This is a Checklist and Report for Inspection of Hydraulic Elevators based on ASME A17.2 standards. The document is a periodic inspection report completed on August 7, 2024, for a passenger hydraulic elevator located at 7215 Goddard Drive, Malmstrom, Montana 59402 (Building 1441). The elevator has a rated load capacity of 750 pounds, operates at 15 feet per minute, and was inspected by Robert Helms under Montana Building Services, LLC certification.

The checklist systematically evaluates six major inspection areas: Inside of Car (20 items covering doors, controls, lighting, emergency systems, and safety features), Machine Room (42 items addressing hydraulic power units, relief valves, control systems, electrical components, and maintenance records), Top of Car (27 items covering emergency exits, hoistway construction, suspension means, and safety devices), Outside Hoistway (12 items examining doors, locking devices, and enclosure integrity), Pit (16 items assessing buffers, piping, safety systems, and overspeed valves), and Firefighters' Service (9 items corresponding to various ASME code editions from 1973 through 2013). Each item is marked as OK (meets requirements), NG (does not meet—with comment numbers), or NA (not applicable). The inspection was conducted under ASME A17.1 code edition standards, with the report noting that seismic inspection and testing requirements apply for areas in seismic risk zones 2 or greater.

View the file

Other files

File Type Posted
H-01.pdf PDF
G-01.pdf PDF
E-01.pdf PDF
B-01.pdf PDF
Questions and Answers .xlsx XLSX spreadsheet
I-01.pdf PDF
82110.pdf PDF
F-01.pdf PDF
D-01.pdf PDF
500.pdf PDF
O-01.pdf PDF
L-01.pdf PDF
K-01.pdf PDF
J-01.pdf PDF
C-01.pdf PDF
N-01.pdf PDF
M-01.pdf PDF
A-01.pdf PDF
1012.pdf PDF
Solicitation Amendment - FA462626Q00250003.pdf PDF
Solicitation Amendment - FA462626Q00250002.pdf PDF
Solicitation Amendment - FA462626Q00250001.pdf PDF
Installation Perimeter Access Control.pdf PDF
Solicitation - FA462626Q0025.pdf PDF
PWS_atch1_Missile Field Map.pdf PDF
QASP_Post_RedactedNoPersonnelInfo.pdf PDF
PWS.pdf PDF
Bid.xlsx XLSX spreadsheet
Show all 28

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Checklist and Report for Inspection of Hydraulic Elevators

GENERAL NOTES:

(a) See ASME A17.2 for detailed Code requirements. Numbering is tied to the numbering on A17.2 sections.

(b) OK = Meets requirements NG = Insert number to identify comment on back of this checklist NA = Not Applicable

Routine Inspection and Test Periodic Inspection and Test Acceptance Inspection and Test

Address: _______________________________________________________________________________________________________________________________________________________

ID No.: ___________________________________________________________________________ Code Edition: ________________________________________________________________

Passenger Rated Load: _________________________ lb or kg Inspected by: ______________________________________________________________

Freight Class: __________________________________________ Signature: ____________________________________________________________________

Speed: ________________________ fpm or m/s Certifi cate No: _______________ Certifying Organization: ___________________________________________________

OK NG NA

1 INSIDE OF CAR

1.1 Door reopening device

1.2 Stop switches

1.3 Operating control device

1.4 Sills and car fl oor

1.5 Car lighting and receptacles

1.6 Car emergency signal

1.7 Car door or gate

1.8 Door closing force

1.9 Power closing of doors or gates

1.10 Power opening of doors or gates

1.11 Car vision panels and glass car doors

1.12 Car enclosure

1.13 Emergency exit

1.14 Ventilation

1.15 Signs and operating device symbols

1.16 Rated load, platform area and data plate

1.17 Standby power operation

1.18 Restricted opening of car or hoistway doors

1.19 Car ride

1.20 Earthquake inspection and tests

(seismic risk zone 2 or greater)

2 MACHINE ROOM

2.1 Access to machine space

2.2 Headroom

2.3 Lighting and receptacles

2.4 Machine space

2.5 Housekeeping

2.6 Ventilation

2.7 Fire extinguisher

2 MACHINE ROOM (continued) OK NG NA

2 MACHINE ROOM (continued)

2.8 Pipes, wiring and ducts

2.9 Guarding of exposed auxiliary equipment

2.10 Numbering of elevators, machines, controllers and disconnect switches

2.11 Disconnecting means and control

2.12 Controller wiring, fuses, grounding, etc.

2.13 Governor, overspeed switch and seal

2.14 Code data plate

2.30 Hydraulic power unit

2.31 Relief valves

2.32 Control valve

2.33 Tanks

2.36 Hydraulic

2.37 Pressure switch

2.38 Roped water hydraulic elevators

2.39 Low oil

2.40 MCP and Maintenance Records

2.41 Static Control

2.42 Earthquake inspection and tests

(seismic risk zone 2 or greater)

