Attachment_1_-_SABER_Technical_Specifications.pdf
PDF 8 MB Posted
- Attached to
- SABER
- Solicitation number
- FA4661-17-R-0002
About this file
Attachment 1 - SABER Technical Specifications
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amendment_02.pdf | ||
| 9203_Plan - Kyle Smith Porch Design.dwg | DWG drawing | |
| 05700023.zip | ZIP file | |
| Dyess_9203_1.dwg | DWG drawing | |
| 6501617C.zip | ZIP file | |
| Dyess_9203_2.dwg | DWG drawing | |
| 09300080.zip | ZIP file | |
| 22_May_Q&A.docx | DOCX document | |
| Dyess_AFB_SABER_Questions_and_Answers.docx | DOCX document | |
| AMENDED_SABER_SOW.pdf | ||
| Attachment_5_-_SABER_Pricing_Schedule_AMENDED.xlsx | XLSX spreadsheet | |
| Amendment_01.pdf | ||
| Initial_Q&A.docx | DOCX document | |
| Attachment_3_-_Question_Submission_Form.doc | DOC document | |
| Attachment_8_-_Wage_Determination.pdf | ||
| Attachment_6_-_SABER_SOW_(Revised).pdf | ||
| Attachment_4_-_PPQ.pdf | ||
| 06._FA4661-17-R-0002_(20_Apr).pdf | ||
| Attachment_7_-_Site_Visit_Registration_Form.doc | DOC document | |
| Attachment_9_-_Past_Performance_Information_Document.docx | DOCX document | |
| 2014_Renovations_Bldg_9203.pdf | ||
| Attachment_5_-_SABER_Pricing_Schedule.xlsx | XLSX spreadsheet | |
| Attachment_2_-_Sample_Project_Bldg_9203.pdf |
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TECHNICAL SPECIFICATIONS
FOR
2016 Dyess AFB, Texas SABER Contract
FOR
7TH CIVIL ENGINEER SQUADRON
710 3RD STREET
DYESS AIR FORCE BASE, TEXAS 79607
Attachment 2
* * * FOR OFFICIAL USE ONLY * * *
TABLE OF CONTENTS
TOC
DIVISION 00 & 01 - GENERAL REQUIREMENTS
00 01 02 SPECIAL CONDITIONS
00 01 03 UTILITIES
00 01 04 ENVIRONMENTAL
00 01 05 FLIGHT LINE
01 78 00 AS-BUILT DRAWINGS
01 78 23 OPERATION & MAINTENANCE DATA
DIVISION 02 - EXISTING CONDITIONS
02 41 00 DEMOLITION
02 61 13 EXCAVATION & HANDLING OF CONTAMINATED MATERIAL
02 81 00 TRANSPORTATION & DISPOSAL of HAZARDOUS MATERIALS 02 82 16 ENGINEERING CONTROL of ASBESTOS CONTAINING MATERIALS 02 82 33 REMOVAL/CONTROL & DISPOSAL of PAINT WITH LEAD
DIVISION 03 – CONCRETE
03 15 13 EXPANSION/CONTRACTION JOINTS & WATERSTOPS
03 20 01 CONCRETE REINFORCEMENT
03 30 00 CAST-IN-PLACE CONCRETE
DIVISION 04 – MASONRY
04 20 00 MASONRY
04 21 13 NONBEARING MASONRY VENEER/STEEL STUD WALLS
DIVISION 05 – METALS
05 05 23 WELDING, STRUCTURAL
05 12 00 STRUCTURAL STEEL
05 21 19 OPEN WEB STEEL JOIST FRAMING
05 30 00 STEEL DECKS
05 40 00 COLD-FORMED METAL FRAMING
05 50 00 METAL: MISCELLANEOUS & FABRICATIONS
DIVISION 06 – WOOD, PLASTICS, & COMPOSITES
06 10 00 ROUGH CARPENTRY
06 18 00 GLUE-LAMINATED CONSTRUCTION
06 20 00 FINISH CARPENTRY
06 41 16 LAMINATE CLAD ARCHITECTURAL CASEWORK
06 61 16 WOOD CASEWORK
DIVISION 07 – THERMAL & MOISTURE PROTECTION
07 11 13 BITUMINOUS DAMPPROOFING
07 13 53 ELASTOMERIC SHEET WATERPROOFING
07 19 00 WATER REPELLENTS
07 21 13 BOARD & BLOCK INSULATION
07 21 16 MINERAL FIBER BLANKET INSULATION
07 22 00 ROOF & DECK INSULATION
07 24 00 EXTERIOR INSULATION & FINISH SYSTEMS (EIFS)
07 31 13 FIBERGLASS ASPHALT SHINGLES
07 41 13 STANDARD METAL ROOF SYSTEM
07 42 13 METAL WALL PANELS
07 42 63 FABRICATED WALL PANEL ASSEMBLIES
07 52 00 SBS-MODIFIED BITUMINOUS SHEET ROOFING
07 54 19 POLYVINYL-CHLORIDE (PVC) ROOFING
07 60 00 FLASHING SHEET METAL
07 61 14 STANDING SEAM METAL ROOF SYSTEM
07 71 00 ROOF SPECIALTIES
07 71 90 ROOF SCUTTLE
07 84 00 FIRE-STOPPING
07 92 00 SEALANTS
DIVISION 08 – OPENINGS
08 11 13 STEEL DOORS & FRAMES
08 11 16 ALUMINUM DOORS & FRAMES
08 14 00 WOOD DOORS
08 33 13 METAL ROLLING COUNTER DOORS
08 33 23 OVERHEAD COILING DOORS
08 34 19 ROLLING SERVICE & FIRE DOORS
08 34 53 FIRE-INSULATED & RECORD-VAULT DOORS
08 34 54 SECURITY DOORS & FRAMES
08 34 59 SECURITY VAULT DOORS
08 34 73 SOUND CONTROL DOOR ASSEMBLIES
08 36 13 SECTIONAL OVERHEAD DOORS
08 36 19 VERTICAL LIFT DOORS
08 39 54 BLAST RESISTANT DOORS
08 44 00 GLAZED CURTAIN WALL
08 51 13 ALUMINUM WINDOWS
