Asbestos Report Bldg. 294 (2).pdf
PDF 2 MB Posted
- Attached to
- Request for Proposal (RFP) #FA445225R0036 - 43d Air Mobility Operations Group (AMOG) Barracks Floor Repair
- Solicitation number
- FA445225R0036
About this file
This document is an Asbestos Inspection Report for Building 294, a three-story barracks located at Pope Air Force Base in North Carolina. Conducted on March 1, 2011, by Ryan Burnett (North Carolina asbestos inspector certification #12661), the survey involved collecting and analyzing multiple material samples from various building components including pipe coverings, door and window caulking, drywall, floor tiles, ceiling textures, and joint compounds.
The laboratory analysis by EMSL Analytical, Inc. using Polarized Light Microscopy (EPA Method 600/R-93/116) found no asbestos-containing materials (ACMs) in any of the 20 samples collected. The report was prepared for the Directorate of Public Works at Fort Bragg and includes detailed tables documenting the sample types, descriptions, locations, and laboratory analysis results. While no asbestos was detected, the report notes that materials not readily apparent or in concealed locations may not have been identified, and recommends further evaluation of any suspected materials discovered during future renovation work.
View the file
Other files
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Signature: Date: 3/3/2011 Chris Burnett Get The Lead Out, LLC NC Lic. #11063
Focus Asbestos Survey for Renovation of
Building 294 Pope AFB, North Carolina
Prepared by Chris Burnett, Get The Lead Out, LLC for The Directorate of Public Works, Ft. Bragg, North Carolina
Table of Contents
Asbestos Inspection Report…………………………………………………….3
List of Tables
Table 1 Asbestos Containing Materials…..…………………………………..5 Table 2 – Non Asbestos Containing Materials………………………………6 Laboratory Reports and Chain of Custody Forms.…………………………10
Appendices Appendix A Photographs………………………………………..……………18 Appendix B Certifications and Accreditations…………………...…………19
Asbestos Inspection Report
Introduction
Scope of the Investigation
This report documents the asbestos inspection and survey of the Building 294 (Barracks) located in the Pope AFB in Fayetteville, North Carolina conducted on March 1, 2011, by Ryan Burnett, inspector certification number: NC 12661.
Background
The building is a reported 16,792 SF three-story structure formerly utilized as a barracks. The building is of steel and concrete masonry constructed with an exterior brick veneer and a steel-paneled roof.
Investigation
The building was visually inspected for suspected asbestos containing materials (ACM) by a North Carolina accredited inspector. Representative interior building areas were inspected for this project. A copy of the inspector’s accreditation certificate is included in Appendix B. Bulk samples of all suspect ACM’s were collected. This report details ACM as identified (if identified) at the time of inspection only. A focused inspection was conducted for the presence of asbestos containing building materials
(ACBM).
EMSL, Inc. analyzed the bulk samples. The laboratory is accredited by the National Voluntary Laboratory Accredited Program (NVLAP Accreditation sponsored by the National Institute of Standards and Technology (NIST)). A Copy of their accreditation certificate is included in Appendix A. The samples were analyzed by the accepted method of polarized light microscopy (PLM) using EPA’s “Method for the Determination of Asbestos In Bulk Building Materials”, EPA/600/R-93/116.
Laboratory results indicate that ASBESTOS WAS NOT DETECTED.
In compliance with the AHERA regulations, material is considered an Asbestos
Containing Material (ACM) when it contains greater than one percent asbestos.
Likewise, in this report, any material containing concentrations greater than one percent asbestos will be considered “positive”. Occasionally, materials containing less than one percent asbestos, or not sampled, are assumed to be a “positive” asbestos containing material at the discretion of the inspectors. A narrative discussion of the AHERA ACM types (i.e., thermal systems insulation, miscellaneous and surfacing materials) found in the vacant residential structure is included in this report where relevant. Bulk sample information appears, estimated quantities of individual asbestos containing materials, material characterization of asbestos containing materials appears on Table 1.
Conclusions No ACMs were identified.
Recommendations Currently, based upon the results of this asbestos survey, no additional investigations are warranted.
