Asbestos Report-Bldg. 292 (2).pdf

PDF 2 MB Posted

Attached to
Request for Proposal (RFP) #FA445225R0036 - 43d Air Mobility Operations Group (AMOG) Barracks Floor Repair
Solicitation number
FA445225R0036
Issued by

About this file

This document is an Asbestos Inspection Report for Building 292, a three-story barracks structure located at Pope Air Force Base in Fayetteville, North Carolina. The survey was conducted on March 1, 2011, by Ryan Burnett, a North Carolina-accredited asbestos inspector (certification number NC 12661). Laboratory analysis by EMSL Analytical, Inc. using Polarized Light Microscopy (EPA Method 600/R-93/116) tested 18 material samples from various building components including floor tiles, drywall, joint compound, ceiling texture, cove base, pipe coverings, caulking, and other materials.

The inspection found no Asbestos Containing Materials (ACMs) in the building, with all samples testing negative for asbestos. The building is described as having steel and concrete masonry construction with an exterior brick veneer and steel-paneled roof. The report includes detailed laboratory test results showing sample compositions, which predominantly contained non-fibrous materials like cellulose and non-fibrous (other) components. The survey was prepared for the Directorate of Public Works at Ft. Bragg and is intended solely for their use, with a recommendation that no additional investigations are warranted based on the findings.

View the file

Other files

Show all 17

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Signature: Date: 3/3/2011 Chris Burnett Get The Lead Out, LLC NC Lic. #11063

Focus Asbestos Survey for Renovation of

Building 292 Pope AFB, North Carolina

Prepared by Chris Burnett, Get The Lead Out, LLC for The Directorate of Public Works, Ft. Bragg, North Carolina

Table of Contents

Asbestos Inspection Report…………………………………………………….3

List of Tables

Table 1 Asbestos Containing Materials…..…………………………………..5 Table 2 – Non Asbestos Containing Materials………………………………6 Laboratory Reports and Chain of Custody Forms.…………………………10

Appendices Appendix A Photographs………………………………………..……………18 Appendix B Certifications and Accreditations…………………...…………19

Asbestos Inspection Report

Introduction

Scope of the Investigation

This report documents the asbestos inspection and survey of the Building 292 (Barracks) located in the Pope AFB in Fayetteville, North Carolina conducted on March 1, 2011, by Ryan Burnett, inspector certification number: NC 12661.

Background

The building is a reported 35,790 SF three-story structure formerly utilized as a barracks. The building is of steel and concrete masonry construction with an exterior brick veneer and a steel-paneled roof.

Investigation

The building was visually inspected for suspected asbestos containing materials (ACM) by a North Carolina accredited inspector. Representative interior building areas were inspected for this project.

A copy of the inspector’s accreditation certificate is included in Appendix B. Bulk samples of all suspect ACM’s were collected. This report details ACM as identified (if identified) at the time of inspection only. A focused inspection was conducted for the presence of asbestos containing building materials (ACBM).

EMSL, Inc. analyzed the bulk samples. The laboratory is accredited by the National Voluntary Laboratory Accredited Program (NVLAP Accreditation sponsored by the National Institute of Standards and Technology (NIST)). A Copy of their accreditation certificate is included in Appendix A. The samples were analyzed by the accepted method of polarized light microscopy (PLM) using EPA’s “Method for the Determination of Asbestos In Bulk Building Materials”, EPA/600/R-93/116.

Laboratory results indicate that ASBESTOS WAS NOT DETECTED.

In compliance with the AHERA regulations, material is considered an Asbestos

Containing Material (ACM) when it contains greater than one percent asbestos.

Likewise, in this report, any material containing concentrations greater than one percent asbestos will be considered “positive”. Occasionally, materials containing less than one percent asbestos, or not sampled, are assumed to be a “positive” asbestos containing material at the discretion of the inspectors. A narrative discussion of the AHERA ACM types (i.e., thermal systems insulation, miscellaneous and surfacing materials) found in the vacant residential structure is included in this report where relevant. Bulk sample information appears, estimated quantities of individual asbestos containing materials, material characterization of asbestos containing materials appears on Table 1.

Conclusions No ACMs were identified.

Recommendations Currently, based upon the results of this asbestos survey, no additional investigations are warranted.

Limitations As is the case with any asbestos inspection, materials that were not readily apparent or were located in concealed locations may not have been identified. If any material that is suspected to contain asbestos, and was not included in this report as a material identified and tested, is discovered, it should be evaluated for asbestos content before it is disturbed.

