Attachment 9 - Manual For AFE Vacuum Pump.pdf

PDF 4 MB Posted

Attached to
60 OSS Air System Maintenance
Solicitation number
FA442726Q1106
Issued by

About this file

This document is an Operation and Maintenance Manual for an Elmo Rietschle 2BH1900-1AK26 Vacuum Pump supplied by McKenna Engineering & Equipment Co., Inc. to Stateline Solutions LLC at Travis Air Force Base, with purchase order number SSLLC0025 dated August 29, 2025. The manual covers a side-channel blower system designed for industrial applications involving vacuum and pressure generation for non-flammable, non-aggressive, non-toxic, and non-explosive gases or gas-air mixtures. The equipment specifications indicate the G-BH1 and G-BH9 series pumps operate continuously at ambient temperatures between -15°C and +40°C, with installation altitude limits of 1,000 meters above sea level. The vacuum pump features standard mufflers on inlet and discharge connections, operates at 50 or 60 Hz depending on the model variant, and includes motor protection rated IP55 with insulation class F and UL/CSA approvals.

The manual provides comprehensive operational guidance across eleven sections covering safety protocols, installation requirements (horizontal or vertical positioning options), electrical connection specifications for three-phase AC motors with NEMA Premium efficiency ratings, piping connection procedures, commissioning steps including direction-of-rotation verification, and detailed troubleshooting tables addressing common faults such as motor failure to start, insufficient pressure generation, and abnormal noise. Critical safety warnings emphasize hazards from rotating impellers, vacuum and pressure exposure, hot surfaces reaching 160°C, and electrical dangers requiring trained personnel for all work. McKenna Engineering provides field service, repair center capabilities with 10,000 square feet of facilities, and engineering support including 3D modeling, ASME pressure vessel certification, hydrostatic testing to 3,000 PSIG, and complete turn-key packaged system integration for vacuum, compression, and bulk solids handling applications.

View the file

Other files

Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

EQUIPMENT SALES ENGINEERING DESIGN SYSTEM INTEGRATION FABRICATION

EQUIPMENT SERVICE & REPAIR CONSTRUCTION & INSTALLATION

Stateline Solutions

Travis AFB

Date:

PO#:

August 29, 2025

SSLLC0025

Operation and Maintenance Manual

Equipment: Elmo Rietschle 2BH1900-1AK26 Vacuum Pump

Engineer:

Customer:

Supplier:

Jason Fetherman

Stateline Solutions LLC

28141 Edinburgh Dr.

Romulus, MI 48174

Contact: Samuel Anderson

McKenna Engineering

13720 Cimmaron Avenue

Gardena, CA 90249

Contact: Jason Fetherman

Table of Contents

• Outline Drawing

• Pump Performance Graphs

• Pump Data Sheet

• 2BH1900-1AK26 Operation and Maintenance Manual

•Section 1: Safety

•Section 2: Intended Use

•Section 3: Technical Data

•Section 4: Transport and Handling

•Section 5: Installation

•Section 6: Commissioning

•Section 7: Operation

•Section 8: Shut-Down and Longer Standstills

•Section 9: Servicing

•Section 10: Disposal

•Section 11: Explosion-Protected Design

• Line Card

Outline Drawing

Pump Performance Graphs

G-BH 1 N

Side channel blower with NEMA Premium motor

S uc tio n ca pa ci ty

V cf m

Vacuum Total pressure difference p [inch H2O] Pressure

P ow er c on su m pt io n

P at p um p sh af t [ hp

Vacuum Total pressure difference p [inch H2O] Pressure

T em pe ra tu re r is e T of c on ve ye d ai r

[F

Vacuum Total pressure difference p [inch H2O] Pressure

Gardner Denver Deutschland GmbH Technical data sheet - Edition 01/2019 US

The performance curves are based on air at a temperature of 59 F and an atmospheric pressure of 29.92 inch Hg with a tolerance of ± 10 %. The total Suction capacity relates to inlet conditions. Pressure capacity relates to atmospheric conditions. For other conditions please contact Elmo Rietschle.

Pressure operation (scfm)Vacuum operation (acfm)

Data sheet 2BH1 900

Every G-BH blower can be used either for vacuum or pressure in continuous operation over the total performance curve range. The standard motors have a protection category of IP 55 and insulation class F. These blowers are UL and CSA approved.

Performance curves

3 4

0 50 100 150 200 250

3 4

050100150200

0,0

5,0

10,0

15,0

20,0

25,0

30,0

050100150200

3 4

050100150200

3 4

0 50 100 150 200 250

0 50 100 150 200 250

50 Hz 60 Hz

50 Hz 60 Hz

Pump Data Sheet

463 2BH1900-1AQ27 60 440-480 31,4 26,7 -153 153 79 IE3

60 460 31,4

50 380-420 / 660-725 31,7 / 18,3 23,2

79 NP

74 IE3

50 475-525 25,4 23,2 -141 165

60 550-600 25,1 26,7 -153 153

463 2BH1900-1AK26 60 220-240 / 380-420 62,8 / 31,4 26,7 -153 153 79 IE3

60 230 / 460 62,8 / 31,4 26,7 -153

79 NP

50 220-240 / 380-420 54,9 / 31,7 23,2 -141 165 74 IE3

153 79 NP

50 190-210 74 IE3

463 2BH1900-1AK21 60 190-210 / 380-420 72,2 / 36,1 26,7 -153 153 79 IE3

60 200 72,2

63,1 23,2 -141 165

26,7 -153 153

200 V YY / 230 V / 400 VY 230 V YY / 460 VY

190-210 VYY220-240 V / 380-420VY 220-240 VYY / 440-480VY

475-525 V Y 550-600 V Y

380-420 / 23,3 74

Voltage range

All G-BH blowers conform to the 2006/42/EC (machinery) and 2006/95/EC (low voltage) directives and the EN 60034 norm “Rotating electrical machines”.

Service factor (SF) and motor efficiency according NEMA MG1-12.

Voltage tolerances for three phase motors are +/-10%.

The frequency tolerance is +/- 2 % maximum.

1)

550-600 V

2BH1…-1. □ . □

200 V 200 V YY / 230 V / 400 VY

190-210 V 190-210 VYY220-240 V / 380-420VY

50 Hz 60Hz 60 Hz

NP

/ 15,3 79 NP 56

76,0 / 38,0 32,9 -153 185 79 IE3

Motor for alternate voltages

Efficiency

3~

475-525 V

79 NP -153 185

IE3

/ 440-480 / 23,0 79 IE3

/ 460 /

19,4 -108 104

23,0 79 NP

74 IE3

397 60 190-210 / 380-420 35,2 / 17,6 13,3 -60 56 79 IE3

Your Ultimate Source for Vacuum and Pressure www.elmorietschle.com

Industriestraße 26 97616 Bad Neustadt - Germany

1800 Gardner Expressway

Quincy, IL 62305 Tel.: +49 9771 6888-0 Tel: 866-249-2275

Fax: +49 9771 6888-4000 Fax: 217-221-8780 www.elmorietschle.com

Changes in particular of the quoted performance curve, data and weights may occur without prior notice. The data given does not constitute an obligation from our side to deliver as shown.

