SIGN POSTS/BARRICADES
SubELIN A001BJ, B001BJ, and C001BJ, Construct New Concrete Sidewalk, Complete in Place
Construct new concrete sidewalk, complete in place shall be per square meter (SM.) of placed concrete sidewalk and ready for use, including but not limited to excavation, placing base and sub-base course, compaction of base, sub-base course, and sub-grade, formwork, placing concrete, finishing surface, curing, application of transverse contraction joint testing and site clean-up. Application of saw cutting and joint sealing is not included in this line item.
SubELIN A001BK, B001BK, and C001BK, Remove and Replace existing Concrete Sidewalk, Complete in Place
Remove and replace existing concrete sidewalk, complete in place shall be per square meter (SM.) of replaced concrete sidewalk and ready for use, including but not limited to preparatory work, removal/disposal work, compaction of base course, formwork, placing concrete, finishing surface, curing, application of transverse contraction joint testing and site clean-up. Application of saw cutting and joint sealing is not included in this line item.
SubELIN A001BL, B001BL, and C001BL, Construct New Accessible Sidewalk Ramp, Type A, B, or C, Complete in Place
Construct new accessible sidewalk ramp, Type A, B, or C, complete in place shall be per each (EA.) of placed concrete sidewalk ramp and ready for use, including but not limited to excavation, placing sub-base and base course, SECTION 01 11 00 PAGE 8 compaction of base, sub-base course, and sub-grade, formwork, placing concrete, finishing surface, detectable warning system, concrete grooving, curing, application of transverse contraction joint testing and site clean-up.
Application of saw cutting and joint sealing is not included in this line item.
SubELIN A001BM, B001BM, and C001BM, Place Inter-Locking Concrete Tiles (300x300x60 mm)
Place inter-locking concrete tiles (300x300x60 mm) shall be per square meter (SM.) of inter-locking concrete tiles placed in-place and ready for use, including but not limited to excavation, placing base and sub-base course, preparatory work, compaction of base, sub-base course and sub-grade, placing inter-locking concrete tiles, finishing surface, testing and site clean-up.
SubELIN A001BN, B001BN, and C001BN, Construct New Concrete Stairs, Complete in Place
Construct new concrete stairs shall be per square meter (SM.) of concrete stairs installed in-place and ready for use, including but not limited to preparatory work, excavation/disposal work, compaction of base course/sub-grade, leveling mortar, formwork, re-bars, placing concrete mixture, finishing surface, joints, curing, application of transverse contraction joint testing and site clean-up. Application of saw cutting and joint sealing is not included in this line item.
SubELIN A001BP, B001BP, and C001BP, Install New Stair Handrails
Install new stair handrails shall be per linear meter (LM.) of stainless handrails installed in-place and ready for use, including but not limited to preparatory work, pre-fabrication of stainless handrails, installing, curing and site clean-up.
SubELIN A001BQ, B001BQ, and C001BQ, Install Traffic Sign & Post
Install traffic sign & post shall be per each (EA.) of traffic sign & post installed in-place, including but not limited to removal and disposal of excavated materials, leveling mortar, formwork, concrete footing, installation of post/sign, curing, and
SubELIN A001BR, B001BR, and C001BR, Install Traffic Sign
Install traffic sign shall be per each (EA.) of traffic sign only installed on existing post or new traffic post in-place, including but not limited to fitting accessories, installation of sign plate and clean-up.
SubELIN A001BS, B001BS, and C001BS, Install Guard Rail with Reflector (Brown Color Painted, 700mm high, R-GR.C-2B or R-GR.B-2B)
Install guard rail with reflector (brown color painted, 700mm high) shall be per linear meter (LM.) of guard rail installed in-place at shoulder, including but not limited to excavation, transportation, compaction, installation and site cleaning.
SubELIN A001BT, B001BT, and C001BT, Install Removable Steel Bollard with concrete footing, Steel Tube w/ Cover & Lock (165 mm diameter, 90 cm high)
Install removal steel bollard with concrete footing, steel tube w/cover & lock (165 mm diameter, 90 cm high) shall be per each (EA.) of steel bollard installed in-
SECTION 01 11 00 PAGE 9
place and ready for use, including but not limited to excavate, saw cutting, removal/disposal work, formwork, re-bar, concrete footing with drain hole, assembling steel tube with cover, painting, reflective tape, restoration of AC pavement, curing and clean-up.
