This is a Statement of Work (SOW) for the design, manufacture, and delivery of one custom EOD Nuclear Response Trailer for the 5th Civil Engineer Squadron Explosive Ordnance Disposal (5 CES/CED) Flight at Minot Air Force Base, North Dakota, dated September 21, 2026.
The trailer must serve as a mobile command and life-support hub for Initial Response Force (IRF) and Response Task Force (RTF) teams during nuclear accident or incident response operations lasting 24+ hours without external utility connections. The operational environment requires the trailer to withstand extreme North Dakota conditions including sub-zero temperatures to -40°F, sustained winds to 25 mph, and heavy snow accumulation, while traversing unimproved gravel roads over up to two hours of transit time to remote Missile Alert Facilities and Launch Facilities. The contractor must perform all engineering, fabrication, and quality control to produce the trailer meeting four core contractor acquisition tasks: (1) engineering design with 3D CAD submission within 30 days of contract award, (2) transportation and delivery to Building 897, Minot AFB within 240 calendar days, (3) comprehensive technical documentation in electronic and print formats, and (4) structural engineering verification via Finite Element Analysis (FEA) prior to frame fabrication.
The trailer must meet specific technical parameters: 46-50 feet overall length, maximum 8.5 feet width, maximum 13.5 feet height, minimum 8.0 feet interior headroom, and maximum 30,000 lbs GVWR when fully loaded. Structural requirements mandate either heavy-wall structural aluminum (2"x10" box tubing, 6061-T6 alloy) or galvanized steel I-beam framing with torsion or slipper-spring suspension providing minimum 21,000 lbs combined GAWR. The chassis must support a 3,500 lbs tactical UTV in the rear garage zone via 12-inch maximum floor crossmember spacing. The exterior skin must be screwless, weather-tight Ultramarine Air Force Blue composite or aluminum composite material (minimum 0.050-inch) with a seamless aluminum roof featuring sloped profile for snow shedding. The trailer includes integrated sub-basement storage with minimum 40 feet length accessible via weather-sealed baggage doors. A two-5/16-inch gooseneck coupler rated for full GVWR and capable of being towed by a Ford F-450 is required, with gooseneck pin weight not exceeding 6,000 lbs. The trailer must include automatic hydraulic four-post self-leveling jacks (16-inch minimum stroke) and backup manual gooseneck jacks.
Thermal performance requirements mandate maintaining +68°F interior temperature when ambient is -40°F and +74°F when ambient reaches +100°F. High-efficiency insulation must prevent interior condensation and thermal bridging via static thermal engineering heat-load calculations rather than physical chamber testing. A heavy-duty thermal-barrier draft curtain or vestibule entrance door, heated aluminum entry step with low-draw heating elements, and 110V electric radiant floor heating in the habitation zone are required. The HVAC baseline configuration must provide either a multi-zone mini-split heat pump system with auxiliary low-ambient heating (minimum 36,000 BTU total capacity) or minimum three commercial-grade 15,000 BTU roof-mounted heat pump units with integrated heat strips. Alternative custom-engineered heating solutions including hydronic or hybrid systems are permitted if verifiable engineering substantiation is provided. Active dehumidification (minimum 30 pints water extraction per day) and HEPA filtration in the primary Command Zone are mandatory.
The onboard power system consists of a minimum 20 kW liquid-cooled diesel generator (Powertech or equal) with integrated 120V block heater, oil pan heater, and heated fuel/water separator for cold-start reliability. The generator must draw from a dual-tank system of two 30-gallon diesel fuel tanks with 12V DC electric transfer pump, capable of providing minimum 24 hours continuous operation at 70% sustained load without refueling. Electrical distribution requires a 100 Amp main service panel configured for 120/240V single-phase power with 12 spaces/24 circuits, supplemented by a 50A motor base power inlet with 25-foot heavy-duty shore power cord. An intelligent Automated Energy Management System (EMS) must monitor shore power loads and dynamically shed non-critical circuits before exceeding 80% capacity (40A per leg), with automatic restoration when demand decreases. The battery bank must consist of minimum three 12V Lithium Iron Phosphate (LiFePOସ) 100Ah deep-cycle batteries with internal heating elements. Solar infrastructure pre-wiring must include dedicated roof-entry plate, 10 AWG cabling to battery compartment, and pre-installed 40-amp Maximum Power Point Tracking (MPPT) charge controller. EMS load priority hierarchy designates command center workstations, communications/radio systems, mission equipment outlets, CBRN positive-pressure filtration, primary HVAC blowers, and operational/emergency lighting as Priority 1 (never shed); secondary HVAC elements and cabin outlets as Priority 2 (staged shed); and water heater elements, galley appliances, and exterior lighting as Priority 3 (first to shed).
Water and plumbing systems must include minimum 100-gallon fresh water, 45-gallon grey water, and 42-gallon black water holding tanks with dual-stage inline water filtration for shore/city water inputs. All plumbing lines, tanks, and valves must run inside the heated envelope with thermostatically controlled 12V heating pads on fresh, grey, and black water tanks and exterior dump valves preventing freezing to -40°F. A commercial-grade tankless (on-demand) water heater provides hot water supply. The trailer must feature city water and gravity fill inlets with integrated sewer hose and enclosed storage carrier (minimum 10-foot hose). A weatherproof 110V receptacle wired to the generator panel allows the towing vehicle's engine block heater to plug directly into trailer generator power.
The interior comprises four distinct functional zones: Zone 1 (Front Habitation & Wet Zone, approximately 12 feet) featuring minimum three foldable double bunk beds (six berths total) with heavy-duty aluminum frames, 6-inch high-density memory foam mattresses, blackout privacy curtains, individual USB-A/USB-C charging ports, and dedicated LED reading lighting; a GSA Class 6 high-security safe (Federal Specification AA-F-358, 16"W x 19"D x 12.5"H, ~150 lbs) for sensitive storage; and a pre-plumbed combination washer/dryer unit (Splendide 2100XC or equal). Zone 2 (Mid-Ship Command & Culinary Zone, approximately 22 feet) includes a 244-inch flush-floor curbside slide-out compartment with fixed lower workstation desks, overhead cabinets, electrical and data hookups, TV mounts, and dry-erase whiteboard-finished wall surface; a kitchenette with lockable 16-gauge commercial aluminum cabinets with positive-locking latches, laminate countertops, farmhouse-style deep basin sink, 10.0 cubic foot AC/DC compatible refrigerator, 1.1 cubic foot electric convection microwave oven, and electric cooktop (Liquid Propane Gas and gas-powered appliances are strictly prohibited); and two flush-mounted pre-wired HDMI/USB media input panels adjacent to Smart TV mounts. Zone 3 (Full Bathroom Package & Decontamination Routing) must be positioned immediately adjacent to the rear tactical garage with direct access door to prevent contamination cross-flow; features seamless fiberglass walls, black coin rubber flooring, aluminum-framed cabinets, and black HDPE shelves; includes a fully enclosed 36"x36" minimum rectangular fiberglass shower with secure door, foot-pedal RV-style toilet plumbed to black water tank, laminate cabinet vanity with integrated hand wash sink and faucet, and 12V roof-mounted exhaust vent supplemented by 1,000W electric wall heater.