Elmo Rietschle is a brand of Gardner Denver Gardner Denver Deutschland GmbH Gardner Denver, Inc.

7Q

Q 3

• K 6

Q 5

• K 1

4) The motors according to NEMA MG1-12. NP=NEMA Premium; NEMA Premium includes IE3.

3~ 50/60 Hz, IP55, Insulation material class F, UL 1450 (certificate number E225239)

74 IE3

397 2BH1900-1AQ03

-141 165

26,7 -153 153

74 IE3

489 2BH1900-1AQ33

79 NP

In case of variable frequency drive operation the standard motor insulation system is suitable for VFD input voltages up to 500 V.

2) Relief valves available for limiting differential pressure.

3) Surface sound pressure levels are according to EN ISO 3744, measured with an equivalent unit at a distance of 1 m. The pump is throttled to an average suction pressure, with piping connected, but no relief valves fitted, tolerance ±3 dB (A).

74 IE3

463 2BH1900-1AQ23

79 NP

-145 201

60 550-600

NP

74 IE3

441 2BH1900-1AQ13

79 NP

60 230 76,0

66,3 28,6 -145/ 380-420 / 38,3 74 IE3

489 60 220-240 / 440-480

/ 460 / 38,0

50 220-240

19,4 -108 104

2BH1900-1AK16

60 230 46,0

40,3 16,9 -116 50 220-240

441 60 220-240 46,0

60 230 30,6

26,8 11,5 -76/ 380-420 / 15,5 74 IE3

56 60 220-240 30,6 13,3 -60 79 IE3

/ 460

50 220-240

3~ 50/60 Hz, IP55, Insulation material class F, UL 1450 (certificate number E225239)

397/ 440-480 / 15,3

13,3 -60

60 200 87,4

-145 201

60 190-210 / 380-420 4

50 190-210

60 200 52,8

50 190-210

32,9

441 60 190-210 / 380-420

79 NP

74 IE3

48987,4

/ 26,4 19,4 -108 104 79 IE3

76,2 28,6

19,4 -108 104

/ 43,7 32,9 -153 185 79 IE3

50 190-210

Current Power Vacuum Pressure

Hz V A hp inch H2O

60 200 35,2

-76 72 30,8

13,3 -60 56 sound press.

level

Efficiency class

Weight approx.

dB(A) lbs

Selection and ordering data Type

No.

Fre-quency Rated

Max. differential pressure

Order No.

Voltage

32,9 -153

3~ 50/60 Hz, IP55, Insulation material class F, UL 1450 (certificate number E225239)

2BH1900-1AK01

46,4 16,9

79 NP

52,8

13,3 -60 56

11,5

-116 112

2BH1900-1AK11

2BH1900-1AK31

2BH1900-1AK06

74 IE3

2BH1900-1AK36

18,4 19,4 -108 104

50 475-525 12,4 11,5 -76 72

60 550-600 12,2

30,4 32,9 -153 185

50 475-525 18,6 16,9 -116 112

60 550-600

50 475-525 30,6 28,6

3~ 50/60 Hz, IP55, Insulation material class F, UL 1450 (certificate number E225239)

50 380-420 / 660-725 15,5 / 8,9 11,5 -76 72 74 IE3

397 2BH1900-1AQ07 60 440-480 15,3 79 IE3

60 460 15,3 13,3 -60 56 79 NP

23,3 / 13,4 16,9 -116 112

19,4 -108 104

13,3 -60 56

/ 660-725 74 IE3

441 2BH1900-1AQ17 60 440-480 23,0 19,4 -108 104 79 IE3

60 460 23,0

32,9 -153

79 NP

50 380-420 / 660-725 38,3 / 22,1 28,6 -145 201 74 IE3

185 79 NP

50 380-420

400 V / 690 V Y 460 V

489 2BH1900-1AQ37 60 440-480 38,0 32,9 -153 185 79 IE3

60 460 38,0

1)

2)

3) 4)

4)

Jason Fetherman Rectangle

2BH1900-1AK26 Operation and Maintenance Manual

G-Serie

G-Series

Seitenkanal

Side Channel

Edition: 09.2011 · 610.44434.40.000 Original operating instructions · English

Operating instructions G-BH1, G-BH9

2BH1 1

2BH1 2

2BH1 3

2BH1 4

2BH1 5

2BH1 6

2BH1 8

2BH1 9

2BH9 23

Contents

© 2011 Gardner Denver Deutschland GmbH · Industriestraße 26 · 97616 Bad Neustadt · Germany

Replication, distribution and / or editing of this document and the use and distribution of its content is prohibited unless explicitly permitted. Violation obligates compensation for damages.

All rights reserved in case of the issue of a patent, utility patent or design patent.

Contents

1 Safety

1.1 Definitions

1.1.1 Safety alert symbol

1.1.2 Signal words

1.2 General safety precautions

1.3 Residual risks

2 Intended Use 3 Technical Data

3.1 Mechanical data

3.2 Electrical data

3.3 Operating conditions

4 Transport and Handling 5 Installation

5.1 Installation

5.2 Electrical connection (motor)

5.3 Connecting pipes/hoses (vacuum pump/compressor)

5.3.1 Inlet connection

5.3.2 Discharge connection

5.3.3 Procedure when connecting pipes/hoses

6 Commissioning

6.1 Preparation

6.2 Start-up and shut-down

7 Operation 8 Shut-Down and Longer Standstills

8.1 Preparing for shut-down or longer standstill

8.2 Storage conditions

9 Servicing

9.1 Emptying/Rinsing/Cleaning

9.2 Repairs/troubleshooting

9.3 Service/After-sales service

10 Disposal 11 Explosion-Protected Design EU declaration of conformity Statement on health safety and on the protection of the environment

Fig. 1: Design of gas-ring vacuum pump/compressor

1 Vacuum pump/compressor housing

2 Vacuum pump/compressor cover 3 Inlet connection with muffler 4 Discharge connection with muffler 5 Base 6 Arrow indicating delivery direction 7 Arrow indicating direction of rotation 8 Drive motor 9 Fan guard (over external fan) 10 Terminal box

Section 1: Safety

Safety

© Gardner Denver Deutschland GmbH 3 / 32 610.44434.40.000

1 Safety

1.1 Definitions

To point out dangers and important information, the following signal words and symbols are used in these operating instructions:

1.1.1 Safety alert symbol

The safety alert symbol is located in the safety precautions in the highlighted heading field on the left next to the signal word (DANGER, WARNING, CAUTION).

Safety precautions with a safety alert symbol indicate a danger of injuries.

Be sure to follow these safety precautions to protect against injuries or death!

Safety precautions without a safety alert symbol indicate a danger of damage.

1.1.2 Signal words

DANGER

WARNING

CAUTION

NOTICE

NOTE

The signal words are located in the safety precautions in the highlighted heading field.