3 TOP OF CAR

3.1 Top of car stop switch

3.2 Car top light and outlet

3.3 Top of car operating device

3.4 Top of car clearance, refuge space

and standard railing

3.5 Normal terminal stopping device

3.6 Final and emergency terminal stopping devices

3.7 Car leveling and anticreep devices

(continued on page 2)

(from Code Data Plate)

OK NG NA

3 TOP OF CAR (continued)

3.8 Top emergency exit

3.9 Floor and emergency identifi cation numbering

3.10 Hoistway construction

3.11 Hoistway smoke control

3.12 Pipes, wiring and ducts

3.13 Windows, projections, recesses and setbacks

3.14 Hoistway clearances

3.15 Multiple hoistways

3.16 Traveling cables and junction boxes

3.17 Door and gate equipment

3.18 Car frame and stiles

3.19 Guide rails, fastenings and equipment

3.20 Governor rope

3.21 Governor releasing carrier

3.22 Wire rope fastening and hitch plate

3.23 Suspension means

3.27 Crosshead data plate and rope data tags

3.28 Counterweight and counterweight buffer

3.29 Counterweight safeties

3.30 Speed test

3.31 Slack Rope Test - Roped Hydro

3.32 Traveling Sheave - Roped Hydro

3.34 Earthquake inspection and tests

(seismic risk zone 2 or greater)

4 OUTSIDE HOISTWAY

4.1 Car platform guard

4.2 Hoistway doors

4.3 Vision panels

4.4 Hoistway door locking devices

4.5 Access to hoistway

4.6 Power closing of hoistway doors

4.7 Sequence operation

4.8 Hoistway enclosure

4.9 Elevator parking device

4.10 Emergency doors in blind hoistways

4.12 Standby power selection switch

2 MACHINE ROOM (continued) OK NG NA

5 PIT

5.1 Pit access, lighting, stop switch and condition

5.2 Bottom clearance, runby and minimum

refuge space

5.4 Normal terminal stopping devices

5.5 Traveling cables

5.6 Governor rope tension device

5.7 Car frame and platform

5.8 Car and counterweight safeties

and guiding members

5.11 Plunger and cylinder

5.12 Car buffer (Springs)

5.13 Guiding members

5.14 Supply piping

5.15 Overspeed valve

5.16 Earthquake inspection and tests

(seismic risk zone 2 or greater)

6 FIREFIGHTERS’ SERVICE (FEO)

6.1 A17.1b-1973 through A17.1b-1980

6.2 A17.1-1981 through A17.1b-1983

6.3 A17.1-1984 through A17.1a-1988 and A17.3

6.4 A17.1b-1989 through A17.1b-2000

6.5 A17.1-2000 and B44-00

6.6 A17.1-2004 and B44-04

6.7 A17.1-2007 and B44-07

6.8 A17.1-2010 and B44-10

6.9 A17.1-2013 and B44-13

Comments: ______________________________________________________________

Reprinted from ASME A17.2-2014, by permission of The American Society of Mechanical Engineers. All rights reserved.