SubELIN A001BU, B001BU, and C001BU, Install Guard Pipe 0.8m high Steel Post with Beam Pipes and continuous concrete footing
Install guard pipe 0.8m high steel post with beam pipes and continuous concrete footing shall be per linear meter (LM.) of guard pipe installed in-place, including but not limited to excavation, transportation, compaction, placing continuous concrete footing, installation guard pipes, restoration and site cleaning.
1.1.1.8 CURB, CURB AND GUTTER
SubELIN A001BV, B001BV, and C001BV, Remove and Replace existing Concrete Curbs, Cast-in-Place, 150mm Standard Barrier Type
SubELIN A001BW, B001BW, and C001BW, Remove and Replace existing Concrete Curbs and Gutters, Cast-in-Place, 150mm Standard Barrier Type
Remove and replace existing concrete curbs (and gutters), cast-in-place, 150mm standard barrier type shall be per linear meter (LM.) of replaced concrete curbs/gutters and ready for use, including but not limited to preparatory work, excavation, removal/disposal work, sub-base course, base course, compaction, formwork, installation, finishing surface, curing, testing and site clean-up.
Application of saw cutting and joint sealing is not included in this line item.
SubELIN A001BX, B001BX, and C001BX, Construct Cast-in-Place Concrete Curbs and Gutters, 150mm Standard Barrier Type
SubELIN A001BY, B001BY, and C001BY, Construct Cast-in-Place Concrete Curbs and Gutters, 150mm Standard Mountable Type
Construct cast-in-place concrete curbs (and gutters), 150mm standard barrier or mountable type shall be per linear meter (LM.) of installed concrete curbs and gutters ready for use, including but not limited to excavation, sub-grade preparation, placing of base and sub-base course, compaction, formwork, installation, finishing surface, curing, testing and site clean-up. Application of saw cutting and joint sealing is not included in this line item.
SubELIN A001BZ, B001BZ, and C001BZ, Construct Cast-in-Place Concrete High Curbs, 460mm Barrier Type
Install cast-in-place concrete high curbs, 460mm barrier type shall be per linear meter (LM.) of installed concrete high curbs and ready for use, including but not limited to excavation, sub-grade preparation, placing of base and sub-base course, compaction, formwork, rebar, installation, finishing surface, curing, testing and site clean-up. Application of saw cutting and joint sealing is not
1.1.1.9 SURFACE INLETS/STORM DRAIN LINES
SECTION 01 11 00 PAGE 10
SubELIN A001CA, B001CA, and C001CA, Raise/Lower Existing Gutter Inlet, Concrete Frame and Grating Cover
Raise/lower existing gutter inlet concrete frame and grating cover shall be per each (EA.) of gutter inlet complete and ready for use, including but not limited to removing portion of existing concrete, resetting the frame to new elevation, provision of new concrete, formwork, installation of anchor with epoxy resin, finishing and curing.
SubELIN A001CB, B001CB, and C001CB, Remove and Replace Gutter Inlet with Pre-cast Concrete Structures & Grating Cover (Load Class T-14)
SubELIN A001CC, B001CC, and C001CC, Remove and Replace Gutter Inlet with Pre-cast Concrete Structures & Grating Cover (Load Class T-25)
Remove and replace gutter inlet with pre-cast concrete structures & grating cover (Load Class T-14 or T-25) shall be per each (EA.) of replaced gutter inlet and ready for use, including but not limited to preparatory work, excavation, removal/disposal work, base course, mortar concrete, installation, connecting pipes, concrete filling, provision of grating cover, finishing and curing.
SubELIN A001CD, B001CD, and C001CD, Install New Gutter Inlet with Pre-cast Concrete Structures & Grating Cover (Load Class T-25)
Install new gutter inlet with pre-cast concrete structures & grating cover (Load Class T-25) shall be per each (EA.) of gutter inlet installed and ready for use, including but not limited to excavation, preparatory work, base course, mortar concrete, installation, connecting pipes, concrete filling, provision of grating cover, finishing and curing.