They follow a certain hierarchy and indicate (in conjunction with the safety alert symbol, see Chapter 1.1.1) the seriousness of the danger and the type of warning.

See the following explanations:

Danger of injuries.

Indicates an imminently hazardous situation, that will result in death or serious injury if the corresponding measures are not taken.

Indicates a potentially hazardous situation, that could result in death or serious injury if the

CAUTION

Indicates a potentially hazardous situation, that may result in minor or moderate injury if the

Danger of damage.

Indicates a potentially hazardous situation that may result in property damage if the

NOTICE

Indicates a possible disadvantage, i.e.

undesirable conditions or consequences can occur if the corresponding measures are not taken.

NOTE

Indicates a possible advantage if the corresponding measures are taken; tip.

1.2 General safety precautions

Improper use of the unit can result in serious or even fatal injuries!

These operating instructions must have been read completely and understood before beginning any work with or at the pump-motor unit, must be strictly observed, must be available at the operating location of the pump-motor unit.

Improper use of the unit can result in serious or even fatal injuries!

Only operate the pump-motor unit for the purposes indicated under "Intended Use"!

with the fluids indicated under 'Intended Use'!

with the values indicated under 'Technical Data'!

or even fatal injuries!

All work on and with the pump-motor unit (transport, installation, operation, shut-down, maintenance, disposal) may only be carried out by trained, reliable expert personnel!

610.44434.40.000 4 / 32 © Gardner Denver Deutschland GmbH

When working on the unit, there is a danger of injury, e.g. in the form of cuts/cutting off, crushing and burns!

During all work on and with the pump-motor unit (transport, installation, operation, shut-down, maintenance, disposal) wear personal safety equipment (safety helmet, protective gloves, safety shoes)!

Hair and clothing can be pulled into the unit or caught and wound up moving parts!

Do not wear long, loose hair or wide, loose clothes! Use a hair net!

Electrical danger!

Work on electrical installations may be carried out by trained and authorized electricians only!

Before beginning work on the unit or system, the following measures must be carried out:

Deenergize.

Secure against being switched on again.

Determine whether deenergized.

Ground and short-circuit.

Cover or block off adjacent energized parts.

Do not open the motor terminal box until absence of electricity has been ensured!

Danger due to vacuum and gauge pressure:

sudden escape of fluids (skin and eye injuries), sudden drawing in of hair and clothing!

Danger due to escaping fluid: Burns!

Use mounting elements, connections, lines, fittings and containers with sufficient freedom from leaks and strength for the pressures which occur.

Check the mounting elements, connections, lines, fittings and containers for strength, leaks and firm seating at regular intervals!

Danger from rotating parts (external fan, impeller, shaft):

Cutting/cutting off of extremities, Grasping/winding up of hair and clothing!

Danger due to vacuum and gauge pressure:

sudden escape of fluids (skin and eye injuries), sudden drawing in of hair and clothing!

Danger due to escaping fluid: Burns!

Start-up and operation only under the following conditions:

The pump-motor unit must be completely assembled. When doing so, pay particular attention to the following components:

– the vacuum pump/compressor cover,

– the muffler on inlet and discharge connections,

– the fan guard.

The pipes/hoses must be connected to inlet and discharge connections.

Inlet and discharge connections and the connected pipes/hoses may not be closed, clogged or soiled.

Check the mounting elements, connections of the pipe/hose connections, lines, fittings and containers for strength, leaks and firm seating at regular intervals.

Danger from rotating parts (external fan, impeller, shaft):

Cutting/cutting off of extremities, Grasping/winding up of hair and clothing!

Danger due to vacuum and gauge pressure:

sudden escape of fluids (skin and eye injuries), sudden drawing in of hair and clothing!

Danger due to escaping fluid: Burns!

Before beginning work on the pump-motor unit, take the following measures:

Shut down pump-motor unit and secure against being switched on again.

Attach a sign on the system controller and on the control elements for the pump-motor unit:

"DANGER! Maintenance work on vacuum pump/compressor! Do not switch on!"

Wait for pump-motor unit to come to a complete stop. Observe run-on time!

Allow pump-motor unit to cool!

Shut-off lines. Release pressure.

Make sure that no vacuum or gauge pressure is present in the lines/tanks to be opened.

Make sure that no fluids can escape.

© Gardner Denver Deutschland GmbH 5 / 32 610.44434.40.000

Danger from rotating impeller:

Cutting/cutting of off extremities!

The rotating impeller is accessible with the inlet and discharge connections open!

Do not reach into the unit through open connections!

Do not insert objects into the unit through the openings!

Cutting/cutting of off extremities!

The rotating impeller is accessible with the inlet and discharge connections open!

With free entry and exit of gases, i.e. with direct intake out of or direct feeding into the atmosphere without piping, the following therefore applies:

Provide the inlet and discharge connections of the pump-motor unit either with additional mufflers or with additional piping of a sufficient length to prevent access to the impeller!

Danger of burns from hot surfaces of the pump-motor unit and from hot fluids!

High temperatures of up to approx. 160°C [320°F] can occur on the surface of the pump-motor unit.

Cover the pump-motor unit with a suitable touch protection (e.g. perforated plate cover or wire cover). Do not touch during operation!

Allow to cool after shut-down!

1.3 Residual risks

Danger zone:

Hot surface up to approx. 160°C [320°F].

Hazard:

Possible burns.

Protective measures:

Cover the pump-motor unit with a suitable touch protection (e.g. perforated plate cover or wire cover).

Danger zone:

Fan guard

Hazard:

Long, loose hair can be drawn into external fan through fan guard grate, even with fan guard mounted!

Protective measures:

Wear hair net!

Missing or defective muffler inlet or discharge connection.

Hazard:

Possible serious hearing damage due to emitted noise.

Protective measures:

Have missing or defective mufflers replaced.

Conduct a noise measurement in the system after installing the pump-motor unit. The following measures can be taken from 85 dB(A) and must be taken from 90 dB(A):

Mark noise area with a warning sign.

Wear hearing protection.

Environment of pump-motor unit.

Hazard:

Possible serious hearing damage due to emitted noise.

Protective measures:

Conduct a noise measurement in the system during operation after installing the pump-motor unit.

The following measures can be taken from 85 dB(A) and must be taken from 90 dB(A):

Mark noise area with a warning sign.

Wear hearing protection.

With free entry and exit of gases, i.e. with direct intake out of or direct feeding into the atmosphere without piping, attach an additional muffler.

Section 2: Intended Use

Intended Use

610.44434.40.000 6 / 32 © Gardner Denver Deutschland GmbH

2 Intended Use

This operating manual is intended for side channel compressors of the G-BH1 and G-BH9 series, types 2BH1 1

2BH1 2 2BH1 3 2BH1 4 2BH1 5 2BH1 6

2BH1 8 2BH1 9 2BH9 23,

contains instructions bearing on transport and handling, installation, commissioning, operation, shut-down, storage, servicing and disposal of the G-BH1,G-BH9, must be completely read and understood by all operating and servicing personnel before beginning to work with or on the G-BH1, G-BH9, must be strictly observed, must be available at the site of operation of the G-BH1, G-BH9.