Zone 3 also mandates a permanently installed CBRN (Chemical, Biological, Radiological, Nuclear) filtration and positive pressure system protecting Zones 1 and 2, consisting of high-static-pressure blower, sealed filter housing, dedicated intake/exhaust ports, and combination filter cartridge providing minimum 99.97% efficiency for 0.3-micron particulates with activated carbon for gas-phase contaminants. The system must deliver minimum 120 CFM filtered air to sealed crew zones and generate/maintain continuous internal positive pressure of +0.20 inches water column above external atmospheric pressure, controlled by dedicated switch on interior control panel and hardwired to Priority 1 circuit (never shed by EMS). Positive pressure capability must be demonstrated and verified with digital manometer during final acceptance at Minot AFB. An exterior gross decontamination station on the curbside near the garage ramp must provide weatherproof, heated exterior shower/washdown port connected to onboard water heater and freshwater pump for decontaminating bomb suits, robots, and UTVs prior to interior entry. Zone 4 (Rear Tactical Garage & Auxiliary Living Zone, approximately 14 feet) features minimum 14-foot clear garage space with heavy-duty drop-down rear ramp door rated for minimum 4,000 lbs rolling vehicle load, 12V 55W LED loading lights, and remote-controlled 12-foot LED incident lighting mast.
The garage floor must withstand high-impact concentrated wheel point loads from 3,500 lbs tactical UTVs and tracked robotic platforms via floor crossmembers spaced maximum 12-inch centers using heavy-wall structural box tubing. The floor surface consists of minimum 3/4-inch exterior/marine-grade plywood or composite subfloor completely encapsulated with seamless, high-pressure applied commercial-grade industrial polyurea/polyurethane elastomeric coating (minimum 80 mils/0.080-inch thickness) incorporating aggressive non-skid texturing for positive traction when wet. The coating must roll upside and front walls to minimum 6-inch height establishing a sealed washdown basin with minimum two flush-mounted, sealable floor drains featuring removable sediment traps (bare metal grates or open floor penetrations strictly prohibited). Recessed aluminum E-track flush-mounted into garage floor (minimum 40 linear feet) secures vehicles and heavy gear. Zone 4 includes one heavy-duty rollover sleeper sofa mounted to curbside wall converting into extra bed when garage is cleared; minimum 48-inch-wide wardrobe cabinet with built-in clothes rod and shelf for cold-weather outerwear; heavy-duty reinforced locker/rack capable of supporting four 100-lb EOD bomb suits with dedicated forced-air ducting from HVAC system for rapid drying; and minimum 4,500 lb 12V DC electric winch with synthetic rope floor-mounted at forward bulkhead for loading disabled UTVs, robots, or mission cargo.
Additional Zone 4 features include one high-capacity (minimum 75-100 liter) compressor-driven chest-style refrigerator/freezer (Dometic, ARB, or approved ruggedized equivalent) in dual-voltage (12V DC/110V AC) configuration mounted on heavy-duty lockable full-extension slide tray in rear garage or exterior weatherproof compartment, and one built-in marine/commercial-grade automatic ice maker installed in forward kitchenette plumbed to freshwater system with dedicated inline filtration producing minimum 20-25 lbs ice per day.
Tactical EOD mission support equipment includes minimum six SCBA brackets (three per side) anchored to structural garage framing inside rear ramp door; dedicated ventilated storage lockers for bomb suits with integrated heavy-duty hangers and 12V forced-air ventilation fans; minimum two dedicated high-amperage 120V AC charging receptacles adjacent to heavy-duty floor tie-down anchors for tactical unmanned ground vehicle (UGV/Robot) charging; and dedicated onboard pneumatic air compressor with plumbed outlets in garage area for pneumatic tools and vehicle tire inflation.
Command, Control, & Communications (C3) structural infrastructure (active IT equipment is Government-Furnished/Government-Installed) includes rigid external mounting brackets and weather-tight RF/coaxial cable feed-through ports on exterior wall supporting tactical field antennas; reinforced walkable roof plate (minimum 3'x3') positioned above C2 slide-out for satellite communications and radio antenna arrays with minimum 2-inch diameter weatherproof conduit pass-through directly into interior C2 server rack maintaining envelope thermal integrity; minimum 12U wall-mounted vibration-isolated IT rack enclosure with integrated 1500VA Uninterruptible Power Supply (UPS) for network routers and switchgear; weatherproof exterior HDMI/Ethernet panel for external camera feeds and video downlinks; integrated weatherproof exterior C2 briefing station on curbside comprising lockable environmentally sealed compartment housing minimum 40-inch LED ruggedized/outdoor monitor pre-wired to interior server rack, minimum two 110V/120V GFCI weatherproof receptacles, four USB charging ports, two weatherproof RJ-45 Cat6 data ports linked to secure network switch, lockable heavy-duty fold-down aluminum desk rated for minimum 100 lb working load, and flush-mounted exterior LED scene lighting with 25-foot motorized commercial awning featuring remote control.
Tactical lighting systems consist of two commercial-grade non-recessed 12V LED exterior scene lights (minimum 14"x2.5", minimum 3,000 lumens each, IP67 waterproof rating) on utility side; one pair commercial-grade exterior LED loading lights (minimum 1,500 lumens each) above rear ramp door; and integrated continuous LED strip lighting along curbside motorized awning providing minimum 1,000 lumens.
Deliverables include: A001—3D CAD Design Drawings & System Schematics (high-resolution electronic PDF via email/secure transfer) due within 30 calendar days of contract award to 5 CES/CED requirements owner; A002—EOD Nuclear Response Trailer Delivery (fully assembled compliant mobile trailer) due within 240 calendar days of contract award with early delivery authorized at no additional cost to Building 897, Minot AFB, ND 58705; A003—Technical Documentation & Manuals (three durable bound print manuals and one searchable PDF) with electronic copies due concurrently with or prior to trailer delivery and print manuals due upon final physical delivery; and A004—Chassis Structural & Deflection Report (FEA) (certified engineering calculation proving load deflection limits) due within 30 calendar days of contract award prior to frame fabrication with Government review within 15 calendar days.
