1012.pdf

PDF 398 KB Posted

Attached to
Vertical Transportation Equipment Repair
Solicitation number
FA462626Q0025
Issued by

About this file

This is a Checklist and Report for Inspection of Electric Elevators based on ASME A17.2 code requirements. The document serves as a standardized inspection tool for evaluating electric elevator systems across three inspection types: Routine Inspection and Test, Periodic Inspection and Test, and Acceptance Inspection and Test.

The checklist is organized into six major sections covering all critical elevator components and systems. Section 1 addresses the inside of the car, including door reopening devices, stop switches, operating controls, lighting, emergency signals, doors, ventilation, and emergency exits. Section 2 covers the machine room, encompassing access, headroom, lighting, controllers, governors, overspeed switches, brakes, traction drives, sheaves, rope fastenings, terminal stopping devices, safeties, and maintenance records. Section 3 focuses on the top of car components including stop switches, operating devices, terminal stopping devices, car leveling, hoistway construction, traveling cables, door equipment, guide rails, governor rope, suspension means, counterweight equipment, and speed testing. Section 4 addresses the outside hoistway, including car platform guards, hoistway doors, vision panels, locking devices, and power closing mechanisms. Section 5 covers the pit area with access, lighting, clearances, terminal stopping devices, traveling cables, buffers, safeties, and guiding members. Section 6 documents Firefighters' Service (FEO) requirements across various ASME code editions from 1973 through 2013. The completed example shows a routine inspection at MAFB Building 1012 in Malmstrom, Montana, for a 2,500-pound rated passenger elevator operating at 150 fpm, inspected by Robert Helms on August 7, 2024, by Montana Building Services, LLC.

View the file

Other files

File Type Posted
I-01.pdf PDF
82110.pdf PDF
F-01.pdf PDF
D-01.pdf PDF
500.pdf PDF
O-01.pdf PDF
H-01.pdf PDF
G-01.pdf PDF
E-01.pdf PDF
B-01.pdf PDF
Questions and Answers .xlsx XLSX spreadsheet
1441.pdf PDF
M-01.pdf PDF
A-01.pdf PDF
L-01.pdf PDF
K-01.pdf PDF
J-01.pdf PDF
C-01.pdf PDF
N-01.pdf PDF
Solicitation Amendment - FA462626Q00250003.pdf PDF
Solicitation Amendment - FA462626Q00250002.pdf PDF
Solicitation Amendment - FA462626Q00250001.pdf PDF
Solicitation - FA462626Q0025.pdf PDF
PWS_atch1_Missile Field Map.pdf PDF
QASP_Post_RedactedNoPersonnelInfo.pdf PDF
Installation Perimeter Access Control.pdf PDF
PWS.pdf PDF
Bid.xlsx XLSX spreadsheet
Show all 28

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Checklist and Report for Inspection of Electric Elevators

GENERAL NOTES:

(a) See ASME A17.2 for detailed Code requirements. Numbering is tied to the numbering on A17.2 sections.

(b) OK = Meets requirements NG = Insert number to identify comment on back of this checklist NA = Not Applicable

Routine Inspection and Test Periodic Inspection and Test Acceptance Inspection and Test

Address: _______________________________________________________________________________________________________________________________________________________

ID No.: ___________________________________________________________________________ Code Edition: ________________________________________________________________

Passenger Rated Load: _________________________ lb or kg Inspected by: ______________________________________________________________

Freight Class: __________________________________________ Signature: ____________________________________________________________________

Speed: ________________________ fpm or m/s Certifi cate No: _______________ Certifying Organization: ___________________________________________________

OK NG NA

1 INSIDE OF CAR

1.1 Door reopening device

1.2 Stop switches

1.3 Operating control devices

1.4 Sills and car fl oor

1.5 Car lighting and receptacles

1.6 Car emergency signal

1.7 Car door or gate

1.8 Door closing force

1.9 Power closing of doors or gates

1.10 Power opening of doors or gates

1.11 Car vision panels and glass car doors

1.12 Car enclosure

1.13 Emergency exit

1.14 Ventilation

1.15 Signs and operating device symbols

1.16 Rated load, platform area and data plate

1.17 Standby power operation

1.18 Restricted opening of car or hoistway doors

1.19 Car ride

1.20 Earthquake inspection and tests

(seismic risk zone 2 or greater)