Address: 7215 Goddard Dr., Malmstrom, MT 59402
ID No: Building 1441
Rated Load: 750
Routine: Off
Periodic: Off
Acceptance: Off
Inspected By: Robert Helms / August 07, 2024
Code Edition: ASME A17.1
Certificate No: N/A
Speed: 15
Class: N/A
Passenger: Off
Freight: Off
4:
1 OK: Off
1 NG: Off
1 NA: Off
12 OK: Off
12 NG: Off
12 NA: Off
10 OK: Off
10 NG: Off
10 NA: Off
9 OK: Off
9 NG: Off
9 NA: Off
8 OK: Off
8 NG: Off
8 NA: Off
7 OK: Off
7 NG: Off
7 NA: Off
6 OK: Off
6 NG: Off
6 NA: Off
5 OK: Off
5 NG: Off
5 NA: Off
4 OK: Off
4 NG: Off
4 NA: Off
3 OK: Off
3 NG: Off
3 NA: Off
2 OK: Off
2 NG: Off
2 NA: Off
6:
1 OK: Off
1 NG: Off
1 NA: Off
2 OK: Off
2 NG: Off
2 NA: Off
3 OK: Off
3 NG: Off
3 NA: Off
4 OK: Off
4 NG: Off
4 NA: Off
5 OK: Off
5 NG: Off
5 NA: Off
6 OK: Off
6 NG: Off
6 NA: Off
7 OK: Off
7 NG: Off
7 NA: Off
8 OK: Off
8 NG: Off
8 NA: Off
9 OK: Off
9 NG: Off
9 NA: Off
3:
8 OK: Off
8 NG: Off
8 NA: Off
9 OK: Off
9 NG: Off
9 NA: Off
10 OK: Off
10 NG: Off
10 NA: Off
11 OK: Off
11 NG: Off
11 NA: Off
12 OK: Off
12 NG: Off
12 NA: Off
13 OK: Off
13 NG: Off
13 NA: Off
14 NG: Off
14 NA: Off
14 OK: Off
15 OK: Off
15 NG: Off
15 NA: Off
16 OK: Off
16 NG: Off
16 NA: Off
17 OK: Off
17 NG: Off
17 NA: Off
18 OK: Off
18 NG: Off
18 NA: Off
19 OK: Off
19 NG: Off
19 NA: Off
20 NG: Off
20 OK: Off
21 OK: Off
21 NG: Off
21 NA: Off
22 OK: Off
22 NG: Off
22 NA: Off
23 OK: Off
23 NG: Off
23 NA: Off
27 OK: Off
27 NG: Off
27 NA: Off
28 OK: Off
28 NG: Off
28 NA: Off
29 OK: Off
29 NG: Off
20 NA: Off
29 NA: Off
30 OK: Off
30 NG: Off
30 NA: Off
31 OK: Off
31 NG: Off
31 NA: Off
32 OK: Off
32 NG: Off
32 NA: Off
34 OK: Off
34 NG: Off
34 NA: Off
1 OK: Off
1 NG: Off
1 NA: Off
2 OK: Off
2 NG: Off
2 NA: Off
3 OK: Off
3 NG: Off
3 NA: Off
4 OK: Off
4 NG: Off
4 NA: Off
5 OK: Off
5 NG: Off
5 NA: Off
6 OK: Off
6 NG: Off
6 NA: Off
7 OK: Off
7 NG: Off
7 NA: Off
5:
1 OK: Off
1 NG: Off
1 NA: Off
2 OK: Off
2 NG: Off
2 NA: Off
4 OK: Off
4 NG: Off
4 NA: Off
5 OK: Off
5 NG: On
5 NA: Off
6 OK: Off
6 NG: Off
6 NA: Off
7 OK: Off
7 NG: Off
7 NA: Off
8 OK: Off
8 NG: Off
8 NA: Off
11 OK: Off
11 NG: On
11 NA: Off
12 OK: Off
12 NG: Off
12 NA: Off
13 OK: Off
13 NG: On
13 NA: Off
14 OK: Off
14 NG: Off
14 NA: Off
15 OK: Off
15 NG: Off
15 NA: Off
16 OK: Off
16 NG: Off
16 NA: Off
2:
8 OK: Off
8 NG: Off
8 NA: Off
9 OK: Off
9 NG: Off
9 NA: Off
10 OK: Off
10 NG: Off
10 NA: Off
11 OK: Off
11 NG: Off
11 NA: Off
12 OK: On
12 NG: Off
12 NA: Off
13 OK: Off
13 NG: Off
13 NA: Off
14 OK: Off
14 NG: Off
14 NA: Off
30 OK: Off
30 NG: On
30 NA: Off
31 OK: Off
31 NG: Off
31 NA: Off
32 OK: Off
32 NG: Off
32 NA: Off
33 OK: Off
33 NG: Off
33 NA: Off
36 OK: Off
36 NG: Off
36 NA: Off
37 OK: Off
37 NG: Off
37 NA: Off
38 OK: Off
38 NG: Off
38 NA: Off
39 OK: Off
39 NG: Off
39 NA: Off
40 OK: Off
40 NG: On
40 NA: Off
41 OK: Off
41 NG: Off
41 NA: On
42 NG: Off
42 NA: Off
42 OK: Off
1 OK: Off
1 NG: Off
1 NA: Off
2 OK: Off
2 NG: Off
2 NA: Off
3 NA: Off
3 OK: Off
3 NG: Off
4 OK: Off
4 NG: Off
4 NA: Off
5 OK: Off
5 NG: Off
5 NA: Off
6 OK: Off
6 NG: Off
6 NA: Off
7 OK: Off
7 NG: Off
7 NA: Off
1:
1 OK: Off
1 NG: Off
1 NA: Off
2 OK: Off
2 NG: Off
2 NA: Off
3 OK: On
3 NG: Off
3 NA: Off
4 OK: Off
4 NG: Off
4 NA: Off
5 OK: On
5 NG: Off
5 NA: Off
6 OK: On
6 NG: Off
6 NA: Off
7 OK: Off
7 NG: Off
7 NA: Off
8 OK: Off
8 NG: Off
8 NA: Off
9 OK: Off
9 NG: Off
9 NA: Off
10 OK: Off
10 NG: Off
10 NA: Off
11 OK: Off
11 NG: Off
11 NA: Off
12 OK: Off
12 NG: Off
12 NA: Off
13 OK: Off
13 NG: Off
13 NA: Off
14 OK: Off
14 NG: Off
14 NA: Off
15 OK: Off
15 NG: Off
15 NA: Off
16 OK: Off
16 NG: Off
16 NA: Off
17 OK: Off
17 NG: Off
17 NA: Off
18 OK: Off
18 NG: Off
18 NA: Off
19 OK: Off
19 NG: Off
19 NA: Off
20 OK: Off
20 NG: Off
20 NA: Off
Certifying Organization: Montana Building Services, LLC
Sig:
Comments: See Attached

File details come from the government source that posted it. Updated .