The Contractor is solely responsible for product quality and rigorous execution of all engineering and manufacturing processes per Federal Acquisition Regulation (FAR) 52.212-4. Government review of design drawings is strictly for compliance validation and does not relieve the Contractor of liability for structural or system performance. Final acceptance inspection at Minot AFB is based upon Contractor-furnished Certificate of Conformance (CoC) confirming full SOW specification compliance. Per FAR 52.212-4(o), acceptance of the CoC does not waive Government's right to seek non-cost repair, replacement, or equitable price reduction under latent defect provisions should thermal or HVAC systems fail to maintain outcome thresholds (+68°F heating at -40°F ambient; +74°F cooling at +100°F ambient) during field operations. Thermal compliance must be proven via static engineering calculations and heat load modeling during design submittals rather than physical cold-room environmental chamber testing.
Warranty requirements per FAR 12.205 and FAR 52.212-4(o) mandate Contractor's standard commercial warranty with minimum coverage: three-year limited warranty for structural components (chassis frame rails, crossmembers, wall studs, roof bows, primary structural weldments); three-year limited warranty for all custom builder-manufactured components; one-year limited warranty for electrical wiring and distribution systems; and assignment of OEM warranties for third-party commercial components (diesel generator, HVAC units, tankless water heater, leveling jacks, tires) directly to Government upon final acceptance. The Government has authority to verify the CBRN positive pressure system's ability to achieve and maintain +0.20 inches water column with digital manometer during final acceptance. All Contractor delivery and setup personnel must comply with Minot AFB security checkpoint requirements, including REAL ID Act of 2005 identity verification and standard commercial vehicle gate inspections, with delivery scheduled during normal business hours 0830-1530 Central Time Monday-Friday excluding federal holidays.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STATEMENT OF WORK (SOW)
EOD Nuclear Response Trailer
5 CES/CED Explosive Ordnance Disposal
Minot Air Force Base, North Dakota
Date: 21 September 2026
1.0 INTRODUCTION & MISSION CONTEXT
1.1 Scope of Requirement
The 5th Civil Engineer Squadron Explosive Ordnance Disposal (5 CES/CED) Flight requires one (1) custom-manufactured, weather-resilient, self-sustaining mobile operations and life-support trailer. This specialized vehicle will serve as a continuous, on-scene command and sustainment hub for Initial Response Force (IRF) and Response Task Force (RTF) teams during multi-day, full-spectrum nuclear accident or incident response operations.
1.2 Operational Environment
The trailer must operate reliably in the extreme environmental conditions characteristic of the northern and central North Dakota plains, including sub-zero winter temperatures down to -40°F, high winds up to 25 mph sustained, and heavy snow accumulations. EOD response operations frequently take place at remote Missile Alert Facilities (MAFs) and Launch Facilities (LFs) across the Minot Air Force Base Missile Complex, requiring up to two (2) hours of transit time each way over unimproved, washboard, or snow-covered gravel roads. Due to the critical nature of these operations and the projected 24-hour arrival timeline for external Department of Energy (DOE) support assets, the trailer must support continuous, independent field operations for a six-person EOD team for extended durations (+24 hours) without external utility connections.
2.0 CONTRACTOR ACQUISITION TASKS
2.1 Task 1: Engineering Design, Technical Approval, and
Production
2.1.1 Engineering and Fabrication: The Contractor must perform all necessary engineering, structural design, material procurement, fabrication, and quality control assembly to produce one (1) new EOD Nuclear Response Trailer meeting the technical performance requirements outlined in this Statement of Work.
2.1.2 3D CAD Submittal (Deliverable A001): Prior to initiating physical fabrication, the Contractor must deliver complete 360-degree, three-dimensional Computer-Aided Design (CAD) drawings and comprehensive system schematics (including structural, plumbing, HVAC, and electrical layouts) to the Government for review and formal approval.
2.1.3 Requirements Coordination: The Contractor must coordinate closely with the 5 CES/CED requirements team throughout the engineering phase to address and resolve design questions.
2.1.4 Design Review Authority: The Government's review of the design drawings is for compliance validation only and does not authorize or constitute a vehicle for unilateral scope changes. If the Government requires more than ten
(10) business days to complete its review, a day-for-day schedule extension will be bilaterally applied to the delivery timeline.
2.2 Task 2: Transportation and Delivery
2.2.1 Delivery Destination (Deliverable A002): The Contractor must transport and deliver the completed, fully assembled trailer to the 5 CES/CED EOD facility (Building 897, Minot Air Force Base, ND 58705).
2.2.2 Delivery Hours: The Contractor must schedule delivery during normal business hours: 0830 to 1530 Central Time, Monday through Friday, excluding federal holidays.
2.2.3 Base Access & Security Protocol: All Contractor delivery and setup personnel must comply with Minot Air Force Base security checkpoint requirements. This includes complying with the REAL ID Act of 2005 for identity verification and passing standard commercial vehicle gate inspections. The Government will provide entry routing information prior to delivery from the Commercial Vehicle Gate to Building 897.
2.3 Task 3: Technical Manual Requirements (Deliverable
A003)
2.3.1 Documentation Scope: The Contractor must provide comprehensive operator, maintenance, and system documentation covering all onboard mechanical, electrical, plumbing, and life-support systems for the EOD mobile facility/trailer.
2.3.2 Electronic Manuals: The Contractor must deliver complete electronic copies (searchable PDF format or Government-approved equivalent) of the operator and maintenance manuals concurrently with, or prior to, the physical delivery of the trailer.
2.3.3 Physical Manuals: The Contractor must deliver finalized, durable, bound hard-copy manuals upon final physical delivery and initial Government receiving inspection at the Minot Air Force Base EOD Facility in North Dakota.
2.3.4 Content Coverage: Manuals must include standard operating procedures
(SOPs), preventative maintenance schedules, troubleshooting matrices, schematics/wiring diagrams, and OEM component reference guides for all installed equipment and systems.
2.3.5 Pre‐Award Modifications: The Contractor may propose changes to this
Statement of Work, provided that the proposed changes meet all intended operational and safety functions prior to award. All proposed changes will, if accepted by the Government, become an integrated part of the Statement of Work upon contract award.
