Attachment 13_APPENDIX D AsBuilt Drawings EXTEND TYNDALL NCO BEACH BOARDWALK.pdf

PDF 7 MB Posted

Attached to
Extend NCO Beach Boardwalk Federal contract opportunity
Solicitation number
FA481924R0020
Issued by
Department of the Air Force Air Combat Command

About this file

This document contains the as-built drawings for the Extend Tyndall NCO Beach Boardwalk project at Tyndall Air Force Base. The project involves designing and building a 600-foot extension to the existing boardwalk along Tyndall Beach to reduce negative impacts to the dune and surrounding environment caused by personnel accessing the beaches. The new construction is required to match the existing boardwalk design and comply with current building codes, including the DoD Building Code and the High Velocity Hurricane Zone (HVHZ) provisions of the Florida Building Code. The project solicitation number is FA481924R0020, and the work will be performed for the Department of the Air Force Air Combat Command.

View the file

Other files for this federal contract opportunity

Show all 18

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

APPENDIX-D

Boardwalk As-Built Drawings

For

REQUEST FOR PROPOSAL

EXTEND TYNDALL NCO BEACH

BOARDWALK

PROJECT XLWU 25-4009

SHEET

FL LIC# 62663

RYAN A. CLEVELAND, P.E.

with appropriate compensation to CES.

to be in default under this agreement in writing and project by others, unless the Engineer has adjudged additions to this project, or for the completion of this used by the owner or others on other projects, for specifications or any other documents shall not be occupancy of the project. CES's drawings, and reference in connection with the owner's use and specifications and other documents for information including reproducible copies, of CES's drawings, The owner shall be permitted to retain copies, and other reserved rights, including the copyright.

documents and shall retain all common law, statutory provided, CES shall be deemed the author of these with respect to this project and, unless otherwise this project are instruments of CES for use, solely prepared by Ryan A. Cleveland, P.E., P.A. (CES) for

The drawings, specifications, and other documents

R E

V

IS

IO

N S

D A T E

D E S

C R

IP

T

IO

N

DRAWINGS NOT VALID WITHOUT SEAL

Ryan A. Cleveland, P.E., P.A.

423 East Bayou Forest Drive

Freeport, FL 32439 ryancleveland@yahoo.com c 850.200.3399 www.clevelandengineeringservices.com

R E

P A

IR

B

S E

O

A R

D W

A L

K S

SHEET

COVER

TYNDALL AIR FORCE BASE

DEPARTMENT OF THE AIR FORCE

LOCATION

PROJECT

TABLE OF CONTENTS

850-200-3399

FREEPORT, FL 32439

423 EAST BAYOU FOREST DRIVE

RYAN A. CLEVELAND, PE, PA

CLEVELAND ENGINEERING SERVICES

850-283-8643

TYNDALL AFB, FL 32403-5526

BUILDING 647, STOP 28

501 AIREY AVE, SUITE 5

325TH CONTRACTING SQUADRON

850-622-1434

FREEPORT, FL 32439

118 INDUSTRIAL DRIVE

RBM CONTRACTING SERVICES, LLC

Facility #11300 PROJECT No. XLWU 19-8114

TYNDALL BEACH BOARDWALK

T Y

N D

A L

A C

H

T Y

N D

A

F

B

7.S4-BOARDWALK DETAILS

6.S3-BOARDWALK DETAILS

5.S2-BOARDWALK DETAILS

4.S1-BOARDWALK DETAILS

3.C2-SITE PLAN

2.C1-SURVEY/EX. CONDITIONS

1.COVER

CONSTRUCTION DRAWINGS

C O

N S T R

U C

T

IO

N /9 /2

RYAN A. CLEVELAND, P.E.

with appropriate compensation to CES.

to be in default under this agreement in writing and project by others, unless the Engineer has adjudged additions to this project, or for the completion of this used by the owner or others on other projects, for specifications or any other documents shall not be occupancy of the project. CES's drawings, and reference in connection with the owner's use and specifications and other documents for information including reproducible copies, of CES's drawings, The owner shall be permitted to retain copies, and other reserved rights, including the copyright.

documents and shall retain all common law, statutory provided, CES shall be deemed the author of these with respect to this project and, unless otherwise this project are instruments of CES for use, solely prepared by Ryan A. Cleveland, P.E., P.A. (CES) for

The drawings, specifications, and other documents

R E

V

IS

IO

N S

D A T E

D E S

C R

IP

T

IO

N

DRAWINGS NOT VALID WITHOUT SEAL

Ryan A. Cleveland, P.E., P.A.

