S C_IDIQ_RFP_Bid_Schedule_(Line_Items)_-_14_Aug_15.xlsx
XLSX spreadsheet 278 KB Posted
- Attached to
- Steam & Condensate IDIQ Federal contract opportunity
- Solicitation number
- FA2835-15-R-0020
About this file
Steam and Condensate IDIQ Bid Schedule (Excel Format).
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| FA2835-15-R-0020_Answers_to_Questions.pdf | ||
| S C_IDIQ_RFP_Bid_Schedule_(Line_Items)_-_25_Aug_15.xlsx | XLSX spreadsheet | |
| S C_amendment.pdf | ||
| S C_IDIQ_2015_Q A.docx | DOCX document | |
| Attachment_5_SC_IDIQ_Bid_Schedule_(Line_Items)_-to_include_subheadings.pdf | ||
| PZIA-15-0146_FA2835-15-R-0020_RFP_Cover_Letter.pdf | ||
| FA2835-15-R-0020_Steam_IDIQ_Request_for_Proposal.pdf | ||
| Attachment_1_Steam_ _Condensate_Specifications.pdf | ||
| PZIA-15-0146_FA2835-15-R-0020_RFP_Cover_Letter.pdf | ||
| Attachment_2_Steam_ _Condensate_IDIQ_Master_Plan.pdf | ||
| Attachment_3_Steam_ _Condensate__IDIQ_SOW.pdf | ||
| Attachment_4_Steam_ _Condensate_Line_Drawings.pdf | ||
| Attachment_6_Wage_Determinations.pdf | ||
| Attachment_5_Contractor_S C_IDIQ_Bid_Schedule.pdf | ||
| Questions_for_SolicitationFA2835-15-R-0020.pdf |
Show all 15
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Summary
| Period | Description | Estimated Quantity | U/M | Unit | |
| Price | Total |
| 01 | Period 01 (15 Sep 15 - 30 Sep 16) | 1 | EA |
| 02 | Period 02 (01 Oct 16 - 30 Sep 17) | 1 | EA |
| 03 | Period 03 (01 Oct 17 - 30 Sep 18) | 1 | EA |
| 04 | Period 04 (01 Oct 18 - 30 Sep 19) | 1 | EA |
| 05 | Period 05 (01 Oct 19 - 30 Sep 20) | 1 | EA |
| Contract Total: |
&"Arial,Bold"&14Steam and Condensate IDIQ &D &"Arial,Bold"&14FY2015 Contract (5 Year Ordering Period) Summary - All Periods
&"Arial,Regular"&12&D, &T &"Arial,Regular"&12&F, &A &"Arial,Regular"&12&P of &N
BID (1)
| Sub Sch | Line No. | DESCRIPTION | ESTIMATED | |
| QUANTITY | UM | UNIT | ||
| PRICE | ESTIMATED |
TOTAL
| PIPES & FITTINGS IN CONCRETE TRENCHES | ||||||
| A | A01 | Replace Pipe (12") Schedule 40 | 100 | LF | ||
| A | A02 | Replace Pipe (10") Schedule 40 | 20 | LF | ||
| A | A03 | Replace Pipe (8") Schedule 40 | 40 | LF | ||
| A | A04 | Replace Pipe (6") Schedule 40 | 40 | LF | ||
| A | A05 | Replace Pipe (5") Schedule 40 | 20 | LF | ||
| A | A06 | Replace Pipe (4") Schedule 40 | 80 | LF | ||
| A | A07 | Replace Pipe (3") Schedule 40 | 20 | LF | ||
| A | A08 | Replace Pipe (2") Schedule 40 | 100 | LF | ||
| A | A09 | Replace Fitting (12") Schedule 40 | 10 | EA | ||
| A | A10 | Replace Fitting (10") Schedule 40 | 10 | EA | ||
| A | A11 | Replace Fitting (8") Schedule 40 | 10 | EA | ||
| A | A12 | Replace Fitting (6") Schedule 40 | 10 | EA | ||
| A | A13 | Replace Fitting (5") Schedule 40 | 10 | EA | ||
| A | A14 | Replace Fitting (4") Schedule 40 | 10 | EA | ||
| A | A15 | Replace Fitting (3") Schedule 40 | 10 | EA | ||
| A | A16 | Replace Fitting (2") Schedule 40 | 10 | EA | ||
| A | A17 | Replace Pipe (12") Schedule 80 | 100 | LF | ||
| A | A18 | Replace Pipe (10") Schedule 80 | 80 | LF | ||
| A | A19 | Replace Pipe (8") Schedule 80 | 80 | LF | ||
| A | A20 | Replace Pipe (6") Schedule 80 | 100 | LF | ||
| A | A21 | Replace Pipe (5") Schedule 80 | 80 | LF | ||
| A | A22 | Replace Pipe (4") Schedule 80 | 20 | LF | ||
| A | A23 | Replace Pipe (3") Schedule 80 | 60 | LF | ||
| A | A24 | Replace Pipe (2") Schedule 80 | 100 | LF | ||
| A | A25 | Replace Fitting (12") Schedule 80 | 10 | EA | ||
| A | A26 | Replace Fitting (10") Schedule 80 | 10 | EA | ||
| A | A27 | Replace Fitting (8") Schedule 80 | 10 | EA | ||
| A | A28 | Replace Fitting (6") Schedule 80 | 10 | EA | ||
| A | A29 | Replace Fitting (5") Schedule 80 | 10 | EA | ||
| A | A30 | Replace Fitting (4") Schedule 80 | 10 | EA | ||
| A | A31 | Replace Fitting (3") Schedule 80 | 10 | EA | ||
| A | A32 | Replace Fitting (2") Schedule 80 | 10 | EA | ||
| A | A33 | Remove/Insulate 1 1/2" Pipe including Aluminum Jacket | 200 | LF | ||
| A | A34 | Remove/Insulate 2" Pipe including Aluminum Jacket | 240 | LF | ||
| A | A35 | Remove/Insulate 3" Pipe including Aluminum Jacket | 200 | LF | ||
| A | A36 | Remove/Insulate 4" Pipe including Aluminum Jacket | 220 | LF | ||
| A | A37 | Remove/Insulate 5" Pipe including Aluminum Jacket | 200 | LF | ||
| A | A38 | Remove/Insulate 6" Pipe including Aluminum Jacket | 220 | LF | ||
| A | A39 | Remove/Insulate 8" Pipe including Aluminum Jacket | 240 | LF | ||
| A | A40 | Remove/Insulate 10" Pipe including Aluminum Jacket | 240 | LF | ||