About the operating and servicing personnel of the G-BH1, G-BH9

These persons must be trained and authorized for the work to be carried out.

Work on electrical installations may be carried out by trained and authorized electricians only.

The G-BH1,G-BH9 are pump-motor units for generating vacuum or gauge pressure;

are used to extract, pump and compress the following gases:

– Air,

– Non-flammable, non-aggressive, non-toxic and non-explosive gases or gas-air mixtures.

– With differing gases/gas-air mixtures, inquire with the Service Department.

are equipped with one of the following kind of drive motors:

– 3-phase AC drive motor with a standard or explosion-protected design

– Single-phase AC drive motor

These operating instructions apply only to pump-motor units with a standard design.

For an explosion-protected design (EEx e II), see the separate operating instructions.

are intended for industrial applications, are designed for continuous operation.

With increased switch-on frequency (6x per hour with equal pauses and operating times) or with increased gas inflow and ambient temperature, the excess temperature limit of the coil and the bearing can be exceeded.

Consult the manufacturer when using under such conditions.

When operating the G-BH1, G-BH9 the limits listed in Chapter 3, "Technical Data", Pg. 7 ff.

must always be complied with.

Foreseeable Misuse

It is prohibited to use the G-BH1, G-BH9 in applications other than industrial applications unless the necessary protection is provided on the system, e.g. guards suitable for children's fingers;

to use the device in rooms in which explosive gases can occur if the G-BH1, G-BH9 is not expressly intended for this purpose;

to extract, to deliver and to compress explosive, flammable, corrosive or toxic fluids, unless the G-BH1, G-BH9 is specifically designed for this purpose;

to operate the G-BH1 with values other than those specified in Chapter 3, "Technical Data", Pg. 7 ff.

Any unauthorized modifications of the G-BH1, G-BH9 are prohibited for safety reasons.

The operator is only permitted to perform the maintenance and service work described in these operating instructions.

Maintenance and servicing work which goes beyond this may only be carried out by companies which have been authorised by the manufacturer (ask the service department for details).

Section 3: Technical Data

Technical Data

© Gardner Denver Deutschland GmbH 7 / 32 610.44434.40.000

3 Technical Data

3.1 Mechanical data

Weight

Single-impeller design

Weight

Type [kg] approx.

[lbs] approx.

2BH1100-7..0. 9 20

2BH1200-7..0. 9 20

2BH1300-7..0. 9 20

2BH1300-7..1. 10 22

2BH1300-7..2. 11 24

2BH1330-7..0. 10 22

2BH1330-7..1. 11 24

2BH1330-7..2. 12 26

2BH1400-7..0. 13 29

2BH1400-7..1. 16 35

2BH1400-7..2. 17 37

2BH1430-7..0. 14 31

2BH1430-7..1. 17 37

2BH1430-7..2. 18 40

2BH1500-7..0. 20 44

2BH1500-7..1. 22 49

2BH1500-7..2. 23 51

2BH1500-7..3. 25 55

2BH1530-7..0. 21 46

2BH1530-7..1. 23 51

2BH1530-7..2. 24 53

2BH1530-7..3. 26 57

2BH1600-7..0. 27 60

2BH1600-7..1. 30 66

2BH1600-7..2. 36 79

2BH1600-7..3. 40 88

2BH1600-7..6. 32 71

2BH1600-7..7. 39 86

2BH1630-7..0. 29 64

2BH1630-7..1. 32 71

2BH1630-7..2. 37 82

2BH1630-7..3. 43 95

2BH1630-7..6. 34 75

2BH1630-7..7. 40 88

Single-impeller design

Weight

Type [kg] approx.

[lbs] approx.

2BH180.-7..0. 117 258

2BH180.-7..1. 126 278

2BH180.-7..2. 132 291

2BH183.-7..0. 120 265

2BH183.-7..1. 129 284

2BH183.-7..2. 135 298

2BH190.-7..0. 179 395

2BH190.-7..1. 198 437

2BH190.-7..3. 210 463

2BH193.-7..0. 179 395

2BH193.-7..1. 198 437

2BH193.-7..3. 209 463

2BH923..-…P 167 368

2BH923..-…Q 145 320

2BH923..-…H 151 333

Two-impeller design

Weight

Type [kg] approx.

[lbs] approx.

2BH1310-7..2. 15 33

2BH1410-7..3. 25 55

2BH1410-7..4. 27 60

2BH1510-7..4. 40 88

2BH1510-7..5. 44 97

2BH1610-7..1. 43 95

2BH1610-7..2. 48 106

2BH1610-7..3. 54 119

2BH1610-7..4. 66 146

2BH1610-7..5. 73 161

2BH1610-7..7. 50 110

2BH1610-7..8. 62 137

2BH1640-7..3. 54 119

2BH1640-7..4. 69 152

2BH1640-7..5. 75 165

2BH1640-7..8. 62 137

2BH181.-7..1. 171 377

2BH181.-7..2. 177 390

610.44434.40.000 8 / 32 © Gardner Denver Deutschland GmbH

Weight

Type [kg] approx.

[lbs] approx.

2BH181.-7..3. 203 448

2BH181.-7..4. 215 474

2BH184.-7..2. 177 390

2BH184.-7..3. 203 448

2BH191.-7..1. 274 604

2BH191.-7..2. 288 635

2BH191.-7..3. 299 659

2BH191.-7..4. 309 681

2BH1940-7B.2. 275 606

2BH1940-7B.3. 314 692

2BH1940-7B.4. 324 714

2BH1943-7..2. 330 728

2BH1943-7..3. 339 747

2BH1943-7..4. 349 769

Minimum distances

Minimum distance to fan guard (for sucking in cooling air):

Type [mm] [inches]

2BH1 1.. - 2BH1 4 34 1.34

2BH1 5.. - 2BH1 9 53 2.09

2BH923… 52 2.05

Minimum distance to face of vacuum pump/compressor cover:

Type [mm] [inches]

2BH1 1.. - 2BH1 5 20 0.79

2BH1 6.. 30 1.18

2BH1 8.. - 2BH1 9 40 1.57

2BH923.. 52 2.05

Noise level

Measuring-surface sound-pressure level as per EN ISO 3744, measured at a distance of 1 m [3.28 ft] at an operating point of approximately 2/3 of the permissible total pressure difference with the lines connected without a vacuum or pressure relief valve, tolerance 3 dB (A).

