This asbestos inspection report documents the results of an asbestos survey conducted at Building 2785 located at Fort Eustis, Virginia. The inspection identified the following suspect asbestos-containing materials: shingles/tar paper, drywall/joint compound, carpet adhesive, 12-inch floor tile and mastic, 4-inch base cove and adhesive, window caulk, linoleum/backing, 2-foot ceiling tile, 2-foot ceiling tile patch, block sealer, door caulk, window caulk, window glaze, tank insulation, mudded fittings, pipe sealer, duct sealer, vibration cloth, and silver paint. Bulk samples were collected from each homogeneous material area and analyzed to determine the presence or absence of asbestos. The report provides sample locations, results of laboratory analysis, and information on inspection methods.

The related federal contract opportunity is a solicitation for the Fort Eustis Multi Building Demolition Project issued by the Department of the Air Force Air Combat Command. The solicitation seeks demolition services for multiple buildings located at Fort Eustis, Virginia. Offerors should review the attached solicitation document for full details on response requirements, evaluation criteria, and other contractual terms.

2785 ASBESTOS REPORT

View the file

Other files for this federal contract opportunity

Other files attached to Fort Eustis Multi Building Demolition Project, newest first.
File Type Posted
FE_2110_2113_2114_2115_Architectural_1st_Floor_New_Work_2_of_2.tif TIF image
FE_2116_Flr_Pln_&_Det,___.tif TIF image
FE_2799_REPAIR_DEMO_AND_NEW_WORK_PLANS_1_OF_4.tif TIF image
FortEustis_2783_1-Layout1.pdf PDF
FortEustis_2113_1.pdf PDF
FortEustis_2114_3.pdf PDF
FortEustis_2799.pdf PDF
FortEustis_801.pdf PDF
FortEustis_2116.pdf PDF
FortEustis_2783.pdf PDF
FortEustis_2113_B1.pdf PDF
FortEustis_2731.pdf PDF
FortEustis_2785.pdf PDF
2799_Pb_Inspection.pdf PDF
2785_Asbestos_Report.pdf PDF
FortEustis_2114_B1.dwg DWG drawing
FortEustis_2114_3.dwg DWG drawing
FortEustis_2116_1.dwg DWG drawing
9Bldg_CTO_Demo_Site_Plans.pdf PDF
2783_Hazmat_Letter.pdf PDF
FortEustis_801_1.dwg DWG drawing
FortEustis_2113_B1.dwg DWG drawing
2794_Asbestos_Report.pdf PDF
2794_Cover_Letter.pdf PDF
FE_2116_Flr_Pln_&_Det,___.tif TIF image
FortEustis_2113_2.dwg DWG drawing
2785_Hazmat_Letter.pdf PDF
2799_Cover_Letter.pdf PDF
FA480019QA025.docx DOCX document
2794_Pb_Inspection.pdf PDF
EMP_4.4.6.16_Tab_1_JBLE-Eustis_Assessment_Management_Special_Conditions_and_Affirmative_Procurement.docx DOCX document
801_Asbestos_Report.pdf PDF
Qs_plus_RFI_Responses_CTO_9_Bldg_Demo_rev2.doc DOC document
801_Pb_Inspection.pdf PDF
2116_Asbestos_Report.pdf PDF
2785_Pb_Inspection.pdf PDF
FortEustis_2785_1.dwg DWG drawing
2783_Pb_Inspection.pdf PDF
FortEustis_2731_1.dwg DWG drawing
2799_Hazmat_Letter.pdf PDF
801_Cover_Letter.pdf PDF
HERT_18-9002-Bldgs_2113,2114,2116_Part2_Part1.pdf PDF
HERT_13-9006_Demolish_Bldgs_2731-2783-85-94-99_Part3.pdf PDF
HERT_13-9006_Demolish_Bldgs_2731-2783-85-94-99_Part2_Part1.pdf PDF
HERT_18-9002-Bldgs_2113,2114,2116_Part1.pdf PDF
HERT_18-9002-Bldgs_2113,2114,2116_Part4_Part3.pdf PDF
HERT_18-9002-Bldgs_2113,2114,2116_Part2_Part2.pdf PDF
FA480019QA025.docx DOCX document
HERT_13-9006_Demolish_Bldgs_2731-2783-85-94-99_Part1.pdf PDF
HERT_13-9006_Demolish_Bldgs_2731-2783-85-94-99_Part2_Part2.pdf PDF
Show all 50

Fort Eustis Multi Building Demolition Project has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ASBESTOS INSPECTION REPORT

OF

BUILDING 2785

FORT EUSTIS, VIRGINIA

MCS JOB # 17-106S

Marine Chemist Service, Inc.