Although Polarized Light Microscopy (PLM)/Dispersion Staining (Method EPA 600/R-93/116) is the specified method for analysis of bulk material samples for asbestos under EPA Asbestos Hazard Emergency Response Act, there may have been reports that this method may not identify asbestos when fiber sizes are extremely small or if they are bound in a resinous material. EPA recommends analyzing such materials (floor tiles, mastics and asphalt roofing) using Transmission Electron Microscopy (TEM) when PLM analysis does not detect asbestos in quantities greater than 1%.

Current EPA regulations do not require this additional analysis and the decision to do so is left with the client.

This report is not intended for use as an asbestos removal specification. It is not within the scope of this work to describe all appropriate precautions, safeguards and regulations relating to asbestos.

Sole Use Statement This report is provided for the sole use of the Directorate of Public Works at Ft.

Bragg. Reliance on this report by any third parties will be at such party’s sole risk, and Get The Lead Out disclaims liability for any use of or reliance on this report by third parties. All portions of this report, including attachments and figures, are interrelated and integral to this report and should not be transmitted independent of each other.

TABLE 1 – Asbestos Containing Materials

BUILDING 292

MATERIAL CHARACTERISTICS ASSESSMENT

Sample No.

Type Description/Location % Asbestos

Yes/No/Presumed Quantity/Type

(If ACM) Friable / Non-

Friable Condition Disturbance Potential

None identified.

TABLE 2 – Non Asbestos Containing Materials

BUILDING 292

Sample No.

Type Description/Location % Asbestos

Yes/No/Presumed Quantity/Type

(If ACM) Friable / Non-

Friable Condition Disturbance Potential

1 / MISC 1’x1’ Floor tile / Representative material NAD N/A Non-Friable Good High

1 / MISC Yellow mastic with 1’x1’ Floor tile / Representative material NAD N/A Non-Friable Good High

2 / MISC

Drywall material / Representative material

NAD N/A Non-Friable Good High

2 /

SURFACING

Joint compound material with drywall / Representative material NAD N/A Non-Friable Good High

3 /

SURFACING

Ceiling texture / Representative material NAD N/A Friable Good High

4 / MISC Tan cove base / Representative material NAD N/A Non-Friable Good High

4 / MISC Adhesive with tan cove base /

Sample No.

Type Description/Location % Asbestos

Yes/No/Presumed Quantity/Type

(If ACM) Friable / Non-

Friable Condition Disturbance Potential

5 / TSI Pipe covering (white/silver/yellow fiberglass) / Representative material NAD N/A Friable Good High

6 / MISC Door frame caulking / Representative material NAD N/A Non-Friable Good High

7 / TSI Grey/silver pipe covering / Representative material NAD N/A Friable Good High

7 / TSI Grey mastic with grey/silver pipe covering / Representative material NAD N/A Non-Friable Good High

8 / MISC Grey/silver pipe covering / Representative material NAD N/A Friable Good High

8 / MISC Grey mastic with grey/silver pipe covering / Representative material NAD N/A Non-Friable Good High

9 / MISC Window caulking /

10 / MISC

Drywall material / Representative material

NAD N/A Non-Friable Good High

Sample No.

Type Description/Location % Asbestos

Yes/No/Presumed Quantity/Type

(If ACM) Friable / Non-

Friable Condition Disturbance Potential

10 /

SURFACING

Joint compound material with drywall / Representative material NAD N/A Non-Friable Good High

11 /

SURFACING

Ceiling texture / Representative material NAD N/A Friable Good High

12 / MISC Tan cove base / Representative material NAD N/A Non-Friable Good High

12 / MISC Adhesive with tan cove base / Representative material NAD N/A Non-Friable Good High

13 / MISC Door frame caulking / Representative material NAD N/A Non-Friable Good High

14 / MISC 1’x1’ Floor tile / See Sample Location Map NAD N/A Non-Friable Good High

14 / MISC Yellow mastic with 1’x1’ Floor tile / See Sample Location Map NAD N/A Non-Friable Good High

15 /

SURFACING

Ceiling texture / Representative material NAD N/A Friable Good High

Sample No.

Type Description/Location % Asbestos

Yes/No/Presumed Quantity/Type

(If ACM) Friable / Non-

Friable Condition Disturbance Potential

16 / MISC 1’x1’ Floor tile / See Sample Location Map NAD N/A Non-Friable Good High

16 / MISC Yellow mastic with 1’x1’ Floor tile / See Sample Location Map NAD N/A Non-Friable Good High

17 / MISC

Drywall material / Representative material

NAD N/A Non-Friable Good High

17 /

SURFACING

Joint compound material with drywall / Representative material NAD N/A Non-Friable Good High

18 / MISC Door frame caulking /

Laboratory Reports and

Chain of Custody Forms

Sample Description Appearance % Type

AsbestosNon-Asbestos

% Fibrous % Non-Fibrous

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy

411100627

Attn: Chris Burnett Get The Lead Out, LLC 2121 Commonwealth Avenue Suite 202 Charlotte, NC 28205

Customer PO:

Received: 03/01/11 9:30 AM

Bld 292 Pope AFB

Customer ID: GETT78

Fax: (704) 376-3593 Phone: (704) 376-3594 Project:

EMSL Order:

EMSL Proj:

3/2/2011Analysis Date:

EMSL Analytical, Inc.