3.0 TRAILER DIMENSIONS, FRAME, &
STRUCTURAL SPECIFICATIONS
3.1 Frame & Exterior Shell
3.1.1 Chassis, Frame, and Structural Substructure: The Contractor shall engineer and construct an industrial-grade, commercial/military chassis and structural substructure designed to withstand sustained travel over unimproved, gravel, and washboard road conditions without permanent structural deformation, frame sag, or failure of the body seals. The chassis and superstructure must satisfy the following parameters:
3.1.1.1 Primary Structural Mainframe:
Option A (Preferred – All‐Tube Structural Aluminum): Main chassis frame rails shall consist of a minimum 2-inch by 10-inch heavy-wall structural aluminum rectangular box tubing (6061-T6 or 6005A-T6 structural alloy) or an engineered integrated double-hollow aluminum truss frame. C-channel or open-back frame rails are strictly prohibited.
Option B (Engineered Structural Steel): Minimum 10-inch (12-inch preferred) high-strength structural steel wide-flange I-beam or structural rectangular steel tubing, completely treated with hot-dip galvanization or a commercial multi-stage epoxy zinc-rich powder-coat system. Standard spray-on asphalt undercoating alone is strictly prohibited.
3.1.1.2 Crossmember & Outrigger Spacing:
Floor crossmembers in the Rear Tactical Garage (Zone 4) shall be spaced on a maximum of 12-inch centers utilizing structural box tubing to support concentrated wheel point loads from an outfitted UTV (up to 3,500 lbs.) and tracked robots.
Floor crossmembers in the Habitation and Command zones (Zones 1 and
2) shall be spaced on a maximum of 16-inch centers.
Wall vertical studs and roof bows shall be structural tubing spaced on a maximum of 16-inch centers.
3.1.1.3 Frame Deflection & Skin Integrity: The chassis and frame design shall limit longitudinal and torsional deflection to prevent shearing, buckling, or delamination of the screwless exterior skin during travel across washboard, uneven terrain, and unimproved access routes.
3.1.1.4 Mandatory Engineering Verification (Deliverable A004): The Contractor must submit a Finite Element Analysis (FEA) or certified structural engineering calculation report to the Government for review and approval prior to the start of frame fabrication. This report must mathematically demonstrate that frame deflection under a maximum loaded GVWR of 30,000 lbs. remains well within the adhesive manufacturer’s allowable shear and elongation tolerances across a temperature range of - 40°F to +100°F.
3.1.1.5 Exterior Skin: The exterior skin must be screwless, weather tight, and finished in Ultramarine (Air Force) Blue Sheets. To ensure structural integrity in extreme cold environments, the Government will accept either:
Composite Panel: Minimum 3 mm–4 mm thickness, screwless bonded commercial-grade panels.
Aluminum Composite Material (ACM): Heavy-duty metal exterior, minimum 0.050-inch, screwless bonded.
All proposed materials must be engineered to withstand extreme thermal expansion/contraction from -40°F to +100°F without buckling, cracking, or delaminating from the framework. Standard fiberglass/FRP panels are not acceptable due to cold-weather brittleness and impact risks at sub-zero temperatures.
3.1.2 Seamless Roof Profile: The roof must be a one-piece, seamless aluminum design, featuring a sloped profile to prevent heavy snow and water accumulation.
3.1.3 Undercarriage Protection: The chassis must feature integrated frame-protection bogey wheels at the rear to protect against ground and road strikes.
3.2 Physical Dimensions & Clearance Limits
To ensure standard permit-free transit on public highways in accordance with Department of Transportation regulations, the trailer must conform to the following dimensions:
| 3.2.1 | Overall | Length: Minimum 46 feet, maximum 50 feet. |
| 3.2.2 | Overall | Width: Maximum 8.5 feet (in towing configuration). |
| 3.2.3 | Interior | Headroom: Minimum 8.0 feet. | |
| 3.2.4 | Maximum | Overall | Height: Maximum 13.5 feet, measured from the |
ground to the highest point of the trailer roofline (including all rooftop climate control units, vents, and antenna mounts) when hitched to a towing vehicle.
3.3 Suspension, Axles, & Wheels
3.3.1 Axles & Running Gear: The Contractor must install a commercial-grade axle and suspension configuration (e.g., a spread-axle tri-axle configuration with torsion axles, or a tandem dual-wheel configuration with slipper-spring suspension) providing a minimum combined gross axle weight rating (GAWR) of 21,000 lbs. All axles must feature easy-access lubrication hubs and electric or electric-over-hydraulic brakes on all wheels.
3.3.2 Maximum Weight Rating (GVWR): The fully loaded Gross Vehicle Weight Rating (GVWR) of the trailer—comprising the dry chassis, all integrated subsystems, full fluids (water/fuel), and the maximum rated cargo payload (including designated UTV and mission gear)—shall not exceed 30,000 lbs.
3.3.3 Towing Vehicle Interface: The trailer shall be engineered to be safely towed by a standard, government-furnished Ford F-450 (Class 4) truck:
Coupler Type: Heavy-duty, adjustable-height 2-5/16-inch gooseneck coupler. Fifth-wheel or bumper-pull configurations are not acceptable.
Gooseneck Pin Weight: The loaded tongue/pin weight on the gooseneck coupler shall not exceed 6,000 lbs. (20% of maximum GVWR) to maintain the F-450 rear axle gross weight rating (GAWR) and payload limits.
3.3.4 Weight Distribution & Balance Analysis: The Contractor must perform a certified weight and balance analysis prior to physical delivery. Axle placements and interior layout must ensure proper weight distribution both when the garage is empty and when it is fully loaded with maximum designated cargo payload.
3.3.5 Tires & Wheels: The trailer must be equipped with commercial-grade, heavy-duty steel-belted radial tires mounted on heavy-duty wheels rated to handle the certified vehicle gross weight.
3.4 Coupling & Leveling Systems
3.4.1 Gooseneck Coupler Rating: Rated to safely handle the trailer's overall certified GVWR.
3.4.2 Automatic Hydraulic Leveling System: One (1) automatic, hydraulic, four-post self-leveling jack system with a minimum 16-inch stroke, with lifting and holding capacity sufficient to support the full certified GVWR.
3.4.3 Backup Manual Jack: One (1) backup, single-speed manual gooseneck jack rated to safely support the full certified GVWR.
