Questions and Responses 006.doc

DOC document 29 KB Posted

Attached to
RECOVERY--Z--COAL CRUSHER REPLACEMENT AT CLEAR AIR STATION, ALASKA
Solicitation number
FA5004-09-R-C009
Issued by

View the file

Other files

File Type Posted
Questions and Responses 009.doc DOC document
Attachment JA-1 Specifications —
JA-2 Wage Determination 5 June 2009.pdf PDF
P0005 Amendment 5.pdf PDF
Questions and Responses 008.doc DOC document
Questions and Responses 005.doc DOC document
Combined Specifications —
0004.pdf PDF
Questions and Responses 004.doc DOC document
Attachment JA-1 Specifications —
JA-2 Wage Determination 29 April 09.doc DOC document
Questions and Responses 003.doc DOC document
Amendment 2.pdf PDF
JA-8.6.pdf PDF
JA-8.5.pdf PDF
JA-8.2.pdf PDF
JA-8.1.pdf PDF
JA-8.8.pdf PDF
JA-8.3.pdf PDF
JA-8.7.pdf PDF
JA-8.4.pdf PDF
JA-8.9.pdf PDF
Site Visit Attendance Sheet —
Amendment 1.pdf PDF
Attachment JA-7 Drawings.pdf PDF
Notice of Question Submittal Due Date.pdf PDF
Attachment JA-2 Schedule of Wage Rates.pdf PDF
Attachment JA-1 Specifications.pdf PDF
Solicitation.pdf PDF
Attachment JA-3 Past Performance Questionaire.pdf PDF
Attachment JA-4 Financial Institution Reference Sheet.pdf PDF
Attachment JA-5 Haz Mat Sheet.pdf PDF
Attachment JA-6 AF Form 66.pdf PDF
Show all 33

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

QUESTIONS AND RESPONSES

FOR

COAL CRUSHER REPLACEMENT

AT

CLEAR AIR STATION, ALASKA

SOLICITATION NO. FA5004-09-R-C009

It shall be noted to all interested parties that the following questions have been received in writing regarding the subject acquisition. Additionally, responses have been provided to the below listed questions.

As a reminder, it is the responsibility of all Interested Parties to review this website (http://www.fedbizopps.gov) frequently for any updates and/or amendments to any and all subject documents.

Question 1:

When the upper section (coal enclosure) of the coal handling system is dismantled and removed, regardless of crusher isolation, no coal will be delivered through this section of the coal handling system. The single feed conveyor feeds the coal enclosure and transitions below this point with the option of delivering coal as a isolation between crushers.

Please clarify that there is only a 24-48 hour allowance to completely remove and replace the entire upper section(coal enclosure)and drive assembly to make operational.

Answer 1:

24-48 hours is the available time for replacing the subject section of the chute and enclosure around the conveyor drive. The enclosure around the conveyor drive is split and we see no requirement to disassemble the drive for either removal of the existing or installation of the new.