Matsushima Site Plans Annotations (21AUG26).pdf
PDF 261 KB Posted
- Attached to
- Matsushima JASDF Base Storage Shelter
- Solicitation number
- FA502526RB006
About this file
This is a site plan or aerial schematic diagram showing infrastructure and utility improvements for a proposed facility development project. The plan depicts an approximately 20-meter by 20-meter retention pond (shown in light blue) positioned in the southern portion of the site, with an oil-water fuel separator adjacent to it. Storm drainage infrastructure includes a concrete culvert and V-ditch storm drain system. The site plan identifies four membrane structures (shown in brown/tan) as the primary development area, served by secondary electrical systems with four handholes and a main electrical manhole with transformer. Water infrastructure consists of an existing water line on the western side of the site and a new 150-meter water line (shown in blue) running through the property. Electrical systems include existing primary electrical service and new primary electrical connections with five new electrical handholes (shown in red). Site perimeter security is indicated by a fenceline with a double swing gate entry point. The scale is 1:37,247 at 10 meters, with directional north indicated, allowing for spatial reference of all proposed and existing utilities relative to the facility footprint.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| RFIs-FA502526RB006 (27 Aug Updates).xlsx | XLSX spreadsheet | |
| Amendment FA502526RB0060002 SF 30.pdf | ||
| SOW CONSTRUCT RCBP STORAGE REV8.pdf | ||
| Matsushima Site Plans (21AUG26).pdf | ||
| Transfer Surface Drawing (Japanese).pdf | ||
| RFIs-FA502526RB006.xlsx | XLSX spreadsheet | |
| Solicitation Amendment FA502526RB0060001 SF 30.pdf | ||
| SOW-CONSTRUCT RCBP STORAGE REV5.pdf | ||
| Attch - Drawings.pdf | ||
| Drawings- Site Plans Updated 12 Aug 26.pdf | ||
| Solicitation - FA502526RB006.pdf |
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
20100 Meters
1:37.247
N
AutoCAD SHX Text P
AutoCAD SHX Text
RETENTION POND (20MX20M)
AutoCAD SHX Text
CONCRETE CULVERT (STORM DRAIN)
AutoCAD SHX Text
150M NEW WATER LINE
AutoCAD SHX Text
EXISTING WATER LINE
AutoCAD SHX Text
V-DITCH STORM DRAIN
AutoCAD SHX Text
OIL WATER FUEL SEPERATOR
AutoCAD SHX Text
SECONDARY ELECTRICAL W/4X HANDHOLES
AutoCAD SHX Text
NEW PRIMARY ELECTRICAL
AutoCAD SHX Text
5X NEW ELECTRICAL HANDHOLE
AutoCAD SHX Text
ELECTRICAL MANHOLE AND TRANSFORMER
AutoCAD SHX Text
EXISTING SINK
AutoCAD SHX Text
4X MEMBRANE STRUCTURES
AutoCAD SHX Text
EXISTING PRIMARY ELECTRICAL
AutoCAD SHX Text
PERIMETER FENCELINE
AutoCAD SHX Text
FENCE DOUBLE SWING GATE
| Sheets and Views |
| Layout2 |
File details come from the government source that posted it. Updated .