08 62 00 SKYLIGHTS
08 71 00 DOOR HARDWARE
08 81 00 GLAZING
08 91 00 METAL WALL & DOOR LOUVERS
DIVISION 09 – FINISHES
09 22 00 METAL SUPPORT ASSEMBLIES
09 29 00 GYPSUM BOARD
09 30 00 CERAMIC, QUARRY, & PAVER TILE
09 51 00 ACOUSTICAL CEILINGS
09 65 00 RESILIENT FLOORING
09 65 33 CONDUCTIVE VINYL FLOORING
09 68 00 CARPET
09 69 13 RIGID GRID ACCESS FLOORING
09 83 13 ACOUSTICAL WALL PANELS
09 90 00 PAINTS & COATINGS
DIVISION 10 – SPECIALTIES
10 10 00 VISUAL COMMUNICATIONS
10 14 01 EXTERIOR SIGNAGE
10 14 02 INTERIOR SIGNAGE
10 21 13 TOILET COMPARTMENTS
10 22 26 FOLDING PANEL PARTITIONS
10 26 13 WALL & CORNER GUARDS
10 28 13 TOILET ACCESSORIES
10 44 16 FIRE EXTINGUISHERS
DIVISION 12 – FURNISHINGS
12 21 00 WINDOW BLINDS
DIVISION 13 – SPECIAL CONSTRUCTION
13 34 19 PRE-ENGINEERED METAL BUILDINGS
DIVISION 21 – FIRE SUPPRESSION
21 13 13.10 WET PIPE SPRINKLER SYSTEM, FIRE PROTECTION
21 13 17.10 DRY PIPE SPRINKLER SYSTEM, FIRE PROTECTION
DIVISION 22 – PLUMBING
22 00 00 PLUMBING, GENERAL PURPOSE
DIVISION 23 – HVAC
23 00 00 AIR SUPPLY, DISTRIBUTION, VENTILATION, & EXHAUST SYSTEMS
23 05 93 TESTING, ADJUSTING, & BALANCING OF HVAC SYSTEMS
23 07 00 THERMAL INSULATION for MECHANICAL SYSTEMS
23 08 00 COMMISSIONING of HVAC SYSTEMS 23 09 23 BACNET DIRECT DIGITAL CONTROL SYSTEM for HVAC
23 11 23 GAS PIPING SYSTEMS
23 23 00 REFRIGERANT PIPING
23 25 00 CHEMICAL TREATMENT of WATER for MECHANICAL SYSTEMS
23 52 00 HEATING BOILERS
23 54 16 HEATING SYSTEM, GAS-FIRED HEATERS
23 81 23 COMPUTER ROOM AIR CONDITIONING UNITS (CRACU)
23 82 01 WARM AIR HEATING SYSTEMS
23 82 02 UNITARY HEATING & COOLING EQUIPMENT
DIVISION 26 – ELECTRICAL
26 00 00 BASIC ELECTRICAL MATERIALS & METHODS
26 05 13 MEDIUM-VOLTAGE CABLES
26 05 19 LOW VOLTAGE ELECTRICAL POWER CONDUCTORS & CABLES
26 05 73 OVERCURRENT PROTECTIVE DEVICES
26 12 19.10 THREE-PHASE PAD-MOUNTED TRANSFORMERS
26 12 19.20 SINGLE-PHASE PAD MOUNTED TRANSFORMERS
26 20 00 INTERIOR DISTRIBUTION SYSTEM
26 23 00 SWITCHBOARDS & SWITCHGEAR
26 24 16 PANELBOARDS
26 27 13 ELECTRIC METERS
26 29 23 VARIABLE FREQUENCY DRIVE SYSTEMS UNDER 600 VOLTS
26 32 14 DIESEL-GENERATOR SET, STATIONARY 15-300 KW
26 36 00 AUTOMATIC TRANSFER SWITCH & BY-PASS/ISOLATION SWITCH
26 41 01 LIGHTNING PROTECTION SYSTEM
26 42 14 CATHODIC PROTECTION SYSTEM (SACRIFICIAL ANODE)
26 51 00 INTERIOR LIGHTING
26 56 00 EXTERIOR LIGHTING
26 60 13 LOW VOLTAGE MOTORS (600V OR LESS)
DIVISION 27 – COMMUNICATIONS
27 05 28 CABLE TRAYS for COMMUNICATIONS SYSTEMS
DIVISION 28 – ELECTRONIC SAFETY & SECURITY
28 05 26 GROUNDING & BONDING for ELECTRONIC SAFETY & SECURITY
28 31 76 INTERIOR FIRE ALARM & MASS NOTIFICATION SYSTEM
DIVISION 31 – EARTH WORK
31 00 00 EARTHWORK
31 05 19 GEOTEXTILE
31 10 00 CLEARING FOR CIVIL WORKS
31 11 00 CLEARING & GRUBBING
31 23 00 EXCAVATION & FILL
31 32 11 SOIL SURFACE EROSION CONTROL
DIVISION 32 – EXTERIOR IMPROVEMENTS
32 16 13 CONCRETE SIDEWALKS & CURBS / GUTTERS
32 17 23 PAVEMENT MARKINGS
32 31 13 CHAIN LINK FENCES & GATES
32 31 14 HIGH-SECURITY CHAIN LINK FENCES & GATES
32 31 19 METAL SLAT FENCE (Kynar) 32 31 19 METAL SLAT FENCE (Powdercoat)
32 92 19 SEEDING
DIVISION 33 – UTILITIES
33 11 00 WATER DISTRIBUTION
33 30 00 SANITARY SEWERS
33 70 02 ELECTRICAL DISTRIBUTION SYSTEM, UNDERGROUND
Section 00 01 02 Dyess AFB, Texas
SPECIAL CONDITIONS 2016 SABER
Special Conditions – Section 00 01 02 - page 1 of 6
PART 1 – GENERAL
1. SCOPE: The work covered by this project consists of the Contractor furnishing all layout, survey, plant, labor, supervision, quality control, materials, equipment, machines, tools, appliances, services, supplies, and incidentals and of performing all operations in connection with the design and building of the specific task identified on the specific delivery order, “seed project”, task order or construction contract requirement at Dyess AFB, Texas, complete and in strict accordance with the plans and specifications."