Limitations As is the case with any asbestos inspection, materials that were not readily apparent or were located in concealed locations may not have been identified. If any material that is suspected to contain asbestos, and was not included in this report as a material identified and tested, is discovered, it should be evaluated for asbestos content before it is disturbed.
Although Polarized Light Microscopy (PLM)/Dispersion Staining (Method EPA 600/R-93/116) is the specified method for analysis of bulk material samples for asbestos under EPA Asbestos Hazard Emergency Response Act, there may have been reports that this method may not identify asbestos when fiber sizes are extremely small or if they are bound in a resinous material. EPA recommends analyzing such materials (floor tiles, mastics and asphalt roofing) using Transmission Electron Microscopy (TEM) when PLM analysis does not detect asbestos in quantities greater than 1%.
Current EPA regulations do not require this additional analysis and the decision to do so is left with the client.
This report is not intended for use as an asbestos removal specification. It is not within the scope of this work to describe all appropriate precautions, safeguards and regulations relating to asbestos.
Sole Use Statement This report is provided for the sole use of the Directorate of Public Works at Ft.
Bragg. Reliance on this report by any third parties will be at such party’s sole risk, and Get The Lead Out disclaims liability for any use of or reliance on this report by third parties. All portions of this report, including attachments and figures, are interrelated and integral to this report and should not be transmitted independent of each other.
TABLE 1 – Asbestos Containing Materials
BUILDING 294
MATERIAL CHARACTERISTICS ASSESSMENT
Sample No.
Type Description/Location % Asbestos
Yes/No/Presumed Quantity/Type
(If ACM) Friable / Non-
Friable Condition Disturbance Potential
None identified.
TABLE 2 – Non Asbestos Containing Materials
BUILDING 294
Sample No.
Type Description/Location % Asbestos
Yes/No/Presumed Quantity/Type
(If ACM) Friable / Non-
Friable Condition Disturbance Potential
1 / TSI Pipe covering (Grey/white) / Representative material NAD N/A Friable Good High
2 / MISC Door frame caulking / Representative material NAD N/A Non-Friable Good High
3 / TSI Pipe covering (white/silver) Representative material NAD N/A Friable Good High
4 / TSI Grey/silver pipe covering / Representative material NAD N/A Friable Good High
4 / TSI Grey mastic with grey pipe covering / Representative material NAD N/A Non-Friable Good High
5 / MISC 1’x1’ Floor tile / Representative material NAD N/A Non-Friable Good High
5 / MISC Yellow mastic with 1’x1’ Floor tile / Representative material NAD N/A Non-Friable Good High
Sample No.
Type Description/Location % Asbestos
Yes/No/Presumed Quantity/Type
(If ACM) Friable / Non-
Friable Condition Disturbance Potential
6 /
SURFACING
Ceiling texture / Representative material NAD N/A Friable Good High
7 / MISC
Drywall material / Representative material
NAD N/A Non-Friable Good High
7 /
SURFACING
Joint compound material with drywall / Representative material NAD N/A Non-Friable Good High
8 / MISC Door frame caulking / Representative material NAD N/A Non-Friable Good High
9 / MISC Window caulking / Representative material NAD N/A Non-Friable Good High
10 / MISC Window caulking / Representative material NAD N/A Non-Friable Good High
11 / MISC Door frame caulking /
12 / MISC
Drywall material / Representative material
NAD N/A Non-Friable Good High
Sample No.
Type Description/Location % Asbestos
Yes/No/Presumed Quantity/Type
(If ACM) Friable / Non-
Friable Condition Disturbance Potential
12 /
SURFACING
Joint compound material with drywall / Representative material NAD N/A Non-Friable Good High
12 / MISC
Drywall tape (Interior walls adhered on the drywall) / Representative material
NAD N/A Friable Good High
13 / MISC 1’x1’ Floor tile / Representative material NAD N/A Non-Friable Good High
13 / MISC Yellow mastic with 1’x1’ Floor tile / Representative material NAD N/A Non-Friable Good High
14 /
SURFACING
Ceiling texture / Representative material NAD N/A Friable Good High
15 / MISC
Drywall material / Representative material
NAD N/A Non-Friable Good High
15 /
SURFACING
Joint compound material with drywall / Representative material NAD N/A Non-Friable Good High
16 / MISC 1’x1’ Floor tile /
Sample No.