423 East Bayou Forest Drive

Freeport, FL 32439 ryancleveland@yahoo.com c 850.200.3399 www.clevelandengineeringservices.com

DIRT ROAD

Z O

N E

A E

E L

Z O

N E

V E

E L

BASED ON FLAGS

CENTERLINE

GATE

EL:5.01'

E:1621913.03

N:387104.32

CP#1

SHOWERS

EX. BATHROOM 2.98

2.96

1.20

3.26

2.56

1.50

3.48

3.17

2.72

2.96

2.98

3.05

3.05

3.13

2.85

4.14

4.41

M

AT

CH

L

IN

E

T

TELEPHONE

OLD 911

BASED ON FLAGS

CENTERLINE

4.42

3.87

6.84 10.01

8.28

7.37

5.73

5.30

6.65

3.49

3.34

2.71

3.12

2.93

2.43

2.9

2.9

4 5

6 7

M

AT

CH

L

IN

E

M

AT

CH

L

IN

E

PAVILION TO BE REMOVED

REMNANTS OF OLD

T

Z O

N E

V E

E L

Z O

N E

V E

E L

Z O

N

V

E L

Z O

E L

TELEPHONE

OLD 911

BASED ON FLAGS

CENTERLINE

4.93

5.65

4.53

6.18

2.13

4.88

6.55

4.86

4.20

7.23 5.43

4.82

4.82

3.91

4.51

4.06

3.91

5.28

4.42

3.87

6.84

10.01

8.28

8 7 6 5

T

TELEPHONE

OLD 911

M

AT

CH

L

IN

E

C1

R E

P

A R

D W

A L

K S

T Y

N D

A

A C

H

T Y

N D

A

B

N O R

TH

NO

RT

H

NO

RT

H

1 inch = 30 ft.

( IN FEET )

0 30 60 12030 15

1 inch = 30 ft.

( IN FEET )

0 30 60 12030 15

1 inch = 30 ft.

( IN FEET )

0 30 60 12030 15 CONDITIONS

SURVEY/ EX.

AS SURVEYED 01/19/2021

EXISTING SITE CONDITIONS

AS SURVEYED 01/19/2021

EXISTING SITE CONDITIONS

AS SURVEYED 01/19/2021

EXISTING SITE CONDITIONS

CONSTRUCTION DRAWINGS

C O

N S T R

U C

T

IO

N /9

RYAN A. CLEVELAND, P.E.

with appropriate compensation to CES.

to be in default under this agreement in writing and project by others, unless the Engineer has adjudged additions to this project, or for the completion of this used by the owner or others on other projects, for specifications or any other documents shall not be occupancy of the project. CES's drawings, and reference in connection with the owner's use and specifications and other documents for information including reproducible copies, of CES's drawings, The owner shall be permitted to retain copies, and other reserved rights, including the copyright.

documents and shall retain all common law, statutory provided, CES shall be deemed the author of these with respect to this project and, unless otherwise this project are instruments of CES for use, solely prepared by Ryan A. Cleveland, P.E., P.A. (CES) for

The drawings, specifications, and other documents

R E

V

IS

IO

N S

D A T E

D E S

C R

IP

T

IO

N

DRAWINGS NOT VALID WITHOUT SEAL

Ryan A. Cleveland, P.E., P.A.

423 East Bayou Forest Drive

Freeport, FL 32439 ryancleveland@yahoo.com c 850.200.3399 www.clevelandengineeringservices.com

DIRT ROAD

ON TOPOGRAPHY

CENTERLINE BASED

0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 5+00 5+50 6+00 6+50 7+00 7+50 8+00 8+50

BEARING S10°39'59"W

EL.=4.50'

BEGIN BOARDWALK

STA 0+00

BEARING S10°39'59"W

EL.=4.50'

START 1:12 SLOPE UP

STA 0+24.0

BEARING S10°39'59"W

EL.=6.50'

END SLOPE

STA 0+48.0

BEARING S10°39'59"W

EL.=6.50'

STA 2+00.0

BEARING S10°39'59"W

EL.=6.50'

STA 2+00.0

BEARING S10°39'59"W

EL.=6.50'

STA 2+00.0

EL.=8.50'

DISTANCE=95.0'

RADIUS 226.7'

BEGIN TURN

STA 8+16.0

STA 7+76

START 1:12 SLOPE UP

EL.=6.50'

BEARING S10°39'59"W

BEARING S10°36'59"W

EL.=8.50'

END SLOPE

STA 8+00 2.98

2.96

1.20

3.26

2.56

1.50

3.48

3.17

2.72

2.96

2.98

3.05

3.05

3.13

2.85

4.14

4.41

M

AT

CH

L

IN

E

38+00

8+50 9+00 9+50 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+5014+50

15+00

15+50

16+00

16+50

BEARING S35°41'43"W

EL.=8.50'

END TURN

STA 9+09.0

BEARING N54°18'16"W

EL.=8.50'

START 1:12 SLOPE UP

PAVILION STA 0+00

STA 9+11.5

BEARING N54°18'16"W

EL.=10.50'

END SLOPE

PAVILION STA 0+24

BEARING N35°41'43"E

EL.=10.5'

TURN CL

PAVILION STA 0+27.5

EL.=10.5'

END RAMP

PAVILION STA 0+37.5

BEARING S35°41'43"W

EL.=10.5'

START 1:12 SLOPE DOWN

STA 9+50

BEARING S35°41'43"W

EL.=8.5'

END SLOPE

STA 9+74.0

BEARING S35°41'43"W

EL.=8.5'

START 1:12 SLOPE DOWN

STA 9+82.0

BEARING S35°41'43"W

EL.=6.5'

END SLOPE

STA 10+06.0

BEARING S37°41'43"W

EL.=6.5'

TURN 2°

STA 12+05.9

EL.=8.'