2. WORKING CONDITIONS: Contractor shall carefully consider the following when contemplating any specific task identified by the government reflecting any special or unusual conditions which may affect the Contractor's work such as:
- phasing requirements
- work area availability
- joint occupancy
- scheduling
- down time
- aircraft traffic or other interruptions (See Section 00 01 05 – Flight Line)
- required notice requirements
- requirements for Contractor employees to enter secured work areas
- traffic control
- temporary heating/cooling
- required certificates prior to award
- required work plans
- any other special conditions
Above all, insure this item is properly coordinated and discussed in detail with the user/occupant.
WORKING CONDITIONS: (APPLICABLE TO MILITARY FAMILY HOUSING AREA ONLY)
Field offices, storage facilities or staging areas are not permitted in the Military Family Housing area.
Contractor operated/owned vehicles, equipment, tools, toilet facilities as well as building materials, waste, rubbish or construction debris shall not remain on site overnight in the Military Family Housing area. All Contractor operated/owned vehicles, equipment, tools, etc., shall be stored as prescribed in paragraph STORAGE FACILITIES. Applicable traffic control signage where required by the contract may remain overnight in the Military Family Housing area.
3. WORK SCHEDULE: Working hours for the Contractor will normally be between the hours of 7:30 a.m. and 4:30 p.m. excluding Saturdays, Sundays, and Federal holidays. If the Contractor desires to work during periods other than above, additional government inspection forces may be required. The Contractor must make their request to the Contracting Officer five (5) calendar days in advance of their intention to work during other periods to allow assignment of additional inspection forces. If such force is reasonably available, the Contracting Officer may authorize the Contractor to perform work during periods other than normal duty hours/days.
3.1 DOWN TIME: Down time shall be defined as delays in excess of one hour at a given period, caused by the Government through no fault of the Contractor.
a. MEASUREMENT:
(1) Down time will be measured by the unit time-of-the-clock hour which will include all
Special Conditions – Section 00 01 02 - page 2 of 6
Contractor and sub-Contractor (at any tier) work forces scheduled for, or working during the hour.
(2) No delays less than one hour in duration at any given period will be measured nor considered for down time, nor will delays of less than one hour be cumulative over several time periods.
(3) Down time will not be measured/considered for delays before or after contract work schedule hours as defined in the contract General Provisions.
(4) No time after 10 minutes from the time that Contractor is notified that he can resume work after a stoppage will be considered down time.
Contractor shall comply with all security requirements under paragraph 13 of this specification section to qualify for down time compensation.
b. PAYMENT: Payment for down time will be made at the contract unit price for down time as shown on the bid schedule in accordance with the Contact Clause entitled Payments Under Fixed Price Construction Contracts.
4. SAFETY AND HEALTH:
4.1 All Contractor operations shall be conducted and performed in accordance with Department of Labor, OSHA requirements found in 29 CFR 1910 and 29 CFR 1926, project identified national standards, military manuals, instructions, pamphlets, and standards and handbooks.
4.2 All companies who conduct business within the state of Texas must, in accordance with Texas Workman Compensation laws (Texas House Bill 62), have an approved company safety policy and an Accident Prevention Plan. The plan, approved by the Texas Workman Compensation Commission (TWCC), shall be submitted For Information Only (FIO) in accordance with paragraph SUBMITTAL REQUIREMENTS. In addition to meeting the TWCC requirements; the plan must also include the requirements of COE Safety Manual, latest edition.
4.3 All holes/pits/trenches/manway openings, etc, that are to be left open shall be surrounded with a 48 inch high mesh fence with highly visible orange plastic coating. The fence shall be securely anchored with tension wires and posts as required to prevent sagging and located a minimum of 3 feet from the opening so as to prevent an individual, should they fall across the fencing, from falling into the opening.
Holes shall also be covered, when not being worked in, with three quarter inch plywood or a metal grating that will prevent small children from entering the hole. If the hole/pit is too large to cover, then a ladder of sufficient length shall remain in the hole/pit for egress.
4.4 Radiation Permits and Authorizations: Contractors contemplating the use of devices containing radioactive materials (i.e., soil moisture/density probes) or non-ionizing radiation producing equipment (radio frequency radiation emitters or lasers) while performing work on this contract must obtain written authorization/permit from the Dyess AFB Radiation Safety Officer (RSO), 7 AMDS/SGPB. To obtain the required authorization permit, an application to bring a radioactive device on Dyess AFB must be forwarded to 7 AMDS/SGPB, 697 Louisiana Loop, Dyess AFB, TX 79607-1367 (this is mailing address, physical address is 880 Third St.) or (325)696-2325 / 3289, at least 45 days prior to the anticipated use.
Without the proper authorization, Contractors will not be allowed to bring these devices on base. Also, Contractor shall provide Bioenvironmental Engineering (7 AMDS/SGPB) a copy of contractor’s radioactive materials permit and training certificates, if radioactive material will be brought onto Dyess
AFB.
4.5 Confined Space Entry: All operations involving entry into confined spaces shall meet the requirements of OSHA 29 CFR 1910.146, AFOSH Std 91-25, and specifically the following:
Special Conditions – Section 00 01 02 - page 3 of 6
a. All entry supervisors, attendees, and confined space entrants shall have been properly trained in the safety hazards, proper use of Personal Protective Equipment (PPE), entry procedures, and self-rescue.
Records of this training must be readily available.
b. Entry supervisors shall maintain a Master Entry Plan (MEP) consisting of:
(1) Descriptions of confined spaces to be entered including location, classification, and acceptable entry conditions
(2) Designation of authorized entry supervisors, entrants, and attendees
(3) Identification of the types of tasks to be performed in the confined space, including duration
(4) Procedures for entry, and emergency rescue
(5) Identification of Personal Protective Equipment (PPE), communication equipment, rescue equipment, and monitoring equipment; conditions under which they will be used; and verification of condition of equipment
(6) Designation of frequency and type of atmospheric monitoring
(7) Designation of controls required (e.g., lockout/tagout, ventilation, etc.)
(8) Procedures for communication during confined space operations
c. All confined spaces shall be tested by a qualified person using a properly calibrated monitor for percent oxygen, lower explosive limit (LEL), and toxicity each time before entry and periodically during operations that have the potential to alter atmospheric conditions. Supervisors shall contact 7 BW/SEG when these or any other entry conditions are not consistent with the MEP.