3.5 Integrated Sub-Basement Storage
3.5.1 Sub‐Basement Enclosure: The trailer must feature an integrated, insulated aluminum sub-basement storage compartment running a minimum of 40 feet in length underneath the primary floor structure.
3.5.2 Baggage Access Doors: The compartment must be accessible via weather-sealed baggage doors (minimum of two 36" x 14" doors and four 72" x 14" doors) featuring positive-locking latches.
4.0 THERMAL PERFORMANCE & CLIMATE CONTROL
4.1 Four-Season Thermal Barrier Performance
4.1.1 High‐Efficiency Thermal Envelope: The Contractor must install high-efficiency insulation throughout the structure to establish a continuous, high-performance thermal barrier across the walls, floor, and ceiling.
4.1.2 Condensation & Thermal Bridging: The thermal insulation barrier must prevent interior condensation, eliminate thermal bridging, and maintain a stable internal temperature during active deployments.
4.1.3 Performance Validation Methodology: The performance threshold of the thermal barrier must be validated via standard, static thermal engineering heat-load calculations rather than requiring physical cold-room environmental chamber testing.
4.2 Entryway Draft Protection
4.2.1 Vestibule / Draft Curtain: The main entrance door must feature a heavy-duty, insulated thermal-barrier curtain or a secondary partition door (vestibule design) to prevent extreme cold-air drafts from immediately draining living space heat when personnel enter or exit.
4.2.2 Heated Entry Step: The slide-out aluminum entry step must feature a slip-resistant open-grid design and integrated low-draw heating elements to prevent ice accumulation and slip hazards.
4.3 Climate Control Performance
The Contractor must configure and calibrate the heating, ventilation, and air conditioning systems to maintain comfortable interior temperatures across all seasonal extremes:
4.3.1 Winter Heating Target: The heating systems must maintain an internal temperature of +68°F when the exterior ambient temperature is -40°F.
4.3.2 Summer Cooling Target: The cooling systems must maintain an internal temperature of +74°F when the exterior ambient temperature is +100°F.
4.3.3 Baseline HVAC Configuration: The Contractor shall provide an integrated environmental control system capable of conditioning all trailer operational zones (Habitation, Command, and Garage areas). Baseline acceptable configurations are:
A multi-zone mini-split heat pump system with auxiliary low-ambient heating (minimum 36,000 BTU total capacity), OR
A minimum of three (3) commercial-grade 15,000 BTU roof-mounted heat pump units with integrated heat strips.
4.3.4 Engineered Alternative Heating Solutions: The Government permits the proposal of alternative custom-engineered heating and thermal management systems (including commercial hydronic heating systems, multi-stage forced-air furnaces, or hybrid heat pump/fuel-fired configurations) in lieu of standard rooftop or mini-split units, provided the solution complies with Section 4.3.7.
4.3.5 Active Dehumidification: The Contractor must install a built-in, active dehumidifier capable of extracting a minimum of 30 pints of water per day to control internal moisture and condensation.
4.3.6 Particulate Air Filtration: The HVAC air return in the primary Command Zone must accept a high-efficiency HEPA filter assembly capable of capturing airborne particulates, soot, and low-level radioactive dust.
4.3.7 Extreme Climate Thermal Performance Threshold: Regardless of the equipment configuration selected, the primary heating system must reliably maintain a minimum interior ambient temperature of +68°F across all zones when the exterior ambient temperature reaches -40°F with sustained 25 mph wind conditions.
4.3.8 Alternative System Engineering Verification: Offerors proposing an engineered alternative under Section 4.3.4 must provide verifiable engineering substantiation within their technical proposal, including:
Calculated total heat loss (BTU/hr) based on proposed trailer wall, ceiling, and floor composite insulation values (R-ratings).
Manufacturer published heating capacity curves derated to -40°F ambient operation.
Fuel and electrical load profiles verifying full operational compatibility with the specified onboard 20 kW generator and 50A shore power connections.
4.3.9 Radiant Floor Heating: The forward habitation zone and bathroom must feature 110V electric radiant floor heating beneath the flooring material to maintain operator core temperatures during sub-zero deployments.
5.0 UTILITY, POWER, AND PLUMBING SYSTEMS
5.1 Onboard Generator & Fuel System
5.1.1 Primary Generator: Power must be supplied by a minimum 20 kW liquid-cooled diesel generator (Powertech or equal) mounted in a dedicated, sound-insulated exterior compartment.
5.1.2 Dual Fuel Tank System: The generator must draw fuel from an integrated dual-tank system consisting of two (2) frame-mounted 30-gallon diesel fuel tanks (totaling 60 gallons).
5.1.3 Fuel Transfer Pump: The system must include a 12V DC electric transfer pump to allow the operator to safely transfer fuel between the auxiliary reserve tank and the primary generator tank.
5.1.4 Generator Winterization Package: The generator must be equipped with an integrated 120V block heater, an oil pan heater, and a heated fuel/water separator to guarantee reliable cold starts in sub-zero ambient temperatures.
5.1.5 Continuous Runtime Performance: The generator and fuel system shall provide a minimum of 24 hours of continuous operation at a sustained 70% electrical load without refueling, under all specified environmental conditions.
5.2 Electrical Distribution & Power Storage
5.2.1 Service Distribution Panel: The electrical system must utilize a 100 Amp main service panel, configured for 120/240V single-phase power, with a minimum of 12 spaces / 24 circuits.
5.2.2 Shore Power Connection: The trailer must feature a 50A motor base power inlet with a heavy-duty 25-foot shore power cord.
5.2.3 Power Converter & Charger: Power conversion must be managed by a 100 Amp converter with an integrated multi-stage battery charger.
5.2.4 Battery Bank & Power Storage: The battery bank must feature a minimum of three (3) 12V Lithium Iron Phosphate (LiFePO ) 100Ah deep-cycle batteries, equipped with internal heating elements to support charging in freezing temperatures.
5.2.5 Solar Infrastructure Preparation: The roof must be pre-wired with dedicated solar infrastructure, including a weatherproof roof-entry plate, 10 AWG solar cabling pre-run to the battery compartment, and a pre-installed 40-amp Maximum Power Point Tracking (MPPT) charge controller.
5.2.6 Automated Energy Management System (EMS): The Contractor shall integrate an intelligent, automated Energy Management System (EMS) into the trailer’s electrical power distribution network:
5.2.6.1 Shore Power Load Monitoring & Dynamic Shedding: When
connected to an external 120/240V, 50A shore power source, the EMS must continuously monitor total electrical current draw across both power legs.