LENGTH=55.5'

RADIUS=231.5

BEGIN TURN

STA 14+13.9

BEARING S37°41'43"W

EL.=6.5'

START 1:12 SLOPE UP

STA 13+01.9

BEARING S37°41'43"W

EL.=8.5'

END SLOPE

STA 13+25.9

BEARING S9°41'43"W

EL.=8.5'

END TURN

STA 14+69.3

BEARING S49°41'43"W

EL.=8.5'

START 1:12 SLOPE UP

STA 14+77.3

BEARING S49°41'43"W

EL.=10.5'

END SLOPE

STA 15+01.3

BEARING S49°41'43"W

EL.=8.5'

START 1:12 SLOPE UP

STA 15+09.3

BEARING S49°41'43"W

EL.=12.5'

END SLOPE

STA 15+33.3

10.01

8.28

7.37

5.73

5.30

6.65

3.49

3.34

2.71

3.12

2.93

2.43

2.9

2.9

M

AT

CH

L

IN

E

T

Z O

N E

V E

E L

Z O

N E

V E

E L

Z O

E L

Z O

E L

8 7 6

16+50 17+00 17+50 18+00 18+50 19+00 19+50 20+00 20+50 21+00 21+50

22+00 22+50

23+00 23+50

24+00

EL.=8.5'

LENGTH=15.8'

RADIUS=226.5'

START TURN

STA 17+17.3

BEARING S49°41'43"W

EL.=12.5'

START 1:12 SLOPE DOWN

STA 16+61.3

BEARING S49°41'43"W

EL.=10.5'

END SLOPE

STA 16+85.3

BEARING S45°41'43"W

EL.=8.5'

END TURN

STA 17+33.1

EL.=8.5'

TELEPHONE STA

STA 17+9.2

EL.=8.5'

LENGTH=15.8'

RADIUS=226.5'

START TURN

STA 18+85.1

BEARING S49°41'43"W

EL.=8.5'

END TURN

STA 19+00.9

EL.=8.5'

TELEPHONE STA

STA 20+45.1

EL.=8.5'

LENGTH=39.5'

RADIUS=236.1'

START TURN

STA 20+52.9

BEARING S41°41'43"W

EL.=8.5'

END TURN

STA 20+92.5

BEARING S41°41'43"W

EL.=8.5'

START 1:12 SLOPE DOWN

STA 23+08.4

BEARING S49°41'43"W

EL.=6.5'

END SLOPE

STA 23+32.4

BEARING S41°41'43"W

EL.=6.5'

START 1:12 SLOPE DOWN

STA 23+40.4

BEARING S49°41'43"W

EL.=5.2'

END SLOPE

STA 23+56.4

EL.=5.2'

START BENCH

STA 23+64.4

EL.=5.2'

END BENCH

STA 23+80.4

EL.=5.2'

SLOPE 1:20

FOLLOW EX. GRADE

START SLOPE DOWN

STA 23+80.1

EL.=4.0'

END BOARDWALK

STA 24+04.4

4.93

5.65

4.53

6.18

2.13

4.88

6.55

4.86

4.20

7.23 5.43

4.82

4.82

3.91

4.51

4.06

3.91

5.28

4.42

3.87

6.84

10.01

8.28

T

M

AT

CH

L

IN

E

C2

R E

P

A R

D W

A L

K S

T Y

N D

A

A C

H

T Y

N D

A

B

N O R

TH

NO

RT

H

NO

RT

H

1 inch = 30 ft.

( IN FEET )

0 30 60 12030 15

1 inch = 30 ft.

( IN FEET )

0 30 60 12030 15

1 inch = 30 ft.

( IN FEET )

0 30 60 12030 15

SEE SHEET S2

BENCH DETAILS

SEE SHEET S3

PHONE SEATING DETAILSSEE SHEET S3

PHONE SEATING DETAILS

SEE SHEET S7

PAVILION DETAILS

PLAN

SITE

CONSTRUCTION DRAWINGS

C O

N S T R

U C

T

IO

N /9

RYAN A. CLEVELAND, P.E.

with appropriate compensation to CES.

to be in default under this agreement in writing and project by others, unless the Engineer has adjudged additions to this project, or for the completion of this used by the owner or others on other projects, for specifications or any other documents shall not be occupancy of the project. CES's drawings, and reference in connection with the owner's use and specifications and other documents for information including reproducible copies, of CES's drawings, The owner shall be permitted to retain copies, and other reserved rights, including the copyright.

documents and shall retain all common law, statutory provided, CES shall be deemed the author of these with respect to this project and, unless otherwise this project are instruments of CES for use, solely prepared by Ryan A. Cleveland, P.E., P.A. (CES) for

The drawings, specifications, and other documents

R E

V

IS

IO

N S

D A T E

D E S

C R

IP

T

IO

N

DRAWINGS NOT VALID WITHOUT SEAL

Ryan A. Cleveland, P.E., P.A.