4.6 Additionally, other special considerations which may apply such as speed limits in MFH, vehicles with catalytic converters operating within 50' of aircraft, work being performed in explosives clear zones, equipment disposition in the Munitions Storage Area (MSA) during and after work hours, etc. For most conditions FAR 52.236-13 Accident Prevention, which Contracting will include by reference, will be sufficient. A paragraph on "Airfield Safety Precautions," DFARS 252.236-7005, should automatically be included by reference by Contracting in the General Provisions of applicable airfield construction contracts. Verify the FAR references to avoid duplication. Resolve with Contracting if in doubt.
5. STREET CLOSINGS: (Use only when required)
5.1 One lane of traffic shall be maintained at all times unless otherwise approved in writing by the Contracting Officer.
5.2 Contractor shall provide 14-day advance written notice to Contracting Officer prior to any street closures to insure that Fire Department and Emergency personnel are notified.
5.3. The final street repair shall be completed within 14 days after the start of any street demolition for utility crossings or other purposes. Any part of the street returned to service prior to final repair shall be maintained smooth with hot-mix cold-lay surface course.
5.4 Special note to Designers: Utilities are covered under Section 00 01 03. Also, IAW 05 May 97 HQ ACC/CE policy; trenching and excavation of pavements will be curtailed to the maximum extent possible. The recommended method for utility installations crossing streets, sidewalks, curbs, or gutters is trenchless boring or jacking. Excavations must be kept to an absolute minimum and used in those rare cases; such as repair of existing utility lines and solid obstructions, which preclude the use of boring technology. A separate special specification section is normally required for jacking and boring.
6. DISPOSITION OF WASTE, EXCESS, SCRAP, AND SALVAGE MATERIALS: The title to all waste, excess, scrap, and salvage materials generated as a direct result of this contract is vested in the
Special Conditions – Section 00 01 02 - page 4 of 6
Contractor - unless specifically excepted below. Further (unless listed below in exceptions), these materials shall be disposed of off the Base by the Contractor in accordance with all applicable Federal, State, and Local Regulations. Following is a list of materials (Exceptions) that will be generated as a result of this contract and shall be turned-in to the Government at a location at Dyess AFB designated by the Contracting Officer:
Exceptions: Government will identify salvage in SOW/SOO for each project.
7. STORAGE AREA (I.E. TEMPORARY FIELD OFFICE, STAGING AREAS, TOOL/JOB SHACKS,
AND OTHER CONSTRUCTION FACILITIES): There are no Government furnished covered or secure storage areas. Limited on-base, off-site storage will be permitted on a space available basis. The location on Dyess AFB of the Contractor’s temporary field office, storage, and other construction buildings required temporarily in the performance of the work, shall require written approval of the Contracting Officer. Plans showing temporary field office, storage, and other construction buildings shall be submitted for approval (GA) of the Contracting Officer. Utilities at the storage area may or may not be available for Contractor use. The Government implies no responsibility for lost or stolen materials, equipment or tools, the security of which lies solely with the Contractor. Contractor shall keep their storage areas clean, neat and orderly and will keep grass mowed to a maximum height of 4 inches.
Temporary fencing used by the Contractor to delineate constructor sites shall be securely anchored with tension wires and posts as required to prevent sagging and an unsightly appearance. Fencing shall be maintained by the Contractor in this manner throughout the life of the contract. Due to high winds in West Texas, Contractor shall take every precaution to preclude trash from blowing off site.
7.1 CONSTRUCTION AREA & CONTRACTOR LIMITS OF CONSTRUCTION: Contractor shall keep their construction areas clean, neat and orderly and will keep grass mowed to a maximum height of 4 inches.
8. TOILET FACILITIES:
8.1 Use of existing toilet facilities if available will identified in SOO/SOW. Contractor personnel will ensure facility cleanliness is maintained at all times.
8.2 If not identified in the SOO/SOW, there are no toilet facilities available for Contractor use.
Contractor shall provide his own portable/temporary toilet facilities.
9. CLEAN-UP: The Contractor shall at all times keep the construction site and storage area(s) free from accumulation of waste, rubbish, or construction debris. All loose or lightweight materials shall be secured to prevent blowing or scattering. The burning of trash or construction debris is strictly prohibited on Dyess AFB. Prior to final inspection, the Contractor shall remove all construction debris, tools, equipment, and materials not the property of the Government. Upon completion of the work, the Contractor shall leave the work site and storage area(s) in a clean, neat and workmanlike condition satisfactory to the Contracting Officer.
9.1 Additional requirements may be specified in the SOO/SOW such as special noise limitations, dust protection or existing equipment protection, etc.
10. INSPECTIONS:
A. Above Ceiling Inspection: The Contractor shall advise the Contracting Officer of the Contractor's desired above ceiling inspection date seven (7) calendar days in advance of that desired date to permit proper coordination.
B. Final Inspection: The Contractor shall advise the Contracting Officer of the Contractor's desired final inspection date seven (7) calendar days in advance of that desired date to permit proper
Special Conditions – Section 00 01 02 - page 5 of 6 coordination. The date selected shall provide adequate time for Contractor performed corrections of final inspection deficiencies within the contract performance time. The Contracting Officer will be the final authority for determining whether or not the Contractor's performance is sufficiently advanced to warrant a final inspection.
11. TESTING: Costs of all tests, unless specifically indicated as being performed by the Government, will be at the Contractor's expense. It is the responsibility of the Contractor to schedule all tests and to notify the Contracting Officer or his representative in a timely manner prior to any required testing. All test results shall be submitted to the Contracting Officer on AF Form 3000, Material Approval Submittal.
12. AS-BUILT DRAWINGS, INSTRUCTION MANUALS, AND TRAINING:
12.1 As-Built Drawings: Refer to Section 01 78 00. The Contractor shall maintain two sets of project drawings for "as-built" notations and marking. The Contractor shall update these plans to indicate "as-built" construction and shall submit them to the Contracting Officer prior to final inspection under the cover of an AF Form 3000. Updated notations and markings shall be neat, clear, and legible in all respects.