SubELIN A001CE, B001CE, and C001CE, Install New Concrete "U" Ditches with Steel Grating Cover (W300 mm x D300 mm, Load Class T-25)
SubELIN A001CF, B001CF, and C001CF, Install New Concrete "U" Ditches with Steel Grating Cover (W450 mm x D450 mm, Load Class T-25)
SubELIN A001CG, B001CG, and C001CG, Install New Heavy Duty Concrete "U" Ditches with Steel Grating Cover (W450 mm x D900 mm, Load Class T-25)
SubELIN A001CH, B001CH, and C001CH, Install Free Gradient Concrete "U" Ditches with Steel Grating Cover (W400 mm x D1,100 mm, Load Class T-25)
Install new concrete "U" ditches, heavy duty concrete “U” ditches, or free gradient concrete “U” ditches with steel grating cover (W300 mm x D300 mm, W450 mm x D450 mm, W450 mm x D900 mm, or W400 mm x D1,100 mm, load class T-25) shall be per linear meter (LM.) of “U” ditch installed and ready for use, including but not limited to excavation, preparatory work, compaction of base course, mortar concrete, associated joints, installation of pre-cast “U” ditch, fitting grating cover, backfilling, restoration, finishing and curing.
SubELIN A001CJ, B001CJ, and C001CJ, Install V-Type Concrete Ditch (W700 mm x 85 mm Thick)
Install V-type concrete ditch (W700 mm x 85 mm thick) shall be per linear meter (LM.) of ditch installed, complete and ready for use, including but not limited to excavation, preparatory work, placing of base and sub-base course, compaction, formwork, placing concrete V-type ditch in-place, reinforcement bars, backfilling, SECTION 01 11 00 PAGE 11 finishing and curing. Application of saw cutting and joint sealing is not included in this line item.
SubELIN A001CK, B001CK, and C001CK, Install 200 mm Diameter Concrete Drain Pipe
SubELIN A001CL, B001CL, and C001CL, Install 300 mm Diameter Concrete Drain Pipe
SubELIN A001CM, B001CM, and C001CM, Install 400 mm Diameter Concrete Drain Pipe
SubELIN A001CN, B001CN, and C001CN, Install 600 mm Diameter Concrete Drain Pipe
Install 200/300/400/600 mm diameter concrete drain pipe shall be per linear meter (LM.) of drain pipe installed, complete and ready for use, including but not limited to preparatory work, excavation, placing & compaction of base course, installation of pre-cast pipes, connecting joints, plastic marking tape, backfilling, finishing surface, curing and site clean-up.
SubELIN A001CP, B001CP, and C001CP, Install 50 mm Diameter Sub Drain Pipe
SubELIN A001CQ, B001CQ, and C001CQ, Install 100 mm Diameter Sub Drain Pipe
SubELIN A001CR, B001CR, and C001CR, Install 200 mm Diameter Sub Drain Pipe
Install 50/100/200 mm diameter sub drain pipe shall be per linear meter (LM.) of sub drain pipe installed, complete and ready for use, including but not limited to excavation, preparatory work, placing of stone, connecting joints, backfilling, finishing surface, curing and site clean-up.
1.1.1.10 MANHOLES/HANDHOLE/CATCH BASIN
SubELIN A001CS, B001CS, and C001CS, Raise/Lower existing Manhole Frame and Cover
SubELIN A001CT, B001CT, and C001CT, Raise/Lower existing Handhole Frame and Cover
SubELIN A001CU, B001CU, and C001CU, Raise/Lower existing Gate Valve Box
Raise/lower existing manhole, handhole, or gate valve box frame and cover shall be per each (EA.) of frame and cover complete and ready for use, including but not limited to removing portion of existing concrete, resetting the frame and cover to new elevation, formwork, provision of new concrete, installation of anchor with epoxy resin, fitting frame and cover, curing and clean-up.
SECTION 01 11 00 PAGE 12
SubELIN A001CV, B001CV, and C001CV, Replace existing Manhole with Precast Concrete Structures and Ductile Cover, 600 mm round or square (Load Class T-25)
SubELIN A001CW, B001CW, and C001CW, Replace existing Manhole with Precast Concrete Structures and Ductile Cover, 900 mm round or square (Load Class T-25)
SubELIN A001CX, B001CX, and C001CX, Replace existing Catch Basin with Precast Concrete Structures and Grating Cover, 900 mm round or square (Load Class T-25)
Replace existing manhole or catch basin with precast concrete structures and ductile cover (load class T-25) shall be per each (EA.) of manhole structures, frame and cover replaced, complete and ready for use, including but not limited to excavation, remove and disposal of existing manhole structures, installation of pre-cast concrete blocks, frame and cover, backfilling, finishing and curing.