423 East Bayou Forest Drive

Freeport, FL 32439 ryancleveland@yahoo.com c 850.200.3399 www.clevelandengineeringservices.com

PANEL

5' CONCRETE

2x6 PT

4x6 PT

1x6 TREX

2X4 PT

2x6 PT

X

P T

2x6 PT

4X6 PT 4X6 PT

8x8 PT

4'-0" 4'-0"

8'-0"

4'-0"

5'-11"

SECTION 2/S1

SECTION 3/S1

FASTENING DETAIL 5/S1

LAG BOLTS

1/2"x7" HD GALV

LAG BOLTS

1/2"x4" HD GALV

1/4"x3" HD GALV

PLATE, 5/8" HOLES

AT END.

SPACE BETWEEN PANELS

ALLOW 1/4"-1/2" MAX

WITH EPOXY, SEE 6-S1, 3 EACH SIDE

ANCHOR OR ALL-THREAD

1/2"x10" HD GALV WEDGE

12' EMBEDMENT MIN

8" TIP PILING

CL

(4) SIMPSON STAINLESS STEEL

SDWS276OOSS 6" SCREWS

JOINT

8x8

4x64x6

CL

4x6

4x6

(2) SIMPSON STAINLESS STEEL

SDWS276OOSS 6" SCREWS

1/2" HD GALV

5" EMBED

4X6 PT

(4) #12X6"SS SCREWS

5'-11"

6'-6"

5'-8"

1/2"x7" HD GALV LAG

8'-0"

7'-10"

IN CENTERLINE.

END TO FACILITATE TURN

FROM PANEL ON EACH

CUT/GRIND 1" WEDGE

S1

DETAILS

BOARDWALK

R E

P

A R

D W

A L

K S

S1

BOARDWALK ELEVATION

SCALE=1"=1'-0"

S1 SCALE=1"=1'-0"

BOARDWALK SECTION

S1 SCALE=1"=1'-0"

BOARDWALK SECTION

S1 SCALE=2"=1'-0"

FASTENING DETAIL

S1 SCALE=2"=1'-0"

FASTENING DETAIL

T Y

N D

A

A C

H

T Y

N D

A

B

S1 SCALE=1"=1'-0"

PANEL CUT DETAIL

CONSTRUCTION DRAWINGS

C O

N S T R

U C

T

IO

N /9

RYAN A. CLEVELAND, P.E.

with appropriate compensation to CES.

to be in default under this agreement in writing and project by others, unless the Engineer has adjudged additions to this project, or for the completion of this used by the owner or others on other projects, for specifications or any other documents shall not be occupancy of the project. CES's drawings, and reference in connection with the owner's use and specifications and other documents for information including reproducible copies, of CES's drawings, The owner shall be permitted to retain copies, and other reserved rights, including the copyright.

documents and shall retain all common law, statutory provided, CES shall be deemed the author of these with respect to this project and, unless otherwise this project are instruments of CES for use, solely prepared by Ryan A. Cleveland, P.E., P.A. (CES) for

The drawings, specifications, and other documents

R E

V

IS

IO

N S

D A T E

D E S

C R

IP

T

IO

N

DRAWINGS NOT VALID WITHOUT SEAL

Ryan A. Cleveland, P.E., P.A.

423 East Bayou Forest Drive

Freeport, FL 32439 ryancleveland@yahoo.com c 850.200.3399 www.clevelandengineeringservices.com

2X PT

4X6 PT POSTS

1/2" GALV BOLTS

2X BRACING

2X BRACING

2X SEAT

BRACING

4X4 PT BRACING

4X4 PT

PLATE EACH SIDE

1/4"X3" GALV

PLATE EACH SIDE

1/4"X3" GALV 1/2" GALV BOLT

BRACING

4X4 PT

2X BACKREST

1X8 TREX CAP1X8 TREX CAP1X6 TREX CAP

TYP 2X RAIL

CONCRETE DECK PANEL

WITH EPOXY, SEE 6-S1

ANCHOR OR ALL-THREAD

1/2"x10" HD GALV WEDGE

4X6 PT POSTS TYP 2X RAIL

BETWEEN PANELS

1/4"-1/2" SPACE

4x6 PT POST, TYP.

4x6 PT POST, TYP.

WITH EPOXY, SEE 6-S1, 3 EACH SIDE

ANCHOR OR ALL-THREAD

1/2"x10" HD GALV WEDGE

BETWEEN PANELS

1/4"-1/2" SPACE

BETWEEN PANELS

1/4"-1/2" SPACE

MATERIAL, TYP.

2X PT RAIL

MATERIAL, TYP.