2 MACHINE ROOM

2.1 Access to machine space

2.2 Headroom

2.3 Lighting and receptacles

2.4 Machine space

2.5 Housekeeping

2.6 Ventilation

2.7 Fire extinguisher

2 MACHINE ROOM (continued) OK NG NA

2 MACHINE ROOM (continued)

2.8 Pipes, wiring and ducts

2.9 Guarding of exposed auxiliary equipment

2.10 Numbering of elevators, machines, controllers and disconnect switches

2.11 Disconnecting means and control

2.12 Controller wiring, fuses, grounding, etc.

2.13 Governor, overspeed switch and seal

2.14 Code data plate

2.15 Static control

2.16 Overhead beam and fastenings

2.17 Drive machine brake

2.18 Traction drive machines

2.19 Gears, bearings and fl exible couplings

2.20 Winding drum machine and slack cable rope

device, stop motion switch and rope fastening

2.21 Belt or chain drive machine

2.22 Motor generator

2.23 Absorption of regenerated power

2.24 AC drives from a DC source

2.25 Traction sheaves

2.26 Secondary and defl ector sheaves

2.27 Rope fastenings

2.28 Terminal stopping devices

2.29 Car and counterweight safeties

2.38 Roped water hydraulic elevators

2.40 MCP and Maintenance Records

2.41 Static Control

2.42 Earthquake inspection and tests

(seismic risk zone 2 or greater)

(continued on page 2)

(from Code Data Plate)

OK NG NA

3 TOP OF CAR

3.1 Top of car stop switch

3.2 Car top light and outlet

3.3 Top of car operating device

3.4 Top of car clearance, refuge space

and standard railing

3.5 Normal terminal stopping device

3.6 Final and emergency terminal stopping devices

3.7 Car leveling and anticreep devices

3.8 Top emergency exit

3.9 Floor and emergency identifi cation numbering

3.10 Hoistway construction

3.11 Hoistway smoke control

3.12 Pipes, wiring and ducts

3.13 Windows, projections, recesses and setbacks

3.14 Hoistway clearances

3.15 Multiple hoistways

3.16 Traveling cables and junction boxes

3.17 Door and gate equipment

3.18 Car frame and stiles

3.19 Guide rails, fastenings and equipment

3.20 Governor rope

3.21 Governor releasing carrier

3.22 Wire rope fastening and hitch plate

3.23 Suspension means

3.27 Crosshead data plate and rope data tags

3.28 Counterweight and counterweight buffer

3.29 Counterweight safeties

3.30 Speed test

3.33 Compensating ropes and chains

3.34 Earthquake inspection and tests

(seismic risk zone 2 or greater)

4 OUTSIDE HOISTWAY

4.1 Car platform guard

4.2 Hoistway doors

4.3 Vision panels

4.4 Hoistway door locking devices

4.5 Access to hoistway

4.6 Power closing of hoistway doors

4.7 Sequence operation

4.8 Hoistway enclosure

4.9 Elevator parking device

4.10 Emergency doors in blind hoistways

4.12 Standby power selection switch

2 MACHINE ROOM (continued) OK NG NA

5 PIT

5.1 Pit access, lighting, stop switch and condition

5.2 Bottom clearance, runby and minimum

refuge space

5.3 Final and emergency terminal stopping device

5.4 Normal terminal stopping devices

5.5 Traveling cables

5.6 Governor rope tension device

5.7 Car frame and platform

5.8 Car and counterweight safeties

and guiding members

5.9 Buffers and emergency terminal

speed limiting devices

5.10 Compensating chains, ropes and sheaves

5.12 Car buffer

5.13 Guiding members (rails, rollers, slides)

5.16 Earthquake inspection and tests

(seismic risk zone 2 or greater)