SubELIN A001CY, B001CY, and C001CY, Install Precast Concrete Manhole, 600 mm round or square, 1.2m depth (Ductile Cover φ600mm round or square, Load Class T-6)
SubELIN A001CZ, B001CZ, and C001CZ, Install Precast Concrete Manhole, 600 mm round, or square 1.2m depth (Ductile Cover φ600mm round or square, Load Class T-25)
SubELIN A001DA, B001DA, and C001DA, Install Precast Concrete Manhole, 900mm round or square, 1.5m depth (Ductile Cover φ600mm round or square, Load Class T-6)
SubELIN A001DB, B001DB, and C001DB, Install Precast Concrete Manhole, 900mm round or square, 1.5m depth (Ductile Cover φ600mm round or square Load Class T-25)
SubELIN A001DC, B001DC, and C001DC, Install Precast Concrete Manhole, 1.2m round or square, 2.0m depth (Ductile Cover φ600mm round or square Load Class T-25)
Install precast concrete manhole with frame and cover, 600 mm square or round (load class T-6/T-25) shall be per each (EA.) of manhole installed, complete and ready for use, including but not limited to excavation, preparatory work, placing base course, compaction, mortar concrete, placing precast concrete structures, installation of ductile cover, backfilling, finishing and curing.
SECTION 01 11 00 PAGE 13
SubELIN A001DD, B001DD, and C001DD, Install Precast Handhole, φ=0.9m, D=1.5m w/accessory, Support Arms and Pin Insulator (Cover φ600 mm, Load Class T-6)
SubELIN A001DE, B001DE, and C001DE, Install Precast Handhole, H1.5m xW1.5m xD2m, w/accessory, Support Arms and Pin Insulator (Cover φ600 mm, Load Class T-6)
SubELIN A001DF, B001DF, and C001DF, Install Precast Handhole, H2m xW2m xD2m, w/accessory, Support Arms and Pin Insulator (Cover φ600 mm, Load Class T-6)
Install precast concrete handhole with frame and cover, 600 mm square or round (load class T-6) shall be per each (EA.) of handhole installed, complete and ready for use, including but not limited to excavation, preparatory work, placing base course, compaction, mortar concrete, placing precast concrete structures, installation of ductile cover, backfilling, finishing and curing.
SubELIN A001DG, B001DG, and C001DG, Install New Manhole Locking Device (Set of 4 Each per Manhole)
Install new manhole locking devices on each manhole frame and cover shall be per 4 each as a set (SET), complete and ready for use, including but not limited to locking device material and installation of locking device to the manhole cover.
1.1.1.11 WATER SUPPLY PIPE AND GATE VALVE
SubELIN A001DH, B001DH, and C001DH, Install new 50 mm Poly Vinyl Chloride Pipe and Fittings
SubELIN A001DJ, B001DJ, and C001DJ, Install new 100 mm Poly Vinyl Chloride Pipe and Fittings
SubELIN A001DK, B001DK, and C001DK, Install new 100 mm Diameter Ductile Iron Pipe and Fittings
SubELIN A001DL, B001DL, and C001DL, Install new 150 mm Diameter Ductile Iron Pipe and Fittings
SubELIN A001DM, B001DM, and C001DM, Install new 200 mm Diameter Ductile Iron Pipe and Fittings
Install new 50/100/150/200 mm diameter poly vinyl chloride pipe or ductile iron pipe and fittings shall be per linear meter (LM.) of water lines installed in-place under ground, including but not limited to excavation, compaction, installation of ductile pipe, installation of warning tape, connections, fitting and testing.
SubELIN A001DN, B001DN, and C001DN, Install Water Gate Valve 100 mm Diameter
SubELIN A001DP, B001DP, and C001DP, Install Water Gate Valve 150 mm Diameter
SubELIN A001DQ, B001DQ, and C001DQ, Install Water Gate Valve 200 mm Diameter
Install water gate valve 100/150/200 mm diameter shall be per each (EA.) of water gate valve installed, complete and ready for use, including but not limited to excavation, cutting, installation of gate valve, backfilling, testing, restoration and site cleaning.
SECTION 01 11 00 PAGE 14
SubELIN A001DR, B001DR, and C001DR, Install Air Release Valve
Install air release valve shall be per each (EA.) of air release valve installed, complete and ready for use, including but not limited to excavation, cutting, installation of air release valve, backfilling, testing, restoration and site cleaning.