To prevent nuisance tripping of the primary 50A shore power breaker, the EMS shall automatically and dynamically shed pre-designated, non-critical circuits before total load exceeds 80% of continuous breaker capacity (40A per leg).
5.2.6.2 Automatic Circuit Restoration: When total electrical demand decreases below the safe threshold, the EMS shall automatically re-engage shed circuits in reverse order.
5.2.6.3 Generator Mode Operation: When operating under onboard 20 kW diesel generator power, the electrical distribution system must support full, simultaneous operation of all onboard systems without triggering load-shedding protocols.
5.2.6.4 EMS Load Priority Hierarchy: The Contractor shall configure electrical distribution sub-panels and EMS logic to adhere strictly to the following priority tiers:
Priority 1 (Life/Mission Critical – NEVER SHED): Command center workstations, communications/radio systems, mission equipment charging outlets, positive-pressure CBRN air filtration system, primary HVAC blowers, and interior operational/emergency lighting.
Priority 2 (Operational Comfort – STAGED SHED): Secondary HVAC heating elements/compressors, main cabin wall outlets, and vehicle battery bank charging systems.
Priority 3 (Auxiliary/Discretionary – FIRST TO SHED): Electric water heater element, galley appliances (including microwave), and exterior scene/perimeter lighting.
5.3 Water & Plumbing Systems
5.3.1 Holding Tank Capacities: Water storage must consist of a minimum of three independent holding tanks:
Fresh Water: Minimum 100 gallons.
Grey Water: Minimum 45 gallons.
Black Water: Minimum 42 gallons.
5.3.2 Inline Water Filtration: The plumbing system must feature an integrated, dual-stage inline water filtration system for shore and city water inputs.
5.3.3 Insulated Plumbing Envelope: All plumbing lines, holding tanks, and valves must run inside the heated envelope of the trailer.
5.3.4 Sub‐Zero Freeze Protection: All fresh, grey, and black water holding tanks, as well as all exterior dump valves, must be equipped with thermostatically controlled 12V heating pads to prevent freezing in ambient temperatures down to -40°F.
5.3.5 On‐Demand Water Heater: Hot water must be supplied by a high-recovery, commercial-grade tankless (on-demand) water heater.
5.3.6 Service Inlets & Hose Assembly: The trailer must feature city water and gravity fill inlets, along with an integrated sewer hose and enclosed storage carrier (minimum 10-foot hose).
5.3.7 Tow Vehicle Block Heater Port: The front exterior of the trailer must feature a weatherproof 110V receptacle wired directly to the generator panel, allowing the towing vehicle's engine block heater to be plugged directly into the trailer's generator power.
6.0 INTERIOR LAYOUT & FUNCTIONAL ZONING
6.1 General Interior Construction
To ensure operational efficiency and prevent hazardous material absorption, the interior must feature seamless fiberglass surfaces on the ceiling and walls. The interior shall be physically partitioned into four distinct functional zones separated by insulated walls and space-saving pocket doors.
6.2 Zone 1: Front Habitation & Wet Zone (Approx. 12 Feet)
6.2.1 Bunk Sleeping Berths: The Contractor must permanently mount a minimum of three (3) foldable double bunk beds (totaling 6 sleeping berths) with heavy-duty aluminum frames in the nose section. Mattresses must consist of high-density memory foam (minimum 6-inch thickness), and each berth must feature a blackout privacy curtain, individual USB-A/USB-C charging ports, and dedicated LED reading lighting.
6.2.2 GSA Class 6 High‐Security Safe: The Contractor must construct a reinforced, built-in wall space and permanently bolt a GSA Class 6 high-security safe (meeting Federal Specification AA-F-358, weighing approximately 150 lbs., dimensions 16"W x 19"D x 12.5"H) within this secure zone for the storage of sensitive items and documentation. No commercial equivalents are authorized.
6.2.3 Laundry Unit: The wet zone must feature a pre-plumbed and wired combination washer/dryer unit (Splendide 2100XC or equal).
6.3 Zone 2: Mid-Ship Command & Culinary Zone (Approx. 22 Feet)
6.3.1 Operations Slide‐Out: The zone must feature a 244-inch flush-floor slide-out compartment on the curbside. The slide-out must contain fixed lower workstation desks with overhead cabinets, electrical and data hookups, integrated TV mounts, and an interior wall surface finished for dry-erase whiteboard use.
6.3.2 Kitchenette & Appliances: The culinary area must include lockable cabinets fabricated from minimum 16-gauge heavy-duty commercial aluminum with positive-locking latches, laminate countertops, a farmhouse-style deep basin sink, a 10.0 cubic foot refrigerator (AC/DC compatible), a 1.1 cubic foot
| electric convection microwave oven, and an electric cooktop. Liquid | Propane | |||||||
| Gas | (LPG/propane) | ranges | or | gas‐powered | appliances | standard | in | |
| commercial | RVs | are | strictly | prohibited | to | maintain | explosive | safety. |
6.3.3 Workstation Media Panels: The slide-out workstation area must feature two (2) flush-mounted, pre-wired HDMI/USB media input panels positioned adjacent to the Smart TV mounts to allow direct connection of external monitors and data feeds.
6.4 Zone 3: Full Bathroom Package & Decontamination Routing
6.4.1 Decon / Wet‐Entry Routing: To prevent radioactive, chemical, or explosive contamination from entering clean living and command areas, the bathroom must be positioned immediately adjacent to the rear tactical garage with a direct access door. Surfaces must be easily decontaminated and include solid PVC trim, seamless fiberglass walls, black coin rubber flooring, aluminum framed cabinets, and black HDPE shelves. The layout must support a closed-loop flow: personnel entering from the "dirty" garage step directly into the bathroom, shed contaminated outer gear, and access the shower without crossing Zone 1 or Zone 2.
6.4.2 Enclosed Shower: A fully enclosed rectangular fiberglass shower (minimum 36" x 36") with a secure shower door.
6.4.3 Sanitation Toilet: A foot-pedal RV-style toilet plumbed to the black water holding tank.
6.4.4 Bathroom Vanity: A lower laminate cabinet with an integrated hand wash sink, faucet, vanity mirror, and dedicated linen storage.
6.4.5 Ventilation & Heating: A 12V roof-mounted exhaust vent with weather guard over the shower, supplemented by a 1,000 W electric wall heater.
6.4.6 CBRN & Positive Pressure System:
6.4.6.1 Protection Scope: Zone 1 (Habitation) and Zone 2 (Command) must be protected by a permanently installed, self-contained CBRN filtration and positive pressure system designed to prevent ingress of airborne radiological, chemical, and biological contaminants.
