Text version

780 Simms Street

Suite 104

Golden, CO, 80401

303.232.3746

Certificate of Analysis www.aerobiology.net

Client Name Eielson AFB. Date Collected: 04/06/16

Street address 2310 Central Ave. Suite 101 Date Received: 04/08/16

City, State ZIP Eielson AFB. AK 99702 Date Analyzed: 04/11/16

Attn: James Walsh 200860-0 Date Reported: 04/11/16

Client Project Name: Bldg 3303 Roof Project ID: 16010293

Job ID:

Test Requested: 3002, Asbestos in Bulk Samples

Method: Polarized Light Microscopy / Dispersion Staining (PLM), Method for the Determination of Asbestos in Bulk Building Materials. EPA-600/R-93/116, July 1993.

Non-Asbestos Non-Fibrous Matrix

Fiber Material Material

Client Percentage Percentage Composition

P = Perlite B = Binder D=Diatoms

NTR = Non-Asbestiform TR NAC = Non-Asbestiform AC

780 Simms Street, Suite 104, Golden, CO, 80401, 303.232.3746

16-022

16-024

N

N

50%

100%

100%

N

Trace=Less Than 1%

N

N

100%

100%

ND=None Detected

CHRY=Chrysotile M = Mica CR = Crocidolite T = Tar TR = Tremolite

A = Amosite Q = Quartz AC = Actinolite C = Carbonates

AN = Anthophyllite G = Gypsum

ND 5 95 T

20 80 T

T

CHRY

100 T

ND 100

ND

CHRY 20 80

T

CHRY 20 80 T

CHRY

100 T

40 60

ND 90 10 T

Asbestos Percentage

Black Tar NDN 10%

90%

Asbestos Detected

Black Tar Paper

Laboratory Analyst Ron Weyand

Asbestos Laboratory Supervisor Paul Knappe

Black Tar

Black Fibrous Tar16010293-6

16010293-7

16-025 Black Tar16010293-4

Black Fibrous Tar16010293-5

16-028

16-027

16-026

NVLAP Lab Code

16010293-3A

16010293-3B

100%

N 50%

16010293-2

N

Lab Sample Number

N

Black Fibrous Tar

White Resinous Material w/Black Tar

Gray Tar

Sample Identification Physical Description of Sample/Layer

Homo-geneous

(Y/N)

Layer

Percentage

16010293-1A

16010293-1B

16-023

Page 1 of 2FA5004-16-B-C003

EIELSON AFB, AK

ATTACHMENT JA-7

ASBESTOS REPORT

http://www.aerobiology.net/

780 Simms Street

Suite 104

Golden, CO, 80401

303.232.3746

Certificate of Analysis www.aerobiology.net

Eielson AFB. Date Collected: 04/06/16

2310 Central Ave. Suite 101 Date Received: 04/08/16

Eielson AFB. AK 99702 Date Analyzed: 04/11/16

James Walsh 200860-0 Date Reported: 04/11/16

Client Project Name: Bldg 3303 Roof Project ID: 16010293

Job ID:

General Notes

ND indicates no asbestos was detected; the method detection limit is 1 %.

Trace or "<1" indicates asbestos was identified in the sample, but the concentration is less than 1%.

Notes Required by NVLAP

This test report relates only to the items tested or calibrated.

This report is not valid unless it bears the name of a NVLAP-approved signatory.

Any reproduction of this document must include the entire document in order for the report to be valid.

780 Simms Street, Suite 104, Golden, CO, 80401, 303.232.3746

NVLAP Lab Code

This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government.

All regulated asbestos minerals (i.e. chrysotile, amosite, crocidolite, anthophyllite, tremolite, and actinolite) were sought in every layer of each sample, but only those asbestos minerals detected are listed. Amosite is the common name for the asbestiform variety of the minerals cummingtonite and grunerite. Crocidolite is the common name used for the asbestiform variety of the mineral riebeckite.

Tile, vinyl, foam, plastic, and fine powder samples may contain asbestos fibers of such small diameter (< 0.25 microns in diameter) that these fibers cannot be detected by PLM.

For such samples, more sensitive analytical methods (e.g. TEM, SEM, and XRD) are recommended if greater certainty about asbestos content is required. Semi-quantitative bulk TEM floor tile analysis is accepted under NESHAP regulations.

These results are submitted pursuant to Aerobiology Laboratory Associates, Inc.’s current terms and conditions of sale, including the company’s standard warranty and limitation of liability provisions. No responsibility or liability is assumed for the manner in which the results are used or interpreted.

Unless notified in writing to return the samples covered by this report, Aerobiology Laboratory Associates, Inc. will store the samples for a minimum period of thirty (30) days before discarding. A shipping and handling charge will be assessed for the return of any samples.

Aerobiology does not guarantee the results of tape lifts, microvacs, wipe, and/or debris samples. Accurate analysis cannot be performed due to particle size, media used, and/or amount of material given. Analysis of these materials should be preformed by a TEM. A result of ND does not indicate that the sample area does not contain asbestos. It means the analyst could not identify asbestos in the specific sample for the reasons listed above.

FA5004-16-B-C003

EIELSON AFB, AK

ATTACHMENT JA-7

ASBESTOS REPORT

http://www.aerobiology.net/