Single-impeller design

Type 1-m measuring-surface sound pressure level

L [dB (A)]

50 Hz approx.

60 Hz approx.

2BH1100-7..0. 52 55

2BH1200-7..0. 57 61

2BH1300-7..0. 53 56

2BH1300-7..1. 53 56

2BH1300-7..2. 53 56

2BH1330-7..0. 53 56

2BH1330-7..1. 53 56

2BH1330-7..2. 53 56

2BH1400-7..0. 63 64

2BH1400-7..1. 63 64

2BH1400-7..2. 63 64

2BH1430-7..0. 63 64

2BH1430-7..1. 63 64

2BH1430-7..2. 63 64

2BH1500-7..0. 64 70

2BH1500-7..1. 64 70

2BH1500-7..2. 64 70

2BH1500-7..3. 64 70

2BH1530-7..0. 64 70

2BH1530-7..1. 64 70

2BH1530-7..2. 64 70

2BH1530-7..3. 64 70

2BH1600-7..0. 69 72

2BH1600-7..1. 69 72

2BH1600-7..2. 69 72

2BH1600-7..3. 69 72

2BH1600-7..6. 69 72

2BH1600-7..7. 69 72

2BH1630-7..0. 69 72

© Gardner Denver Deutschland GmbH 9 / 32 610.44434.40.000

Single-impeller design

Type 1-m measuring-surface sound pressure level

L [dB (A)]

50 Hz approx.

60 Hz approx.

2BH1630-7..1. 69 72

2BH1630-7..2. 69 72

2BH1630-7..3. 69 72

2BH1630-7..6. 69 72

2BH1630-7..7. 69 72

2BH180.-7..0. 70 74

2BH180.-7..1. 70 74

2BH180.-7..2. 70 74

2BH183.-7..0. 70 74

2BH183.-7..1. 70 74

2BH183.-7..2. 70 74

2BH190.-7..0. 74 79

2BH190.-7..1. 74 79

2BH190.-7..3. 74 79

2BH193.-7..0. 75 80

2BH193.-7..1. 75 80

2BH193.-7..3. 75 80

2BH923.. 79 81

Type 1-m measuring-surface sound pressure level

L [dB (A)]

50 Hz approx.

60 Hz approx.

2BH1310-7..2. 55 61

2BH1410-7..3. 66 69

2BH1410-7..4. 66 69

2BH1510-7..4. 72 74

2BH1510-7..5. 72 74

2BH1610-7..1. 73 76

2BH1610-7..2. 73 76

2BH1610-7..3. 73 76

2BH1610-7..4. 73 76

2BH1610-7..5. 73 76

2BH1610-7..7. 73 76

2BH1610-7..8. 73 76

2BH1640-7..3. 74 78

2BH1640-7..4. 74 78

2BH1640-7..5. 74 78

2BH1640-7..8. 74 ---

2BH181.-7..1. 74 ---

2BH181.-7..2. 74 78

2BH181.-7..3. 74 78

2BH181.-7..4. 74 78

2BH184.-7..2. 74 78

2BH184.-7..3. 74 78

2BH191.-7..1. 74 84

2BH191.-7..2. 74 84

2BH191.-7..3. 74 84

2BH1940-7B.2. 75 84

2BH1940-7B.3. 75 84

2BH1940-7B.4. 75 84

2BH1943-7..2. 75 84

2BH1943-7..3. 75 84

2BH1943-7..4. 75 84

610.44434.40.000 10 / 32 © Gardner Denver Deutschland GmbH

Sound power level

Sound power level LW as per EN ISO 3744, tolerance 3 dB (A).

Two-impeller design

Sound power level LW [dB (A)]

Type 50 Hz 60 Hz

2BH191. - 98

2BH1940 - 98

2BH1943 - 99

2BH923.. - 93

Tightening torques for screw connections

The following values apply if no other information is available.

With non-electrical connections, property classes of 8.8 and 8 or higher as per ISO 898-1 are assumed.

Tightening torques for non-electrical connections

Thread [Nm] [ft lbs]

M4 2.7 - 3.3 1.99 - 4.44

M5 3.6 - 4.4 2.65 - 3.25

M6 7.2 - 8.8 5.31 - 6.5

M8 21.6 - 26.4 15.9 - 19.5

M10 37.8 - 46.2 27.9 - 34.1

M12 63.0 - 77.0 46.5 - 56.8

The following information for electrical connection applies to all terminal board connections with the exception of terminal strips.

Tightening torques for electrical connections

Thread [Nm] [ft lbs]

M4 0.8 - 1.2 0.59 - 0.89

M5 1.8 - 2.5 1.33 - 1.84

Especially for metal and plastic threaded cable glands and pipe unions, the following values apply:

Tightening torques for metal threaded glands/unions

Thread [Nm] [ft lbs]

M12x1,5 4 - 6 2.95 - 4.43

M16x1,5 5 - 7.5 3.69 - 5.53

M25x1,5 6 - 9 4.43 - 6.64

M32x1,5

M40x1,5 8 - 12 5.9 - 8.85

Tightening torques for plastic threaded glands/unions

Thread [Nm] [ft lbs]

M12x1,5 2 - 3.5 1.48 - 2.58

M16x1,5 3 - 4 2.21 - 2.95

M25x1,5 4 - 5 2.95 - 3.69

M32x1,5

M40x1,5 5 - 7 3.69 - 5.16

© Gardner Denver Deutschland GmbH 11 / 32 610.44434.40.000

3.2 Electrical data

See rating plate.

3.3 Operating conditions

Temperatures max. permissible temperature:

+40°C [+104°F]

Nominal value:

+15°C [+59°F]

Temperature of pumped gases:

Pump-motor units for higher fluid temperatures on request.

max. permissible temperature:

+40°C [+104°F] min. permissible temperature:

-15°C [+5°F]

Nominal value:

+25°C [+77°F]

Ambient temperature:

Ambient temperatures between 25°C [+77°F] and 40°C [+104°F] affect the permissible total pressure difference.

At higher temperatures the winding may be damaged and the grease change interval may be shortened.

Pressures

Min. suction pressure: See rating plate

Max. discharge pressure in compressor mode:

See rating plate

* The total pressure difference, shown on the rating plate, applies only for the following conditions:

Ambient temperature: 25°C Pressure for vacuum operation:

1013 mbar at pressure connection;

Pressure for compressor operation:

1013 mbar at suction connection;

Intake temperature (temperature of conveyed gases at suction connection): 15°C For ambient temperatures between 25°C and 40°C, the total pressure difference specified on the rating plate must be reduced (at 40°C by 10%).

Consultation with the manufacturer is essential for such operational conditions.

Installation altitude

Max. of 1,000 m [3,280 ft] above sea level.

When installing the pump-motor unit at an altitude of more than 1,000 m [3,280 ft] above sea level, first inquire with the Service department.

Section 4: Transport and Handling

Transport and Handling

610.44434.40.000 12 / 32 © Gardner Denver Deutschland GmbH

4 Transport and Handling

Tipping or falling can lead to crushing, broken bones etc.! Sharp edges can cause cuts!

Wear personal safety equipment (gloves, safety shoes and protective helmet) during transport!

Danger from tipping or falling loads!

Prior to transport and handling make sure that all components are securely assembled and secure or remove all components the fasteners of which have been loosened!

