This asbestos inspection report documents the results of testing building materials in Building 2116 at Fort Eustis, Virginia for the presence of asbestos. Suspect asbestos containing materials identified include the roof membrane, roof curb flashing, roof vent, roof parapet flashing, door caulk, window caulk, window glaze, boiler insulation, tank insulation, pipe sealer, block sealer, and concrete. Bulk samples were collected from these materials and analyzed by polarized light microscopy. The results are contained in the report, which was prepared for Guernsey Tingle Architects to comply with asbestos regulations in advance of renovation work at the property.

A related federal contract opportunity posted by the Department of the Air Force Air Combat Command is soliciting proposals for a multi building demolition project at Fort Eustis. Offerors are advised to review the attached documentation for additional requirement details. The solicitation number is FA480019QA025 and is titled the Fort Eustis Multi Building Demolition Project.

2116 ASBESTOS REPORT

View the file

Other files for this federal contract opportunity

Other files attached to Fort Eustis Multi Building Demolition Project, newest first.
File Type Posted
FE_2110_2113_2114_2115_Architectural_1st_Floor_New_Work_2_of_2.tif TIF image
FE_2116_Flr_Pln_&_Det,___.tif TIF image
FE_2799_REPAIR_DEMO_AND_NEW_WORK_PLANS_1_OF_4.tif TIF image
FortEustis_2783_1-Layout1.pdf PDF
FortEustis_2113_3.pdf PDF
FortEustis_2113_1.pdf PDF
FortEustis_2114_3.pdf PDF
FortEustis_2799.pdf PDF
FortEustis_801.pdf PDF
FortEustis_2116.pdf PDF
FortEustis_2783.pdf PDF
FortEustis_2113_B1.pdf PDF
FortEustis_2731.pdf PDF
FortEustis_2785.pdf PDF
FortEustis_2114_2.dwg DWG drawing
2116_Cover_Letter.pdf PDF
FortEustis_2799_1.dwg DWG drawing
801_Hazmat_Letter.pdf PDF
FortEustis_2794_1.dwg DWG drawing
2799_Pb_Inspection.pdf PDF
2785_Asbestos_Report.pdf PDF
FortEustis_2114_B1.dwg DWG drawing
FortEustis_2114_3.dwg DWG drawing
FortEustis_2116_1.dwg DWG drawing
9Bldg_CTO_Demo_Site_Plans.pdf PDF
2783_Hazmat_Letter.pdf PDF
FortEustis_801_1.dwg DWG drawing
FortEustis_2113_B1.dwg DWG drawing
2794_Asbestos_Report.pdf PDF
2785_Asbestos_Report.pdf PDF
2794_Cover_Letter.pdf PDF
FE_2116_Flr_Pln_&_Det,___.tif TIF image
FortEustis_2113_2.dwg DWG drawing
2785_Hazmat_Letter.pdf PDF
2799_Cover_Letter.pdf PDF
FA480019QA025.docx DOCX document
2794_Pb_Inspection.pdf PDF
EMP_4.4.6.16_Tab_1_JBLE-Eustis_Assessment_Management_Special_Conditions_and_Affirmative_Procurement.docx DOCX document
801_Asbestos_Report.pdf PDF
FA480019QA025.docx DOCX document
HERT_18-9002-Bldgs_2113,2114,2116_Part4_Part1.pdf PDF
HERT_13-9003_Demo_Central_Heat_Plant_f332.pdf PDF
HERT_18-9002-Bldgs_2113,2114,2116_Part3.pdf PDF
HERT_18-9002-Bldgs_2113,2114,2116_Part2_Part1.pdf PDF
HERT_13-9006_Demolish_Bldgs_2731-2783-85-94-99_Part3.pdf PDF
HERT_13-9006_Demolish_Bldgs_2731-2783-85-94-99_Part2_Part1.pdf PDF
HERT_18-9002-Bldgs_2113,2114,2116_Part1.pdf PDF
HERT_18-9002-Bldgs_2113,2114,2116_Part4_Part3.pdf PDF
HERT_18-9002-Bldgs_2113,2114,2116_Part2_Part2.pdf PDF
FA480019QA025.docx DOCX document
Show all 50

Fort Eustis Multi Building Demolition Project has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ASBESTOS INSPECTION REPORT

OF

BUILDING 2116

FORT EUSTIS, VIRGINIA

MCS JOB # 17-106S

Marine Chemist Service, Inc.