2X PT RAIL

5'-11"

3 EACH SIDE

WITH EPOXY, SEE 6-S1,

ANCHOR OR ALL-THREAD

1/2"x10" HD GALV WEDGE

S2

DETAILS

BOARDWALK

R E

P

A R

D W

A L

K S

S2

SEATING PLAN/SECTIONS

S2 SCALE=1"=1'-0"

TYPICAL BOARDWALK PLAN

T Y

N D

A

A C

H

T Y

N D

A

B

SCALE=1 1/2"=1'-0"

CONSTRUCTION DRAWINGS

C O

N S T R

U C

T

IO

N /9

RYAN A. CLEVELAND, P.E.

with appropriate compensation to CES.

to be in default under this agreement in writing and project by others, unless the Engineer has adjudged additions to this project, or for the completion of this used by the owner or others on other projects, for specifications or any other documents shall not be occupancy of the project. CES's drawings, and reference in connection with the owner's use and specifications and other documents for information including reproducible copies, of CES's drawings, The owner shall be permitted to retain copies, and other reserved rights, including the copyright.

documents and shall retain all common law, statutory provided, CES shall be deemed the author of these with respect to this project and, unless otherwise this project are instruments of CES for use, solely prepared by Ryan A. Cleveland, P.E., P.A. (CES) for

The drawings, specifications, and other documents

R E

V

IS

IO

N S

D A T E

D E S

C R

IP

T

IO

N

DRAWINGS NOT VALID WITHOUT SEAL

Ryan A. Cleveland, P.E., P.A.

423 East Bayou Forest Drive

Freeport, FL 32439 ryancleveland@yahoo.com c 850.200.3399 www.clevelandengineeringservices.com

5'-0"

5'-0"

#3 BARS T&B

#3 BARS T&B

(1)#3 BAR BOT.

(2)#3 BARS TOP

#3 BARS T&B

DISTANCE FOR REBAR

1 1/4" EDGE

TYPICAL SEATING

TYPICAL SEATING

INSTALL PHONE

UP TO 8' ABOVE DECK

EXTEND 6X6 POST

GIRDER

TYPICAL

S3

DETAILS

BOARDWALK

R E

P

A R

D W

A L

K

S3 SCALE=1"=1'-0"

TYPICAL PHONE STATION

T Y

N D

A

A C

H

T Y

N D

A

B

S3

CONCRETE DETAILS

SCALE=1 1/2"=1'-0"

SEE 2/S2

SEE 2/S2

CONSTRUCTION DRAWINGS

C O

N S T R

U C

T

IO

N /9

RYAN A. CLEVELAND, P.E.

with appropriate compensation to CES.

to be in default under this agreement in writing and project by others, unless the Engineer has adjudged additions to this project, or for the completion of this used by the owner or others on other projects, for specifications or any other documents shall not be occupancy of the project. CES's drawings, and reference in connection with the owner's use and specifications and other documents for information including reproducible copies, of CES's drawings, The owner shall be permitted to retain copies, and other reserved rights, including the copyright.

documents and shall retain all common law, statutory provided, CES shall be deemed the author of these with respect to this project and, unless otherwise this project are instruments of CES for use, solely prepared by Ryan A. Cleveland, P.E., P.A. (CES) for

The drawings, specifications, and other documents

R E

V

IS

IO

N S

D A T E

D E S

C R

IP

T

IO

N

DRAWINGS NOT VALID WITHOUT SEAL

Ryan A. Cleveland, P.E., P.A.

423 East Bayou Forest Drive

Freeport, FL 32439 ryancleveland@yahoo.com c 850.200.3399 www.clevelandengineeringservices.com

8" 8"7'-8"7'-8"

8'-4" 10"4'-0"3'-6"

4'-2" 8'-0"8'-0"8'-0"

3'-6"

7'-8"

FULLY CONNECTED

(3)2X12 PT

16" O.C., TYP.

2X8 PT RAFTER

TIE, 3 EACH

(2)2X8 PT COLLAR

FULLY CONNECTED

(2)2X10 PT

BOLTS, TYP.

(2)1/2" HD GALV.

CONCRETE DECK PANELCONCRETE DECK PANEL

8X8 PT GIRDER

ALL-THREAD, TYP.

ENDS, (2) 3/4" HDGALV

OUTSIDE PILING AT

BOLT GIRDER TO

PLATE, TYP.

(2) 1/4"X3"X14" GALV

1/2" BOLTS, TYP.

PILING, TYP.

8" TIP ROUND

TO BOARDWALK

CONCRETE SIM.

BOLT 4X6 TO

PLATE, TYP.

(2) 1/4"X3"X14" GALV

TO BOARDWALK

CONCRETE SIM.

BOLT 4X6 TO

PLATE, TYP.

(2) 1/4"X3"X14" GALV

GIRDER

MITER CUT

SLOPE 1:12 UP

FLAT

FLAT

15' MIN EMBEDMENT

8" TIP PILING

15' MIN EMBEDMENT

8" TIP PILING

1/2" BOLTS, TYP

2X10 PT RIDGE

TIE, 3 EACH

(2)2X8 PT COLLAR

EACH RAFTER

SIMPSON H10A

TYP. EACH RAFTER

RIDGE/RAFTER TIE,

SIMPSON RR

SEE DETAIL 3/S4

GIRDER END PLATE

4:12

4:12 4:12

1'-6"

1'-6"

PILINGS BELOW FLOOR

PILINGS BELOW FLOOR

WITH 8D RS GALV NAILS.