11850 Tug Boat Lane, Newport News, VA 23606-2527

Phone: (757) 873-0933 · Norfolk (757) 640-1122 Fax: (757) 873-1074 · Norfolk (757) 625-5696 www.MarineChemist.com

Asbestos Inspection Report of

Building 2785 Fort Eustis, Virginia on

September 6, 2017

Prepared for:

Kevin Panchision Guernsey Tingle Architects

4350 New Town Avenue, Suite 101 Williamsburg, Virginia 23188

MCS Job #17-106S

By

Patrick Studley, CIH Virginia Asbestos Inspector License 3303 003193

Marine Chemist Service, Inc.

11850 Tug Boat Lane

Newport News, Virginia 23606

(757) 873-0933

September 25, 2017 Date Inspector Signature

TABLE OF CONTENTS

SECTION 1 ------------------------------------------------------- Asbestos Inspection Report

SECTION 2 ------------------------------------------------------- Sample Summary Table

SECTION 3 ------------------------------------------------------- General Legend and Notes

SECTION 4 ------------------------------------------------------- ACM Sketches

SECTION 5 ------------------------------------------------------- Survey Sample Location Sketches

SECTION 6 ------------------------------------------------------- Report of Analysis

SECTION 7 ------------------------------------------------------- Inspection Information

SECTION 8 ------------------------------------------------------- Credentials

Guernsey Tingle - Asbestos Report MCS Job #17-106S - Fort Eustis Building 2785

SECTION 1

Asbestos Inspection Report

Guernsey Tingle - Asbestos Report

ASBESTOS INSPECTION OF BUILDING 2785

FORT EUSTIS, VIRGINIA

INTRODUCTION

Background and Purpose

There has been a growing public awareness of the link between the inhalation of asbestos fibers and various diseases such as asbestosis, mesothelioma, lung, and other cancers. As a result, the Asbestos Hazard Emergency Response Act (AHERA 40 CFR Part 763) for schools grades K through 12 was established by EPA.

The necessary components of an AHERA inspection require the accredited inspector to visually inspect and assess the condition of all known or assumed friable asbestos containing building materials (ACBM); to visually inspect non - friable ACBM and touch it to determine friability, and to identify homogeneous areas of friable materials.

EPA’s National Emission Standards for Hazardous Air Pollutants (NESHAPS) require thorough inspections for asbestos in structures before the renovation or demolition of those structures.

Virginia law requires that if the initial building permit was issued prior to January 1, 1985, an asbestos inspection must be performed prior to the local authorities issuing a building permit.

In order to comply with NESHAPS, buildings to be renovated or demolished must be thoroughly inspected for asbestos containing building materials. Marine Chemist Service, Inc.

follows the AHERA sampling protocol for interior surveys and the Virginia standard for roof surveys.

The purpose of this survey was to provide information for this property concerning the location and type of accessible and/or visible asbestos containing materials prior to renovation.

In compliance with Virginia Regulations, Marine Chemist Service Inc. performed an asbestos survey of Building 2785, located at Fort Eustis, Virginia on September 6, 2017.

Guernsey Tingle - Asbestos Report

General Information

Marine Chemist Service, Inc. was hired by Kevin Panchision of Guernsey Tingle to conduct an asbestos inspection and bulk sampling for suspect asbestos-containing building materials of Building 2785, located at Fort Eustis, Virginia.

Authorization

Authorization to perform this testing was provided by Kevin Panchision, Guernsey Tingle on August 10, 2017. The area was unoccupied at the time of the inspection.

Warranty

This visual inspection and laboratory report has been prepared in accordance with AHERA and Virginia requirements and current accepted professional practices. A minimum number of bulk asbestos samples were collected to determine the presence or absence of asbestos. This inspection has been performed to provide the client with information concerning the presence of accessible and/or exposed suspect asbestos containing building materials. In compliance with the owner’s wishes, destructive testing was not performed. This inspection documents conditions at the time of the inspection only. No other warranties are implied or expressed.

SURVEY METHODS

Inspection Methods

The asbestos survey was performed by Virginia licensed asbestos inspectors. An initial visual walk through inspection was performed to identify suspect asbestos containing materials and homogeneous areas.

All buildings that are part of this survey did not contain crawlspaces. All buildings are slab on grade construction.