6 FIREFIGHTERS’ SERVICE (FEO)

6.1 A17.1b-1973 through A17.1b-1980

6.2 A17.1-1981 through A17.1b-1983

6.3 A17.1-1984 through A17.1a-1988 and A17.3

6.4 A17.1b-1989 through A17.1b-2000

6.5 A17.1-2000 and B44-00

6.6 A17.1-2004 and B44-04

6.7 A17.1-2007 and B44-07

6.8 A17.1-2010 and B44-10

6.9 A17.1-2013 and B44-13

Comments: ______________________________________________________________

Reprinted from ASME A17.2-2014, by permission of The American Society of Mechanical Engineers. All rights reserved.

Address: 7215 Goddard Dr., Malmstrom, MT 59402
ID No: MAFB Building 1012
Rated Load: 2500
Routine: On
Periodic: Off
Acceptance: Off
Inspected By: Robert Helms / August 07, 2024
Certifying Organization: Montana Building Services, LLC
Code Edition: ASME A17.1
Certificate No: N/A
Speed: 150
Class: N/A
Passenger: On
Freight: Off
4:
1 OK: On
1 NG: Off
1 NA: Off
12 OK: Off
12 NG: Off
12 NA: On
10 OK: Off
10 NG: Off
10 NA: On
9 OK: Off
9 NG: Off
9 NA: On
8 OK: On
8 NG: Off
8 NA: Off
7 OK: On
7 NG: Off
7 NA: Off
6 OK: On
6 NG: Off
6 NA: Off
5 OK: On
5 NG: Off
5 NA: Off
4 OK: On
4 NG: Off
4 NA: Off
3 OK: Off
3 NG: Off
3 NA: On
2 OK: On
2 NG: Off
2 NA: Off
6:
1 OK: Off
1 NG: Off
1 NA: On
2 OK: Off
2 NG: Off
2 NA: On
3 OK: Off
3 NG: Off
3 NA: On
4 OK: Off
4 NG: Off
4 NA: On
5 OK: Off
5 NG: Off
5 NA: On
6 OK: Off
6 NG: Off
6 NA: On
7 OK: Off
7 NG: Off
7 NA: On
8 OK: Off
8 NG: Off
8 NA: On
9 OK: On
9 NG: Off
9 NA: Off
3:
8 OK: On
8 NG: Off
8 NA: Off
9 OK: On
9 NG: Off
9 NA: Off
10 OK: On
10 NG: Off
10 NA: Off
11 OK: On
11 NG: Off
11 NA: Off
12 OK: On
12 NG: Off
12 NA: Off
13 OK: On
13 NG: Off
13 NA: Off
14 NG: Off
14 NA: Off
14 OK: On
15 OK: Off
15 NG: Off
15 NA: On
16 OK: On
16 NG: Off
16 NA: Off
17 OK: On
17 NG: Off
17 NA: Off
18 OK: On
18 NG: Off
18 NA: Off
19 OK: On
19 NG: Off
19 NA: Off
20 NG: Off
20 OK: On
21 OK: On
21 NG: Off
21 NA: Off
22 OK: Off
22 NG: Off
22 NA: On
23 OK: On
23 NG: Off
23 NA: Off
27 OK: On
27 NG: Off
27 NA: Off
28 OK: On
28 NG: Off
28 NA: Off
29 OK: Off
29 NG: Off
20 NA: Off
29 NA: On
30 OK: On
30 NG: Off
30 NA: Off
34 OK: Off
34 NG: Off
34 NA: On
33 OK: Off
33 NG: Off
33 NA: On
1 OK: On
1 NG: Off
1 NA: Off
2 OK: On
2 NG: Off
2 NA: Off
3 OK: On
3 NG: Off
3 NA: Off
4 OK: On
4 NG: Off
4 NA: Off
5 OK: On
5 NG: Off
5 NA: Off
6 OK: On
6 NG: Off
6 NA: Off
7 OK: On
7 NG: Off
7 NA: Off
5:
1 OK: On
1 NG: Off
1 NA: Off
4 OK: On
4 NG: Off
4 NA: Off
5 OK: On
5 NG: Off
5 NA: Off
6 OK: On
6 NG: Off
6 NA: Off
7 OK: On
7 NG: Off
7 NA: Off
12 OK: On
12 NG: Off
12 NA: Off
13 OK: On
13 NG: Off
13 NA: Off
16 OK: Off
16 NG: Off
16 NA: On
10 OK: Off
10 NG: Off
10 NA: On
8 OK: On
8 NG: Off
8 NA: Off
9 OK: On
9 NG: Off
9 NA: Off
2 OK: On
2 NG: Off
2 NA: Off
3 OK: On
3 NG: Off
3 NA: Off
2:
8 OK: On
8 NG: Off
8 NA: Off
9 OK: On
9 NG: Off
9 NA: On
10 OK: Off
10 NG: Off
10 NA: On
11 OK: On
11 NG: Off
11 NA: Off
12 OK: On
12 NG: Off
12 NA: Off
38 OK: Off
38 NG: Off
38 NA: On
40 OK: On
40 NG: Off
40 NA: Off
41 OK: On
41 NG: Off
41 NA: Off
42 NG: Off
42 NA: On
42 OK: Off
1 OK: On
1 NG: Off
1 NA: Off
2 OK: On
2 NG: Off
2 NA: Off
3 NA: Off
3 OK: On
3 NG: Off
4 OK: On
4 NG: Off
4 NA: Off
5 OK: On
5 NG: Off
5 NA: Off
6 OK: On
6 NG: Off
6 NA: Off
7 OK: Off
7 NG: Off
7 NA: On
29 OK: On
29 NG: Off
29 NA: Off
28 OK: On
28 NG: Off
28 NA: Off
27 OK: Off
27 NG: Off
27NA: On
26 OK: Off
26 NG: Off
26 NA: On
25 OK: On
25 NG: Off
25 NA: Off
24 OK: Off
24 NG: Off
24 NA: On
13 NA: Off
14 NG: Off
14 NA: Off
13 OK: On
13 NG: Off
14 OK: On
23 OK: Off
23 NG: Off
23 NA: On
22 OK: Off
22 NG: Off
22 NA: On
21 OK: On
21 NG: Off
21 NA: Off
20 OK: Off
20 NG: Off
20 NA: On
19 OK: Off
19 NG: Off
19 NA: On
18 OK: Off
18 NG: Off
18 NA: On
17 OK: On
17 NG: Off
17 NA: Off
16 OK: On
16 NG: Off
16 NA: Off
15 OK: On
15 NG: Off
15 NA: Off
1:
1 OK: On
1 NG: Off
1 NA: Off
2 OK: On
2 NG: Off
2 NA: Off
3 OK: On
3 NG: Off
3 NA: Off
4 OK: On
4 NG: Off
4 NA: Off
5 OK: On
5 NG: Off
5 NA: Off
6 OK: On
6 NG: Off
6 NA: Off
7 OK: On
7 NG: Off
7 NA: Off
8 OK: On
8 NG: Off
8 NA: Off
9 OK: On
9 NG: Off
9 NA: Off
10 OK: On
10 NG: Off
10 NA: Off
11 OK: Off
11 NG: Off
11 NA: On
12 OK: On
12 NG: Off
12 NA: Off
13 OK: On
13 NG: Off
13 NA: Off
14 OK: On
14 NG: Off
14 NA: Off
15 OK: On
15 NG: Off
15 NA: Off
16 OK: On
16 NG: Off
16 NA: Off
17 OK: Off
17 NG: Off
17 NA: On
18 OK: On
18 NG: Off
18 NA: Off
19 OK: On
19 NG: Off
19 NA: Off
20 OK: Off
20 NG: Off
20 NA: On
Sig:
Comments: See Attached

File details come from the government source that posted it. Updated .