12.2 INSTRUCTION MANUALS (O&M Data): Refer to Section 01 78 23. Required instruction manual(s) shall be provided in three ring binder(s) with tabs and an index/table of contents. Provide permanent label on front and side with project title, project number, facility number, street address, Contractor/Subcontractor name, address, phone number(s), and manual title/contents description. Include all wiring diagrams and parts lists. Manuals shall be submitted to the Contracting Office for approval prior to Final Inspection.
12.3 TRAINING REQUIREMENTS: Provide training for government operating and service personnel in the proper operation of contractor furnished equipment. Schedule training time(s) with Contracting Officer to permit maximum participation by government personnel. Each instruction or training period shall be video taped by the Contractor and files will be submitted to the Government in WMV, MPEG, or MP-4 format on a CD/DVD. The taping shall include the entire session(s). The original CD/DVD video(s) shall be labeled and turned over to the Contracting Officer shall be of a quality to enable clear and understandable playbacks of the recorded events.
13. SECURITY REQUIREMENTS:
Dyess AFB security may be viewed as being one of three broad levels, the level in effect being dependent on the location or AREA of Dyess AFB in question.
a. The lowest level of security exists in GENERAL ACCESS AREAS. These AREAS are all of Dyess AFB outside of the "USAF Controlled" and "USAF Restricted" AREAS.
b. USAF Controlled Access AREAS are the mid-level security AREAS. Presence within the CONTROLLED ACCESS AREA is by authorization; however, the movement of authorized personnel in and out of these AREAS is generally not impeded. Contractor personnel are given access to these
AREAS.
c. The third and highest level of security on Dyess AFB is that within the USAF RESTRICTED AREAS. These AREAS are further subdivided to be known as Protection Level 1, 2 or 3 AREAS.
13.1 Referencing the above, the work on this contract will be identified in the SOO/SOW.
13.2 Requests for changes to the work schedule for work in USAF restricted areas, must be submitted a minimum of 7 calendar days in advance for approval and coordination of Dyess AFB
Special Conditions – Section 00 01 02 - page 6 of 6
Security Forces.
13.3 Dyess Air Force Base is a closed base. All personnel entering must have specific permission of the installation commander for entry. This permission is granted when a Contractor employee is issued an identification card. Information necessary to obtain identification cards will be provided by the Contracting Officer at the pre-performance conference. The Contractor shall be responsible to ensure that all of its employees obtain, and keep on their person at all times while working on the base, a USAF identification card. Upon completion of the work or termination of an employee, the Contractor shall be responsible for turn in of identification cards no longer needed to the Contracting Officer or to the Pass and Registration Office of the Security Forces. Failure to turn in badges will result in last payment of payroll to be withheld and revocation of any future badges issued by Pass and Registration Office to the employee and the contractor.
13.4 APPLICABLE TO RESTRICTED OR FLIGHTLINE CONTROLLED AREAS ONLY:
Contractor shall be required to enclose their contract work area, storage area and employee parking area with 3/8" yellow nylon rope. This rope fence will be supported by fastening it to the top of temporary posts or structures. The posts/structures will be 3 feet (+10%) high. The post/structures spacing and rope tautness will be such that the rope will be no closer than 2 1/2 feet above the walking surface. This fence may be omitted where existing structures bound the contract work area. The intent of this requirement is that all personnel (Contractors, Air Force, and visitors) will know the authorized boundary of each Contractor's area and thereby minimize unauthorized movement, and to help promote safety.
14. IDENTIFICATION OF CONTRACTOR VEHICLES: Contractor vehicles must be marked on each side with company name with either permanent or semi-permanent / magnetic signage.
15. WARRANTIES: Any warranties given to the Contractor or sub-Contractor at any tier from a manufacturer of equipment or other items which are provided under this contract shall be transferred to the Government upon final acceptance. Contractor shall submit in writing a single listing with all applicable warranties attached.
16. SUBMITTALS:
16.1 Required Submittals: All submittals required by the Contract Documents shall be submitted for approval to the Contracting Officer. Use a completed AF Form 3000 as a transmittal document. Where a submittal cannot be provided within the required submission date, Contractor shall submit in writing a letter stating the reasons why and furnishing a new projected submission date. All Material Submittals (Form AF 3000) and all submittal data shall be submitted electronically. All pdf’s shall be created from original electronic documents, no scans allowed due to file size, unless otherwise approved.
16.2 Variations/Deviations/Departures from the Contract Documents: Contractor proposed variations, deviations or departures from the contract requirements shall be noted/marked in red on each copy of the submittal data and shall be provided with a letter attachment to the AF Form 3000 summarizing the proposed variation, deviation, or departure. Variations, deviations, or departures shall contain sufficient information to permit complete evaluation. Additional sheets may be used to fully explain why a variation, deviation, or departure is requested. The Government reserves the right to disapprove or rescind inadvertent approval of submittals containing unnoted/unmarked/not-clearly-defined variations, deviations or departures.
17. INSURANCE REQUIREMENTS
17.1 For the purpose of this FAR 52.228-5 the following minimum limits are provided:
Special Conditions – Section 00 01 02 - page 7 of 6
17.2 Workmen’s Compensation and Employers Liability Insurance as required by law except if this contract is to be performed in a State which does not require or permit private insurance, then compliance with the statutory or administrative requirements in any such State will be satisfactory. The required Workmen’s Compensation insurance shall extend to cover employer’s liability for accidental bodily injury or death and for occupational disease with a minimum liability limit of $100,000.
17.3 General Liability Insurance. Bodily injury liability insurance, in the minimum limits of $500,000 per occurrence shall be required on the comprehensive form of policy.
17.4 Automobile Liability Insurance. This insurance shall be required on the comprehensive form of policy and shall provide bodily injury liability and property damage liability covering the operation of all automobiles used in connection with the performance of the contract. At least the minimum limits of $200,000 per person and $500,000 per occurrence for bodily injury and $20,000 per occurrence for property damage shall be required.
18. INVESTIGATION OF DAMAGE OR INJURY
18.1 The United States Government will have the right to conduct an investigation, or participate in the contractor’s investigation, of any damage or injury to United States Government property, equipment or personnel.
