Text version
780 Simms Street
Suite 104
Golden, CO, 80401
303.232.3746
Certificate of Analysis www.aerobiology.net
Client Name Eielson AFB. Date Collected: 04/06/16
Street address 2310 Central Ave. Suite 101 Date Received: 04/08/16
City, State ZIP Eielson AFB. AK 99702 Date Analyzed: 04/11/16
Attn: James Walsh 200860-0 Date Reported: 04/11/16
Client Project Name: Bldg 3303 Roof Project ID: 16010293
Job ID:
Test Requested: 3002, Asbestos in Bulk Samples
Method: Polarized Light Microscopy / Dispersion Staining (PLM), Method for the Determination of Asbestos in Bulk Building Materials. EPA-600/R-93/116, July 1993.
Non-Asbestos Non-Fibrous Matrix
Fiber Material Material
Client Percentage Percentage Composition
P = Perlite B = Binder D=Diatoms
NTR = Non-Asbestiform TR NAC = Non-Asbestiform AC
780 Simms Street, Suite 104, Golden, CO, 80401, 303.232.3746
16-022
16-024
N
N
50%
100%
100%
N
Trace=Less Than 1%
N
N
100%
100%
ND=None Detected
CHRY=Chrysotile M = Mica CR = Crocidolite T = Tar TR = Tremolite
A = Amosite Q = Quartz AC = Actinolite C = Carbonates
AN = Anthophyllite G = Gypsum
ND 5 95 T
20 80 T
T
CHRY
100 T
ND 100
ND
CHRY 20 80
T
CHRY 20 80 T
CHRY
100 T
40 60
ND 90 10 T
Asbestos Percentage
Black Tar NDN 10%
90%
Asbestos Detected
Black Tar Paper
Laboratory Analyst Ron Weyand
Asbestos Laboratory Supervisor Paul Knappe
Black Tar
Black Fibrous Tar16010293-6
16010293-7
16-025 Black Tar16010293-4
Black Fibrous Tar16010293-5
16-028
16-027
16-026
NVLAP Lab Code
16010293-3A
16010293-3B
100%
N 50%
16010293-2
N
Lab Sample Number
N
Black Fibrous Tar
White Resinous Material w/Black Tar
Gray Tar
Sample Identification Physical Description of Sample/Layer
Homo-geneous
(Y/N)
Layer
Percentage
16010293-1A
16010293-1B
16-023
Page 1 of 2FA5004-16-B-C003
EIELSON AFB, AK
ATTACHMENT JA-7
ASBESTOS REPORT
http://www.aerobiology.net/
780 Simms Street
Suite 104
Golden, CO, 80401
303.232.3746
Certificate of Analysis www.aerobiology.net
Eielson AFB. Date Collected: 04/06/16
2310 Central Ave. Suite 101 Date Received: 04/08/16
Eielson AFB. AK 99702 Date Analyzed: 04/11/16
James Walsh 200860-0 Date Reported: 04/11/16
Client Project Name: Bldg 3303 Roof Project ID: 16010293
Job ID:
General Notes
ND indicates no asbestos was detected; the method detection limit is 1 %.
Trace or "<1" indicates asbestos was identified in the sample, but the concentration is less than 1%.
Notes Required by NVLAP
This test report relates only to the items tested or calibrated.
This report is not valid unless it bears the name of a NVLAP-approved signatory.
Any reproduction of this document must include the entire document in order for the report to be valid.
780 Simms Street, Suite 104, Golden, CO, 80401, 303.232.3746
NVLAP Lab Code
This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government.
All regulated asbestos minerals (i.e. chrysotile, amosite, crocidolite, anthophyllite, tremolite, and actinolite) were sought in every layer of each sample, but only those asbestos minerals detected are listed. Amosite is the common name for the asbestiform variety of the minerals cummingtonite and grunerite. Crocidolite is the common name used for the asbestiform variety of the mineral riebeckite.
Tile, vinyl, foam, plastic, and fine powder samples may contain asbestos fibers of such small diameter (< 0.25 microns in diameter) that these fibers cannot be detected by PLM.
For such samples, more sensitive analytical methods (e.g. TEM, SEM, and XRD) are recommended if greater certainty about asbestos content is required. Semi-quantitative bulk TEM floor tile analysis is accepted under NESHAP regulations.
These results are submitted pursuant to Aerobiology Laboratory Associates, Inc.’s current terms and conditions of sale, including the company’s standard warranty and limitation of liability provisions. No responsibility or liability is assumed for the manner in which the results are used or interpreted.
Unless notified in writing to return the samples covered by this report, Aerobiology Laboratory Associates, Inc. will store the samples for a minimum period of thirty (30) days before discarding. A shipping and handling charge will be assessed for the return of any samples.
Aerobiology does not guarantee the results of tape lifts, microvacs, wipe, and/or debris samples. Accurate analysis cannot be performed due to particle size, media used, and/or amount of material given. Analysis of these materials should be preformed by a TEM. A result of ND does not indicate that the sample area does not contain asbestos. It means the analyst could not identify asbestos in the specific sample for the reasons listed above.
FA5004-16-B-C003
EIELSON AFB, AK
ATTACHMENT JA-7
ASBESTOS REPORT
http://www.aerobiology.net/