6.4.6.2 System Components: System must consist of a high-static-pressure blower, sealed filter housing, dedicated intake/exhaust ports, and a combination filter cartridge.
6.4.6.3 Filtration Efficiency: Filter cartridge must be a combination HEPA/activated carbon unit providing minimum 99.97% efficiency for 0.3-micron particulates and incorporating a carbon bed for gas-phase contaminant absorption.
6.4.6.4 Positive Pressure Threshold: The system must deliver a minimum of 120 CFM of filtered air to sealed crew zones. When active, it must generate and maintain a continuous internal positive pressure of +0.20 inches water column (W.C.) above external atmospheric pressure.
6.4.6.5 System Control & Power Integration: The system must be controlled by a dedicated switch on the main interior control panel and hardwired to a mission-critical Priority 1 circuit (never shed by the EMS).
6.4.6.6 On‐Site Pressure Verification: As a key performance parameter, the system's ability to achieve and maintain +0.20 inches W.C. must be demonstrated and verified with a digital manometer during final acceptance at Minot AFB.
6.4.7 Exterior Gross Decontamination Station: The exterior of the trailer (curbside near the garage ramp) must feature a weatherproof, heated exterior shower/washdown port connected to the onboard water heater and freshwater pump for gross decontamination of bomb suits, robots, and UTVs prior to interior entry.
6.5 Zone 4: Rear Tactical Garage & Auxiliary Living Zone (Approx. 14 Feet)
6.5.1 Garage Dimensions & Ramp Door: A minimum 14-foot clear garage space featuring a heavy-duty drop-down rear ramp door rated for a minimum 4,000 lbs. rolling vehicle load. Includes 12V 55W LED loading lights and a remote-controlled 12-foot LED incident lighting mast.
6.5.2 Floor Substructure, Surface, & Drainage: The garage floor structure shall be engineered to withstand high-impact, concentrated wheel point loads from an outfitted tactical Utility Task Vehicle (UTV) weighing up to 3,500 lbs. and heavy tracked robotic platforms:
Substructure Spacing: Floor crossmembers spaced on a maximum of 12-inch centers using heavy-wall structural box tubing to eliminate deck deflection, sag, or oil-canning under concentrated loads.
Textured Industrial Polyurea Surface: Finished floor shall consist of minimum 3/4-inch exterior/marine-grade plywood or composite subfloor, completely encapsulated with a seamless, high-pressure applied commercial-grade industrial polyurea/polyurethane elastomeric coating (minimum 80 mils / 0.080-inch thickness).
Watertight Bathtub Basin: Coating must continuously roll upside and front walls to a minimum height of 6 inches to establish a sealed washdown basin.
Embedded Non‐Skid Texture: Floor must incorporate aggressive non-skid texturing for positive traction when wet with water, snow melt, mud, or petroleum fluids.
Decontamination Drains: Minimum of two (2) flush-mounted, sealable floor drains with removable sediment traps. Bare metal grates or open floor penetrations are strictly prohibited.
6.5.3 Cargo Securing System: Recessed aluminum E-track flush-mounted into the garage floor (minimum 40 linear feet) to secure vehicles and heavy gear.
6.5.4 Auxiliary Sleeping Sofa: One (1) heavy-duty rollover sleeper sofa mounted to the curbside wall that folds flat during vehicle transport and converts into an extra bed once the garage is cleared.
6.5.5 Wardrobe Storage: A minimum 48-inch-wide wardrobe cabinet with built-in clothes rod and shelf for cold-weather outerwear near the entry point.
6.5.6 EOD Suit Drying Locker: A heavy-duty reinforced locker/rack capable of supporting up to four (4) 100-lb. EOD bomb suits, featuring dedicated forced-air ducting from the HVAC system for rapid drying in cold weather.
6.5.7 Garage Recovery Winch: A minimum 4,500 lb. 12V DC electric winch with synthetic rope, floor-mounted at the forward bulkhead of the tactical garage to assist in loading disabled UTVs, heavy robots, or mission cargo.
6.5.8 Dedicated Hydration and Cooling Systems: Independent of the primary kitchenette food refrigerator:
6.5.8.1 Slide‐Out Hydration Fridge/Freezer: One (1) high-capacity (minimum 75–100 liter) compressor-driven chest-style refrigerator/freezer (Dometic, ARB, or approved ruggedized equivalent). Must be dual-voltage (12V DC / 110V AC), hardwired to the power system, and mounted on a heavy-duty, lockable, full-extension slide tray located in the rear garage or an exterior weatherproof compartment.
6.5.8.2 High‐Output Commercial Ice Maker: One (1) built-in, marine or commercial-grade automatic ice maker installed in the forward kitchenette, plumbed to the freshwater system with dedicated inline filtration, producing a minimum of 20 to 25 lbs. of ice per day.
7.0 TACTICAL EOD MISSION SUPPORT EQUIPMENT
7.1 SCBA Storage Brackets
The Contractor must supply and securely mount a minimum of six (6) Self- Contained Breathing Apparatus (SCBA) brackets, split evenly (3 per side) and anchored to the structural garage framing inside the rear ramp door.
7.2 Ventilated Bomb Suit Lockers
The Contractor must provide dedicated, ventilated storage lockers for heavy bomb suits equipped with integrated heavy-duty hangers and 12V forced-air ventilation fans to air out suits post-operation.
7.3 EOD Robot Charging Station
The garage workspace must include at least two (2) dedicated, high-amperage 120V AC charging receptacles located adjacent to heavy-duty floor tie-down anchors, specifically wired to secure and charge tactical unmanned ground vehicles (UGVs/Robots).
7.4 Onboard Pneumatic System
The Contractor must install a dedicated onboard pneumatic air compressor with plumbed outlets in the garage area to support pneumatic tools and vehicle tire inflation.
7.5 Command, Control, & Communications (C3) Structural
Infrastructure
To allow the trailer to function as an autonomous tactical command post, the Contractor must pre-install the structural and cabling infrastructure below. All
| active | IT | equipment | (routers, | switches, | cellular | boosters, | and | active | satellite | terminals) |
| are | Government‐Furnished | / | Government‐Installed | (GF/GI): |
7.5.1 Antenna Mast Mounts & SATCOM Roof Preparation:
Mast Mounts: Rigid external mounting brackets and weather-tight RF/coaxial cable feed-through ports installed on the exterior wall to support tactical field antennas.