4335 Stuart Andrew Blvd, Suite 101, Charlotte, NC 28217 Phone: (704) 525-2205 Fax: (704) 525-2382 Email: charlottelab@emsl.com

1-Floor Tile 411100627-0001

KITCHEN WHITE

TILE, BROWN

MASTIC

Gray/White None Detected

Non-Fibrous Heterogeneous

Non-fibrous (other)100%

1-Mastic 411100627-0001A

KITCHEN WHITE

TILE, BROWN

MASTIC

Tan None Detected

Non-Fibrous Heterogeneous

Non-fibrous (other)100%

2-Drywall 411100627-0002

DRYWALL JOINT

COMPOUND

Brown/Gray None Detected

Fibrous Heterogeneous

Cellulose15% Non-fibrous (other)85%

2-Joint Compound 411100627-0002A

DRYWALL JOINT

COMPOUND

White None Detected

Non-Fibrous Heterogeneous

Non-fibrous (other)100%

411100627-0003

CEILING

TEXTURE

White None Detected

Non-Fibrous Heterogeneous

Non-fibrous (other)100%

4-Cove Base 411100627-0004

COVE MOLDING Tan None Detected

Non-Fibrous Heterogeneous

Non-fibrous (other)100%

4-Mastic 411100627-0004A

COVE MOLDING Tan None Detected

Non-Fibrous Heterogeneous

Non-fibrous (other)100%

Lee Plumley, Laboratory Manager or other approved signatory

Analyst(s)

Test Report PLM-7.23.0 Printed: 3/2/2011 10:55:25 AM

EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted.

Samples analyzed by EMSL Analytical, Inc. Charlotte, NC NVLAP Lab Code 200841-0, VA 3333 00312, W V LT000325

Lee Plumley (28)

Initial report from 03/02/2011 09:22:51 mailto:charlottelab@emsl.com

% Fibrous % Non-Fibrous

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy

411100627

Attn: Chris Burnett Get The Lead Out, LLC 2121 Commonwealth Avenue Suite 202 Charlotte, NC 28205

Customer PO:

Received: 03/01/11 9:30 AM

Bld 292 Pope AFB

Customer ID: GETT78

Fax: (704) 376-3593 Phone: (704) 376-3594 Project:

EMSL Order:

EMSL Proj:

3/2/2011Analysis Date:

EMSL Analytical, Inc.

4335 Stuart Andrew Blvd, Suite 101, Charlotte, NC 28217 Phone: (704) 525-2205 Fax: (704) 525-2382 Email: charlottelab@emsl.com

411100627-0005

PIPING COVER White/Silver/Yello w

None Detected

Fibrous Heterogeneous

Glass10% Cellulose40%

Non-fibrous (other)50%

411100627-0006

DOOR CAULKING Gray None Detected

Non-Fibrous Heterogeneous

Non-fibrous (other)100%

7-Wrap 411100627-0007

PIPE COVER-

HVAC

Gray/Silver None Detected

Fibrous Heterogeneous

Cellulose45% Glass10%

Non-fibrous (other)45%

7-Mastic 411100627-0007A

PIPE COVER-

HVAC

Gray None Detected

Non-Fibrous Heterogeneous

Synthetic<1% Non-fibrous (other)100%

8-Wrap 411100627-0008

PIPE COVER Gray/Silver None Detected

Fibrous Heterogeneous

Cellulose45% Glass10%

Non-fibrous (other)45%

8-Mastic 411100627-0008A

PIPE COVER Gray None Detected

Non-Fibrous Heterogeneous

Synthetic<1% Non-fibrous (other)100%

411100627-0009

WINDOW

CAULKING

Brown None Detected

Fibrous Heterogeneous

Cellulose2% Non-fibrous (other)98%

Lee Plumley, Laboratory Manager or other approved signatory

Analyst(s)

Test Report PLM-7.23.0 Printed: 3/2/2011 10:55:25 AM

EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted.

Samples analyzed by EMSL Analytical, Inc. Charlotte, NC NVLAP Lab Code 200841-0, VA 3333 00312, W V LT000325

Lee Plumley (28)

% Fibrous % Non-Fibrous

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy

411100627

Attn: Chris Burnett Get The Lead Out, LLC 2121 Commonwealth Avenue Suite 202 Charlotte, NC 28205

Customer PO:

Received: 03/01/11 9:30 AM

Bld 292 Pope AFB

Customer ID: GETT78

Fax: (704) 376-3593 Phone: (704) 376-3594 Project:

EMSL Order:

EMSL Proj:

3/2/2011Analysis Date:

EMSL Analytical, Inc.

