This document is a detailed architectural wall design drawing (F. 703 Wall Detail, SK-1) dated 08/22/25, providing a comprehensive technical elevation and plan view of a masonry wall construction. The drawing specifies critical technical specifications including:
Key technical details include a 16'-0" long wall with precise dimensional annotations, featuring 4" precast concrete cap with sloped top and drips, masonry horizontal reinforcing (Durawel or equivalent, 16" o.c.), and #4 rebar reinforcement. Specific foundation requirements mandate a minimum 12" thick footer or matching existing conditions, with foundation grade set minimum 18" below existing grade. Detailed notes instruct the contractor to verify all dimensions in the field and inspect existing foundation, with a specification to match existing face brick at 4" CMU.
View the file
Other files for this federal contract opportunity
Show all 14
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ELEVATION
1/2"=1'-0"
08/22/25
PLAN
1/2"=1'-0"
AutoCAD SHX Text 17'-9"
AutoCAD SHX Text
4" PRECAST CCONCRETE CAP W/ " SLOPED TOP + 14" SLOPED TOP + DRIPS
AutoCAD SHX Text
FOUNDATION MINIMUM 18" BELOW GRADE OR MATCH EXISTING
AutoCAD SHX Text NOTES: 1. ALL DIMENSIONS TO BE VERIFIED IN FIELD BY CONTRACTOR 2. INSPECT EXISTING FOUNDATION, REUSE IF POSSIBLE
AutoCAD SHX Text
FACE BRICK TO MATCH EXISTING
AutoCAD SHX Text
4" CMU
AutoCAD SHX Text 1'-9"
AutoCAD SHX Text 1'-9"
AutoCAD SHX Text 16'-0"
AutoCAD SHX Text 8'-4"
AutoCAD SHX Text 7'-0"
AutoCAD SHX Text
FOOTER MINIMUM 12" THICK OR MATCH EXISTING
AutoCAD SHX Text
MASONRY HORIZONTAL REINFORCING, DUROWALL OR EQUAL, 16" O.C.
AutoCAD SHX Text
#4 REBAR @ 24" O.C. GROUT SOLID
AutoCAD SHX Text
3 #4 REBAR
AutoCAD SHX Text
(2) #4 REBAR#4 REBAR
AutoCAD SHX Text 2'-9"
AutoCAD SHX Text 2'-9"
AutoCAD SHX Text 2'-0"