Sampling Methods

The Virginia licensed asbestos inspector sampled the identified suspect materials within the homogeneous areas following the visual inspection. Sampling was not performed on any inaccessible materials and did not involve destructive testing of building components. Sample locations were selected randomly but also taken at less visible locations to minimize visible damage.

LABORATORY METHODS

Analysis Methods

The bulk sample was first visually observed and described. The sample was mounted onto a slide, covered with dispersion staining oil and a cover slip, and observed under a polarized light microscope (PLM). The asbestos and non-asbestos materials in the sample are identified by this method.

The PLM microscopist estimates the amounts of asbestos and non-asbestos components by determining visually the relative volume of each to the total volume of the sample.

Guernsey Tingle - Asbestos Report

ASBESTOS INSPECTION

Document Review and On-Site Survey

Blueprints were provided for the inspection. In addition, a sketch was made of the area to indicate sample/asbestos material locations.

Identification of Suspect Asbestos Containing Materials

A visual inspection was performed on the suspect asbestos containing material found in the survey areas. The suspect asbestos containing materials are as follows:

1. Shingles/ Tar Paper 2. Drywall/ Joint Compound

3. Carpet Adhesive 4. 12” Floor Tile and Mastic

5. 4” Base Cove and Adhesive 6. Window Caulk

7. Linoleum/ Backing 8. 2’ Ceiling Tile

9. 2’ Ceiling Tile Patch 10. Block Sealer

11. Door Caulk 12. Window Caulk

13. Window Glaze 14. Tank Insulation

15. Mudded Fittings 16. Pipe Sealer

17. Duct Sealer 18. Vibration Cloth

19. Silver Paint 19. Caulking

Bulk Sampling

Bulk sampling was performed on all suspect asbestos-containing materials found in the areas and the minimum number of samples were taken as required in the AHERA Standards.

Bulk samples were taken penetrating all layers of the material. The samples were at least one cubic centimeter and were placed in a sealed container at the time of collection. All precautions were taken to prevent exposure to those present in or around the facility during the collection of samples. All sampling locations were patched with an encapsulant after the sampling was complete.

Samples listed below are grouped into homogeneous areas. Homogeneous areas are areas, which are uniform by color, texture, construction/application date, and general appearance.

Some sample results in the % asbestos column may be displayed in this report with a slash between two numbers, (#/#). The first number represents the first material listed in the laboratory report under the material location/description and the second number represents the second material listed.

When N/A is placed in the friable category it means the sample tested negative - (0) or less than one percent - (<1%) for asbestos and the friable description does not apply.

Samples were analyzed utilizing Polarized Light Microscopy (PLM) with dispersion staining by a NVLAP accredited laboratory (Marine Chemist Service, Inc. NVLAP Lab Code 200628-0).

The results are in section 6.