Manual handling:

Danger from lifting heavy loads!

Manual handling of the unit is only permitted within the following limits:

max. 30 kg [max. 66 lbs] for men max. 10 kg [max. 22 lbs] for women max. 5 kg [max. 11 lbs] for pregnant women For the weight of the pump-motor unit, see Chapter 3.1, "Mechanical data", Section "Weight", Pg. 7. For weights above the given values use suitable lifting appliances and handling equipment!

Handling by means of lifting equipment:

Danger from tipping or falling loads!

When transporting with lifting equipment, observe the following basic rules:

Before each transport, check the tight fit of the eye bolt/lifting attachment, see "Tightening torques for screw connections",

p. 10.

The lifting capacity of lifting equipment and lifting gear must be at least equal to the unit's weight. For the weight of the pump-motor unit, see Chapter 3.1, "Mechanical data", Section "Weight", Pg. 7.

The pump-motor unit must be secured so that it cannot tip or fall.

Do not stand or walk under suspended loads!

The transport must be carried out in different ways depending on the type:

2BH11., 2BH12., 2BH13., 2BH14., 2BH15.

(single-impeller): Manual handling

2BH15. (two-impeller), 2BH16., 2BH18., 2BH19., 2BH923…

Transport with crane, hooked onto eye bolt/lifting attachment (1 attachment point)

2BH1943:

Transport with crane, hooked with lifting belts onto eye bolt and onto the holes in the two feet of the vacuum pump/compressor housing (3 attachment points).

For transport with a crane, the pump-motor unit can be hooked into the crane hook as follows:

directly on the eye bolt/lifting attachment (With 2BH194 the eye bolt and the two foot holes should be used) or possibly with lifting belts.

Eye bolt/lifting attachment:

Types with a weight of up to 30 kg [66 lbs] are not equipped with an eye bolt/lifting attachment

(2BH11., 2BH12., 2BH13., 2BH14., 2BH15

[single-impeller]).

Types with a weight of more than 30 kg [66 lbs] are equipped with an eye bolt/lifting attachment as standard (2BH15. [two-impeller], 2BH16., 2BH18., 2BH19., 2BH9…).

The eye bolt/lifting attachment is mounted on the vacuum pump/compressor housing.

In case of possible removal and remounting of the eye bolt, it must be ensured that the eye level is positioned exactly in the axis direction of the pump-motor unit. Lay shims under the eye bolt if necessary.

The eye bolt/lifting attachment must be firmly tightened.

Loads laterally to the ring level are not permissible. Heavy impact loads during transport must be avoided.

Section 5: Installation

Installation

© Gardner Denver Deutschland GmbH 13 / 32 610.44434.40.000

5 Installation

Improper use of the unit can result in serious or even fatal injuries!

Have you read the safety precautions in Chapter 1, "Safety", Pg. 3 f.?

Otherwise you many not carry out any work with or on the pump-motor unit!

Danger from missing view into area of pump-motor unit!

When operating the control elements without a view into the area of the pump-motor unit, there is a danger that the pump-motor unit will be switched on while other persons are still performing work on it. Extreme injuries are possible!

Provide control elements at a location with a view of the pump-motor unit.

The pump-motor unit must be installed so that the electrical device cannot be damaged by external influences!

In particular, the feed pipes must be securely routed, e.g. in cable ducts, in the floor etc.

Danger from balance damage caused by vibration!

Vibrating environments can cause balance damage!

Install the pump-motor unit on a solid foundation or on a solid mounting surface.

Check screw glands/unions for mounting the pump-motor unit on the mounting surface regularly for strength and firm seating.

Danger from crushing due to pump-motor unit tipping over!

Wear personal safety equipment (protective gloves and safety shoes). Handle the unit with the appropriate care. Install the pump-motor unit on a solid foundation or on a solid mounting surface! Check screw glands/unions for mounting the pump-motor unit on the mounting surface regularly for strength.

Danger of fire from flammable substances!

The pump-motor unit must never come into contact with flammable substances.

Danger of burns from hot surfaces of the pump-motor unit and from hot fluids!

High temperatures of up to approx. 160°C [320°F] can occur on the surface of the pump-motor unit.

The pump-motor unit must be installed so that accidental touch of its surface is not possible.

Cover the pump-motor unit with a suitable touch protection (e.g. perforated plate cover or wire cover).

Danger of injuries from flying parts!

Select installation so that parts that are thrown out through the grate if the external fan breaks cannot hit persons!

Danger of tripping and falling!

Make sure the unit does not present a danger of tripping. Lay cables and pipes so that they cannot be reached during operation(recessed in floor, in ducts on the wall etc.).

Danger of overheating due to hot surface of pump-motor unit!

High temperatures can occur on the surface of the pump-motor unit.

Temperature sensitive parts, such as lines or electronic components, may not come into contact with the surface of the pump-motor unit.

The pump-motor unit is ready to connect on delivery. However, if the time from delivery to commissioning of the pump-motor unit exceeds a certain period, the lubrication of the rolling bearings must be renewed.

See Chapter 8.2, "Storage conditions", Section "Lubrication of rolling bearings after longer storage", Pg. 24 for information on this topic.

610.44434.40.000 14 / 32 © Gardner Denver Deutschland GmbH

Carry out the following work to install the pump-motor unit:

Installation and securing, Attachment of the included loose muffler if necessary, Attachment of threaded flange or hose flange (available as accessories) for the connection of inlet or discharge pipe to the muffler, Electrical connection, Connection of inlet and discharge connection to the system.

5.1 Installation

For an installation that differs from the following specifications, it is necessary to inquire with the Service Department!

Ambient conditions:

The pump-motor unit is suitable for installation in the following environments:

In a dusty or damp environment, in buildings, in the open.

When properly installed in the open, the pump-motor unit must be protected from exposure to intensive sunlight, e.g. by attaching a protective roof. Otherwise, no special protective devices against the effects of weathering are required.

The drive motors of the pump-motor units have the following design:

with degree of protection IP55 (see rating plate), with tropicalized insulation.

Installation conditions:

The pump-motor unit must be installed as follows:

on level surfaces, at a maximum height of 1000 m [3280 ft] above sea level.

When installing at an altitude of more than 1,000 m [3,280 ft] above sea level, first inquire with the Service Department.

Minimum distances:

To ensure sufficient cooling of the pump-motor unit, it is absolutely necessary that the required minimum distances to the fan guard and to the face of the vacuum pump/compressor cover be maintained. see Chapter 3.1, "Mechanical data", Section "Minimum distances", Pg. 8.

The minimum distances to the face of the vacuum pump/compressor cover are especially important when installing on the vacuum pump/compressor cover or near a wall.

To ensure sufficient cooling of the pump-motor unit, also observe the following:

Ventilation screens and openings must remain clear.

Discharge air of other units may not be directly sucked in again!

Noise radiation:

To reduce the noise radiation, the following must be observed:

Do not mount pump-motor unit on noise-conducting or noise-radiating parts (e.g. thin walls or sheet-metal plates).

