Attachment 7 - 5.2.6 P451 ARCHITECTURAL Floor Plan A-122 - Ceiling Detail.pdf

PDF 755 KB Posted

Attached to
Air Compressor Travis AFB Federal contract opportunity
Solicitation number
FA442725Q1041
Issued by
Department of the Air Force Air Mobility Command

About this file

This document is a Reflected Ceiling Plan (A-122) for Area A of the KC-46A Regional Maintenance Training Facility at Travis Air Force Base, California. The architectural drawing details the ceiling layout, featuring a comprehensive grid of 2'x2' acoustical tile ceiling with T-bar grid, gypsum board ceiling systems, and various lighting fixtures including recessed troffers, pendant lights, recessed can lights, and surface-mounted light fixtures. The plan also indicates electrical components such as supply, return, and exhaust air registers, fire sprinkler heads, and cable trays.

The drawing is part of the final design submittal dated 11/19/21 for the Naval Facilities Engineering Command (NAVFAC) Southwest, with the project number 18335931 and contract number N62473-18-D-5855-N6247321F4392. The ceiling plan covers multiple rooms including Engine/APU, Hydraulic Power Unit (HPU), server rooms, offices, halls, mechanical spaces, and storage areas, with varying ceiling heights ranging from 8' to 12'. The document includes a key plan, legend, and general sheet notes, with a metal panel soffit in MS Almond color noted as a specific design element.

View the file

Other files for this federal contract opportunity

Show all 12

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

M

M

M

M

M

M

M

M M

PC

PC

PC

PC

PC

PC

3T

03T

03T

03T

03T

03T

03T

3T

03T ACOUSTICAL TILE CEILING - 2'X2' T-BAR GRID

GYPSUM BOARD CEILING SYSTEM

FULL HEIGHT WALL

RECESSED TROFFER LIGHT FIXTURE

PENDANT LIGHT FIXTURE

SURFACE MOUNTED LIGHT FIXTURE

SUPPLY AIR REGISTER

RETURN AIR REGISTER

EXHAUST AIR REGISTER

FIRE SPRINKLER HEAD

OPEN TO STRUCTURE ABOVE - PAINT ALL EXPOSED

STRUCTURE

O.T.S.

RECESSED CAN LIGHT

OCCUPANCY SENSOR

AA

6 6.9

DD

F

ENGINE/APU

LGT

FDAT

MECH

ART (BOOM)

FCT

HPU

CLS SERVER

CLS OFFICE

HALL

100C

BDF

CTK

ELEC

STOR

10' - 0"

JAN

8' - 0"

8' - 0"

9' - 0"

10' - 0"

12' - 0"

12' - 0"

10' - 0"

O.T.S.

O.T.S.

O.T.S.

O.T.S.

O.T.S.

O.T.S.

E E

4 5 7 10

9 11 13

H

B

C

G

07.07

D5

A-541

D2

A-541

A3

A-541

C5

A-541

FDAT

MECH

HALL

100B

FDAT

MECH

HALL

100E 27.04

L

EC

TRL

C

NO. C-25863

E R

ET

A T

S

O F

N .

G

LA I F

- 1 NRO

A I

M.

DES

NECI

EN N

RCH

LLIM

E

IT

A

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

S

O U

TH

W

E S

T S

A N

D

IE

G O

C

A L

IF

O R

N

IA

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

DESIGN/BUILD

GENERAL CONTRACTOR

2424 CONGRESS STREET

SAN DIEGO, CA 92110

619-296-6247

JC

JP

F

IN

A L

D E

S

IG

N S

U B

M

IT

T A

L

/1

/2

A-122

P -4

K

C -4

A

R E

G

IO

N A

L M

A

IN

T E

N A

N C

E

T R

A

IN

IN

G

F A

C

IL

IT

Y

R E

F L E

C T

E D

C E

IL

IN

G P

L A

N

A R

E A

A

DZ

18335931

GM TA

1608215

N62473-18-D-5855-N6247321F4392

T R

A V

IS

A

F B

, C A

T R

A V

IS

A

IR

F

O R

C E

B A

S E

07.07 METAL PANEL SOFFIT. MS ALMOND COLOR

27.04 CABLE TRAY, REFER TO TELECOM DRAWINGS

GENERAL SHEET NOTES

KEY PLAN

KEYNOTES

LEGEND

0 4' 8' 16'

PLAN

NORTH

SCALE: 1/8" = 1'-0"

REFLECTED CEILING PLAN - AREA A

A

B C

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

A C

D W

R E

P O

R T

/2

1/

B D

E S

IG

N

D E

V E

LO

P

M E

N T

S U

B M

IT

T

A L

/0

2/

C P

R E

-F

IN

A L

D E

S

IG

N S

U B

M

IT

T A

L

/1 0/

D F

IN

A

L D

E S

IG

N

S U

B M

IT

T

A L

/1

9/

File details come from the government source that posted it. Updated .