NAILED 6" O.C. FIELD, 4"O.C. EDGE

0.032. TYP., OVER 5/8" CDX PLYWOOD

STANDING SEAM ALUMINUM ROOFING,

1 1/2 " 1"5 1/2 "4"

1'-0"

1'-6"

4X6 PT

SIDE OF 4X6

2X4 PT EACH

4X6 PT

2X PT

18" HIGH BENCH SEAT, TYP.

18" HIGH BENCH SEAT, TYP.

BOLT 4X6 TO PILING

FOR BRACE SUPPORT

BOLT 4X6 TO PILING

FOR BRACE SUPPORT

ONLY

HANDRAIL

TYPICAL

ONLY

HANDRAIL

TYPICAL

S4

DETAILS

BOARDWALK

R E

P

A R

D W

A L

K

S4

T Y

N D

A

A C

H

T Y

N D

A

B

PAVILION PLAN

SCALE=1/2"=1'-0"

S4

PAVILION ROOF

SCALE=1/2"=1'-0"

CONSTRUCTION MATERIALS

TO FINAL SIZE.

SHALL BE DONE AFTER HOLES ARE PUNCHED/DRILLED AND MATERIALS IS CUT

MIN 1/4" THICK, HEAVY DUTY (DOUBLE-DIP) GALVANIZED. ALL GALVANIZING

PLATE CONNECTORS: STEEL PLATE CONNECTORS, BRACKETS, ETC. SHALL BE

GALVANIZED.

ETC. GREATER THAN 1/4" IN DIAMETER SHALL BE HEAVY DUTY (DOUBLE-DIP)

BOLTS/ANCHORS: BOLTS, THREADED ROD, WEDGE ANCHORS, ALL-THREAD RODS,

STEEL, ASTM GRADE 316.

ALL SCREWS 1/4" IN DIAMETER AND SMALLER SHALL BE STAINLESSSCREWS:

BE AS FOLLOWS:

FASTENERS USED IN THE CONSTRUCTION OF THE ELEVATED BOARDWALKS SHALL3.

REINFORCING: ASTM A615 GRADE 60, Fy=60,000 PSI

CONCRETE: MIN 5,000 PSI AT 28 DAYS

SHALL BE AS FOLLOWS:

MATERIALS USED IN THE CONSTRUCTION OF ELEVATED DECK PANELS2.

ACCORDING TO DETAILS.

HANDRAIL TOP CAP: TREX OR SIMILAR COMPOSITE DECKING MATERIAL, SIZED

0.40 ACQ.

PINE, SIZED ACCORDING TO DETAILS. PRESSURE TREATMENT SHALL BE

HORIZONTAL HANDRAIL COMPONENTS: PRESSURE TREATED SOUTHERN YELLOW

TO DETAILS. PRESSURE TREATMENT SHALL BE 0.60 ACQ.

HANDRAIL POSTS: PRESSURE TREATED SOUTHERN YELLOW PINE, SIZED ACCORDING

TO DETAILS. PRESSURE TREATMENT SHALL BE 0.60 ACQ

EDGE BEAM: PRESSURE TREATED SOUTHERN YELLOW PINE, SIZED ACCORDING

DETAILS. PRESSURE TREATEMENT SHALL BE 0.60 CCA.

PRESSURE TREATED SOUTHERN YELLOW PINE, SIZED ACCORDING TOGIRDERS:

ELEVATIONS. PRESSURE TREATMENT SHALL BE 0.80 CCA.

FOR 12' EMBEDMENT DEPTH AND EXPOSED TO MEET REQUIRED FINISH

PRESSURE TREATED SOUTHERN YELLOW PINE, SIZED AS REQUIRED PILINGS:

BELOW:

AS FOLLOWS, OR ACCORDING TO SPECIFIC DETAILS IN DRAWINGS IF NOT LISTED

LUMBER MATERIALS USED IN THE CONSTRUCTION OF THIS PROJECT SHALL BE 1.

MUST LAND ON A VERTICAL POST OR BRACE.

SIDE AND IN VERTICAL COMPARISON. ALL JOINTS IN HORIZONTAL MEMBERS

HORIZONTAL GUARDRAILS, ETC. SHALL HAVE JOINTS STAGGERED FROM SIDE TO

ALL JOINTS IN HORIZONTAL WOOD MEMBERS, I.E. EDGE BEAMS, HANDRAILS,7.

THAN 1/2" DEEP INTO GIRDER.

MAY REQUIRE TRIMMING TO FLUSH PANEL SURFACES. DO NOT CUT MORE

WHERE WALKWAYS TRANSITION FROM SLOPE TO FLAT, THE GIRDER CORNERS 7.