Type Description/Location % Asbestos
Yes/No/Presumed Quantity/Type
(If ACM) Friable / Non-
Friable Condition Disturbance Potential
16 / MISC Yellow mastic with 1’x1’ Floor tile / Representative material NAD N/A Non-Friable Good High
17 / MISC Tan cove base / Representative material NAD N/A Non-Friable Good High
17 / MISC Adhesive with tan cove base / Representative material NAD N/A Non-Friable Good High
18 /
SURFACING
Ceiling texture / Representative material NAD N/A Friable Good High
19 / MISC Door frame caulking / Representative material NAD N/A Non-Friable Good High
20 / TSI White/silver pipe covering / Representative material NAD N/A Friable Good High
20 / TSI White mastic with white/silver pipe covering / Representative material NAD N/A Non-Friable Good High
Laboratory Reports and
Chain of Custody Forms
Sample Description Appearance % Type
AsbestosNon-Asbestos
% Fibrous % Non-Fibrous
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy
411100628
Attn: Chris Burnett Get The Lead Out, LLC 2121 Commonwealth Avenue Suite 202 Charlotte, NC 28205
Customer PO:
Received: 03/01/11 9:30 AM
BLDG 294 POPE AFB
Customer ID: GETT78
Fax: (704) 376-3593 Phone: (704) 376-3594 Project:
EMSL Order:
EMSL Proj:
3/2/2011Analysis Date:
EMSL Analytical, Inc.
4335 Stuart Andrew Blvd, Suite 101, Charlotte, NC 28217 Phone: (704) 525-2205 Fax: (704) 525-2382 Email: charlottelab@emsl.com
411100628-0001
PIPE COVERING Gray/White None Detected
Fibrous Heterogeneous
Cellulose45% Glass10%
Non-fibrous (other)45%
411100628-0002
DOOR CAULKING Gray None Detected
Non-Fibrous Heterogeneous
Non-fibrous (other)100%
411100628-0003
PIPE COVERING White/Silver None Detected
Fibrous Heterogeneous
Cellulose55% Glass10%
Non-fibrous (other)35%
4-Wrap 411100628-0004
PIPE COVERING Gray/Silver None Detected
Fibrous Heterogeneous
Cellulose45% Glass10%
Non-fibrous (other)45%
4-Mastic 411100628-0004A
PIPE COVERING Gray None Detected
Non-Fibrous Heterogeneous
Synthetic<1% Non-fibrous (other)100%
5-Floor Tile 411100628-0005
FLOOR TILE Gray/White None Detected
Non-Fibrous Heterogeneous
Non-fibrous (other)100%
5-Mastic 411100628-0005A
FLOOR TILE Gray/Tan None Detected
Non-Fibrous Heterogeneous
Cellulose<1% Non-fibrous (other)100%
Lee Plumley, Laboratory Manager or other approved signatory
Analyst(s)
Test Report PLM-7.23.0 Printed: 3/2/2011 10:56:28 AM
EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted.
Samples analyzed by EMSL Analytical, Inc. Charlotte, NC NVLAP Lab Code 200841-0, VA 3333 00312, W V LT000325
Lee Plumley (30)
Initial report from 03/02/2011 09:24:53 mailto:charlottelab@emsl.com
% Fibrous % Non-Fibrous
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy
411100628
Attn: Chris Burnett Get The Lead Out, LLC 2121 Commonwealth Avenue Suite 202 Charlotte, NC 28205
Customer PO:
Received: 03/01/11 9:30 AM
BLDG 294 POPE AFB
Customer ID: GETT78
Fax: (704) 376-3593 Phone: (704) 376-3594 Project:
EMSL Order:
EMSL Proj:
3/2/2011Analysis Date:
EMSL Analytical, Inc.