4335 Stuart Andrew Blvd, Suite 101, Charlotte, NC 28217 Phone: (704) 525-2205 Fax: (704) 525-2382 Email: charlottelab@emsl.com

10-Drywall 411100627-0010

DRYWALL JOINT

COMPOUND

Brown/Gray None Detected

Fibrous Heterogeneous

Cellulose15% Non-fibrous (other)85%

10-Joint Compound 411100627-0010A

DRYWALL JOINT

COMPOUND

White None Detected

Non-Fibrous Heterogeneous

Non-fibrous (other)100%

411100627-0011

CEILING

TEXTURE

White None Detected

Non-Fibrous Heterogeneous

Non-fibrous (other)100%

12-Cove Base 411100627-0012

COVE MOLDING Tan None Detected

Non-Fibrous Heterogeneous

Non-fibrous (other)100%

12-Mastic 411100627-0012A

COVE MOLDING Tan None Detected

Non-Fibrous Heterogeneous

Non-fibrous (other)100%

411100627-0013

DOOR CAULKING Gray None Detected

Non-Fibrous Heterogeneous

Non-fibrous (other)100%

14-Floor Tile 411100627-0014

TILE CLOSET

BROWN MASTIC

Gray/White None Detected

Non-Fibrous Heterogeneous

Non-fibrous (other)100%

Lee Plumley, Laboratory Manager or other approved signatory

Analyst(s)

Test Report PLM-7.23.0 Printed: 3/2/2011 10:55:25 AM

EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted.

Samples analyzed by EMSL Analytical, Inc. Charlotte, NC NVLAP Lab Code 200841-0, VA 3333 00312, W V LT000325

Lee Plumley (28)

% Fibrous % Non-Fibrous

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy

411100627

Attn: Chris Burnett Get The Lead Out, LLC 2121 Commonwealth Avenue Suite 202 Charlotte, NC 28205

Customer PO:

Received: 03/01/11 9:30 AM

Bld 292 Pope AFB

Customer ID: GETT78

Fax: (704) 376-3593 Phone: (704) 376-3594 Project:

EMSL Order:

EMSL Proj:

3/2/2011Analysis Date:

EMSL Analytical, Inc.

4335 Stuart Andrew Blvd, Suite 101, Charlotte, NC 28217 Phone: (704) 525-2205 Fax: (704) 525-2382 Email: charlottelab@emsl.com

14-Mastic 411100627-0014A

TILE CLOSET

BROWN MASTIC

Tan None Detected

Non-Fibrous Heterogeneous

Cellulose<1% Non-fibrous (other)100%

411100627-0015

CEILING

TEXTURE

White None Detected

Non-Fibrous Heterogeneous

Cellulose<1% Non-fibrous (other)100%

16-Floor Tile 411100627-0016

FLOOR TILE Gray/White None Detected

Non-Fibrous Heterogeneous

Non-fibrous (other)100%

16-Mastic 411100627-0016A

FLOOR TILE Tan None Detected

Non-Fibrous Heterogeneous

Cellulose<1% Non-fibrous (other)100%

17-Drywall 411100627-0017

DRYWALL JOINT

COMPOUND

Brown/Gray None Detected

Fibrous Heterogeneous

Cellulose15% Non-fibrous (other)85%

17-Joint Compound 411100627-0017A

DRYWALL JOINT

COMPOUND

White None Detected

Non-Fibrous Heterogeneous

Non-fibrous (other)100%

411100627-0018

DOOR CAULKING Brown None Detected

Non-Fibrous Heterogeneous

Non-fibrous (other)100%

Lee Plumley, Laboratory Manager or other approved signatory

Analyst(s)

THIS IS THE LAST PAGE OF THE REPORT.Test Report PLM-7.23.0 Printed: 3/2/2011 10:55:25 AM

EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted.

Samples analyzed by EMSL Analytical, Inc. Charlotte, NC NVLAP Lab Code 200841-0, VA 3333 00312, W V LT000325

Lee Plumley (28)

Appendix A Photographs

No photographs are included for no samples were identified as ACMs in this asbestos survey.

Appendix B Certifications and Accreditations

Focus Asbestos Survey for Renovation of
Building 292
Pope AFB, North Carolina
Table of Contents
List of Tables
Appendices
Asbestos Inspection Report
Introduction
Scope of the Investigation
Background
Investigation
Conclusions
Recommendations
Limitations
Sole Use Statement
Appendix A
Photographs
Appendix B
Certifications and Accreditations

File details come from the government source that posted it. Updated .