Questions.pdf

PDF 92 KB Posted

Attached to
Physical Access Control System (PACS) Federal contract opportunity
Solicitation number
FA485523Q0067
Issued by
Department of the Air Force Special Operations Command

About this file

This document contains questions and answers regarding a physical access control system (PACS) solicitation for the Department of the Air Force Special Operations Command. The solicitation requests installation of a new PACS to control access to four doors at an Air Force facility, including three double leaf doors and one single leaf door. Some existing locking hardware is Trilogy locks but the manufacturer is unknown for all doors. One double leaf door and one single leaf door currently have four-code locks while the other two doors have simple key locks. Magnetic locks are an acceptable option to maintain fail secure status while allowing free egress in emergencies. The preferred location for the system administration computer is at the center squadron desk. As-built drawings of the facility are attached but are not up-to-date. Conduit will be required between each door and the control panel(s) but more construction details are needed to adequately estimate installation costs.

View the file

Other files for this federal contract opportunity

Other files attached to Physical Access Control System (PACS), newest first.
File Type Posted
Questions.pdf PDF
Questions.pdf PDF
Bldg 190 - Office Map.pdf PDF
Attachment 1 - Provisions and Clauses.pdf PDF
Attachment 3 - WD 2015-5457.pdf PDF
Combo Synopsis Solicitation - FA485523Q0067 - PACS.pdf PDF
Attachment 2 - PWS.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PACS Solicita�on Ques�ons

Q: Is each door a single leaf versus a double leaf door?

A: 3 double leaf, one single leaf door.

Q: There is an existing access control system, which means there is existing locking hardware on the doors. What is the manufacturer of the existing system?

A: Some of the locks are Trilogy locks, but I cannot confirm for all of them because there is no outer marking or record of their installation.

Q: What is the locking hardware on the doors?

A: A four-code lock is installed on one double leaf door and one single leaf door and the other two doors have simple key locks.

Q: The gym door looks wider than the other doors, is this an oversized door, an overhead door, or is it a swinging personnel door? Single leaf or double leaf?

A: Double leaf, and not wider than any other door.

Q: Magnetic locks, also referred to as electromagnetic locks are magnets that operate with support from a power supply, which are supposed to drop power to the lock and then open during a fire or life safety emergency. This is considered a “fail safe” or “fail open” condition in order to support free egress during an emergency, allowing exit but also open to entry, which is not preferred in a secure space. Is the use of electric strikes an option in order to maintain “fail secure” status, maintaining security by restricting entry, and at the same time allow free egress during an emergency?

A: Yes.

Q: Where is the preferred location for the PC that will be used for administering the system?

A: The center of the squadron, at what we call the “step desk”

Q: Wiring is to be in conduit, need to know more detail about the construction of this building in order to adequately cost the installation of conduit between each door and the control panel(s). Building plans and drawings would be helpful in this case.

A: Attached is the building plans we have possession of. They are not up to date.

File details come from the government source that posted it. Updated .