SubELIN A001DS, B001DS, and C001DS, Construct Concrete Thrust Blocking
Construct concrete thrust blocking shall be per cubic meter (CM.) of concrete thrust blocking installed, complete and ready for use, including but not limited to excavation, compaction, installation of concrete thrust blocking, backfilling and site cleaning.
1.1.1.12 EARTH WORK/SODDING/PLANTING
SubELIN A001DT, B001DT, and C001DT, Construct Embankment Construct embankment shall be per cubic meter (CM.) of compacted soil embankment in-place, including but not limited to preparation and compaction of adjacent surfaces, stockpiling, testing and clean-up.
SubELIN A001DU, B001DU, and C001DU, Removal and Restoration of Sod
Removal and restoration of sod shall be per square meter (SM.) of sod restored in-place, including but not limited to removal and stockpiling of existing sod, tillage, re-sodding, fertilizing, watering and maintenance.
SubELIN A001DV, B001DV, and C001DV, Place Sod (Noshiba) Place sod shall be per square meter (SM.) of sod placed, including but not limited to soil preparation, placing sod and all work for turf establishment period.
Base standard of grass sod is Nature Sod “Noshiba” as directed by the Base Civil Engineer. Seed is Hulled, USDA fancy grade. Noshiba; seed shall be approved by Base Civil Engineer.
SubELIN A001DW, B001DW and C001DW, Apply Hydroseeding Apply Hydroseeding shall be per square meter (SM.) of hydroseeding applied, including but not limited to preparation of soil to receive the seed, application and all work for turf establishment period.
SubELIN A001DX, B001DX and C001DX, Place Topsoil, 100mm thick Place topsoil shall be per cubic meter (CM.) of new topsoil in place, including but not limited to preparation of adjacent surfaces, delivery, stockpiling, grading, scarifying, spreading, and all preparatory work to receive sod or hydroseed.
SubELIN A001DY, B001DY and C001DY, Plant Cherry Tree (Sakura), 3”/75mm
Caliper (Diameter) at Breast Height (DBH) with Guy or Pole Support.
SubELIN A001DZ, B001DZ and C001DZ, Plant Pinus Densiflore (Akamatsu), 3”/75mm Caliper (Diameter) at Breast Height (DBH) with Guy or Pole Support.
Plant Cherry Tree (Sakura) or Pinus Densiflora (Akamatsu), 3”/75mm caliper
(Diameter) at breast height (DBH) with guy or pole supports shall be per each (EA.) of tree in place, including but not limited to excavation, nursery grown
SECTION 01 11 00 PAGE 15
stock, balled, burlaped, delivery, flexible or expandable trunk protection to 30”/750mm above grade, installation of pole support, fertilizing, watering and maintenance.
SubELIN A001EA, B001EA, and C001EA, Apply Emulsion Coat to Tree Branches and Stumps Cut
Apply emulsion coat to tree branches and stumps cut shall be per square meter (SM.) of the section of branches or stumps cut, including but not limited to surface cleaning, emulsion coat, fabric installation, and clean-up.
SubELIN A001EB, B001EB, and C001EB, Place Polyester Fabric Multi Sheet for Erosion Control and Protection, 0.5 mm thk
Place polyester fabric multi sheet for erosion control and protection shall be per square meter (SM.) of polyester fabric multi sheet installed, including but not limited to preparation work, fabric sheet installation 200 g/m², and clean-up.
1.1.1.13 FENCING AND GATES
SubELIN A001EC, B001EC, and C001EC, Install Fence 2.4 m high, Chain-link w/Single Arm Extension w/barbed wire with Concrete Foundation
SubELIN A001ED, B001ED, and C001ED, Install Fence 2.4 m high, Chain-link w/Double Arm Extension w/barbed wire with Concrete Foundation
Install fence 2.4 m high, chain-link w/single/double arm extension w/barbed wire shall be per linear meter (LM.) of fence installation, complete and ready for use, including but not limited to excavation, installation of concrete foundation, transportation, compaction, installation of brace and site cleaning.