4335 Stuart Andrew Blvd, Suite 101, Charlotte, NC 28217 Phone: (704) 525-2205 Fax: (704) 525-2382 Email: charlottelab@emsl.com
411100628-0006
CEILING
TEXTURE
Gray/Tan None Detected
Non-Fibrous Heterogeneous
Non-fibrous (other)100%
7-Drywall 411100628-0007
DRYWALL JOINT
COMPOUND
Brown/Gray None Detected
Fibrous Heterogeneous
Cellulose15% Glass2%
Non-fibrous (other)83%
7-Joint Compound 411100628-0007A
DRYWALL JOINT
COMPOUND
White None Detected
Non-Fibrous Heterogeneous
Non-fibrous (other)100%
411100628-0008
DOOR CAULKING Gray None Detected
Non-Fibrous Heterogeneous
Non-fibrous (other)100%
411100628-0009
WINDOW
CAULKING
Brown None Detected
Fibrous Heterogeneous
Cellulose2% Non-fibrous (other)98%
411100628-0010
WINDOW
CAULKING
Brown None Detected
Fibrous Heterogeneous
Cellulose2% Non-fibrous (other)98%
411100628-0011
DOOR CAULKING Gray None Detected
Non-Fibrous Heterogeneous
Non-fibrous (other)100%
Lee Plumley, Laboratory Manager or other approved signatory
Analyst(s)
Test Report PLM-7.23.0 Printed: 3/2/2011 10:56:28 AM
EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted.
Samples analyzed by EMSL Analytical, Inc. Charlotte, NC NVLAP Lab Code 200841-0, VA 3333 00312, W V LT000325
Lee Plumley (30)
% Fibrous % Non-Fibrous
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy
411100628
Attn: Chris Burnett Get The Lead Out, LLC 2121 Commonwealth Avenue Suite 202 Charlotte, NC 28205
Customer PO:
Received: 03/01/11 9:30 AM
BLDG 294 POPE AFB
Customer ID: GETT78
Fax: (704) 376-3593 Phone: (704) 376-3594 Project:
EMSL Order:
EMSL Proj:
3/2/2011Analysis Date:
EMSL Analytical, Inc.
4335 Stuart Andrew Blvd, Suite 101, Charlotte, NC 28217 Phone: (704) 525-2205 Fax: (704) 525-2382 Email: charlottelab@emsl.com
12-Drywall 411100628-0012
DRYWALL JOINT
COMPOUND
Gray None Detected
Fibrous Heterogeneous
Cellulose2% Glass2%
Non-fibrous (other)96%
12-Joint Compound 411100628-0012A
DRYWALL JOINT
COMPOUND
White None Detected
Non-Fibrous Heterogeneous
Non-fibrous (other)100%
12-Tape 411100628-0012B
DRYWALL JOINT
COMPOUND
Tan None Detected
Fibrous Heterogeneous
Cellulose99% Non-fibrous (other)1%
13-Floor Tile 411100628-0013
FLOOR TILE Gray/White None Detected
Non-Fibrous Heterogeneous
Non-fibrous (other)100%
13-Mastic 411100628-0013A
FLOOR TILE Tan None Detected
Non-Fibrous Heterogeneous
Cellulose1% Non-fibrous (other)99%
411100628-0014
CEILING
TEXTURE
Tan/White None Detected
Non-Fibrous Heterogeneous
Non-fibrous (other)100%
15-Drywall 411100628-0015
DRYWALL JOINT
COMPOUND
Brown/Gray None Detected
Fibrous Heterogeneous
Cellulose15% Non-fibrous (other)85%
Lee Plumley, Laboratory Manager or other approved signatory
Analyst(s)
Test Report PLM-7.23.0 Printed: 3/2/2011 10:56:28 AM
EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted.