19. CONTRACTOR RESPONSIBILITY
19.1 Contractors operating on base shall be responsible for briefing and ensuring their employees adhere to the traffic rules and regulations. The foreman, job supervisor, and other personnel providing workman leadership will, when possible, ensure the workers comply with these rules and regulations. Speed limit on base is 30 MPH unless otherwise posted. The speed limit in base housing areas is 20 MPH and the speed limit in parking lots is 5 MPH. The school zone speed limit is 5 MPH. Individuals are to obey all entry procedures. If instructions are given by the Security Forces personnel on the entry points (gates), they will be complied with immediately. Security Forces utilize speed detection devices and citations will be issued to violators. Personnel who park on grass or seeded areas will be cited.
20. CONSTRUCTION EQUIPMENT
20.1 Equipment and vehicles to be used on base shall be safe and in good operating condition.
The Contracting Officer, or authorized representative, reserves the right to inspect any on-base equipment and reject such equipment if he/she considers it unsafe, in poor operating condition, or inappropriate for work. Contractor must notify the Contracting Officer of any contractor equipment that is broken down on Dyess AFB roads. Every effort should be made to move broken down equipment to the nearest parking lot before leaving it.
21. GOVERNMENT LIABILITY
Special Conditions – Section 00 01 02 - page 8 of 6
21.1 The Government shall not be liable for any loss or damage to the contractor’s property, including stock, or for expense incidental to such loss or damage.
22. TELEPHONE COMMUNICATION SECURITY MONITORING
22.1 All communications with DOD organizations are subject to communications security (COMSEC) review. Contractor personnel will be aware telephone communications networks are continually subject to intercept by unfriendly intelligence organizations. The DOD has authorized that military departments conduct COMSEC monitoring and recording of telephone calls originating from, or terminating at, DOD organizations. Therefore, civilian contractor personnel are advised any time they place a call to, or receive a call from, a USAF organization, they are subject to COMSEC procedures. The contractor will assume the responsibility for ensuring wide and frequent dissemination of the above information to all employees.
**** END OF SECTION ****
Section 00 01 03 Dyess AFB, Texas
UTILITIES 2016 SABER
Utilities – Section 00 01 03 - page 1 of 4
1. SCOPE: This section covers identification, interruption and use of utilities.
2. IDENTIFICATION: THE GOVERNMENT DOES NOT KNOW THE LOCATION OF UTILITIES
IN THE WORK AREA. Accordingly, the Contractor shall be SOLELY RESPONSIBLE for locating and marking the exact location of all existing utilities within the contract work area prior to any excavating, trenching, backfilling or disturbance. The Contractor is SOLELY RESPONSIBLE for any and all damage to existing utilities in the contract work area. Upon request by the Contractor, the Government shall furnish all available information in its possession concerning utilities in the contract work area. However, the accuracy of the information provided by the Government is not guaranteed and is only intended to provide some measure of assistance to the Contractor. The Contractor shall call 7 CS/SCOIT at 696-8065 a minimum of five (5) calendar days in advance to have underground communications cable routes marked. Base Civil Engineering does not have nor shall it provide record drawings of Bell Telephone cable plant. In the event the Contractor identifies utilities in the contract work area which interfere with the newly proposed construction, the Contracting Officer shall be immediately notified and the Government shall take necessary corrective action at no cost to the Contractor. The Contractor shall furnish to the Contracting Officer as-built drawings clearly identifying the exact location of all utilities identified in the work area prior to project final inspection.
2.1 Contractor must initiate a Work Clearance Request AF Form 103 (digging permit) from 7 CES/ CEPM a minimum of seven (7) calendar days prior to the start of any construction work. Excavation is not authorized without issuance of a completed and approved AF Form 103. After initial issue, it is the Contractor's responsibility to keep the Work Clearance Request coordinated and up-to-date/current through the remainder of the contract.
2.2 Any removal/relocation/reconnection of any communication device shall be coordinated in advance with 7 CS/SCOIT at 696-8065. Any removal/relocation/reconnection of any Cable TV device shall be also be coordinated in advance with 7 CS/SCOIT (ask for the NCOIC of Cable TV) at 696-2400.
Communications and Cable TV devices to remain shall be protected as required when work proximity dictates.
2.3 Any removal/relocation/reconnection of any fire protection device or intrusion detection systems shall be coordinated in advance with 7 CES/CEOFE at 696-5184. Any removal/relocation/reconnection of any security system should be coordinated with 7 SFS/S5C at 696-8523.
2.4 The locating and marking devices utilized by the contractor for existing utilities or proposed work shall be 2” wooden stakes with multicolored whiskers 4” to 6” in length.
2.5 Exposed Existing Utilities: When existing utilities to remain are exposed, the Contractor shall contact the Contracting Officer and 7 CES Geobase Shop to survey any exposed utility line or feature below the surface. In addition, when new utility lines are installed or constructed, the Contractor shall contact the Contracting Officer and 7 CES Geobase Shop to survey all utility features below the surface. The Contracting Officer and 7 CES Geobase Shop must be contacted 5 days prior to the utility lines being back-filled. 7 CES Geobase Shop may be contacted at 325-696- 5630. The Contractor will be responsible for any additional costs for exposing new utility lines that have not been surveyed by 7 CES Geobase Shop.
3. INTERRUPTIONS:
3.1 Planned Utility Outages: The Contractor shall coordinate all requests for utility outages with the Contracting Officer in writing fourteen (14) calendar days prior to date of requested outage. Water, gas, steam, sewer and electrical outages shall be held to a maximum duration of 2 hours unless otherwise approved in writing. See Contractor Request for Utility Outage included in this Section.
Utilities – Section 00 01 03 - page 2 of 4
3.2 Unplanned Utility Outages (Accidental Disruption of Utilities): In the event of accidental disruption of any utility, the Contractor shall immediately notify the Contracting officer of the unplanned outage.
The Contractor shall immediately take every reasonable step to repair the damage in a manner acceptable to the Government and will restore the utility to full use as soon as practicable. If the Contractor so desires, and the Government agrees, the Government may complete necessary repairs to the damaged utility and withhold from payments due to the Contractor the necessary amount to defray all costs associated with the repair of the utility.
4. USE: All reasonable quantities of existing utilities will be made available to the Contractor without charge. Any temporary connections or lines required shall be installed, maintained, and removed at the Contractor's expense. Any damage associated with the use of these utilities shall be repaired and/or replaced in a manner satisfactory to the Contracting Officer at Contractor's expense. See Contractor Request for Use of Dyess AFB Fire Hydrants included in this Section.
