FA3099-25-Q-1020 QA.pdf

PDF 124 KB Posted

Attached to
Synopsis-Command Post Badging System
Solicitation number
FA3099-25-Q-1020
Issued by

About this file

This document is a Questions and Answers (Q&A) file for a Command Post Badging System contract (Solicitation Number FA3099-25-Q-1020). The Q&A provides details about an access control system upgrade, revealing that the current system uses a SECURITRON DK-26 Digital Keypad. Key insights include the client's preference to reuse existing locking mechanisms and a desire to avoid installing access control panels in the COMM Closet due to limited administrator access. The facility has a drop ceiling with unknown height, and there is no preferred system manufacturer, though the system must meet the Salient Characteristics document requirements.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Command Post Badging System

FA3099-25-Q-1020

Questions and Answers:

Q1: Are these doors currently controlled by an access control system?

A1: The doors are currently controlled by a SECURITRON DK-26 Digital Keypad.

Q2: If so, can you provide the name of the system?

A2: SECURITRON DK-26

Q3: If yes to above, do these doors currently have fully functional operating locking mechanisms (Strikes, Mag locks, ETC) that can be reused, or will they need to be replaced?

A3: The request is to use existing locking mechanisms

Q4: Can the access control panels be installed in the COMM Closet shown on the drawing?

A4: Yes, but that is not our preference as the administrators do not have 24/7 access to that closet.

Q5: How tall are the ceilings and what type of ceiling?

A5: Height unknown / drop ceiling.

Q6: Is there a preferred system manufacturer? Or any that will meet the Salient Characteristics document?

A6: No Preference

File details come from the government source that posted it. Updated .