Guernsey Tingle - Asbestos Report

SECTION 2

Sample Summary Table

Sample

# Lab Sample # Material Location and Description

Asbestos

Friable

Y/N

2785-1 0119711-001 Gazebo, Shingles/ Tar Paper 0/0/0 N/A

2785-2 0119711-002 Gazebo, Shingles/ Tar Paper 0/0/0 N/A

2785-3 0119711-003 Gazebo, Shingles/ Tar Paper 0/0/0 N/A

2785-4 0119711-004 IH Section, Drywall/ Joint Comopund 2/0/0 Y

2785-5 0119711-005 Safety Section, Drywall/ Joint Compound 0/0 N/A

2785-6 0119711-006 Safety Section, Drywall/ Joint Compound 0/0 N/A

2785-7 0119711-007 IH Section, Blue Carpet Adhesive 2 N

2785-8 0119711-008 IH Section, Blue Carpet Adhesive 0/2 N

2785-9 0119711-009 Safety Section, Blue Carpet Adhesive 2 N

2785-10 0119711-010 Hall, Blue 12" Floor Tile and Mastic 0/0 N/A

2785-11 0119711-011 Hall, Blue 12" Floor Tile and Mastic 0/0 N/A

2785-12 0119711-012 Hall, Blue 12" Floor Tile and Mastic 0/0 N/A

2785-13 0119711-013 IH Section, Gray 4" Base Cove and Adhesive 0/0/0 N/A

2785-14 0119711-014 Safety Section, Gray 4" Base Cove and Adhesive 0/0 N/A

2785-15 0119711-015 Hall, White Window Caulk 0/7 N

2785-16 0119711-016 IH Section, White Window Caulk 0/0 N/A

2785-17 0119711-017 Men's Room, Beige Linoleum/ Backing Linoleum 0/0 N/A

2785-18 0119711-018 Women's Room, Beige Linoleum/ Backing Linoleum 0/0 N/A

2785-19 0119711-019 Women's Room, Beige Linoleum/ Backing Linoleum 0/0 N/A

2785-20 0119711-020 IH Section, White 12" Floor Tile and Mastic 0/2 N

2785-21 0119711-021 IH Section, White 12" Floor Tile and Mastic 0/2 N

2785-22 0119711-022 IH Section, White 12" Floor Tile and Mastic 0/2 N

2785-23 0119711-023 IH Section, 2' Ceiling Tile - Wormed w/ holes 0 N/A

2785-24 0119711-024 Hall, 2' Ceiling tile - Wormed w/ holes 0 N/A

2785-25 0119711-025 Safety Section, 2' Ceiling Tile - Wormed w/ holes 0 N/A

2785-26 0119711-026 IH Section, Patch 2 Ceiling Tile - Small holes 0 N/A

2785-27 0119711-027 Hall, Block Sealer 0 N/A

2785-28 0119711-028 Hall, Block Sealer 0 N/A

2785-29 0119711-029 Exterior, Door Caulk 0 N/A

2785-30 0119711-030 Exterior, Door Caulk 0/3 N

2785-31 0119711-031 Exterior, Window Caulk 0 N/A

2785-32 0119711-032 Exterior, Window Caulk 0 N/A

Newport News, Virginia

Fort Eustis Building 2785

Guernsey Tingle - Asbestos Report

Sample

# Lab Sample # Material Location and Description

Asbestos

Friable

Y/N

2785-33 0119711-033 Exterior, Window Glaze 0 N/A

2785-34 0119711-034 Exterior, Window Glaze 0 N/A

2785-35 0119711-035 Mechanical Room, Tank Insulation 0/0/0 N/A

2785-36 0119711-036 Mechanical Room, Tank Insulation 0 N/A

2785-37 0119711-037 Mechanical Room, Tank Insulation 0/0/0 N/A

2785-38 0119711-038 Mechanical Room, Mudded Fittings 2/0/0 N

2785-39 0119711-039 Mechanical Room, Mudded Fittings 2/0/0 N

2785-40 0119711-040 Mechanical Room, Mudded Fittings 2/0/0 N

2785-41 0119711-041 Mechanical Room, Pipe Sealer 0/0 N/A

2785-42 0119711-042 Mechanical Room, Pipe Sealer 2 N

2785-43 0119711-043 Mechanical Room, Pipe Sealer 3/0 N

2785-44 0119711-044 Mechanical Room, Duct Sealer 10/0 N

2785-45 0119711-045 Mechanical Room, Duct Sealer 10/0 N

2785-46 0119711-046 Mechanical Room, Vibration Cloth 0 N/A

2785-47 0119711-047 Mechanical Room, Silver Paint 0 N/A

2785-48 0119711-048 Roof, White Caulking 20 N

2785-49 0119711-049 Roof, White Caulking 0 N/A

Guernsey Tingle - Asbestos Report

Comments

1. The following sampled materials tested positive for asbestos:

a. Joint Compound on Drywall

b. Blue Carpet Adhesive

c. White Window Caulk

d. Mastic under 12” White Floor Tile

e. Exterior Door Caulk

f. Mastic on Mudded Fittings

g. Pipe Sealer

h. Duct Sealer

i. White Roof Caulk

2. Standard practice for asbestos/nonasbestos material classification is if one sample of a material tests positive, all of the corresponding material throughout the building is assumed to be of the same composition.

3. Because the total content of asbestos in the Drywall/Joint Compound Wallboard System is less than 1%, this material does not have to be disposed of as asbestos waste. The Wallboard System must be removed by properly trained personnel using wet methods and prompt cleanup. It is recommended that this material be removed under negative pressure (with respect to the surrounding area) within a regulated area.

4. The Blue Carpet Adhesive is considered a Category I Nonfriable material (unless rendered friable) and may be removed in a Class II work area by properly trained and qualified personnel.

5. The White Window Caulk is considered a Category II Nonfriable material (unless

6. The Mastic under the 12” White Floor Tile is considered a Category I Nonfriable material (unless rendered friable) and may be removed in a Class II work area by properly trained and qualified personnel.

7. The Exterior Door Caulk is considered a Category II Nonfriable material (unless

8. The Mastic on Mudded Fittings and Pipe Sealer are Category II Nonfriable materials

(unless rendered friable) and may be removed in a Class II work area by properly trained and qualified personnel.