11850 Tug Boat Lane, Newport News, VA 23606-2527

Phone: (757) 873-0933 · Norfolk (757) 640-1122 Fax: (757) 873-1074 · Norfolk (757) 625-5696 www.MarineChemist.com

Asbestos Inspection Report of

Building 2116 Fort Eustis, Virginia on

September 13, 2017

Prepared for:

Kevin Panchision Guernsey Tingle Architects

4350 New Town Avenue, Suite 101 Williamsburg, Virginia 23188

MCS Job #17-106S

By

Patrick Studley, CIH Virginia Asbestos Inspector License 3303 003193

Marine Chemist Service, Inc.

11850 Tug Boat Lane

Newport News, Virginia 23606

(757) 873-0933

October 4, 2017 Date Inspector Signature

TABLE OF CONTENTS

SECTION 1 ------------------------------------------------------- Asbestos Inspection Report

SECTION 2 ------------------------------------------------------- Sample Summary Table

SECTION 3 ------------------------------------------------------- General Legend and Notes

SECTION 4 ------------------------------------------------------- ACM Sketches

SECTION 5 ------------------------------------------------------- Survey Sample Location Sketches

SECTION 6 ------------------------------------------------------- Report of Analysis

SECTION 7 ------------------------------------------------------- Inspection Information

SECTION 8 ------------------------------------------------------- Credentials

Guernsey Tingle - Asbestos Report MCS Job #17-106S - Fort Eustis Building 2116

SECTION 1

Asbestos Inspection Report

Guernsey Tingle - Asbestos Report

ASBESTOS INSPECTION OF BUILDING 2116

FORT EUSTIS, VIRGINIA

INTRODUCTION

Background and Purpose

There has been a growing public awareness of the link between the inhalation of asbestos fibers and various diseases such as asbestosis, mesothelioma, lung, and other cancers. As a result, the Asbestos Hazard Emergency Response Act (AHERA 40 CFR Part 763) for schools grades K through 12 was established by EPA.

The necessary components of an AHERA inspection require the accredited inspector to visually inspect and assess the condition of all known or assumed friable asbestos containing building materials (ACBM); to visually inspect non - friable ACBM and touch it to determine friability, and to identify homogeneous areas of friable materials.

EPA’s National Emission Standards for Hazardous Air Pollutants (NESHAPS) require thorough inspections for asbestos in structures before the renovation or demolition of those structures.

Virginia law requires that if the initial building permit was issued prior to January 1, 1985, an asbestos inspection must be performed prior to the local authorities issuing a building permit.

In order to comply with NESHAPS, buildings to be renovated or demolished must be thoroughly inspected for asbestos containing building materials. Marine Chemist Service, Inc.

follows the AHERA sampling protocol for interior surveys and the Virginia standard for roof surveys.

The purpose of this survey was to provide information for this property concerning the location and type of accessible and/or visible asbestos containing materials prior to renovation.

In compliance with Virginia Regulations, Marine Chemist Service Inc. performed an asbestos survey of Building 2116, located at Fort Eustis, Virginia on September 13, 2017.

Guernsey Tingle - Asbestos Report

General Information

Marine Chemist Service, Inc. was hired by Kevin Panchision of Guernsey Tingle to conduct an asbestos inspection and bulk sampling for suspect asbestos-containing building materials of Building 2116, located at Fort Eustis, Virginia.

Authorization

Authorization to perform this testing was provided by Kevin Panchision, Guernsey Tingle on August 10, 2017. The area was unoccupied at the time of the inspection.

Warranty

This visual inspection and laboratory report has been prepared in accordance with AHERA and Virginia requirements and current accepted professional practices. A minimum number of bulk asbestos samples were collected to determine the presence or absence of asbestos. This inspection has been performed to provide the client with information concerning the presence of accessible and/or exposed suspect asbestos containing building materials. In compliance with the owner’s wishes, destructive testing was not performed. This inspection documents conditions at the time of the inspection only. No other warranties are implied or expressed.

SURVEY METHODS

Inspection Methods

The asbestos survey was performed by Virginia licensed asbestos inspectors. An initial visual walk through inspection was performed to identify suspect asbestos containing materials and homogeneous areas.

All buildings that are part of this survey did not contain crawlspaces. All buildings are slab on grade construction.

Sampling Methods

The Virginia licensed asbestos inspector sampled the identified suspect materials within the homogeneous areas following the visual inspection. Sampling was not performed on any inaccessible materials and did not involve destructive testing of building components. Sample locations were selected randomly but also taken at less visible locations to minimize visible damage.