Provide pump-motor unit with sound-insulating intermediate layers (e.g. rubber buffers under the base of the pump-motor unit) if necessary.

Install the pump-motor unit on a stable foundation or on a rigid mounting surface.

This provides for smooth, low-vibration running of the pump-motor unit.

Components for reducing noise on the pump-motor unit:

Mufflers (included as standard equipment):

On delivery the pump-motor units are equipped with attached mufflers as standard.

The noise radiation is considerably reduced by the mufflers. See Fig. 2 to Fig. 9, Pg. 18 ff.

Additional silencer (available as an accessory for the 2BH1):

The additional mufflers enable a further noise reduction. They may only be used with free entry and exit of gases, i.e. with direct intake out of or direct feeding into the atmosphere without piping.

© Gardner Denver Deutschland GmbH 15 / 32 610.44434.40.000

Sound protection hood (available as an accessory for the 2BH1):

Noise protection hoods are suitable for installation in rooms and in the open. They reduce both the total sound pressure level and tonal components that are perceived as particularly annoying.

Installation variants/axis position:

Basically, when installing the pump-motor unit, the following variants are possible with a different axis position (horizontal or vertical):

Horizontal installation

Vertical installation on the vacuum pump/compressor cover ("cover installation")

Vertical mounting on the wall

Basically, all variants are possible with all type.

Exceptions

For the 2BH1943, vertical axis mounting on the compressor cover ("cover position") is necessary.

For the 2BH923, only horizontal axis mounting and vertical axis mounting on the compressor cover are possible.

For units with condensate water opening, horizontal axis mounting with a foot below is necessary.

Horizontal axis mounting

The foot of the unit has fastening holes.

Screw the foot of the unit to the base using suitable screws.

All fastening holes must have screws!

Vertical axis mounting on the compressor cover ("cover position")

For vertical axis mounting on the compressor cover, use spring elements.

Spring elements are available as accessories and come in a set of 3. The upper part has a threaded stud and the lower part a threaded hole.

fFastening spring elements to the unit:

Screw threaded studs of the spring elements into the holes on the front side of the compressor cover and tighten.

Fastening the unit with spring elements to the foundation:

Select suitable fastening elements for the threaded hole.

Screw spring elements over the threaded hole into the base or foundation.

Vertical axis mounting on the wall with the compressor cover pointing downward

For vertical axis mounting of the unit on the wall, the unit is fastened using the holes in the foot.

The foot of the unit has fastening holes.

Place the unit with the foot to the wall on a base plate with sufficient load-bearing capability in the mounting position.

Screw the foot of the unit to the wall using suitable screws.

All fastening holes must have screws!

Remove the base plate.

Eye bolt/lifting attachment:

After set-up, the eye bolt/lifting attachment can be removed.

5.2 Electrical connection (motor)

Electrical danger!

Malpractice can result in severe injuries and material damage!

The electrical connection may be carried out by trained and authorized electricians only!

Before beginning work on the unit or system, the following measures must be carried out:

Deenergize.

Secure against being switched on again.

Determine whether deenergized.

Incorrect connection of the motor can lead to serious damage to the unit!

Regulations:

The electrical connection must be carried out as follows:

according to the applicable national and local laws and regulations, according to the applicable system-dependent prescriptions and requirements, according to the applicable regulations of the utility company.

610.44434.40.000 16 / 32 © Gardner Denver Deutschland GmbH

Electrical power supply:

Observe the rating plate.

It is imperative that the operating conditions correspond to the data given on the rating plate!

Deviations permissible without reduction in performance:

±5 % voltage deviation

±2 % frequency deviation

Connection to drive-motor terminal box:

Open the required cable entry openings on the terminal box. Here the following two cases are differentiated:

The cable entry opening is prefabricated and provided with a sealing plug.

Screw out sealing plug.

OR

The cable entry opening is closed off with a casting skin (only on pump-motor units with drive-motor axis heights of 100 to 160 in standard design).

Break out casting skin using a suitable tool.

For example, use a metal pin with a corresponding diameter or a chisel and hammer.

CAUTION

When pounding out the casting skin on the cable entry openings in the terminal box, the terminal box or its parts can be damaged (e.g.

terminal board, cable connections).

Proceed with suitable caution and precision when doing so! Prevent flash formation!

Mount cable glands on the terminal box. Proceed as follows:

Select one cable gland in each case which is suitable for the cable diameter.

Insert this cable gland in the opening of the terminal box.

Use a reducer if necessary.

Screw on the cable gland so that no moisture, dirt etc. can penetrate into the terminal box.

Carry out the connection and the arrangement of the jumpers in accordance with the circuit diagram in the terminal box.

Connect the protective conductor to the terminal with the following symbol:

The electrical connection must be carried out as follows:

The electrical connection must be permanently safe.

There may be no protruding wire ends.

Clearance between bare live parts and between bare live parts and ground: ≥ 5.5 mm [0.217"] (at a nominal voltage of UN ≤ 690V).

For the tightening torques for terminal board connections (except terminal strips), see Chapter 3.1, "Mechanical data", Section "Tightening torques for screw connections", Pg. 10.

For terminals with clamping straps (e.g. as per DIN 46282), the conductors must be inserted so that approximately the same clamping height results on both sides of the bar.

Individual conductors must therefore be bent into a U-shape or connected with a cable lug

(DIN 46234).

This also applies to:

the protective conductor, the outer ground conductor.

Both conductors can be recognized from their color (green/yellow).

The terminal box must be free from foreign bodies, dirt, humidity.

Terminal box cover and cable entries must be tightly closed so as to make them dustproof and waterproof. Check for tightness at regular intervals.

Clearance between bare live parts and between bare live parts and ground:

at least 5.5 mm [0.217"] (at a nominal voltage of UN ≤ 690V).

There may be no protruding wire ends!

© Gardner Denver Deutschland GmbH 17 / 32 610.44434.40.000

For motor overload protection:

Use motor circuit breakers.

This must be adjusted to the specified nominal current (see rating plate).

There is danger of an electrical shock when a defective pump-motor unit is touched!

Mount motor circuit breaker.

Have electrical equipment checked regularly by an electrician.

Interference immunity of drive motor:

For drive motors with integrated sensors, the operator must provide for a sufficient interference immunity itself. Select a suitable sensor signal cable (e.g. with screening, connection as for a motor power-supply cable) and analyzing unit.

Operation with frequency converter:

Pump-motor units with a UL approbation may not be operated on frequency converters in the US without testing by a suitable test agency!

With a power supply by a frequency converter, the following must be observed:

High-frequency current and voltage harmonics in the motor supply cables can lead to emitted electromagnetic interference. This is dependent on the converter design (type, manufacturer, interference suppression measures).

Be sure to observe the EMC notes of the converter manufacturer!

Use screened power supply cables if necessary. For optimal screening, the screen must be conductively connected over a large area to the metal terminal box of the drive motor with a screwed metal gland.