9. The Duct Sealer is considered a Category II Nonfriable material (unless rendered friable) and may be removed in a Class II work area by properly trained and qualified personnel.

10. The White Roof Caulk is considered a Category II Nonfriable material (unless

11. Asbestos might be found within walls, ceiling and or pipe chases during the renovation or demolition of the building. If any suspect materials are found they should treated as asbestos or tested for asbestos.

Approximate Quantities of Asbestos Materials

ASBESTOS CONTAINING MATERIALS QUANTITY CURRENT

CONDITION

Joint Compound on Drywall 13,000sq. ft. Intact Blue Carpet Adhesive 6,500 sq. ft. Intact White Window Caulk 1,400 linear ft. Intact Mastic under 12” White Floor Tile 325 sq. ft. Intact Exterior Door Caulk 100 linear ft. Intact Mastic on Mudded Fittings and Pipe Sealer 200 linear ft. Fair Duct Sealer 100 sq. ft. Fair White Roof Caulk 150 linear ft. Intact

Guernsey Tingle - Asbestos Report

SECTION 3

General Legend and Notes

Guernsey Tingle - Asbestos Report

GENERAL LEGEND

O - Sample number/location - non-asbestos

- Sample number/location - contains asbestos

- Door/Doorway

- Window

GENERAL NOTES

1. The EPA definition of a friable material is one that contains more than 1% asbestos by weight and can be crumbled, pulverized or reduced to a powder by hand pressure when dry, or which under normal use or maintenance emits or can be expected to emit asbestos fibers into the air.

2. All quantities are approximate.

3. Sketches are not to scale.

SECTION 4

Asbestos Containing Material Sketches

Hilliard

Skoropowski Peters

New Hire

Copy and Print Center

Surge

Winget

Surge

Conference Room

Storage Room

New Hire

Surge

Hall Latrines

Women'sMen'sMechanical

Mechanical Room

Industrial H ygiene

Asbestos Material Locations Building 2785

Fort Eustis, Virginia

Joint Compound on Drywall is present throughout the Building on all walls.

Mastic under Floor Tile Carpet Adhesive

(Entire Wing) Carpet Adhesive

(Entire Wing)

White Window Caulk is present around the Interior of all windows.

Exterior Door Caulk is present around the Exterior of all doors

Mastic on Mudded Fittings and Pipe Sealer

Duct Sealer

Guernsey Tingle - Asbestos Report MCS Job #17-106S - Fort Eustis Building 2785

Shannon Rectangle

Shannon Rectangle

Shannon Polygonal Line

Shannon Polygonal Line

Shannon Polygonal Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Polygonal Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Polygonal Line

Shannon Polygonal Line

Shannon Polygonal Line

Shannon Rectangle

Shannon Polygonal Line

Shannon Line

Shannon Polygonal Line

Shannon Polygonal Line

Shannon Polygonal Line

Shannon Polygonal Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Polygonal Line

Shannon Line

Shannon Line

Shannon Oval

Patrick Rectangle

Shannon Polygonal Line

Patrick Rectangle

Patrick Rectangle

Patrick Line

Patrick Line

Asbestos Material Locations Building 2785 Roof Fort Eustis, Virginia

White Roof Caulk

Guernsey Tingle - Asbestos Report MCS Job #17-106S - Fort Eustis Building 2785

Shannon Rectangle

Shannon Polygonal Line

Shannon Polygonal Line

Shannon Polygonal Line

Shannon Polygonal Line

Shannon Polygonal Line

Shannon Polygonal Line

Shannon Polygonal Line

Patrick Oval

Patrick Oval

Patrick Oval

Patrick Oval

Patrick Rectangle

Patrick Rectangle

Patrick Rectangle

Patrick Rectangle

Patrick Line

Patrick Line

Patrick Line

Patrick Line

SECTION 5

Survey Sample Location Sketches

Guernsey Tingle - Asbestos Report

Hilliard

Skoropowski Peters

New Hire

Copy and Print Center

Surge

Winget

Surge

Conference Room

Storage Room

New Hire

Surge

Hall Latrines

Women's Men'sMechanical

Mechanical Room

Industrial H ygiene

Asbestos Sample Locations Building 2785

Fort Eustis, Virginia

24 15

27 10

30 28

12 17

26 16

Gazebo

Guernsey Tingle - Asbestos Report MCS Job #17-106S - Fort Eustis Building 2785

Shannon Rectangle

Shannon Rectangle

Shannon Polygonal Line

Shannon Polygonal Line

Shannon Polygonal Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Polygonal Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Polygonal Line