LABORATORY METHODS

Analysis Methods

The bulk sample was first visually observed and described. The sample was mounted onto a slide, covered with dispersion staining oil and a cover slip, and observed under a polarized light microscope (PLM). The asbestos and non-asbestos materials in the sample are identified by this method.

The PLM microscopist estimates the amounts of asbestos and non-asbestos components by determining visually the relative volume of each to the total volume of the sample.

Guernsey Tingle - Asbestos Report

ASBESTOS INSPECTION

Document Review and On-Site Survey

Blueprints were provided for the inspection. In addition, a sketch was made of the area to indicate sample/asbestos material locations.

Identification of Suspect Asbestos Containing Materials

A visual inspection was performed on the suspect asbestos containing material found in the survey areas. The suspect asbestos containing materials are as follows:

1. Roof Membrane 2. Roof Curb Flashing

3. Roof Vent 4. Roof Parapet Flashing

5. Door Caulk 6. Window Caulk

7. Window Glaze 8. Boiler Insulation

9. Tank Insulation 10. Pipe Sealer

11. Block Sealer 12. Concrete

Bulk Sampling

Bulk sampling was performed on all suspect asbestos-containing materials found in the areas and the minimum number of samples were taken as required in the AHERA Standards.

Bulk samples were taken penetrating all layers of the material. The samples were at least one cubic centimeter and were placed in a sealed container at the time of collection. All precautions were taken to prevent exposure to those present in or around the facility during the collection of samples. All sampling locations were patched with an encapsulant after the sampling was complete.

Samples listed below are grouped into homogeneous areas. Homogeneous areas are areas, which are uniform by color, texture, construction/application date, and general appearance.

Some sample results in the % asbestos column may be displayed in this report with a slash between two numbers, (#/#). The first number represents the first material listed in the laboratory report under the material location/description and the second number represents the second material listed.

When N/A is placed in the friable category it means the sample tested negative - (0) or less than one percent - (<1%) for asbestos and the friable description does not apply.

Samples were analyzed utilizing Polarized Light Microscopy (PLM) with dispersion staining by a NVLAP accredited laboratory (Marine Chemist Service, Inc. NVLAP Lab Code 200628-0).

The results are in section 6.

Guernsey Tingle - Asbestos Report

SECTION 2

Sample Summary Table

Sample

# Lab Sample # Material Location and Description

Asbestos

Friable

Y/N

2116-1 0119781-001 Upper Roof, Membrane 0 N/A

2116-2 0119781-002 Upper Roof, Membrane 0/0 N/A

2116-3 0119781-003 Upper Roof, Membrane 0/0 N/A

2116-4 0119781-004 Upper Roof, Curb Flashing 10/0 N

2116-5 0119781-005 Upper Roof, Curb Flashing 3/0 N

2116-6 0119781-006 Lower Roof, Membrane 0/0 N/A

2116-7 0119781-007 Lower Roof, Membrane 0/0 N/A

2116-8 0119781-008 Lower Roof, Membrane 0/0 N/A

2116-9 0119781-009 Lower Roof, Vent 0/0 N/A

2116-10 0119781-010 Lower Roof, Parapet Flashing 0 N/A

2116-11 0119781-011 Exterior, Door Caulk 0 N/A

2116-12 0119781-012 Exterior, Door Caulk 0 N/A

2116-13 0119781-013 Exterior, Window Caulk 3 N

2116-14 0119781-014 Exterior, Window Caulk 0 N/A

2116-15 0119781-015 Exterior, Window Glaze 0 N/A

2116-16 0119781-016 Exterior, Window Glaze 0 N/A

2116-17 0119781-017 Interior, Boiler Insulation 0 N/A

2116-18 0119781-018 Interior, Boiler Insulation 0 N/A

2116-19 0119781-019 Interior, Boiler Insulation 0/0 N/A

2116-20 0119781-020 Interior, Tank Insulation 0/0 N/A

2116-21 0119781-021 Interior, Tank Insulation 0/0 N/A

2116-22 0119781-022 Interior, Tank Insulation 0/0 N/A

2116-23 0119781-023 Interior, Pipe Sealer 0 N/A

2116-24 0119781-024 Interior, Pipe Sealer 0/0 N/A

2116-25 0119781-025 Interior, Pipe Sealer 0 N/A

2116-26 0119781-026 Interior, Block Sealer 0 N/A

2116-27 0119781-027 Interior, Block Sealer 0 N/A

2116-28 0119781-028 Interior, Concrete 0 N/A

2116-29 0119781-029 Interior, Concrete 0 N/A

Building 2116

Fort Eustis

Guernsey Tingle - Asbestos Report

Comments

1. The following sampled materials tested positive for asbestos:

a. Curb Flashing (Upper Roof)

b. Window Caulk (Exterior)

2. Standard practice for asbestos/nonasbestos material classification is if one sample of a material tests positive, all of the corresponding material throughout the building is assumed to be of the same composition.