SATCOM Mounting Plate: Reinforced, walkable roof plate (minimum 3' x 3') positioned above the C2 slide-out for future satellite communications and radio antenna arrays.
Conduit Passthrough: Minimum 2-inch diameter weatherproof conduit pass-through from the roof plate directly into the interior C2 server rack, maintaining envelope thermal integrity.
7.5.2 IT Server Enclosure & UPS: A minimum 12U wall-mounted, vibration-isolated IT rack enclosure with an integrated 1500VA Uninterruptible Power Supply (UPS) for network routers and switchgear.
7.5.3 External Media Input Panel: A weatherproof exterior HDMI/Ethernet panel allowing external camera feeds or video downlinks to connect directly into interior workstation monitors.
7.5.4 Exterior Command and Control (C2) Briefing Station: An integrated, weatherproof exterior C2 briefing station mounted on the curbside (passenger side) comprising:
Weatherproof Tech Enclosure: Lockable, environmentally sealed compartment housing a minimum 40-inch LED ruggedized/outdoor monitor, pre-wired (HDMI/DisplayPort) to the interior server rack.
Exterior Power & Connectivity: Minimum two (2) 110V/120V GFCI weatherproof receptacles, four (4) USB charging ports, and two (2) weatherproof RJ-45 Cat6 data ports linked to the secure network switch.
Fold‐Down Work Surface: Lockable, heavy-duty fold-down aluminum desk beneath the tech enclosure rated for a minimum 100 lb. working load.
Shelter & Illumination: Flush-mounted exterior LED scene lighting and a 25-foot motorized commercial awning with remote to protect personnel and electronics during external briefings.
7.6 Tactical Lighting Systems
7.6.1 Exterior Scene Lights: Two (2) commercial-grade, non-recessed 12V LED exterior scene lights (minimum 14" x 2.5") on the utility side. Each fixture must deliver a minimum of 3,000 lumens, carry an IP67 waterproof rating, and operate via interior switches.
7.6.2 Rear Loading Lights: One (1) pair of commercial-grade exterior LED loading lights (minimum 1,500 lumens each) mounted above the rear ramp door to illuminate loading operations.
7.6.3 Awning Lighting: Integrated continuous LED strip lighting along the curbside motorized awning providing a minimum of 1,000 lumens.
8.0 CONTRACT ADMINISTRATION & DELIVERABLES
8.1 Quality Assurance, Latent Defects, & Acceptance Criteria
8.1.1 Contractor Responsibility: In accordance with Federal Acquisition Regulation (FAR) 52.212-4, the Contractor is solely responsible for product quality and the rigorous execution of all engineering and manufacturing processes.
8.1.2 Design Approval Submittal (Deliverable A001): The Contractor must submit complete 3D CAD drawings and layouts for Government approval prior to fabrication:
Format: High-resolution, multi-page Portable Document Format (PDF).
Drawing Scope: Standard 2D orthographic projections (top, front, rear, curbside, street-side) with critical dimensions; 360-degree 3D rendered isometric views; and detailed floor plans/cross-sections detailing all four zones and major subsystems.
Liability: Government review is strictly for compliance validation and does not relieve the Contractor of liability for structural or system performance.
8.1.3 Final Acceptance Inspection (Deliverable A002): The Government will inspect and accept the completed trailer at Minot AFB, ND, based upon a Contractor-furnished Certificate of Conformance (CoC) confirming full compliance with SOW specifications.
8.1.4 Latent Defects Protection: In accordance with RFO 52.212-4(o), acceptance of the CoC does not waive the Government’s right to seek non-cost repair, replacement, or equitable price reduction under latent defect provisions should thermal or HVAC systems fail to maintain outcome thresholds (+68°F heating at -40°F cold; +74°F cooling at 100°F heat) during field operations. The Contractor's warranty obligations must comply with RFO 52.212-4(o).
8.1.5 Testing Methodology: Physical "cold room" environmental chamber testing is excluded to mitigate commercial overhead. Thermal compliance must be proven via static engineering calculations and heat load modeling during design submittals.
8.2 Deliverables Schedule & Performance Standards
Deliverable
ID
Deliverable Title
SOW
Ref
Delivery Format
Service / Delivery Location
Due Date
A001 3D CAD Design Drawings & System Schematics
2.1.2 & 8.1.2
High-resolution electronic PDF files via email or secure transfer link.
Delivered electronically to the 5
CES/CED
requirements owner.
Within thirty (30) calendar days of contract award.
A002 EOD Nuclear Response Trailer Delivery
2.2.1 & 8.1.3
One (1) fully assembled, compliant mobile trailer.
Physical delivery to 5
CES/CED
facility, Building 897, Minot AFB, ND 58705.
Within two hundred and forty (240) calendar days of contract award. Early delivery authorized at no additional cost.
A003 Technical Documentation & Manuals
2.3.1– 2.3.4
Three (3) durable bound print manuals and one (1) searchable
PDF.
Electronic copy via secure email/link;
physical manuals delivered with trailer to Building 897, Minot
AFB.
Electronic manuals due concurrently with or prior to delivery;
print manuals due upon final physical delivery.
A004 Chassis Structural & Deflection Report (FEA)
3.1.1.4 Certified
engineering calculation
/ FEA
report proving load deflection limits.
Delivered electronically to 5 CES/CED requirements owner.
Within thirty (30) calendar days of contract award / prior to frame fabrication.
Government review within 15 calendar days.
9.0 WARRANTY REQUIREMENTS
9.1 Standard Commercial Warranty Framework
In accordance with FAR 12.205 and FAR 52.212-4(o), the Contractor must provide its standard commercial warranty as offered to the public. To satisfy Government operational safety and reliability needs for this nuclear response asset, coverage must satisfy the following minimum terms:
9.1.1 Structural Warranty: Minimum three (3) year limited warranty covering chassis frame rails, crossmembers, wall studs, roof bows, and primary structural weldments.
9.1.2 Builder‐Manufactured Components: Minimum three (3) year limited warranty covering all custom components fabricated and installed by the trailer builder.
9.1.3 Electrical Wiring & Distribution: Minimum one (1) year limited warranty covering electrical distribution panels, wiring harness integrity, fixtures, and power storage systems.
9.1.4 Pass‐Through Equipment Warranties: In accordance with commercial practice, OEM warranties for third-party commercial components (including diesel generator, HVAC units, tankless water heater, leveling jacks, and tires) must be assigned directly to the Government upon final acceptance.