| A | A41 | Remove/Insulate 12" Pipe including Aluminum Jacket | 200 | LF | ||
| PIPES & FITTINGS DIRECT BURIED | ||||||
| B | B01 | 12" Pipe Schedule 40 Steam/Condensate | 60 | LF | ||
| B | B02 | 10" Pipe Schedule 40 Steam/Condensate | 80 | LF | ||
| B | B03 | 8" Pipe Schedule 40 Steam/Condensate | 200 | LF | ||
| B | B04 | 6" Pipe Schedule 40 Steam/Condensate | 40 | LF | ||
| B | B05 | 5" Pipe Schedule 40 Steam/Condensate | 40 | LF | ||
| B | B06 | 4" Pipe Schedule 40 Steam/Condensate | 200 | LF | ||
| B | B07 | 2" Pipe Schedule 40 Steam/Condensate | 100 | LF | ||
| B | B08 | 1 1/2" Pipe Schedule 40 Steam/Condensate | 80 | LF | ||
| B | B09 | 1 1/4" Pipe Schedule 40 Steam/Condensate | 80 | LF | ||
| B | B10 | 12" Pipe Schedule 80 Steam/Condensate | 80 | LF | ||
| B | B11 | 10" Pipe Schedule 80 Steam/Condensate | 85 | LF | ||
| B | B12 | 8" Pipe Schedule 80 Steam/Condensate | 100 | LF | ||
| B | B13 | 6" Pipe Schedule 80 Steam/Condensate | 100 | LF | ||
| B | B14 | 5" Pipe Schedule 80 Steam/Condensate | 80 | LF | ||
| B | B15 | 4" Pipe Schedule 80 Steam/Condensate | 240 | LF | ||
| B | B16 | 2" Pipe Schedule 80 Steam/Condensate | 200 | LF | ||
| B | B17 | 1 1/2" Pipe Schedule 80 Steam/Condensate | 70 | LF | ||
| B | B18 | 1 1/4" Pipe Schedule 80 Steam/Condensate | 70 | LF | ||
| B | B19 | 12" Fitting Schedule 40 Steam/Condensate | 10 | EA | ||
| B | B20 | 10" Fitting Schedule 40 Steam/Condensate | 10 | EA | ||
| B | B21 | 8" Fitting Schedule 40 Steam/Condensate | 4 | EA | ||
| B | B22 | 6" Fitting Schedule 40 Steam/Condensate | 4 | EA | ||
| B | B23 | 5" Fitting Schedule 40 Steam/Condensate | 9 | EA | ||
| B | B24 | 4" Fitting Schedule 40 Steam/Condensate | 9 | EA | ||
| B | B25 | 2" Fitting Schedule 40 Steam/Condensate | 9 | EA | ||
| B | B26 | 1 1/2" Fitting Schedule 40 Steam/Condensate | 4 | EA | ||
| B | B27 | 1 1/4" Fitting Schedule 40 Steam/Condensate | 4 | EA | ||
| B | B28 | 12" Fitting Schedule 80 Steam/Condensate | 9 | EA | ||
| B | B29 | 10" Fitting Schedule 80 Steam/Condensate | 9 | EA | ||
| B | B30 | 8" Fitting Schedule 80 Steam/Condensate | 9 | EA | ||
| B | B31 | 6" Fitting Schedule 80 Steam/Condensate | 9 | EA | ||
| B | B32 | 5" Fitting Schedule 80 Steam/Condensate | 9 | EA | ||
| B | B33 | 4" Fitting Schedule 80 Steam/Condensate | 8 | EA | ||
| B | B34 | 2" Fitting Schedule 80 Steam/Condensate | 4 | EA | ||
| B | B35 | 1 1/2" Fitting Schedule 80 Steam/Condensate | 4 | EA | ||
| B | B36 | 1 1/4" Fitting Schedule 80 Steam/Condensate | 4 | EA | ||
| B | B37 | 12" Pipe Schedule 40 Chilled Water | 40 | LF | ||
| B | B38 | 10" Pipe Schedule 40 Chilled Water | 20 | LF | ||
| B | B39 | 8" Pipe Schedule 40 Chilled Water | 40 | LF | ||
| B | B40 | 6" Pipe Schedule 40 Chilled Water | 45 | LF | ||
| B | B41 | 5" Pipe Schedule 40 Chilled Water | 45 | LF | ||
| B | B42 | 4" Pipe Schedule 40 Chilled Water | 60 | LF | ||
| B | B43 | 2" Pipe Schedule 40 Chilled Water | 40 | LF | ||
| B | B44 | 1 1/2" Pipe Schedule 40 Chilled Water | 40 | LF | ||
| B | B45 | 1 1/4" Pipe Schedule 40 Chilled Water | 40 | LF | ||
| B | B46 | 12" Pipe Schedule 80 Chilled Water | 100 | LF | ||
| B | B47 | 10" Pipe Schedule 80 Chilled Water | 40 | LF | ||
| B | B48 | 8" Pipe Schedule 80 Chilled Water | 60 | LF | ||
| B | B49 | 6" Pipe Schedule 80 Chilled Water | 100 | LF | ||
| B | B50 | 5" Pipe Schedule 80 Chilled Water | 90 | LF | ||
| B | B51 | 4" Pipe Schedule 80 Chilled Water | 80 | LF | ||
| B | B52 | 2" Pipe Schedule 80 Chilled Water | 100 | LF | ||
| B | B53 | 1 1/2" Pipe Schedule 80 Chilled Water | 30 | LF | ||
| B | B54 | 1 1/4" Pipe Schedule 80 Chilled Water | 30 | LF | ||
| B | B55 | 12" Fitting Schedule 40 Chilled Water | 4 | EA | ||
| B | B56 | 10" Fitting Schedule 40 Chilled Water | 7 | EA | ||
| B | B57 | 8" Fitting Schedule 40 Chilled Water | 7 | EA | ||
| B | B58 | 6" Fitting Schedule 40 Chilled Water | 4 | EA | ||
| B | B59 | 5" Fitting Schedule 40 Chilled Water | 7 | EA | ||
| B | B60 | 4" Fitting Schedule 40 Chilled Water | 7 | EA | ||
| B | B61 | 2" Fitting Schedule 40 Chilled Water | 7 | EA | ||
| B | B62 | 1 1/2" Fitting Schedule 40 Chilled Water | 8 | EA | ||
| B | B63 | 1 1/4" Fitting Schedule 40 Chilled Water | 8 | EA | ||
| B | B64 | 12" Fitting Schedule 80 Chilled Water | 7 | EA | ||
| B | B65 | 10" Fitting Schedule 80 Chilled Water | 7 | EA | ||
| B | B66 | 8" Fitting Schedule 80 Chilled Water | 7 | EA | ||
| B | B67 | 6" Fitting Schedule 80 Chilled Water | 6 | EA | ||
| B | B68 | 5" Fitting Schedule 80 Chilled Water | 6 | EA | ||
| B | B69 | 4" Fitting Schedule 80 Chilled Water | 6 | EA | ||
| B | B70 | 2" Fitting Schedule 80 Chilled Water | 7 | EA | ||
| B | B71 | 1 1/2" Fitting Schedule 80 Chilled Water | 6 | EA | ||
| B | B72 | 1 1/4" Fitting Schedule 80 Chilled Water | 6 | EA | ||
| JUNCTION BOX | ||||||
| C | C01 | Replace Valve (12") | 1 | EA | ||
| C | C02 | Replace Valve (10") | 2 | EA | ||
| C | C03 | Replace Valve (8") | 2 | EA | ||
| C | C04 | Replace Valve (6") | 2 | EA | ||
| C | C05 | Replace Valve (5") | 2 | EA | ||
| C | C06 | Replace Valve (4") | 1 | EA | ||
| C | C07 | Replace Valve (3") | 2 | EA | ||
| C | C08 | Replace Valve (2") | 2 | EA | ||
| C | C09 | Replace Valve (1 1/2") | 2 | EA | ||
| C | C10 | Replace Valve (1 1/4") | 2 | EA | ||
| C | C11 | Replace Valve (1") | 2 | EA | ||
| C | C12 | Replace Valve (1/2") | 2 | EA | ||
| C | C13 | Replace Flange Gasket (12") | 2 | EA | ||
| C | C14 | Replace Flange Gasket (10") | 2 | EA | ||
| C | C15 | Replace Flange Gasket (8") | 2 | EA | ||
| C | C16 | Replace Flange Gasket (6") | 2 | EA | ||
| C | C17 | Replace Flange Gasket (5") | 4 | EA | ||
| C | C18 | Replace Flange Gasket (4") | 4 | EA | ||
| C | C19 | Replace Flange Gasket (3") | 3 | EA | ||
| C | C20 | Replace Flange Gasket (2") | 4 | EA | ||
| C | C21 | Replace Flange Gasket (1 1/2") | 3 | EA | ||
| C | C22 | Replace Flange Gasket (1 1/4") | 3 | EA | ||
| C | C23 | Replace Flange (12") | 2 | EA | ||
| C | C24 | Replace Flange (10") | 3 | EA | ||
| C | C25 | Replace Flange (8") | 3 | EA | ||
| C | C26 | Replace Flange (6") | 2 | EA | ||
| C | C27 | Replace Flange (5") | 2 | EA | ||
| C | C28 | Replace Flange (4") | 3 | EA | ||
| C | C29 | Replace Flange (3") | 3 | EA | ||
| C | C30 | Replace Flange (2") | 4 | EA | ||
| C | C31 | Replace Flange (1 1/2") | 3 | EA | ||
| C | C32 | Replace Flange (1 1/4") | 2 | EA | ||
| C | C33 | Provide Gear Actuator(valves 6" and Larger) | 2 | EA | ||
| C | C34 | Insulate 1 1/2" fitting including Aluminum Jacket | 4 | EA | ||
| C | C35 | Insulate 2" fitting including Aluminum Jacket | 4 | EA | ||
| C | C36 | Insulate 3" fitting including Aluminum Jacket | 3 | EA | ||
| C | C37 | Insulate 4" fitting including Aluminum Jacket | 3 | EA | ||
| C | C38 | Insulate 5" fitting including Aluminum Jacket | 4 | EA | ||
| C | C39 | Insulate 6" fitting including Aluminum Jacket | 5 | EA | ||
| C | C40 | Insulate 8" fitting including Aluminum Jacket | 4 | EA | ||
| C | C41 | Insulate10" fitting including Aluminum Jacket | 4 | EA | ||
| C | C42 | Insulate 12" fitting including Aluminum Jacket | 5 | EA | ||
| C | C43 | Remove & Replace high pressure drip valve | 4 | EA | ||
| C | C44 | Remove & Replace bypass valve 1" | 4 | EA | ||
| C | C45 | Remove & Replace check valve 1" | 2 | EA | ||
| C | C46 | Remove & Replace steam valve 1" | 3 | EA | ||
| C | C47 | Remove & Replace globe valve 1" | 3 | EA | ||
| C | C48 | Remove & Replace bucket trap | 3 | EA | ||
| C | C49 | Remove & Replace gate valve blow off | 3 | EA | ||
| C | C50 | Remove & Replace strainer | 3 | EA | ||
| C | C51 | Remove & Replace Drip leg and fittings | 3 | EA | ||
| C | C52 | Remove & Replace Fin pipe radiator, 4' long, 4-1/2" fins | 3 | EA | ||
| C | C53 | Remove & Replace cooling control valve. | 2 | EA | ||
| C | C54 | Remove & Replace 2" vent w/ gooseneck | 2 | EA | ||
| C | C55 | Remove & Replace 6" vent and hood | 3 | EA | ||
| C | C56 | Remove & Replace condensate valve | 2 | EA | ||
| C | C57 | Remove & Replace bypass valve | 4 | EA | ||
| C | C58 | Remove & Replace check valve | 4 | EA | ||
| C | C59 | Remove & Replace steam valve | 4 | EA | ||
| C | C60 | Remove & Replace globe valve | 4 | EA | ||
| C | C61 | Remove & Replace bucket trap | 4 | EA | ||
| C | C62 | Remove & Replace gate valve blow off | 5 | EA | ||
| C | C63 | Remove & Replace strainer | 10 | EA | ||
| C | C64 | Remove & Replace High Pressure Orphic Trap w/ bucket trap | 1 | EA | ||
| C | C65 | Insulate 1 1/2" valve | 4 | EA | ||
| C | C66 | Insulate 2" valve | 4 | EA | ||
| C | C67 | Insulate 3" valve | 2 | EA | ||
| C | C68 | Insulate 4" valve | 2 | EA | ||
| C | C69 | Insulate 5" valve | 2 | EA | ||
| C | C70 | Insulate 6" valve | 2 | EA | ||
| C | C71 | Insulate 8" valve | 2 | EA | ||
| C | C72 | Insulate10" valve | 2 | EA | ||
| C | C73 | Insulate 12" valve | 2 | EA | ||
| C | C74 | Remove and Replace Steam Trap | 2 | EA | ||
| C | C75 | Remove and Replace Electric Ejector Pump | 2 | EA | ||
| C | C76 | Remove and Replace Steam Ejector Pump | 1 | EA | ||
| C | C77 | New sump pump in trench at high ground water location. | 2 | EA | ||
| C | C78 | Remove & Replace 1-1/2" Drain | 2 | EA | ||
| C | C79 | Remove & Replace Siphon | 2 | EA | ||
| C | C80 | Remove & Replace In-line strainer | 2 | EA | ||
| C | C81 | Remove & Replace Pipe strainer at bottom sump pit (Foot Valve) | 3 | EA | ||
| C | C82 | Remove & Replace 1-1/2" Weld-O-Let | 2 | EA | ||
| C | C83 | Remove & Replace Snap valve with bleed-off | 3 | EA | ||
| C | C84 | Remove & Replace 2'x2' Metal Grate 1"x1/4" at sump pit | 2 | EA | ||
| C | C85 | Replace Discharge Diffuser at Condensate Line connection. | 3 | EA | ||
| C | C86 | 1 1/2" Valve Access Cover | 2 | EA | ||
| C | C87 | 2" Valve Access Cover | 2 | EA | ||
| C | C88 | 3" Valve Access Cover | 2 | EA | ||
| C | C89 | 4" Valve Access Cover | 2 | EA | ||
| C | C90 | 5" Valve Access Cover | 2 | EA | ||
| C | C91 | 6" Valve Access Cover | 2 | EA | ||
| C | C92 | 8" Valve Access Cover | 2 | EA | ||
| C | C93 | 10" Valve Access Cover | 3 | EA | ||
| C | C94 | 12" Valve Access Cover | 3 | EA | ||
| TRENCHES | ||||||
| D | D01 | Replace 2" Pipe Hangers and Rollers Assembly | 5 | EA | ||
| D | D02 | Replace 3" Pipe Hangers and Rollers Assembly | 7 | EA | ||
| D | D03 | Replace 4" Pipe Hangers and Rollers Assembly | 5 | EA | ||
| D | D04 | Replace 5" Pipe Hangers and Rollers Assembly | 7 | EA | ||
| D | D05 | Replace 6" Pipe Hangers and Rollers Assembly | 5 | EA | ||
| D | D06 | Replace 8" Pipe Hangers and Rollers Assembly | 7 | EA | ||
| D | D07 | Replace 10" Pipe Hangers and Rollers Assembly | 8 | EA | ||
| D | D08 | Replace 12" Pipe Hangers and Rollers Assembly | 5 | EA | ||
| D | D09 | Replace Threaded rod @ Hardware for 2" Pipe Hangers / Rollers | 10 | EA | ||
| D | D10 | Replace Threaded rod @ Hardware for 3" Pipe Hangers / Rollers | 9 | EA | ||
| D | D11 | Replace Threaded rod @ Hardware for 4"Pipe Hangers / Rollers | 5 | EA | ||
| D | D12 | Replace Threaded rod @ Hardware for 5" Pipe Hangers / Rollers | 6 | EA | ||
| D | D13 | Replace Threaded rod @ Hardware for 6" Pipe Hangers / Rollers | 10 | EA | ||
| D | D14 | Replace Threaded rod @ Hardware for 8" Pipe Hangers / Rollers | 9 | EA | ||
| D | D15 | Replace Threaded rod @ Hardware for 10" Pipe Hangers/Rollers | 10 | EA | ||
| D | D16 | Replace Threaded rod @ Hardware for 12" Pipe Hangers/Rollers | 10 | EA | ||
| D | D17 | Replace 4" Pipe Anchor | 5 | EA | ||
| D | D18 | Replace 5" Pipe Anchor | 5 | EA | ||
| D | D19 | Replace 6" Pipe Anchor | 5 | EA | ||
| D | D20 | Replace 8" Pipe Anchor | 5 | EA | ||
| D | D21 | Replace 10" Pipe Anchor | 5 | EA | ||
| D | D22 | Replace 3" Pipe Anchor Band | 5 | EA | ||
| D | D23 | Replace 6" Pipe Anchor Band | 5 | EA | ||
| D | D24 | Replace 3" Pipe Anchor plate | 5 | EA | ||
| D | D25 | Replace 6" Pipe Anchor plate | 5 | EA | ||
| D | D26 | Replace Pipe Support 1-1/2" through 4" | 5 | EA | ||
| D | D27 | Replace Pipe Support 5" through 12" | 5 | EA | ||
| D | D28 | Replace Suspension Rod | 5 | EA | ||
| D | D29 | Replace Pipe Alignment Guide 2" through 14" | 5 | EA | ||
| D | D30 | Install 5" Pipe Saddle | 5 | EA | ||
| D | D31 | Install 6" Pipe Saddle | 5 | EA | ||
| D | D32 | Remove/Reinstall/Reseal Concrete Trench Cover | 4 | EA | ||
| D | D33 | Provide and Install New Reinforced Concrete Trench Cover, 4'W x 3'L x 9"D, with embedded lift pins (match exg). Actual size vary to fit field conditions (at roadways with raiting not less than H20 Truck Load). | 4 | EA | ||
| D | D34 | Provide and Install New Reinforced Concrete Trench Cover, 4'W x 3'L x 6"D, with embedded lift pins (match exg). Actual size vary to fit field conditions (at sidewalks). | 4 | EA | ||
| D | D35 | Patch Concrete where deteriorated at top edge of Conc trench. | 40 | LF | ||
| D | D36 | Remove exg deteriorated L4x4x +/-4’-0” angle pipe support; Provide and install new galv L4x4 angle. | 100 | LF | ||
| D | D37 | At Drip Leg / Steam Ejector: Remove trench cap support beam, W8x31x +/-5’-5” ; Provide and install new support beam and end bearing angles. Paint with rust proof primer. | 1 | EA | ||
| D | D38 | At Expansion Loop: Remove trench cap support beam, W8x48x +/-9’-8” ; Provide and install new galv support beam and end bearing angles. | 2 | EA | ||
| D | D39 | At Expansion Loop: Remove trench cap support beam, W8x31x +/-4’-7” ; Provide and install new support beam. Paint with rust proof primer. | 2 | EA | ||
| D | D40 | At Junction Box: Remove exg cap support beam, W8x48x +/-7’-6”; Provide and install new support beam and end bearing angles. Paint with rust proof primer. | 3 | EA | ||
| D | D41 | At Junction Box: Remove exg cap support beam, W8x48x +/-4’-0”; Provide and install new galv support beam. | 3 | EA | ||
| SITE WORK | ||||||
| E | E01 | Steel Plates for road trench cover to support vehicular traffic. | 6 | EA | ||
| E | E02 | Fencing 6' w/ brown fabric covering | 600 | LF | ||
| E | E03 | Remove & replace Granite Curb | 200 | LF | ||
| E | E04 | Remove, Dispose of & Replace Bituminous Conc. Curb | 200 | LF | ||
| E | E05 | Remove, Dispose of & Replace Concrete Curb | 200 | LF | ||
| E | E06 | Remove, Dispose of & Replace Concrete Sidewalk | 200 | CY | ||
| E | E07 | Remove, Dispose of & Replace Bituminous Sidewalk | 200 | CY | ||
| E | E08 | Excavate and Repave Direct Burial of Concrete Trench Cover under 5" pavement. | 100 | CY | ||
| E | E09 | Excavate for Direct Burial of Concrete Trench Cover under 6" of Grass area | 200 | CY | ||
| E | E10 | Remove and stockpile Topsoil | 100 | SY | ||
| E | E11 | Place topsoil back in original locations | 200 | SY | ||
| E | E12 | Provide and spread Loam | 1,000 | CY | ||
| E | E13 | Spread Fertilizer | 2,000 | SY | ||
| E | E14 | Spread Lime | 1,000 | SY | ||
| E | E15 | Spread Grass Seeds | 30 | LB | ||
| E | E16 | Spread Hydro Grass Seed | 7,000 | SF | ||
| E | E17 | Sedimentation Control Bale Barrier | 20 | LF | ||
| E | E18 | Ordinary Borrow | 100 | CY | ||
| E | E19 | Gravel Borrow | 100 | CY | ||
| E | E20 | Gravel Base | 100 | CY | ||
| E | E21 | Crushed Stone | 100 | CY | ||
| E | E22 | Sand Borrow | 80 | CY | ||
| E | E23 | Removal & disposal of excess excavation material | 200 | CY | ||
| E | E24 | Saw Cut Bit. Pavement | 50 | LF | ||
| E | E25 | Test Pit Excavation | 30 | CY | ||
| E | E26 | New drywell adjacent to new sump pump. Include related piping. | 1 | EA | ||
| E | E27 | Provide Traffic Sign | 8 | EA | ||
| E | E28 | Jersey Barriers with 3' fence | 300 | LF | ||
| E | E29 | Excavate for Direct Burial Pipe (Double) | 480 | CY | ||
| E | E30 | Excavate for Direct Burial Pipe (Single) | 480 | CY | ||
| E | E31 | Trench Shoring 4 to 8 feet | 200 | LF | ||
| E | E32 | Trench Shoring 8 and above | 200 | LF | ||
| WATER | ||||||
| F | F01 | Copper pipe, 1/2" diameter | 100 | LF | ||
| F | F02 | Copper pipe, 3/4" diameter | 100 | LF | ||
| F | F03 | Copper pipe, 1" diameter | 200 | LF | ||
| F | F04 | Copper pipe, 1 1/2" diameter | 80 | LF | ||
| F | F05 | Copper pipe, 2" diameter | 200 | LF | ||
| F | F06 | Service connection, Size <= 1 1/2" | 4 | EA | ||
| F | F07 | Service connection, 1-1/2" > Size <= 2 1/2" | 4 | EA | ||
| F | F08 | Service connection, Size > 2 1/2" | 4 | EA | ||
| F | F09 | Ductile iron pipe, 4" diameter | 200 | LF | ||
| F | F10 | Ductile iron pipe, 6" diameter | 100 | LF | ||
| F | F11 | Ductile iron pipe, 8" diameter | 100 | LF | ||
| F | F12 | Ductile iron pipe, 10" diameter | 80 | LF | ||
| F | F13 | Ductile iron pipe, 12" diameter | 80 | LF | ||
| F | F14 | Ductile iron pipe, 16" diameter | 40 | LF | ||
| F | F15 | Hose bib, up to 1 1/2" diameter | 10 | EA | ||
| F | F16 | Ball valve, 1/2" to 1" diameter | 4 | EA | ||
| F | F17 | Ball valve, 1 1/2" to 2" diameter | 4 | EA | ||
| F | F18 | Curb stop valve, 3/4" diameter | 10 | EA | ||
| F | F19 | Curb stop valve, 1" diameter | 4 | EA | ||
| F | F20 | Curb stop valve, 1 1/2" diameter | 10 | EA | ||
| F | F21 | Curb stop valve, 2" diameter | 4 | EA | ||
| F | F22 | Water gate valve, 2" diameter | 4 | EA | ||
| F | F23 | Water gate valve, 3" diameter | 4 | EA | ||
| F | F24 | Water gate valve, 4" diameter | 4 | EA | ||
| F | F25 | Water gate valve, 6" diameter | 4 | EA | ||
| F | F26 | Water gate valve, 8" diameter | 4 | EA | ||
| F | F27 | Water gate valve, 10" diameter | 4 | EA | ||
| F | F28 | Water gate valve, 12" diameter | 4 | EA | ||
| F | F29 | Water gate valve, 16" diameter | 4 | EA | ||
| F | F30 | Post indicator valve, 6" diameter | 4 | EA | ||
| F | F31 | Post indicator valve, 8" diameter | 4 | EA | ||
| F | F32 | Water gate casting and cover | 5 | VF | ||
| F | F33 | Ductile iron fitting, 4" diameter | 3 | EA | ||
| F | F34 | Ductile iron fitting, 6" diameter | 3 | EA | ||
| F | F35 | Ductile iron fitting, 8" diameter | 3 | EA | ||
| F | F36 | Ductile iron fitting, 10" diameter | 3 | EA | ||
| F | F37 | Ductile iron fitting, 12" diameter | 3 | EA | ||
| F | F38 | Ductile iron fitting, 16" diameter | 3 | EA | ||
| F | F39 | Pipe coupling, 3" dia | 3 | EA | ||
| F | F40 | Pipe coupling, 4" dia | 3 | EA | ||
| F | F41 | Pipe coupling, 6" dia | 3 | EA | ||
| F | F42 | Pipe coupling, 8" dia | 3 | EA | ||
| F | F43 | Pipe coupling, 10" dia | 3 | EA | ||
| F | F44 | Pipe coupling, 12" dia | 3 | EA | ||
| F | F45 | Pipe coupling, 16" dia | 3 | EA | ||
| F | F46 | Drill and tap unpressurized main ("dry tap") <=8" | 3 | EA | ||
| F | F47 | Drill and tap unpressurized main ("dry tap") > 8" | 3 | EA | ||
| F | F48 | Drill and tap pressurized main ("wet tap") <=8" | 3 | EA | ||
| F | F49 | Drill and tap pressurized main ("wet tap") > 8" | 3 | EA | ||
| F | F50 | Pressure testing, sanitizing and lab analysis | 3 | EA | ||
| F | F51 | Fire hydrant | 3 | EA | ||
| F | F52 | Relocate fire hydrant | 4 | EA | ||
| F | F53 | 6" Fire Hydrant Extension Kit | 3 | EA | ||
| F | F54 | 12" Fire Hydrant Extension Kit | 3 | EA | ||
| F | F55 | 18" Fire Hydrant Extension Kit | 3 | EA | ||
| F | F56 | 24" Fire Hydrant Extension Kit | 3 | EA | ||
| F | F57 | Temporary By-Pass Piping | 400 | LF | ||
| SANITARY SEWER | ||||||
| G | G01 | Clean and inspect sewer lines 12" and under | 240 | LF | ||
| G | G02 | Clean and inspect sewer lines over 12" | 200 | LF | ||
| G | G03 | PVC sewer pipe, 4" | 100 | LF | ||
| G | G04 | PVC sewer pipe, 6" | 100 | LF | ||
| G | G05 | PVC sewer pipe, 8" | 100 | LF | ||
| G | G06 | PVC sewer pipe, 10" | 200 | LF | ||
| G | G07 | PVC sewer pipe, 12" | 400 | LF | ||
| G | G08 | PVC sewer pipe, 15" | 40 | LF | ||
| G | G09 | PVC sewer pipe, 18" | 400 | LF | ||
| G | G10 | PVC service connection, 4" | 60 | LF | ||
| G | G11 | PVC service connection, 6" | 4 | LF | ||
| G | G12 | PVC service connection, 8" | 4 | LF | ||
| G | G13 | PVC wye/tee connection, 4" | 5 | EA | ||
| G | G14 | PVC wye/tee connection, 6" | 5 | EA | ||
| G | G15 | PVC wye/tee connection, 8" | 5 | EA | ||
| G | G16 | PVC wye/tee connection, 10" | 5 | EA | ||
| G | G17 | PVC wye/tee connection, 12" | 4 | EA | ||
| G | G18 | PVC wye/tee connection, 15" | 5 | EA | ||
| G | G19 | PVC wye/tee connection, 18" | 4 | EA | ||
| G | G20 | PVC Chimney, 4" | 2 | VF | ||
| G | G21 | PVC Chimney, 5" | 2 | VF | ||
| G | G22 | PVC Chimney, 6" | 2 | VF | ||
| G | G23 | Resinous liner, 6" | 20 | LF | ||
| G | G24 | Resinous liner, 8" | 20 | LF | ||
| G | G25 | Resinous liner, 10" | 20 | LF | ||
| G | G26 | Resinous liner, 12" | 20 | LF | ||
| G | G27 | Resinous liner, 15" | 20 | LF | ||
| G | G28 | Resinous liner, 18" | 20 | LF | ||
| G | G29 | Pipe bursting, 6" | 20 | LF | ||
| G | G30 | Pipe bursting, 8" | 20 | LF | ||
| G | G31 | Pipe bursting, 10" | 20 | LF | ||
| G | G32 | Pipe bursting, 12" | 20 | LF | ||
| G | G33 | Pipe bursting, 15" | 20 | LF | ||
| G | G34 | Pipe bursting, 18" | 20 | LF | ||
| G | G35 | Drop connection, any size | 20 | LF | ||
| G | G36 | Tree root removal | 20 | LF | ||
| G | G37 | Clean sewer manhole | 5 | EA | ||
| G | G38 | Repair structure - trough | 20 | EA | ||
| G | G39 | Sewer manhole, 4' diameter | 3 | VF | ||
| G | G40 | Sewer manhole, 5' diameter | 3 | VF | ||
| G | G41 | Sewer manhole, 6' diameter | 3 | VF | ||
| STORM DRAINAGE | ||||||
| H | H01 | Catchbasin/manhole, 4' diameter | 1 | VF | ||
| H | H02 | Catchbasin/manhole, 5' diameter | 1 | VF | ||
| H | H03 | Catchbasin/manhole, 6' diameter | 1 | VF | ||
| H | H04 | Catchbasin casting and cover | 3 | EA | ||
| H | H05 | Manhole casting and cover | 3 | EA | ||
| H | H06 | Clean and adjust structure | 3 | EA | ||
| H | H07 | Deepen structure | 1 | VF | ||
| H | H08 | Repair structure | 1 | VF | ||
| H | H09 | Reinforced concrete pipe, 12" dia | 10 | LF | ||
| H | H10 | Reinforced concrete pipe, 18" dia | 10 | LF | ||
| H | H11 | Reinforced concrete pipe, 24" dia | 10 | LF | ||
| H | H12 | PVC drain pipe, 6" dia | 30 | LF | ||
| H | H13 | PVC drain pipe, 8" dia | 30 | LF | ||
| H | H14 | PVC drain pipe, 12" dia | 20 | LF | ||
| H | H15 | PVC drain pipe, 15" dia | 10 | LF | ||
| H | H16 | PVC drain pipe, 18" dia | 10 | LF | ||
| H | H17 | PVC drain pipe, 21" dia | 20 | LF | ||
| H | H18 | PVC drain pipe, 24" dia | 20 | LF | ||
| H | H19 | Foundation drain, 4” diameter | 100 | LF | ||
| H | H20 | Foundation drain, 6” diameter | 80 | LF | ||
| H | H21 | Foundation drain, 8” diameter | 80 | LF | ||
| H | H22 | Existing storm drain pipe cleaning | 300 | LF | ||
| H | H23 | Existing storm structure cleaning | 4 | EA | ||
| ELECTRIC/COMM | ||||||
| J | J01 | Install GRS Conduit < 1" | 10 | LF | ||
| J | J02 | Install GRS Conduit 1" - 2" | 40 | LF | ||
| J | J03 | Install GRS Conduit > 2" | 80 | LF | ||
| J | J04 | Remove GRS Conduit < 1" | 20 | LF | ||
| J | J05 | Remove GRS Conduit 1" - 2" | 20 | LF | ||
| J | J06 | Remove GRS Conduit > 2" | 20 | LF | ||
| J | J07 | Remove PVC Conduit < 1" | 20 | LF | ||
| J | J08 | Remove PVC Conduit 1" - 2" | 20 | LF | ||
| J | J09 | Remove PVC Conduit > 2" | 20 | LF | ||
| J | J10 | Install PVC Conduit < 1" | 60 | LF | ||
| J | J11 | Install PVC Conduit 1" - 2" | 80 | LF | ||
| J | J12 | Install PVC Conduit > 2" | 100 | LF | ||
| J | J13 | Trap Monitor and Transmitter | 4 | EA | ||
| J | J14 | Trap Monitor Relay | 4 | EA | ||
| J | J15 | #14 Wire | 400 | LF | ||
| J | J16 | #12 Wire | 600 | LF | ||
| J | J17 | #10 Wire | 600 | LF | ||
| J | J18 | #8 Wire | 200 | LF | ||
| MECHANICAL ROOMS | ||||||
| K | K01 | Asbestos Abatement 10" Pipe | 100 | LF | ||
| K | K02 | Asbestos Abatement 8" Pipe | 80 | LF | ||
| K | K03 | Asbestos Abatement 6" Pipe | 20 | LF | ||
| K | K04 | Asbestos Abatement 5" Pipe | 20 | LF | ||
| K | K05 | Asbestos Abatement 4" Pipe | 80 | LF | ||
| K | K06 | Asbestos Abatement 2" Pipe | 60 | LF | ||
| K | K07 | Asbestos Abatement 1 1/2" Pipe | 20 | LF | ||
| K | K08 | Asbestos Abatement 1 1/4" Pipe | 60 | LF | ||
| K | K09 | Remove existing flash tank. | 3 | EA | ||
| K | K10 | Provide and install new flash tank. | 3 | EA | ||
| K | K11 | Remove existing condensate receiver pump. | 4 | EA | ||
| K | K12 | Provide and install new condensate receiver pump. | 4 | EA | ||
| K | K13 | Insulate Heat Exchanger | 4 | EA | ||
| K | K14 | Insulate flash tank | 4 | EA | ||
| K | K15 | Insulate 1 1/2" Pipe | 100 | LF | ||
| K | K17 | Insulate 2" Pipe | 400 | LF | ||
| K | K18 | Insulate 3" Pipe | 100 | LF | ||
| K | K19 | Insulate 4" Pipe | 400 | LF | ||
| K | K20 | Insulate 5" Pipe | 100 | LF | ||
| K | K21 | Insulate 6" Pipe | 400 | LF | ||
| K | K22 | Insulate 8" Pipe | 100 | LF | ||
| K | K23 | Insulate10" Pipe | 100 | LF | ||
| K | K24 | Insulate Fitting (6") | 15 | EA | ||
| K | K25 | Insulate Fitting (4") | 15 | EA | ||
| K | K26 | Insulate Fitting (3") | 15 | EA | ||
| K | K27 | Insulate Fitting (2") | 15 | EA | ||
| K | K28 | Insulate Fitting (1 1/2") | 15 | EA | ||
| K | K29 | Insulate Fitting (1") | 15 | EA | ||
| K | K30 | Insulate Fitting (3/4") | 15 | EA | ||
| K | K31 | Insulate Fitting (1/2") | 15 | EA | ||
| K | K32 | Insulate Valve (6") | 15 | EA | ||
| K | K33 | Insulate Valve (4") | 15 | EA | ||
| K | K34 | Insulate Valve (3") | 15 | EA | ||
| K | K35 | Insulate Valve (2") | 15 | EA | ||
| K | K36 | Insulate Valve (1 1/2") | 15 | EA | ||
| K | K37 | Insulate Valve (1") | 15 | EA | ||
| K | K38 | Insulate Valve (3/4") | 10 | EA | ||
| K | K39 | Insulate Valve (1/2") | 10 | EA | ||
| K | K40 | Provide wrap around & strap on Pipe Markers 1 1/2" | 5 | EA | ||
| K | K41 | Provide wrap around & strap on Pipe Markers 2" | 20 | EA | ||
| K | K42 | Provide wrap around & strap on Pipe Markers 3" | 10 | EA | ||
| K | K43 | Provide wrap around & strap on Pipe Markers 4" | 20 | EA | ||
| K | K44 | Provide wrap around & strap on Pipe Markers 5" | 5 | EA | ||
| K | K45 | Provide wrap around & strap on Pipe Markers 6" | 4 | EA | ||
| K | K46 | Provide wrap around & strap on Pipe Markers 8" | 5 | EA | ||
| K | K47 | Provide wrap around & strap on Pipe Markers 10" | 5 | EA | ||
| K | K48 | Install Dosing Pot | 5 | EA | ||
| K | K49 | Replace Valve (12") | 10 | EA | ||
| K | K50 | Replace Valve (10") | 10 | EA | ||
| K | K51 | Replace Valve (8") | 10 | EA | ||
| K | K52 | Replace Valve (6") | 40 | EA | ||
| K | K53 | Replace Valve (5") | 10 | EA | ||
| K | K54 | Replace Valve (4") | 8 | EA | ||
| K | K55 | Replace Valve (3") | 6 | EA | ||
| K | K56 | Replace Valve (2") | 8 | EA | ||
| K | K57 | Replace Valve (1 1/2") | 6 | EA | ||
| K | K58 | Replace Valve (1 1/4") | 6 | EA | ||
| K | K59 | Replace Valve (1") | 15 | EA | ||
| K | K60 | Replace Valve (1/2") | 12 | EA | ||
| K | K61 | Replace Flange Gasket (12") | 6 | EA | ||
| K | K62 | Replace Flange Gasket (10") | 9 | EA | ||
| K | K63 | Replace Flange Gasket (8") | 10 | EA | ||
| K | K64 | Replace Flange Gasket (6") | 15 | EA | ||
| K | K65 | Replace Flange Gasket (5") | 12 | EA | ||
| K | K66 | Replace Flange Gasket (4") | 15 | EA | ||
| K | K67 | Replace Flange Gasket (3") | 12 | EA | ||
| K | K68 | Replace Flange Gasket (2") | 15 | EA | ||
| K | K69 | Replace Flange Gasket (1 1/2") | 15 | EA | ||