3. The Curb Flashing on the Upper Roof is considered a Category I Nonfriable material

(unless rendered friable) and may be removed in a Class II work area by properly trained and qualified personnel

4. The Window Caulk on the Exterior is considered a Category II Nonfriable material

(unless rendered friable) and may be removed in a Class II work area by properly trained and qualified personnel.

5. Asbestos might be found within walls, ceiling and or pipe chases during the renovation or demolition of the building. If any suspect materials are found they should treated as asbestos or tested for asbestos.

Approximate Quantities of Asbestos Materials

ASBESTOS CONTAINING MATERIALS QUANTITY CURRENT

CONDITION

Curb Flashing (Upper Roof) 100 linear ft. Intact Window Caulk (Exterior) 150 linear ft. Intact

SECTION 3

General Legend and Notes

Guernsey Tingle - Asbestos Report

GENERAL LEGEND

O - Sample number/location - non-asbestos

- Sample number/location - contains asbestos

- Door/Doorway

- Window

GENERAL NOTES

1. The EPA definition of a friable material is one that contains more than 1% asbestos by weight and can be crumbled, pulverized or reduced to a powder by hand pressure when dry, or which under normal use or maintenance emits or can be expected to emit asbestos fibers into the air.

2. All quantities are approximate.

3. Sketches are not to scale.

SECTION 4

Asbestos Containing Material Sketches

Asbestos Material Locations Building 2116

Fort Eustis, Virginia

Exterior Window Caulk (Typical)

Guernsey Tingle - Asbestos Report

Asbestos Material Locations Building 2116 Roof Fort Eustis, Virginia

Curb Flashing (Typical)

Guernsey Tingle - Asbestos Report

SECTION 5

Survey Sample Location Sketches

Guernsey Tingle - Asbestos Report

Asbestos Sample Locations Building 2116 Roof Fort Eustis, Virginia

2 3

Guernsey Tingle - Asbestos Report MCS Job #17-106S - Fort Eustis Building 2116

Shannon Oval

Shannon Oval

Shannon Oval

Asbestos Sample Locations Building 2116

Fort Eustis, Virginia

Guernsey Tingle - Asbestos Report

SECTION 6

Reports of Analysis

Guernsey Tingle - Asbestos Report

SECTION 7

Inspection Information

Guernsey Tingle - Asbestos Report

Inspection Information

The survey contractor for the inspection of Building 2116, Fort Eustis, Virginia is:

11850 Tug Boat Lane Newport News, Virginia 23606 www.MarineChemist.com

The team leader responsible for quality control coordination of inspection and adherence to inspection protocol is:

Colleen Becker - CIH

11850 Tug Boat Lane

CBecker@MarineChemist.com

The AIHA and NVLAP Accredited laboratory selected to analyze the bulk samples for asbestos content by PLM, using the "Interim Method for the Determination of Asbestos in Bulk Insulation Samples” (Appendix A to Subpart F in 40 CFR Part 763) is:

Virginia Asbestos Analytical Laboratory License 3333 000004

11850 Tug Boat Lane

(757) 873-0933

The inspector who physically inspected the building and who has received EPA-Approved Training is:

Patrick Studley, CIH

Virginia Asbestos Inspector License 3303 003193 PStudley@MarineChemist.com

The Industrial Hygiene Inspector is employed by:

11850 Tug Boat Lane Newport News, Virginia 23606

(757) 873-0933

Guernsey Tingle - Asbestos Report

SECTION 8

Credentials

Guernsey Tingle - Asbestos Report

This Page May Be Removed Prior to Bid Submittal

BUILDING 2116

ASBESTOS CONTAINING MATERIALS QUANTITY COST

PER UNIT

REMOVAL

COST

Curb Flashing (Upper Roof) 100 linear ft. $ 10.00 $ 1,000.00 Window Caulk (Exterior) 150 linear ft. $ 5.50 $ 825.00

Total $ 1,825.00

*The abatement contractor may require a mobilization fee of approximately $ 1,600.00 in addition to removal costs. Prices may vary depending on volume of abatement that needs to be accomplished, difficulty of set up requirement, work hours, work days, accessibility of materials.