Attachment_2_-_Drawings_-_16_Nov_17_Part6.pdf

PDF 3 MB Posted

Attached to
Repair Sewer Lines Federal contract opportunity
Solicitation number
FA4897-19-B-A007
Issued by
Department of the Air Force Air Combat Command

About this file

Attach 2 - part 6 of 8

View the file

Other files for this federal contract opportunity

Other files attached to Repair Sewer Lines, newest first.
File Type Posted
Abstract_of_Offers.pdf PDF
FA489719BA0070003_Amendment_3.pdf PDF
Contractor_Questions_with_Answers-Repair_Sewer_Lines.pdf PDF
Sign_In_Sheet.pdf PDF
Attachment_1_-_Revised_Specifications_16_July_2019.pdf PDF
FA489719BA0070003_Amended_Solicitation.pdf PDF
FA4897-19-B-A007-0002_Amended_Solicitation.pdf PDF
Attachment_1_-_Revised_Specifications_18_June_2019.pdf PDF
Attachment_7_-_Amended_Submittal_Register.pdf PDF
FA4897-19-B-A007-0002_Amendment_2.pdf PDF
Attachment_2_-_Drawings_-_16_Nov_17_Part8.pdf PDF
FA4897-19-B-A007-0001_Amended_Solicitation.pdf PDF
Attachment_2_-_Drawings_-_16_Nov_17_Part1.pdf PDF
Attachment_2_-_Drawings_-_16_Nov_17_Part5.pdf PDF
FA4897-19-B-A007-0001_Amendment_1.pdf PDF
Attachment_2_-_Drawings_-_16_Nov_17_Part3.pdf PDF
Attachment_2_-_Drawings_-_16_Nov_17_Part2.pdf PDF
Attachment_2_-_Drawings_-_16_Nov_17_Part4.pdf PDF
Attachment_2_-_Drawings_-_16_Nov_17_Part7.pdf PDF
Attachment_6_-_366_SFS_FORM_30_(Request_for_Installation_Entry_Pass)_2.pdf PDF
Attachment_2_-_Drawings_-_16_Nov_17.pdf PDF
Attachment_4_-_Certificate_of_Insurance.pdf PDF
Attachment_1_-_Specifications_-_Nov_17.pdf PDF
Attachment_3_-_Wage_Determination_-_5_Apr_19.pdf PDF
Solicitation_-_FA489719BA007.pdf PDF
Attachment_5_-_Grand_View_Gate_Information.pdf PDF
Show all 26

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

EX SSMH E10A

EX SSMH E10

EX SSMH E9

EX LS #12

EX 8" AC

A

B

EX SSMH E18

EX SSMH E17

EX SSMH E16

EX SSMH A1A

EX SSMHA1

EX SSMH A2

EX SSMH D1

EX 24" RCP

EX 24" RCP

P L

A N

S

O

F

A

S

T

A

N D

S

O

B

PP04

S O

L I C

I T

A T

I O

N

N

O

F I L E

N

M

E

D W

N

B

Y

C K

D

B

Y

D E

S I G

N E

D

B

Y

D E

S C

R I P

T I O

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

F I

U M

B E

R

S I Z

E

S U

B M

I T

T E

D

B

Y

P L O

T

S

C A

L E

P

L O

T

D

A T

E

D A

T E

M A

R K

D E

S C

R I P

T I O

N D

A T

E A

P P

R

C

E S

C

E N

M O

U N

T A

I

H

O M

E

A

R

R

C

S

E

I D

A H

O

M O

U N

T A

M

E

A

R

C

S

E

H D

R

E n g i n e e r i n g

I n c

E

P

A R

K C

E N

T E

R

B

L V

D

B O

I S

E

I D

R E

P A

W

N

E S

SHEET OF 14

KEY MAP

NOT TO SCALE

PP03

PP05

PP05

PP04

P P

P P

P P

P P

P P

P P

PP02

N

PLAN

1"=40'

NPLAN

1"=40'

N

B ST

T

H

A

V E

V E

A

S

T

13TH AVE

BLDG 1363BLDG 1364BLDG 1365

BLDG 1300

FLOW

FLOW

F L O

W

INSTALL CIPP LINER IN EXISTING PIPE, SEE TABLE BELOW

CONSTRUCTION NOTES

NOTES:

1. CONTRACTOR SHALL REINSTATE SERVICE LATERALS PER SPECIFICATION

SECTION 33 01 30.72.

2. CONTRACTOR SHALL PROVIDE BYPASS PUMPING PLANS PER SPECIFICATION

SECTION 33 01 30.72.

3. SEE DETAIL 1 SHEET D01 FOR TRENCH DETAIL.

4. CONTRACTOR TO VERIFY EXISTING UTILITY CONFLICTS PRIOR TO BEGINNING

WORK. CONTRACTOR TO POTHOLE EXISTING UTILITIES AS REQUIRED.

5. CONTRACTOR SHALL PERFORM A CCTV INSPECTION OF PIPES PER

SPECIFICATION SECTION 33 01 30.16.

6. CONTRACTOR TO VERIFY LOCATION AND DEPTH OF POINT REPAIRS.

PIPE POINT REPAIR, SEE TABLE BELOW

A

B

LIBERATOR ST

11/16/2017

MH17RS_PP01-PP04

File details come from the government source that posted it.