In the case of drive motors with integrated sensors (e.g. PTC thermistors) interference voltage can occur on the sensor cable depending on the converter type.

Limit speed:

see specifications on the rating plate.

610.44434.40.000 18 / 32 © Gardner Denver Deutschland GmbH

5.3 Connecting pipes/hoses (vacuum

pump/compressor)

Mufflers:

The pump-motor units are delivered with mufflers (indicated with arrows in the following illustrations) for the inlet and discharge connections as standard equipment.

On delivery the mufflers are already mounted on the following pump-motor units.

Fig. 2: 2BH1… (single-impeller pump-motor units), 2BH9 23

Fig. 3: 2BH1640 (two-impeller pump-motor unit with double-flow design)

Fig. 4: 2BH1840-7G... (two-impeller pump-motor unit with double-flow design)

Fig. 5: 2BH1840-7J... (two-impeller pump-motor

Fig. 6: 2BH1840-7L... (two-impeller pump-motor

Fig. 7: 2BH1943 (two-impeller pump-motor unit with double-flow design)

On two-impeller pump-motor units with a two-stage design of the types 2BH1310 to 2BH1910 the discharge-side muffler is included loose for packing-related reasons and must be mounted by the customer.

Fig. 8: 2BH1310 ... 2BH1610, 2BH1910 (two-impeller pump-motor units with a two-stage design)

Fig. 9: 2BH1810 (two-impeller pump-motor unit with a two-stage design)

© Gardner Denver Deutschland GmbH 19 / 32 610.44434.40.000

Cutting/cutting of off extremities!

The rotating impeller is accessible with the inlet and discharge connections open!

With free entry and exit of gases, i.e. with direct intake out of or direct feeding into the atmosphere without piping, the following therefore applies:

Provide the inlet and discharge connections of the pump-motor unit either with additional mufflers or with additional piping of a sufficient length to prevent access to the impeller!

Connections:

To prevent foreign bodies from entering the unit, all connections are sealed off when delivered. Do not remove the sealing plugs until immediately before connecting the pipes/hoses.

The following applies for the arrangement of the pipe/hose connections:

The pumped gases are sucked in via the inlet connection (see Chapter 5.3.1, Pg. 19) and discharged via the discharge connection (see Chapter 5.3.2, Pg. 19).

The shaft rotating direction is marked with an arrow on the back of the vacuum pump/compressor housing (Fig. 1, Pg. 2, Item 7).

The delivery direction of the gases is marked with arrows on both connections (Fig. 1, Pg. 2, Item 6).

Danger from interchanging inlet and pressure line!

Interchanged inlet and pressure lines can lead to damage to the pump-motor unit and the system, and as a result of this to serious injuries!

Make sure that the inlet and pressure line cannot be confused when connecting.

Look for the clear marking with the arrow indicating the delivery direction on the inlet and discharge connections.

Danger due to vacuum and gauge pressure!

Danger due to escaping fluid!

During operation, connected pipes and vessels are vacuumized or pressurized!

Use only mounting elements, connections, lines, fittings and containers with sufficient freedom from leaks and strength for the pressures which occur.

Make sure that the mounting elements and connections are mounted sufficiently firmly and leak-free!

If the pumped gases are passed on on the discharge side in a closed pipe system, then it must be ensured that the pipe system is adapted to the maximum discharge pressure.

See Chapter 3.3: "Operating conditions", Section "Pressures", Pg. 11. Connect a pressure relief valve upstream if necessary.

NOTICE

Attach pipes/hoses free of mechanical tensions.

Support the weight of the pipes/hoses.

5.3.1 Inlet connection

The inlet connection with the related muffler (Fig. 1, Pg. 2, Item 3) is marked with an arrow pointing into the vacuum pump/compressor.

Connect the inlet pipe here. The pumped gases are sucked in via this.

Procedure: see Chapter 5.3.3.

Danger from solid bodies and impurities in the pump-motor unit!

If solid bodies penetrate into the pump-motor unit, blades of the impellers can break and broken pieces can be thrown out.

Install a filter in the inlet pipe.

Replace filter regularly!

5.3.2 Discharge connection

The discharge connection with the related muffler (Fig. 1, Pg. 2, Item 4) is marked with an arrow pointing out of the vacuum pump/compressor.

Connect the discharge pipe here. The pumped gases are discharged via this. Procedure: see Chapter 5.3.3.

610.44434.40.000 20 / 32 © Gardner Denver Deutschland GmbH

5.3.3 Procedure when connecting

pipes/hoses

Attach the pipes/hoses to the unit as described in the following. The pipes/hoses are connected differently to inlet and discharge connections depending on the muffler design and the type of line (pipe or hose):

Muffler with inside threads:

The pipe is screwed directly into the muffler.

Muffler without inside thread:

– Screw threaded flange (available as an accessory) onto the muffler.

– Screw the pipe into the threaded flange.

Hose connection:

– for 2BH1 Screw the hose flange (available as an accessory) onto the silencer.

– Push the hose onto the hose flange and secure it with a hose clamp. See Chapter 3.1, "Mechanical data", Section "Tightening torques for screw connections", Pg. 10 for information on this topic.

Section 6: Commissioning

Commissioning

© Gardner Denver Deutschland GmbH 21 / 32 610.44434.40.000

6 Commissioning

Improper use of the unit can result in serious or even fatal injuries!

Have you read the safety precautions in Chapter 1, "Safety", Pg. 3 f.? Otherwise you many not carry out any work with or on the pump-motor unit!

Danger from rotating parts (external fan, impeller, shaft): Cutting/cutting off of extremities, Grasping/winding up of hair and clothing!

Danger due to vacuum and gauge pressure:

sudden escape of fluids (skin and eye injuries), sudden drawing in of hair and clothing!

Danger due to escaping fluid: Burns!

Start-up and operation only under the following conditions:

The pump-motor unit must be completely assembled. When doing so, pay particular attention to the following components:

– the vacuum pump/compressor cover,

– the muffler on inlet and discharge connections,

– the fan guard.

The pipes/hoses must be connected to inlet and discharge connections.

Inlet and discharge connections and the connected pipes/hoses may not be closed, clogged or soiled.

Check the mounting elements, connections of the pipe/hose connections, lines, fittings and containers for strength, leaks and firm seating at regular intervals.

6.1 Preparation

Danger from closed connections!

With closed/soiled intake or discharge connections vacuum or gauge pressure results in the pump-motor unit.

This can overheat and damage the drive motor winding.

Before start-up, make sure that the inlet and discharge connections are not closed, clogged or soiled!

Before starting up again after a longer standstill:

Measure the insulation resistance of the motor.

With values ≤ 1 kΩ per volt of nominal voltage, the winding is too dry.

Measures before start-up:

If a shut-off device is installed in the discharge pipe:

Make sure that the unit is NOT operated with the shut-off device closed.

Before starting up the pump-motor unit, observe the values specified on the rating plate. Specifications on the drive-motor nominal current apply at a gas entry and ambient…