J-18 Hardware Schedule A-131.pdf

PDF 446 KB Posted

Attached to
B2619 Dorm Construction Renovations
Solicitation number
FA448425R0003
Issued by

About this file

This is an architectural floor plan drawing (Sheet A-131) showing the third floor layout of Area A in Building 2619, a dormitory renovation project at McGuire AFB in Lakehurst, New Jersey. The drawing details bedroom layouts, bathroom locations, and a lounge/cafe area, with specific room numbers and dimensions indicated. The plan shows approximately 12 bedrooms, shared bathroom facilities, a corridor (room 316), and mechanical elements including fan coil units with concealed piping systems.

The drawing includes standard architectural notations, a scale of 1/8"=1'-0", and detailed notes regarding fire extinguisher placement, partition requirements, and mechanical specifications. It is part of a 100% Final Design Submittal dated March 22, 2024, prepared under contract FA8903-21-D0004, solicitation PTFL22-1019. The drawing was created by C. Coppola and checked by C. Frances for BSC-JV.

View the file

Other files

Show all 26

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A-201 F1

A-201 K1

A

B

C

D

E

F

1 3 4 5 6 7 8 9 102

JC

BEDROOM

BEDROOM

BEDROOM

BEDROOM

BEDROOM

BEDROOM

BEDROOM

BEDROOM

ST-A

STAIR A

BEDROOM

BEDROOM

BEDROOM

BEDROOM

CL

CORRIDOR

330N

LOUNGE /

CAFE AREA

A

/ A -1

A

/ A

-1

304A

BATHROOM

A-401

A7

SIM

309-10A

BATHROOM

311-12A

BATHROOM

313-14A

BATHROOM

308-07A

BATHROOM

305-6A

BATHROOM

A-401

G7

SIM

A-402

H1

D2

D3-45

D1

D1 D1

D1D1

D1D1

D1 D1

D1

D1

D3-45

D3-45

D3-45

304b 302

D3-45

D3

D3D3

D3

D3

D1

+/- 13' - 4" +/- 13' - 4" +/- 13' - 4" +/- 13' - 4" +/- 13' - 4" +/- 13' - 4" +/- 11' - 1" +/- 8' - 9" +/- 11' - 9 1/2"

9.01

4A1.4 4A1.4

4A1.6

4A1.6

4A1.6

4A1.6

4A1.6

4A1.4

4A0.4

4A1.4

5'

5'

10.05 10.05

23.02

23.03

23.02

23.03

23.02

23.03

23.02

23.03

23.02

23.03

23.02

23.03

23.03

23.03

23.02

23.03

23.02

23.03

23.02

23.03

23.02

23.03

23.02

23.03

23.02

23.03

A B

PLAN NORTH

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

M C

G U

IR

E

A F

B L A

K E

H U

R S

T N

E W

J E

R S

E Y

M C

G U

IR

E

A F

B

N E

W J

E R

S E

Y R

E N

O V

A T

IO

N

O F

D O

R M

IT

O

R Y

B U

IL

D

IN

G

F A

-2

-D

P T

F L

-1

KEYPLAN

GRAPHIC SCALE NORTH ARROW

U S

A

IR

F O

R C

E C

IV

IL

E N

G

IN

E E

R C

E N

T E

R

A u to d e s k D o c s

/1 J

B M

D L D o rm

R e n o

B -B

/P

T F

L -B

-A

.r v t

/2

/2

:0

:4

P

M

A-131

R

D F

L O

O R

P L A

N

A R

E A

A

C C

O P

P O

L A

C C

O P

P O

L A

B S

C -J

V

C F

R A

N C

E S

M

A R

C H

F

IN

A L D

E S

IG

N

S U

B M

IT

T

A L

SCALE:

4' - 0" 8' - 0" 16' - 0"

1/8" = 1' - 0"

NOTES - FLOOR PLANS

1 REFER TO SHEET A-001 FOR ARCHITECTURAL GENERAL NOTES, &

ANNOTATION LEGEND

2 REFER TO A-600 SERIES FOR PARTITION TYPES

3 REFER TO ENLARGED PLANS AND INTERIOR ELEVATIONS FOR ADDITIONAL

INFORMATION

4 REFER TO MECHANICAL, ELECTRICAL, AND TELECOMM SHEETS FOR

EQUIPMENT LOCATIONS AND REQUIREMENTS.

5 ALL DIMENSIONS SHOWN ARE TO FACE OF WALL (LEFT TO RIGHT, BOTTOM TO

TOP)- TYPICAL UNLESS NOTED OTHERWISE

6 ALL DOORS TO BE INSTALLED 4" FROM HINGE SIDE OF WALL - TYPICAL

UNLESS NOTED OR DIMENSIONED OTHERWISE

7 DIMENSIONS MARKED AS "CLEAR" DICTATES THE CLEAR DIMENSION FROM

FINISH TO FINISH

8 WHERE FIRE RATED PARTITIONS INTERSECT WITH LESSER RATED

PARTITIONS OR NON-RATED PARTITIONS, THE HIGHER RATED PARTITION IS

TO CONTINUE THROUGH THE INTERSECTION TO MAINTAIN THE HIGHER

RATING

9 FIRE EXTINGUISHERS SHALL BE PROVIDED AND LOCATED IN ACCORDANCE

WITH NFPA 10. THE MAXIMUM TRAVEL DISTANCE TO THE NEAREST FIRE

EXTINGUISHER FROM ANY POINT IN THE BUILDING SHALL NOT EXCEED 75

FEET.

SHEET KEYNOTES

9.01 EXISTING EXTERIOR STAIR TO REMAIN.

10.05 RECESSED FIRE EXTINGUISHER CABINETS. PATCH WALL TO

ACCOMODATE NEW CABINET.

23.02 FAN COIL UNIT, SEE MECHANICAL

23.03 CONCEAL PIPES TO FAN COIL UNIT USING REMOVABLE METAL FALSE

BACK PLENUM WTIH ACCESS PANEL. HEIGHT TO MATCH TOP OF FCU UNIT.

1/8" = 1'-0"A1

3RD FLOOR PLAN - AREA A

3.22.2023

Casey.Coppola Line

Casey.Coppola Arc

Casey.Coppola Text Box

File details come from the government source that posted it. Updated .