FridgeFreezerFAQandPhotos.docx

DOCX document 4 MB Posted

Attached to
Walk In Fridge & Freezer
Solicitation number
FA483025Q0006
Issued by

About this file

This is a FAQ document with photos regarding the replacement of a walk-in cooler/freezer combination unit at Moody Air Force Base. The document provides detailed specifications for a 2-compartment indoor unit measuring 11'W x 29'L x 7'7"H, with the refrigerator section being 17'10" x 11'0" and the freezer section 11'4" x 11'0".

The unit requires 30 AMP power supply for both cooler and freezer sections, features right-swinging doors (34" x 77") with viewing windows, and will be installed on an existing concrete pad. The installation includes internal ramps, and the unit connects to the building's interior near the kitchen area. The scope includes removal and disposal of the existing custom-built unit. Technical specifications detail door components including Component Hardware hinges, Kason hydraulic door closers, and various safety features. The facility operates Monday to Friday 8:00 AM to 5:00 PM, with weekend work possible with 24-hour notice, and the project must be completed by March 2025.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FREQUENTLY ASKED QUESTIONS

Some questions submitted can be answered through pictures provided so they have not been included into this FAQ. Please reference photos attached.

· This walk-in cooler/freezer is for outdoor use, correct?

· NO

· 2 Compartment walk-in refrigerator and 1 freezer unit 11'W x 29'L x 7'7”H

· What is the individual dimension of refrigerator and freezer? Fridge is 17’10’ by 11’0’’; Freezer 11’4’’ by 11’0’’

· Is the existing system a Polar King unit?

· NO

· Can you confirm how do you intend to load product in and out of the unit?

· The units will have ramps internally that attach at the hallway inside the building.

· Is it possible to get a picture of the freezer that is on site right now that needs to be removed?

· YES

· Is there a loading dock?

· YES

· How is access to the facility?

· I’m not sure I understand this question. Where this equipment is attached to the side of the building. When it is removed the building will be exposed to the outside elements.

· Are there any ramps leading to or within the walk-in unit?

· Structure is attached to side of building, entry points are located inside near kitchen area

· What is the distance to the closest existing power source? Unsure how far because assuming power will be shut off in the breaker box where the unit fits in.

· Can you confirm the current amp ratings of the power supply? 30 AMPS cooler, 30 AMPS freezer

· Could you specify the types of items that will be stored in the refrigerator and freezer? This helps in determining temperature settings and other requirements.

· Food and beverage

· While we assume the existing drain and power source size are sufficient, could you confirm this, or provide any known details about these utilities? Will be same size unit, so yes.

· Is the equipment being installed on top of a building?

· NO

· Is the equipment being install outside on the ground?

· Original unit sits on top of concrete pad outside

· If it is how long will the line run be? unknown

· Is this a single-story building?

· YES

· If not, what kind of access do we have to get equipment in? it fits on side of building. When old equipment is removed building will be exposed.

· Union labor or standard: unsure

· What is the exact location of the doors on each compartment?

· 29'-2" [350]

· W22 W23 W24 W25 W26 W4 W5 W6 W7

COOLER

FREEZER

W18 18 7/16 [B]

47 PNL

[A] W17 W16 W15 W14 29 11/16 W13 45 15/16

47 PNL

W12 W11 23 21 3/8

CL

CL

· Do the doors swing to the left or right? right

· Are there any ramps leading to or within the walk-in unit? Yes internal

· What is the distance to the closest existing power source? Unsure. IT hooks to breaker box and not sure how far the next power source will be when this is shut off.

· Could you specify the types of items that will be stored in the refrigerator and freezer? This helps in determining temperature settings and other requirements. Food and beverage

· Do you know how they intend to load product in and out of the unit?

· 1 separate entry points for each unit. 1 for fridge and 1 for freezer

· Do you have the previous drawings for the current walk-in?

· YES, refer photo

· Could you provide the current model number that is getting replaced? Custom built equipment

· Please give confirmation for below:

· Floor or Floorless

· Floor

· Condenser unit inside or outside: outside

· Condenser stands available or need replaced: unsure. Currently sit on building

· Approximate refrigerant line set run.

· Door size and position:

· DOORS: Open from left hand and swing right.

[A]: 34" x 77" flush model G3 self-closing freezer door Brand: Artic Temp Frame: 4" high density urethane (R-32), 3-sided w/ Stucco galvalume both sides w/ 24 ga. stainless steel 430 (magnetic) liners w/ 4-sided heat cable in frame [FL-4-118W] (24'-7" x 5 ohms/ft (123 total) @ 4.8 W/ft + Pepi - 120V, 1A) w/ 3/4" stub-through concealed PVC conduit Leaf: 4" thick, 3-side lap, raised 1/4" w/ Stucco galvalume both sides w/ Magnetic gasket w/ 2 1/4" black neoprene sweep

(2) Component Hardware #W59 spring assisted adjustable hinge

(1) Component Hardware W19 latch (no lock, chrome)

(1) Component Hardware #W28 inside release

(1) Kason #1094 hydraulic door closer (polished chrome)

(1) Weiss 24DT-L, single pole switch and thermometer combo @ ext.

(1) Kason 1825LE heated air vent (4W, 120V, .04A)

(1) 14" x 24" heated (-20F) view window (84W, 120V, 0.9A)

(1) .080 smooth aluminum threshold for interior ramp 36" high AFF .063 aluminum diamond tread (LP) kickplates (leaf, ext. & int.)

[B]: 34" x 77" flush model G3 self-closing cooler door Frame: 4" high density urethane (R-32), 3-sided w/ Stucco galvalume both sides w/ 24 ga. stainless steel 430 (magnetic) liners w/ 3/4" stub-through concealed PVC conduit Leaf: 4" thick, 3-side lap, raised 1/4" w/ Stucco galvalume both sides w/ Magnetic gasket w/ 2 1/4" black neoprene sweep

(2) Component Hardware #W59 spring assisted adjustable hinge

(1) Component Hardware W19 latch (no lock, chrome)

(1) Component Hardware #W28 inside release

(1) Kason #1094 hydraulic door closer (polished chrome)

(1) Weiss 24DT-L, single pole switch and thermometer combo @ ext.

(1) 14" x 24" non-heated view window

(1) .080 smooth aluminum threshold for interior ramp 36" high AFF .063 aluminum diamond tread (LP) kickplates (leaf, ext. & int.)

Fire suppression unit will be shut off during installation and turned back on after completion of install.