Utilities – Section 00 01 03 - page 3 of 4
The following information must be prepared and forwarded, on AF Form 3000, Material Approval Submittal, to the CO for approval and coordination with Civil Engineering.
Request For Utility Outage
From: __________________________________________________________________
Contract No:__________________Description and Location of Contract: __________
Date of Outage Requested:___________Type of Outage:_________________________
Location Affected by Outage:
Description of Work to be performed and Other Utilities Affected:
Requested Civil Engineer Support:
Date:_______________ Time:________________________
Type of Support:
Electrical X-5184_______ Water X-4481__________________
Access X-4155_________ Road Closure X-4155____________
Alarms X-5195_________ Fire Dept Standby X-4930________
Duration of Outage: Start:_____ Completed:____________________
Signature:
Contractor Representative: Date:
Utilities – Section 00 01 03 - page 4 of 4
The following information must be prepared and forwarded, on AF Form 3000, Material Approval Submittal, to the Contracting Officer for approval and coordination with Civil Engineering’s Fire Department and Utilities prior to use of Base fire hydrants.
Contractor Request for Use of Dyess AFB Fire Hydrants.
Project Title ___________________________________________________________________
1. The ____________________________ Company requests the use of fire hydrant number _______for the purpose of ______________________________________ used in the performance of the contract to ___________________________. Period of hydrant use will be ________________ to _____________.
I understand approval is contingent on all of the following:
a. The company providing a suitable connection with a Class III Back Flow Preventer (reduced pressure principle device) and screw type globe valve to be attached to the hydrant. The connection will be 2 1/2" National Standard fire thread. The backflow device and valve shall be installed prior to hydrant use & properly supported to prevent damage to fire hydrant threads.
b. Call the Water Shop for certification of your backflow device PRIOR TO INSTALLATION at 325-696-1807. Non-compliant devices will be removed without notice.
c. Backflow preventers shall be installed with the vent facing down & at least 12" clearance below the unit.
d. Leaving the connection in place during approval period.
e. Insuring the hydrant is fully opened and left in that position during approval period, except in periods of freezing weather. If hydrant is closed, it must be RECERTIFIED prior to reopening.
f. Insuring an approved fire hydrant wrench is used to open/close the hydrant.
g. Insuring all servicing from the hydrant is done at the top of the vehicle or tank. No bottom servicing will be permitted.
h. Using no quick opening valves causing excess water hammer in the main.
i. Discontinuing hydrant use if there is any hydrant malfunction or leakage from underground and reporting same to the Fire Department, 696-2486.
2. I understand and agree that __________________________Company assumes full responsibility for any damage to the hydrant, water mains, adjacent grounds, vegetation, buildings, or streets resulting from hydrant use.
(Signature) (Date)
(Print Name) (Print Title)
**** END OF SECTION ****
Section 00 01 04 Dyess AFB, Texas
ENVIRONMENTAL 2016 SABER
Environmental – Section 00 01 04 - page 1 of 18
1. APPLICABLE ENVIRONMENTAL REGULATIONS, LAWS, AND PUBLICATIONS: In accordance with (IAW) Executive Orders (EO) 13101, 13123, 13134, and 13148, federal, state, and local environmental protection laws, Dyess Air Force Base (DAFB) is committed to the principals of “Leadership in Environmental Management” and “Greening the Federal Government.” In addition, DAFB implements EO 13045, 13229, and 13296, to ensure protection from environmental health and safety risks. The specifications and standards contained in this section are to ensure that DAFB meets the mandates as established by statute and EOs, as well as Environmental Protection Agency (EPA), Department of Transportation (DOT), Occupational, Safety and Health Agency (OSHA), and Department of Energy (DOE) policy and guidance.
1.1. ENVIRONMENTAL PROTECTION STANDARDS: The following list serves as the basis for standards of environmental protection for work accomplished on DAFB:
· The Resource Conservation and Recovery Act authorized Comprehensive Procurement Guidelines (CPG),
· The National Technology Transfer and Advancement Act/OMB Circular A-119,
· DOE's Federal Energy Management Program Product Efficiency Recommendations,
· EPA's Waste Minimization Priority Chemicals,
· EPA's Indoor Environments Program Recommendations, and
· EPA's Construction Industry Compliance Assistance Center Recommendations.
1.3. ENVIRONMENTAL GOALS:
1.3.1. General:
1.3.1.1. Resource Management: Promote stewardship of the earth's resources. The earth's resources include: perpetual resources, renewable resources, and non-renewable resources.
Preserve or renew biodiversity and ecosystems.
· Maximize use of bio-based and recycled content materials.
· Maintain or improve water quality and promote water stewardship.
· Employ job-site recycling and salvage procedures.
· Employ DfE methodologies.
1.3.1.2. Toxicity/IEQ: Promote good indoor environmental quality (IEQ). Aspects of IEQ include:
light quality, acoustic quality, and air quality.
· Utilize a precautionary approach.
· Maximize use of non-toxic, non-hazardous, healthy, and safe building materials.
1.3.1.3. Performance: Promote efficiencies in operational performance. Aspects of operational performance include: durability, maintainability, energy efficiency, and water efficiency.
1.4. CONTRACTOR’S ENVIRONMENTAL MANAGER: The Contractor shall designate an onsite party responsible for overseeing the environmental goals for the project and implementing procedures for environmental protection.
1.4.1. Qualifications: Minimum 5 years construction experience on projects of similar size and scope;
minimum 2 years experience with environmental procedures similar to those of this project; familiarity with Environmental Management Systems (EMSs) such as ISO 14001; and familiarity with environmental regulations applicable to construction operations.
1.4.2. Responsibilities: The Contractor’s environmental manager shall ensure:
Environmental – Section 00 01 04 - page 2 of 18
· Compliance with applicable federal, state, and local environmental regulations, including maintaining required documentation.
· Implementation of Contractor’s environmental protection plans prepared IAW EPA EMS or ISO 14000 standards.
· Training for Contractor personnel IAW their position requirements, and shall include at a minimum, an overview of environmental issues related to the building industry and overview of environmental issues and regulations related to the project.