CUTTING SLOPE IN THE TOP OF THE PILING.

WHERE CONCRETE PANELS SLOPE, THE GIRDER MUST ALSO BE SLOPED BY6.

LOCATION IS DESIRED IN LIEU OF SHIMMING.

REMOVING SMALL AMOUNTS OF WOOD FROM THE GIRDER AT BEARING

GIRDERS, COMPOSITE PLASTIC SHIMS SHOULD BE USED. WHEN NECESSARY,

WIDTH OF 2". IF PANELS REQUIRE SHIMMING DUE TO UNEVENESS IN WOOD

CONCRETE PANELS SHALL BE SET IN PLACE WITH A MINIMUM END-BEARING5.

SECTION WITH CONCRETE PANELS IN PLACE.

CONTRACTOR SHOULD NOT VIBRATE PILINGS WITHIN 50' OF A FINISHED DECK 4.

THE PILING SHOULD BE VIBRATED TO FINAL DEPTH OF A MIN. 12' EMBEDMENT.

PILING INSTALLATION SHALL BE CARRIED OUT VIA WATER JETTING OR AUGER.3.

GRASSES, ETC.

BE EXECUTED SO AS TO MINIMIZE DISTURBANCE TO VEGETATION, DUNES,

ACCESSING THE WORK LOCATION ALONG THE PROJECT CENTERLINE SHOULD 2.

ENSURE MATERIALS AND EQUIPMENT ARE STORED IN THE PROPER LOCATION.

THE CONTRACTOR SHALL COORDINATE WITH TYNDALL AFB STAFF TO 1.

EXECUTION OF WORK

GIRDER END PLATE

SCALE=1"=1'-0"

C O

N S T R

U C

T

IO

N /9 /2

CONSTRUCTION DRAWINGS

PAVILION SEATING

SCALE=1/2"=1'-0"

10.

D.

C.

4.

SUBMITTED, AND APPROVED, IF NECESSARY, PRIOR TO PLACEMENT WITHIN THE PROJECT LIMITS.

LIMITS. A SAMPLE OF BACKFILL MATERIAL SHOULD BE OBTAINED, WITH JURISDICTION WITHIN THE PROJECT

ALL BACKFILL MATERIALS SHALL BE APPROVED FOR USE BY FDEP, COUNTY OR FEDERAL REGULATORY AGENCY 3.

DISTURB THESE AREAS.

AWARE OF ANY SENSITIVE LANDS, VEGETATION, OR HABITAT AND TAKE NECESSARY PRECAUTION NOT TO

REQUIRED WHEN WORKING WITHIN THE COASTAL AREAS WITHIN THE PROJECT LIMITS. CONTRACTOR SHOULD BE

CONTRACTOR SHALL COMPLY WITH ALL STATE AND FEDERAL PERMITTING AND CONSTRUCTION GUIDELINES 2.

BASE PROJECT NUMBER: XLWU 19-8114.

ACCORDING TO THE STATEMENT OF WORK; REPAIR BASE BOARDWALKS; TYNDALL AFB FLORIDA;

CONTRACTOR SHALL FOLLOW ALL CONSTRUCTION GUIDELINES AS REQUIRED BY TYNDALL AIR FORCE BASE, 1.

COMPLIANCE WITH FEDERAL, STATE, AND LOCAL LAWS AND REGULATIONS FOR STORAGE AND HANDLING OF THESE MATERIALS.

INTENDED ACTIONS TO PREVENT INTRODUCTION OF SUCH MATERIALS INTO THE AIR, WATER, OR GROUND; AND DETAILS PROVISIONS FOR

A CONTAMINANT PREVENTION PLAN THAT: IDENTIFIES POTENTIALLY HAZARDOUS SUBSTANCES TO BE USED ON THE JOB SITE; IDENTIFIES THE 11.

AIR BORNE (FUGITIVE EMISSIONS) AND TRAVEL OFF THE PROJECT SITE.

AN AIR POLLUTION CONTROL PLAN DETAILING PROVISIONS TO ASSURE THAT DUST, DEBRIS, MATERIALS, TRASH, ETC., DO NOT BECOME

AND LOCAL GOVERNMENT SPONSORED RECYCLING PROGRAMS TO REDUCE THE VOLUME OF SOLID WASTE AT THE SOURCE.

RESOURCES. DETAIL IN THE PLAN THE CONTRACTOR'S ACTIONS TO COMPLY WITH AND TO PARTICIPATE IN FEDERAL, STATE, REGIONAL, A RECYCLING AND SOLID WASTE MINIMIZATION PLAN WITH A LIST OF MEASURES TO REDUCE CONSUMPTION OF ENERGY AND NATURAL

TONS ALONG WITH THE PERCENT THAT WAS DIVERTED.

INDICATE IN THE REPORT THE TOTAL AMOUNT OF WASTE GENERATED AND TOTAL AMOUNT OF WASTE DIVERTED IN CUBIC YARDS OR

DISPOSED AND/OR DIVERTED (E.G. THE FIRST WORKING DAY OF JANUARY, APRIL, JULY, AND OCTOBER).

FOR THE PREVIOUS QUARTER ON THE FIRST WORKING DAY AFTER THE FIRST QUARTER THAT NON- HAZARDOUS SOLID WASTE HAS BEEN

ATTACH A COPY OF EACH OF THE NON- HAZARDOUS SOLID WASTE DIVERSION REPORTS TO THE DISPOSAL PLAN. SUBMIT THE REPORT

EVIDENCE OF THE DISPOSAL FACILITY'S ACCEPTANCE OF THE SOLID WASTE MUST BE ATTACHED TO THIS PLAN DURING THE CONSTRUCTION. B.

ARE NOT A COMMERCIAL OPERATING FACILITY.PERMITS FOR SOLID WASTE DISPOSAL SITES THAT

IDENTIFY ANY SUBCONTRACTORS RESPONSIBLE FOR THE TRANSPORTATION AND DISPOSAL OF SOLID WASTE. SUBMIT LICENSES OR A.

BY THIS CONTRACT.

TO CONDUCT AND RECORD HAZARDOUS WASTE DETERMINATIONS THAT COMPLY WITH 40 CFR262.11 FOR ALL SOLID WASTES GENERATED

DEBRIS AND SCHEDULES FOR DISPOSAL. THE NON-HAZARDOUS SOLID WASTE DISPOSAL PLAN MUST DESCRIBE THE METHODS USED

A NON-HAZARDOUS SOLID WASTE DISPOSAL PLAN IDENTIFYING METHODS AND LOCATIONS FOR SOLID WASTE DISPOSAL INCLUDING CLEARING 9.

CALL 850-283-3000 OR 850-283-3001.

DIG PERMITS MUST BE APPROVED/ISSUED BY TAFB 325CES CUSTOMER SERVICE OFFICE PRIOR TO COMMENCEMENT OF WORK. 8.

BE RESPONSIBLE TO ENSURE ALL SUB-CONTRACTORS COMPLY WITH THIS SECTION.

CEIEC TO THE CONTRACTING OFFICE BEFORE THE MATERIAL CAN BE BROUGHT ONTO THE INSTALLATION. PRIME CONTRACTORS SHALL

SUBMITTAL MONTHLY AND/OR COMPLETION. THE TAFB FORM 82.AN UP-DATED LETTER OF REVIEW INDICATING CHANGES WILL BE SENT FROM

SHOWING MATERIAL USAGE MONTHLY UNTIL COMPLETION OF THE TASK ORDER. A LETTER FROM CEIEC WILL BE ACCOMPLISHED WITH EACH

ANY SPECIAL INSTRUCTIONS. AS DIRECTED BY THE CO, THE CONTRACTOR IS REQUIRED TO SUBMIT TAFB FORM 83 (REPORTING ENTRY FORM)

AFTER SUBMISSION, 325 CES/CEIE WILL NOTIFY THE PROJECT MANAGER AND/OR CONS OF THE REPORTABLE CHEMICALS AND OF 7.

ALSO BE READILY ACCESSIBLE AT THE LOCATION OF EACH HAZARDOUS MATERIAL.

COPIES OF MANUFACTURER-SPECIFIC SAFETY DATA SHEETS (SDS) MUST BE ATTACHED TO TAFB FORM 82. THESE SDSS SHALL

ADHESIVES, AEROSOL CANS, SEALANTS, PAINTS, LUBRICANTS, OILS, CLEANERS, DEGREASERS, PESTICIDES, FUELS.

SHOULD NOTE THAT TYNDALL AFB IS REQUIRED TO REPORT CHEMICALS USED SUCH AS (BUT NOT LIMITED TO) COMPRESSED GASES, IF APPLICABLE (WITHIN 10 DUTY DAYS AFTER THE NOTICE TO PROCEED IS ISSUED), FOR REVIEW. THE CONTRACTOR

THE CONTRACTOR SHALL SUBMIT TAFB FORM 81 (CONTRACTOR QUESTIONNAIRE) AND TAFB FORM 82 (CHEMICAL INVENTORY) 6.

TASK ORDER. B.

A LETTER OF REVIEW FROM 325 CES/CEIEC MUST BE ACCOMPLISHED PRIOR TO COMMENCEMENT OF WORK ON EACH 5.

MANAGER (BOB MYERS 850-896-6449) PRIOR TO THE START OF THE PROJECT.WITH THE TYNDALL RECYCLING CENTER

TO THE TYNDALL RECYCLING CENTER. THE CONTACTOR SHOULD COORDINATE THE COLLECTION OF SCRAP METAL

FOR RECYCLING. METALS THAT CAN BE SEPARATED FROM OTHER CONSTRUCTION DEBRIS SHALL BE TURNED IN

METALS THAT CAN BE SEPARATED FROM OTHER CONSTRUCTION DEBRIS SHALL BE TURNED IN TO 325 CES/CEV

APPENDIX D AsBuilt Drawings EXTEND TYNDALL NCO BEACH BOARDWALK