SubELIN A001EE, B001EE, and C001EE, Install Pedestrian Gate H2.4 m x W2.1 m Chain-link w/Vertical Arm Extension w/barbed wire with Concrete Foundation
SubELIN A001EF, B001EF, and C001EF, Install Double Swing Gate H2.4 m x W7.3 m Chain-link w/Single Arm Extension w/barbed wire with Concrete Foundation
Install pedestrian gate H2.4m x W2.1m or double swing gate H2.4m x W7.3m chain-link w/vertical arm extension w/barbed wire with concrete foundation shall be per each (EA.) of gate installation, complete and ready for use, including but not limited to excavation, installation of concrete foundation, transportation, compaction, installation of brace and site cleaning.
SubELIN A001EG, B001EG, and C001EG, Install 1.8 m High Decorative CMU Reinforced Wall Fence with Resin Emulsion Paint
SubELIN A001EH, B001EH, and C001EH, Install 2.2 m High Decorative CMU Reinforced Wall Fence with Resin Emulsion Paint
Install 1.8m or 2.2m high decorative CMU reinforced Wall Fence with Resin Emulsion Paint shall be per liner meter (LM.) of deco block wall fence installation, complete and ready for use, including but not limited to excavation, aggregate base, leveling mortar concrete, placing of reinforcement, installation
SECTION 01 11 00 PAGE 16
of concrete foundation and deco block wall fence, painting of resin emulsion finish, compaction, restoration and site cleaning.
SubELIN A001EJ, B001EJ, and C001EJ, Install Pedestrian Gate H2.2 m x W2.1m for Decorative CMU Reinforced Wall Fence
SubELIN A001EK, B001EK, and C001EK, Install Double Swing Gate H2.2m x W7.1 m for Decorative CMU Reinforced Wall Fence
Install pedestrian gate H2.2m x W2.1m or double swing gate H2.2m x W7.1m for decorative CMU reinforced wall fence shall be per each (EA.) of gate installation, complete and ready for use, including but not limited to excavation, installation of pedestrian gate for deco block wall fence, installation of foundation, compaction, restoration and site cleaning.
SubELIN A001EL, B001EL, and C001EL, Install Fence 2.4 m high, Lattice-frame w/Vertical Steel Pipe Extension and Concrete Foundation Install fence 2.4 m high, lattice-frame w/vertical steel pipe extension and concrete foundation shall be per linear meter (LM.) of fence installation, complete and ready for use, including but not limited to excavation, aggregate base course, compaction, installation of concrete foundation, transportation, installation of posts & frames, restoration and site cleaning.
SubELIN A001EM, B001EM, and C001EM, Install Personnel Gate H2.4m x
W2.0m, Lattice-frame w/Vertical Steel Pipe Extension and Concrete Foundation SubELIN A001EN, B001EN, and C001EN, Install Single Swing Gate H2.4m x
W5.0m, Lattice-frame w/Vertical Steel Pipe Extension and Concrete Foundation Install personnel gate H2.4m x W2.0m or single swing gate H2.4m x W5.0m, lattice-frame w/vertical steel pipe extension and concrete foundation shall be per each (EA.) of gate installation, complete and ready for use, including but not limited to excavation, aggregate base course, compaction, installation of concrete foundation, transportation, installation of posts & frames, restoration
SubELIN A001EP, B001EP, and C001EP, Install Outrigger Post @ 3.55m on
CMU Wall with 3 Stranded Barbed Wires
Install outrigger post @ 3.55m on CMU wall with 3 stranded barbed wires shall be per liner meter (LM) of outrigger installed in-place and ready for use, including but not limited to transportation, installation of posts, barbed wires, fitting and site cleaning.
SubELIN A001EQ, B001EQ, and C001EQ, Install Guard Wire and Fixed Steel
Bollard Install guard wire and fixed steel bollard shall be per linear meter (LM) of guard wires and steel bollards installation, complete and ready for use, including but not limited to transportation, installation of guard wires, steel bollards, fitting and site cleaning.
SubELIN A001ER, B001ER, and C001ER, Relocate existing Chain-link Fence with disassembling of post, frames, fabric net, barbed wires and concrete footing
SECTION 01 11 00 PAGE 17
Relocate existing chain-link fence with disassembling of post, frames, fabric net, barbed wires and concrete footing shall be per lineal meter (LM) of existing fence, including but not limited to excavation, dis-assemble fence, posts, frames, fabric net, and concrete footing, transportation, disposal of material, backfilling, fine grading, compaction, and site cleaning.