Shannon Polygonal Line

Shannon Polygonal Line

Shannon Rectangle

Shannon Polygonal Line

Shannon Line

Shannon Polygonal Line

Shannon Polygonal Line

Shannon Polygonal Line

Shannon Polygonal Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Polygonal Line

Shannon Line

Shannon Line

Shannon Oval

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Line

Shannon Oval

Shannon Oval

Shannon Oval

Shannon Oval

Shannon Oval

Shannon Oval

Shannon Oval

Shannon Oval

Shannon Oval

Shannon Oval

Shannon Oval

Shannon Oval

Shannon Oval

Shannon Oval

Shannon Oval

Shannon Oval

Shannon Oval

Shannon Oval

Shannon Oval

Shannon Oval

Shannon Oval

Shannon Polygonal Line

Shannon Oval

Shannon Oval

Shannon Oval

Shannon Oval

Shannon Oval

Shannon Oval

Shannon Oval

Shannon Polygonal Line

Shannon Polygonal Line

Shannon Polygonal Line

Shannon Polygonal Line

Shannon Oval

Shannon Polygonal Line

Shannon Polygonal Line

Shannon Polygonal Line

Shannon Polygonal Line

Shannon Oval

Shannon Oval

Shannon Polygonal Line

Shannon Oval

Shannon Oval

Shannon Polygonal Line

Shannon Polygonal Line

Shannon Polygonal Line

Shannon Polygonal Line

Shannon Polygonal Line

Shannon Polygonal Line

Shannon Polygonal Line

SECTION 6

Reports of Analysis

Guernsey Tingle - Asbestos Report

SECTION 7

Inspection Information

Guernsey Tingle - Asbestos Report

Inspection Information

The survey contractor for the inspection of Building 2785, Fort Eustis, Virginia is:

11850 Tug Boat Lane Newport News, Virginia 23606 www.MarineChemist.com

The team leader responsible for quality control coordination of inspection and adherence to inspection protocol is:

Colleen Becker - CIH

11850 Tug Boat Lane

CBecker@MarineChemist.com

The AIHA and NVLAP Accredited laboratory selected to analyze the bulk samples for asbestos content by PLM, using the "Interim Method for the Determination of Asbestos in Bulk Insulation Samples” (Appendix A to Subpart F in 40 CFR Part 763) is:

Virginia Asbestos Analytical Laboratory License 3333 000004

11850 Tug Boat Lane

(757) 873-0933

The inspector who physically inspected the building and who has received EPA-Approved Training is:

Patrick Studley, CIH

Virginia Asbestos Inspector License 3303 003193 PStudley@MarineChemist.com

The Industrial Hygiene Inspector is employed by:

11850 Tug Boat Lane Newport News, Virginia 23606

(757) 873-0933

Guernsey Tingle - Asbestos Report

SECTION 8

Credentials

Guernsey Tingle - Asbestos Report

This Page May Be Removed Prior to Bid Submittal

BUILDING 2785

ASBESTOS CONTAINING MATERIALS QUANTITY COST

PER UNIT

REMOVAL

COST

Joint Compound on Drywall 13,000sq. ft. $ 8.00 $ 104,000.00 Blue Carpet Adhesive 6,500 sq. ft. $ 4.25 $ 27,625.00 White Window Caulk 1,400 linear ft. $ 5.50 $ 7,700.00 Mastic under 12” White Floor Tile 325 sq. ft. $ 4.25 $ 1,381.25 Exterior Door Caulk 100 linear ft. $ 5.50 $ 550.00 Mastic on Mudded Fittings and Pipe Sealer 200 linear ft. $ 3.50 $ 700.00 Duct Sealer 100 sq. ft. $ 2.75 $ 275.00 White Roof Caulk 150 linear ft. $ 5.50 $ 825.00

Total $ 143,056.25

*The abatement contractor may require a mobilization fee of approximately $ 1,600.00 in addition to removal costs. Prices may vary depending on volume of abatement that needs to be accomplished, difficulty of set up requirement, work hours, work days, accessibility of materials.

PM Sketch.pdf
Blank Page
Blank Page
Blank Page
Blank Page
Blank Page
Blank Page
PM Sketch Roof.pdf
Blank Page
Blank Page
Blank Page
Blank Page
Blank Page
Blank Page
AB Sample locations.pdf
Blank Page
Blank Page
Blank Page
Blank Page
Blank Page
Blank Page

File details come from the government source that posted it. Updated .