Samples analyzed by EMSL Analytical, Inc. Charlotte, NC NVLAP Lab Code 200841-0, VA 3333 00312, W V LT000325
Lee Plumley (30)
% Fibrous % Non-Fibrous
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy
411100628
Attn: Chris Burnett Get The Lead Out, LLC 2121 Commonwealth Avenue Suite 202 Charlotte, NC 28205
Customer PO:
Received: 03/01/11 9:30 AM
BLDG 294 POPE AFB
Customer ID: GETT78
Fax: (704) 376-3593 Phone: (704) 376-3594 Project:
EMSL Order:
EMSL Proj:
3/2/2011Analysis Date:
EMSL Analytical, Inc.
4335 Stuart Andrew Blvd, Suite 101, Charlotte, NC 28217 Phone: (704) 525-2205 Fax: (704) 525-2382 Email: charlottelab@emsl.com
15-Joint Compound 411100628-0015A
DRYWALL JOINT
COMPOUND
White None Detected
Non-Fibrous Heterogeneous
Non-fibrous (other)100%
16-Floor Tile 411100628-0016
TILE FLOOR
BROWN MASTIC
Gray/White None Detected
Non-Fibrous Heterogeneous
Non-fibrous (other)100%
16-Mastic 411100628-0016A
TILE FLOOR
BROWN MASTIC
Tan None Detected
Non-Fibrous Heterogeneous
Non-fibrous (other)100%
17-Cove Base 411100628-0017
COVE MOLDING Tan None Detected
Non-Fibrous Heterogeneous
Non-fibrous (other)100%
17-Mastic 411100628-0017A
COVE MOLDING Tan None Detected
Non-Fibrous Heterogeneous
Non-fibrous (other)100%
411100628-0018
CEILING
TEXTURE
Tan/White None Detected
Non-Fibrous Heterogeneous
Non-fibrous (other)100%
411100628-0019
DOOR CAULKING Gray None Detected
Non-Fibrous Heterogeneous
Non-fibrous (other)100%
Lee Plumley, Laboratory Manager or other approved signatory
Analyst(s)
Test Report PLM-7.23.0 Printed: 3/2/2011 10:56:28 AM
EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted.
Samples analyzed by EMSL Analytical, Inc. Charlotte, NC NVLAP Lab Code 200841-0, VA 3333 00312, W V LT000325
Lee Plumley (30)
% Fibrous % Non-Fibrous
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy
411100628
Attn: Chris Burnett Get The Lead Out, LLC 2121 Commonwealth Avenue Suite 202 Charlotte, NC 28205
Customer PO:
Received: 03/01/11 9:30 AM
BLDG 294 POPE AFB
Customer ID: GETT78
Fax: (704) 376-3593 Phone: (704) 376-3594 Project:
EMSL Order:
EMSL Proj:
3/2/2011Analysis Date:
EMSL Analytical, Inc.
4335 Stuart Andrew Blvd, Suite 101, Charlotte, NC 28217 Phone: (704) 525-2205 Fax: (704) 525-2382 Email: charlottelab@emsl.com
20-Wrap 411100628-0020
PIPE COVER White/Silver None Detected
Fibrous Heterogeneous
Cellulose45% Glass10%
Non-fibrous (other)45%
20-Mastic 411100628-0020A
PIPE COVER White None Detected
Non-Fibrous Heterogeneous
Wollastonite2% Cellulose1%
Non-fibrous (other)97%
Lee Plumley, Laboratory Manager or other approved signatory
Analyst(s)
THIS IS THE LAST PAGE OF THE REPORT.Test Report PLM-7.23.0 Printed: 3/2/2011 10:56:28 AM
EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted.
Samples analyzed by EMSL Analytical, Inc. Charlotte, NC NVLAP Lab Code 200841-0, VA 3333 00312, W V LT000325
Lee Plumley (30)
Appendix A Photographs
No photographs are included for no samples were identified as ACMs in this asbestos survey.
Appendix B Certifications and Accreditations
| Focus Asbestos Survey for Renovation of |
| Building 294 |
| Pope AFB, North Carolina |
| Table of Contents |
| List of Tables |
| Appendices |
| Asbestos Inspection Report |
| Introduction |
| Scope of the Investigation |
| Background |
| Investigation |
| Conclusions |
| Recommendations |
| Limitations |
| Sole Use Statement |