SubELIN A001ES, B001ES, and C001ES, Remove and Salvage of existing Chain-link Fence, Post, Wires, and Dispose concrete footing
Remove and salvage of existing chain-link fence, post, frames, wires, and dispose concrete footing shall be per lineal meter (LM) of existing fence, including but not limited to excavation, removal of fence, posts, and concrete footing, transportation, disposal of material, backfilling, fine grading, compaction, SubELIN A001ET, B001ET, and C001ET, Remove and Salvage existing Personnel Chain-link Gate, Post, Frames, Wires, and Dispose concrete footing
SubELIN A001EU, B001EU, and C001EU, Remove and Dispose existing Double Swing Chain-link Gate, Post, Frames, Wires, and Dispose concrete footing
Remove and salvage of existing personnel or double swing chain-link gate, post, frames, wires, and concrete footing shall be per each (EA) of existing personnel or double swing chain-link gate, including but not limited to excavation, removal of fence, posts, and concrete footing, transportation, disposal of material, backfilling, fine grading, compaction, and site cleaning.
1.1.1.14 REMOVAL AND DISPOSAL WORK
SubELIN A001EV, B001EV, and C001EV, Saw Cutting Existing AC Pavement, 50 mm in Depth
SubELIN A001EW, B001EW, and C001EW, Saw Cutting Existing Concrete Pavement, 100 mm in Depth
Saw cutting existing AC/concrete pavement shall be per linear meter (LM.) of AC/concrete saw cutting, including and not limited to traffic control and site
SubELIN A001EX, B001EX, and C001EX, 30 mm Thick Cold Planing of Existing
AC Pavement SubELIN A001EY, B001EY, and C001EY, 50 mm Thick Cold Planing of Existing
AC Pavement 30 mm or 50 mm thick cold planing of existing AC pavement shall be per square meter (SM.) of AC removed and disposed, including and not limited to removal and disposal of AC, traffic control and site cleaning.
SubELIN A001EZ, B001EZ, and C001EZ, Removal and Disposal of Asphalt
Concrete Pavement Removal and disposal of asphalt concrete pavement shall be per metric ton
(MTON.) of removed and disposed materials, including and not limited to demolition, removal and disposal off site, traffic control and site cleaning.
SECTION 01 11 00 PAGE 18
SubELIN A001FA, B001FA, and C001FA, Removal and Disposal of Sub-base/Base Course
Removal and disposal of Sub-base/base course shall be paid per cubic meter (CM.) of removed and disposed materials, including and not limited to demolition, removal and disposal off site, traffic control and site cleaning.
SubELIN A001FB, B001FB, and C001FB, Unclassified Excavation and Disposal
Unclassified excavation and disposal shall be per cubic meter (CM.) of excavated materials, including and not limited to excavation of earth to predetermined elevations, leveling, grading, compaction, removal and disposal work.
SubELIN A001FC, B001FC, and C001FC, Removal and Disposal of Reinforced Concrete
Removal and disposal of reinforced concrete shall be per metric ton (MTON) of concrete removed and disposed, including and not limited to demolition, saw cutting, removal and disposal of reinforced concrete, and site cleaning.
SubELIN A001FD, B001FD, and C001FD, Removal and Disposal of Plain Concrete
Removal and disposal of plain concrete shall be per metric ton (MTON) of concrete removed and disposed, including and not limited to demolition, removal and disposal of plain concrete, and site cleaning.
SubELIN A001FE, B001FE, and C001FE, Removal and Disposal of Concrete Curbs
Removal and disposal of concrete curbs shall be per liner meter (LM) of concrete removed and disposed, including and not limited to demolition, saw cutting, removal and disposal of plain or reinforced concrete, and site cleaning.
SubELIN A001FF, B001FF, and C001FF, Removal and Disposal of Concrete
Curbs and Gutters Removal and disposal of concrete curbs and gutters shall be per liner meter
(LM.) of concrete removed and disposed, including and not limited to demolition, saw cutting, removal and disposal of plain or reinforced concrete, and site
SubELIN A001FG, B001FG, and C001FG, Removal and Disposal of Street Light and Foundation Removal and disposal of street light and foundation shall be per each (EA) of street light removed and disposed, including and not limited to demolition of concrete foundation, saw cutting, removal and disposal of street light and foundation, and site cleaning
SubELIN A001FH, B001FH, and C001FH, Removal and Disposal of Cable with
Conduit Removal and disposal of cable with conduit shall be per linear meter (LM) of cable with conduit removed and disposed, including and not…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .