This Statement of Work (SOW) details lease and maintenance requirements for washers and dryers at Fairchild Air Force Base in Washington State. The contract requires the contractor to furnish, install, and maintain 32 washers, 8 dryers, 24 stackable dryers, and 64 stacked washer/dryer units across multiple buildings, with specific requirements for equipment specifications. Machines must be commercial-grade, white in color, no older than 8 years, non-coin operated, and include control numbers and service contact information.
Key performance requirements include providing operational machines within 1-2 business days of notification, offering preventative maintenance schedules, maintaining service during normal business hours (Monday-Friday, 8 AM-4 PM), and replacing machines that do not meet operational standards. The equipment will be installed in various dormitory and living buildings, with precise dimensional requirements for different building types. The contractor is responsible for connecting machines to existing utilities and must comply with environmental guidelines and fire safety specifications.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 25QA953 Amend 004.pdf | ||
| 25QA953 Amend 003.pdf | ||
| 25QA953 Amend 002.pdf | ||
| 25QA953 Amend 001.pdf | ||
| Attachment 2 - Pricing Schedule.xlsx | XLSX spreadsheet | |
| Attach 1. SOW combined with salient characteristics.pdf | ||
| Attachment 2 - Pricing Schedule.xlsx | XLSX spreadsheet | |
| FA462025QA953 Combo.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FA462025QA953
Attach 1. SOW with Salient Characteristics Rev. 1 19AUG25
STATEMENT OF WORK
WITH SALIENT
CHARACTERISTICS
FOR
LEASE AND MAINTENANCE OF WASHERS AND DRYERS
Fairchild AFB, WA
8/19/25
1. DESCRIPTION OF SERVICES. The contractor shall furnish, install, maintain, and as required, relocate washers and dryers at various locations on Fairchild AFB, WA. The washers and dryer will meet requirements as needed per location installed, in order to provide satisfactory laundry facilities for the residents the will be using them. UH Management upon discovery will report non-operational or damaged equipment to the contractor for repair. Services shall be performed in accordance with manufacturer's recommended commercial practices and this Statement of Work (SOW).
1.2. SCOPE OF WORK. In accordance with AFI 32-6000, the contractor shall furnish, install, and maintain fully operational washers and dryers specified in Appendix A, in good operating condition at various locations on Fairchild AFB, WA. Services shall be performed in accordance with manufacturer's recommended commercial practices. All equipment shall be designed for commercial use, and the contractor shall connect these washers and dryers to existing utilities and vents. Furthermore, any replaced machines shall meet current environmental (Green) guidelines. The products will be used daily for laundry washing and drying purposes only, providing adequate resources for heath and wellness standards.
1.2.1. Electric Washers (Stand Alone and Stackable Models) shall have a minimum tub capacity of 14 pounds, dry weight, and shall not utilize more than 50 gallons of water per load washed. Washers shall have standard hot and cold water connections and be capable of operating on a 20-amp circuit during normal conditions. The electrical power available is 120 volts, single phase, AC, 60 hertz. The washers shall have a minimum of one speed, three cycles including normal, wash and wear, and delicate, and, three controllable temperature settings for hot, cold, and warm. All equipment must meet the size ranges specified in the Pricing Schedule. Side load washers are acceptable for stand-alone units.
1.2.2. Electric Dryers (Stand Alone and Stackable Models) shall be single-load type for operation on a 30-amp circuit under normal conditions. The electrical power available is 208 volts, single phase, AC, 60 hertz. Dryers must contain a timer capable of selecting drying periods for a desired fabric type. Machines must be shockproof and contain a safety start button plus a safety latch to shut off machines when the door is open. Dryer vent hoses shall be attached with clamps. All equipment must meet the size ranges specified in the descriptions below.
DESCRIPTION QUANTITY
STACKED DRYER (No MIN or MAX Dimensions) 24 WASHER (No MIN or MAX Dimensions) 32 DRYER (No MIN or MAX Dimensions) 8
STACKED WASHER DRYER MIN = (71.75"H*27.125"D*23.875"W) MAX = 64
75'H*27.5"D*27.5"W
DRYER CORD 4FT 36
DRYER CORD 6FT 60
VENT KIT 5' VENT AND 2 CLAMPS 36
VENT KIT 10' VENT AND 2 CLAMPS 60
WASHER HOSE STAINLESS STEEL 4' T0 5' 96
1.2.3. The contractor shall provide an equipment list at the time of the pre-performance conference identifying the make, model number, serial number and age of equipment. A the time of their installation, appliances will be no older than eight (8) years old based on the original manufacturers date. This includes but is not limited to machines that are replaced due to age or reliability. Machines shall be white in color and will not be coin operated. A control number, at least 1" x 1" in size, will each be assigned and displayed in a conspicuous place on the front right or top right of each machine. A placard or decal with the telephone number of the Quality Assurance Personnel (QAP),), or Building/Dormitory manger will be displayed prominently in the immediate area of the machines with the instructions to call in those machines which malfunction." The placards will instruct the caller to provide the time, date, machine number, and their name and grade with a call back number. The purpose is to expedite access to the equipment through a central control point. Control numbers shall be furnished to the QAP listed by building. If the appliance is located in a modified dormitory, the "Pod" alpha/numerical designator will provided as well. (i.e., "Bldg 2266, Pod 4D")
1.3. Any required addition or subtraction of units from the workload data listed in Appendix A. will be accomplished via bilaterally modification at a rate to be negotiated between the contractor and the government. The contractor shall furnish and install additional machines or remove excess machines within five calendar days (or longer, if approved) after the execution of a bilateral modification.
1.4. The Contractor shall provide the Government at the pre-performance meeting with any planned inspection and preventative maintenance schedules for the installed equipment. The contractor shall provide the Government with a service call number that shall be toll free or at the contractor's expense. The government will provide the contractor a list of personnel authorized to place calls for service.
1.5. Service Calls. All service visitations will be made during normal business hours, Monday through Friday, 8:00 AM through 4:00 PM, excluding federal holidays (New Year's Day, Martin Luther King Jr.'s Birthday, Presidents Day, Memorial Day, Independence Day, Labor Day, Columbus Day, Veterans Day, Thanksgiving Day, and Christmas Day
1.6. All machines shall be replaced or returned to an operational condition within two "normal" business days of contractor notification unless the machine is the sole washer or dryer at its location, in which case the contractor shall provide an operational machine, either by repair or replacement, within 24 hours (1 normal business day). Upon completion of the repairs or replacement, the contractor shall contact the QAP, or building/dormitory manager and provide the building number, control number, type of machine, day and time the machine was replaced or made operational.
1.6.1. If a machine was not returned to a normal operating condition within the allowed timeframes, the monthly price for that piece of equipment shall be pro-rated and deducted for each calendar day the machine was non-operational. The contractor shall provide an updated equipment list in the event that a machine is replaced.
1.7. Any personal items of equipment, clothing, jewelry, monies, etc. found on the premises by contractor employees shall be turned into the dormitory manager or the
QAP.
1.8. Any act of theft, vandalism or apparent willful damage discovered by the contractor shall be reported immediately to the Base Security Police Operations and the Contracting
Officer. The contractor shall provide a copy of the police report to the QAP. Losses resulting from such damaged, broken or stolen equipment shall be the responsibility of the contractor.
2. GOVERNMENT FURNISHED PROPERTY AND SERVICES. The Government will provide, repair, and maintain the premises where each contractor-owned appliance is installed, to include electrical outlets, plumbing, and dryer vents. The contractor shall not make alterations to Government real property. The contractor shall be responsible for connection to the plumbing, electrical outlets and vents.
3. CONTINUATION OF ESSENTIAL DOD CONTRACTOR SERVICES
DURING CRISIS. IAW DoDI 3020.37 (Continuation of Essential DoD Contractor Services During a Crisis), and applicable Air Force implementation, unless otherwise directed by an authorized Government representative, it is determined that Lease/Maintenance of Washers and Dryers as identified in this PWS are not required during a crisis.
4. APPENDICES.
Appendix A - Workload Data
APPENDIX A
Building No. Washers Dryers Stackable Dryers
Stacked Washer/Dryer
3 (FD) 3 3
1314 (FD) 1 1
2256 (UH) 6 6
2257 (UH) 6 6
2258 (UH) 6 6
2259 (UH) 6 6
2266 (UH) 10**
2268 (UH) 10**
2272 (UH) 4 4 4
2274 (UH) 10**
2276 (UH) 10**
2278 (UH) 10**
2279 (UH) 10**
TOTAL 32 8 24 64
Buildings 2256, 2257, 2258, and 2259: These buildings have laundry rooms that house 8 washers and 8 stackable dryers each. These units have no min or max dimensions for size and have electric outlets, drains for washers, and dryer vents behind or near them.
Building 2272: this building has two laundry rooms. One on fourth floor that houses 4 washers and 4 dryers with no min or max dimensions. On the basement level there is a laundry room that houses 4 stacked washer dry units min dimensions 71.75”H*27.125”D*23.875”W and max dimensions 75"H * 27.5"D * 27.5”W.
Buildings 2266, 2268, 2274, 2276, 2278, and 2279: these buildings house 10 stacked washer dryer units each. These units have min dimensions 71.75”H*27.125”D*23.875”W and max dimensions 75"H * 27.5"D * 27.5”W. and require a 6ft dryer cord so they can be plugged in before being position in the laundry closet in each of the pod style rooms.
* The 75" max is to comply with fire safety because there needs to be a minimum clearance between the units and the allocated sprinkler heads.