1.5 CONFORMANCE with ENVIRONMENTAL MANAGEMENT SYSTEMS:
The Contractor shall perform work under this contract consistent with the relevant policy and objectives identified in the agency, organizational, or facility environmental management system (EMS) applicable for your contract. The Contractor shall perform work in a manner that conforms to all appropriate Environmental Management Programs and Operational Controls identified by the agency, organizational, or facility EMS, and provide monitoring and measurement information as necessary for the organization to address environmental performance relative to the environmental, energy, and transportation management goals. In the event an environmental nonconformance or noncompliance associated with the contracted services is identified, the contractor shall take corrective and/or preventative actions. In the case of a noncompliance, the Contractor shall respond and take corrective action immediately. In the case of a nonconformance, the Contractor shall respond and take corrective action based on the time schedule established by the EMS Site Coordinator. In addition, the Contractor shall ensure that their employees are aware of the roles and responsibilities identified by the environmental management system and how these requirements affect their work performed under this contract.
All Contractor employees must complete Air Force provided initial EMS awareness-level training. The COR needs to ensure the contractor and their employees complete the training prior to work start and maintain a list of completion in the contract folder for accountability and inspection. The following steps need to be completed by the contractor in order to logon and complete the required training:
To access and register to the ESOH Training Network:
Go to www.esohtn.com
Click on the to enter, then
Find the Registration box on the bottom right side of the screen.
Type into the Registration Password box esohtn
Click on Create an Account, and Follow the instructions on each screen to complete each step of the registration process all blocks with an “*” must be filled.
Step 1. First and Last Name and email address
Step 2 Account information User Id and password
Step 3 User Type: Select “Construction Contractor “or “Non-Construction” Next
Environmental – Section 00 01 04 - page 3 of 18
Step 4 Organization information, Select “Dyess AFB”, for your company name if listed, if not listed
Select “Company not Listed”. Select contractor number if applicable—Next.
Step 5 Under Job Functions select “Environmental Requirements for Contractors (Mandatory for all Installation Contractors)” Next
Step 6 Select “I agree”
Step 7 Select “Go To Training”
Step 8 Select “Go to my Training Modules”
Step 9 Select “Go to training” and complete training, complete test and print certificate
When training is complete, forward certificate to the Contractor.
PART 2 – RESOURCE PROTECTION
2. PROTECTION OF RESOURCES: Construction, renovation or demolition activities are not exempt from air emission, storm water, hazardous waste, and other environmental compliance, environmental protection or pollution prevention rules and regulations. Contractor shall investigate, comprehend, and comply with all environmental rules and regulations applicable to his chosen method of accomplishment of the work under this contract.
2.1. PROTECTION OF LAND RESOURCES: The Contractor shall confine his construction activities to areas defined by the plans or specifications. Except in areas to be cleared, do not remove, cut, deface, injure or destroy trees or shrubs without the CO’s approval. Do not fasten or attach ropes, cables, or guys to existing nearby trees for anchorage unless authorized by the CO. Where such use of ropes, cables, or guys is authorized, the Contractor shall be responsible for any resultant damage.
2.1.1. Restoration or Replacement of Landscape Damage: Any trees or other landscape feature scarred or damaged by the Contractor’s equipment or operations shall be restored as nearly as possible to its original condition at the Contractor's expense. The CO will decide what method of restoration shall be used, and whether damaged trees shall be treated or removed and disposed of under requirements for clearing and grubbing. If damaged trees are to be removed, they are to be replaced with equivalent, undamaged trees and landscaping features at the Contractor’s expense.
2.1.2 Topsoil and other Construction Fill Material from Off Base: Contractor must comply with the Federal Noxious Weed Act, as amended, 7 U.S.C. 2801-2814; 7CFR360: the Plant Protection Act (7 U.S.C. 7701 et seq.); 7 U.S.C. 7701-7772 and 7781-7786; 7 CFR 2.22, 2.80, and 371.3; and Executive Order 13112, Invasive Species. The Contractor shall not introduce any invasive or noxious weed identified on the latest Federal Noxious Weed List (Federal Noxious Weed Act of 1974), the Texas Administrative Code (TAC) Quarantines and noxious plants, Chapter 19 (24 May 2006). State of Texas;
the DAFB Integrated Natural Resources Management Plan, Chapter 7.12, Invasive Species Management.
2.1.3. Post-Construction Cleanup or Obliteration: The Contractor shall obliterate all evidence of temporary construction facilities such as haul roads, work areas, structures, foundations of temporary structures, stockpiles of excess materials, or any other vestiges of construction. It is anticipated that excavation, filling, and plowing of roadways will be required to restore the area to near natural conditions which will permit the growth of vegetation thereon. The disturbed areas shall be graded and filled as required, and topsoil shall be spread to a depth of approximately three inches over the entire area and the entire area seeded with at least two pounds (pure live seed) of common Bermuda per 1,000 square feet
Environmental – Section 00 01 04 - page 4 of 18 and then watered as required until a lush hardy growth is established to the satisfaction of the CO.
Restoration to original contours is required unless otherwise directed by the CO.
2.2. PROTECTION OF THE STRATOSPHERIC OZONE: The Contractor shall comply with Title 40 of the Code of Federal Regulations, Part 82 (40 CFR Part 82). To the maximum extent practicable, the Contractor shall utilize safe alternatives and products made with, or containing, safe alternatives to Class I or II ozone depleting substances (ODS) identified in 42 U.S.C. 7671K. A Class I ODS is defined in section 602 (a) of the Clean Air Act (CAA) and includes the following chemicals:
CFC-11 CFC-12 CFC-13 CFC-111 CFC-112
CFC-113 CFC-114 CFC-115 CFC-211 CFC-212
CFC-213 CFC-214 CFC-215 CFC-216 CFC-217
halon-1211 halon-1301 halon-2402 carbon tetrachloride methyl chloroform
2.3. PROTECTION OF HISTORICAL AND ARCHAEOLOGICAL RESOURCES: All known historical, archaeological, and cultural resources, if any, within the Contractor’s work area will be designated on the contract drawings. The Contractor shall take precautions during the contract to preserve all resources as they existed at the time of contract award and comply with the National Historic Preservation Act (NHPA), 36 CFR 60-61 and 800-812; and Native American Graves Protection and Repatriation Act (NAGPRA), 43 CFR 10.
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .