Attachment 2a - Structure and Building Layout.pptx
PPTX presentation 2 MB Posted
- Attached to
- Emergency Management Furniture
- Solicitation number
- FA461326Q0024
About this file
This file is a building layout and furniture inventory diagram for an Emergency Operations Center (EOC) configuration. The layout depicts Building 328 at a 90 Megawatt (MW) facility with 90 Command Element Support (CES/CEX) personnel, showing the spatial arrangement of multiple rooms (Rooms 5-24) and their associated furniture and equipment. The diagram identifies specific furniture quantities and types required, including U-desks in left and right configurations (totaling 12 units), high-back chairs (42), mid-back chairs (20), stand desks (18), various shelf units (5-shelf: 4 units; 2-shelf: 22 units), file/credential cabinets (3), pedestals (18), conference tables (1), floor mats (33), steel tables (5), wall lockers (15), supply cabinets (3), and equipment rooms designated for training and real-world operations. The layout indicates delivery entry points, designated ward areas (left and right), an EOC desk configuration area (24 stations), transaction center (23 stations), mechanical room, communications room, and a gated/enclosed yard. The configuration notes that Building 328 meets approximately 90% of UFC (Unified Facilities Criteria) standards for EOC setup but lacks break-out rooms. The diagram is referenced as CLIN 0025 and is part of the solicitation documentation for the Air Force's Emergency Management Furniture procurement, supporting the 90th Contracting Squadron's RFQ issued to small businesses for furnishing and equipping this EOC facility.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Ward (R) (6) Ward (L) (5) EOC Desk (24) Supply Cabinet (3) Transaction Ctr (23) High-back Chair (42)
CUI
Mech Room Comm Room Equipment (Training) Equipment (Real-World)
Room Room Room Room Room Room Room Room
CLIN 0025
R L
U-Desk1 (L) (4)
R U-Desk3 (L) (2) Shared Desk (2) U-Desk1 (R) (5) U-Desk2 (L) (1) U-Desk2 (R) (2) U-Desk3 (R) (1) 5-Shelf (4) 2-Shelf (22) File/Cred (3)
Pedestal (18) Conf. Table (1)
Floor Mat (33) Stand Desk (18) Mid-Back Chair (20) R R R R R
Gated/Enclosed Yard Delivery Entry Delivery Entry N E W S
Steel Table (5) Wall Locker (15)
90 MW (90 CES/CEX) EOC Configuration
IAW UFC Standards (see previous slide), Bldg 328… Meets 90% of the standard Bldg 328 does not afford break-out rooms image19.png image20.jpg image12.png image13.png image14.png image15.png image16.png image17.png image18.png image1.jpeg image2.jpeg image3.png image4.jpeg
File details come from the government source that posted it. Updated .