AccessDoorSite_Visit_Slides.pptx
PPTX presentation 231 KB Posted
- Attached to
- Electronic Door Access System Federal contract opportunity
- Solicitation number
- FA3002-17-R-0020
About this file
Site Visit presentation
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Attachment_2_PWS.doc | DOC document | |
| Q&A_2.xlsx | XLSX spreadsheet | |
| Amendment_002.docx | DOCX document | |
| FA3002-17-R-0020-001_Amendment.pdf | ||
| Q&A_1.xlsx | XLSX spreadsheet | |
| Q&A.xlsx | XLSX spreadsheet | |
| Combined_Synopsis_AFSAT_Door_Locks.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Dawn Melchione, 338 SCONS Contracting Officer Kyle Torres, AFSAT/MSO, Requirement Owner James D. Trimble, AFSAT/MS, Program Manager
Electronic Door Access System Site Visit
12 September 2017
I n t e g r i t y - S e r v i c e - E x c e l l e n c e
Air Force Installation Contracting Agency Be America’s Best…War-Winning Capabilities, on Time, on Cost
Overview
Welcome/Introductions Rules of Engagement AFSAT PWS/Requirement Overview Points of Contact
Welcome
Welcome Platform for open discussion/exchange ideas
Rules of Engagement Written Questions Question forms provided All Q&As will be recorded and posted on FBO This event is an open exchange with Industry; any verbal question/answer SHALL NOT be binding COST specific questions will not be addressed
HQ AETC PERFORMANCE WORK STATEMENT OVERVIEW
Kyle Torres
AFSAT/MSO
Requirement Owner
James D. Trimble
AFSAT/MS
Program Manager
PWS/Requirement Overview
1.2 Scope
AFSAT needs Electronic Door Access System Building 856 and 857 installed. The old system and cypher locks needs to be removed and taken away. Hardware required to be installed:
| Programmable door controller allowing AFSAT personnel to program | individual personnel access to building, set door lock and unlock times. | The software to run the system (easy to operate by untrained | personnel) |
| Panic lock down switch installed in each building to allow on demand | lock down of all doors with installed systems. | ||
| CAC Card enroller to register new users | |||
| Keyboard to input required data | |||
| Computer Monitor | |||
| Battery Back Up that lasts 8 hours |
PWS/Requirement Overview
| CAC Card Readers at 8 Doors (see attached building maps) | with locks on 8 doors with electronic latch locks that allow key | override. CAC Card Readers need to have their own power | supply. |
| Egress motion sensors on 8 doors allowing personnel to exit | the building in all modes. Must be operational during any and | all emergencies. |
PWS/Requirement Overview Provide a new Electronic Door Access System Building 856 and 857 that is FIPS compliant Remove and dispose of current Electronic Door Access System Building 856 and 857.
Install new Electronic Door Access System Building 856 and 857 as detailed in PWS paragraph 1.2 All hardware and software is FIPS complaint to standard 201-1 and 202-1 standards.
Provide 1 year warranty on all hardware and software. System shall be 99% reliable and if it breaks down it will be repaired under warranty with in one calendar days of notification of failure.
Clean all packing material and or other debris from work site upon work completion.
PWS/Requirement Overview
3.2 Provide maintenance of system after warranty
System shall be 99% reliable and if it breaks down it will be repaired within one calendar days of notification of failure.