| K | K70 | Replace Flange Gasket (1 1/4") | 15 | EA | ||
| K | K71 | Replace Flange (12") | 15 | EA | ||
| K | K72 | Replace Flange (10") | 15 | EA | ||
| K | K73 | Replace Flange (8") | 15 | EA | ||
| K | K74 | Replace Flange (6") | 15 | EA | ||
| K | K75 | Replace Flange (5") | 15 | EA | ||
| K | K76 | Replace Flange (4") | 15 | EA | ||
| K | K77 | Replace Flange (3") | 15 | EA | ||
| K | K78 | Replace Flange (2") | 15 | EA | ||
| K | K79 | Replace Flange (1 1/2") | 10 | EA | ||
| K | K80 | Replace Flange (1 1/4") | 10 | EA | ||
| K | K81 | Prepare Asbestos Removal Plan | 10 | EA | ||
| TEMPORARY HEAT | ||||||
| L | L01 | Temporary Piping 1 1/2" | 50 | LF | ||
| L | L02 | Temporary Piping 2" | 100 | LF | ||
| L | L03 | Temporary Piping 3" | 50 | LF | ||
| L | L04 | Temporary Piping 4" | 100 | LF | ||
| L | L05 | Temporary Piping 5" | 50 | LF | ||
| L | L06 | Temporary Piping 6" | 100 | LF | ||
| L | L07 | Temporary Piping 8" | 50 | LF | ||
| MISCELLANEOUS | ||||||
| M | M01 | Manufacturer Commissioning and Certification | 4 | EA | ||
| M | M02 | Clean Trench | 1,000 | LF | ||
| M | M03 | Mobilization & Demobilization No Excavation Required | 4 | EA | ||
| M | M04 | Mobilization & Demobilization Excavation Required | 6 | EA | ||
| M | M05 | Red Lines | 100 | HR | ||
| M | M06 | Record Drawings | 100 | HR | ||
| Line Item Total: | $0.00 | |||||
| Coefficients | ||||||
| Hanscom AFB | 0.00% | $0.00 | ||||
| Premium Time | 0.00% | $0.00 |
Sub-Total incl. Coefficients $0.00
| Overhead | 0.00% | $0.00 |
| G&A | 0.00% | $0.00 |
| Other Direct Cost | 0.00% | $0.00 |
| Bond | 0.00% | $0.00 |
| Profit | 0.00% | $0.00 |
Project Total $0.00
&"Arial,Bold"&14Steam and Condensate IDIQ &D &"Arial,Bold"&14FY2015 Contract (5 Year Ordering Period) Period 01 - 15 Sep 15 - 30 Sep 16 (Contractor)
&12Page &P of &N
BID (2)
| Sub Sch | Line No. | DESCRIPTION | ESTIMATED | |
| QUANTITY | UM | UNIT | ||
| PRICE | ESTIMATED |
TOTAL
| PIPES & FITTINGS IN CONCRETE TRENCHES | ||||||
| A | A01 | Replace Pipe (12") Schedule 40 | 100 | LF | ||
| A | A02 | Replace Pipe (10") Schedule 40 | 20 | LF | ||
| A | A03 | Replace Pipe (8") Schedule 40 | 40 | LF | ||
| A | A04 | Replace Pipe (6") Schedule 40 | 40 | LF | ||
| A | A05 | Replace Pipe (5") Schedule 40 | 20 | LF | ||
| A | A06 | Replace Pipe (4") Schedule 40 | 80 | LF | ||
| A | A07 | Replace Pipe (3") Schedule 40 | 20 | LF | ||
| A | A08 | Replace Pipe (2") Schedule 40 | 100 | LF | ||
| A | A09 | Replace Fitting (12") Schedule 40 | 10 | EA | ||
| A | A10 | Replace Fitting (10") Schedule 40 | 10 | EA | ||
| A | A11 | Replace Fitting (8") Schedule 40 | 10 | EA | ||
| A | A12 | Replace Fitting (6") Schedule 40 | 10 | EA | ||
| A | A13 | Replace Fitting (5") Schedule 40 | 10 | EA | ||
| A | A14 | Replace Fitting (4") Schedule 40 | 10 | EA | ||
| A | A15 | Replace Fitting (3") Schedule 40 | 10 | EA | ||
| A | A16 | Replace Fitting (2") Schedule 40 | 10 | EA | ||
| A | A17 | Replace Pipe (12") Schedule 80 | 100 | LF | ||
| A | A18 | Replace Pipe (10") Schedule 80 | 80 | LF | ||
| A | A19 | Replace Pipe (8") Schedule 80 | 80 | LF | ||
| A | A20 | Replace Pipe (6") Schedule 80 | 100 | LF | ||
| A | A21 | Replace Pipe (5") Schedule 80 | 80 | LF | ||
| A | A22 | Replace Pipe (4") Schedule 80 | 20 | LF | ||
| A | A23 | Replace Pipe (3") Schedule 80 | 60 | LF | ||
| A | A24 | Replace Pipe (2") Schedule 80 | 100 | LF | ||
| A | A25 | Replace Fitting (12") Schedule 80 | 10 | EA | ||
| A | A26 | Replace Fitting (10") Schedule 80 | 10 | EA | ||
| A | A27 | Replace Fitting (8") Schedule 80 | 10 | EA | ||
| A | A28 | Replace Fitting (6") Schedule 80 | 10 | EA | ||
| A | A29 | Replace Fitting (5") Schedule 80 | 10 | EA | ||
| A | A30 | Replace Fitting (4") Schedule 80 | 10 | EA | ||
| A | A31 | Replace Fitting (3") Schedule 80 | 10 | EA | ||
| A | A32 | Replace Fitting (2") Schedule 80 | 10 | EA | ||
| A | A33 | Remove/Insulate 1 1/2" Pipe including Aluminum Jacket | 200 | LF | ||
| A | A34 | Remove/Insulate 2" Pipe including Aluminum Jacket | 240 | LF | ||
| A | A35 | Remove/Insulate 3" Pipe including Aluminum Jacket | 200 | LF | ||
| A | A36 | Remove/Insulate 4" Pipe including Aluminum Jacket | 220 | LF | ||
| A | A37 | Remove/Insulate 5" Pipe including Aluminum Jacket | 200 | LF | ||
| A | A38 | Remove/Insulate 6" Pipe including Aluminum Jacket | 220 | LF | ||
| A | A39 | Remove/Insulate 8" Pipe including Aluminum Jacket | 240 | LF | ||
| A | A40 | Remove/Insulate 10" Pipe including Aluminum Jacket | 240 | LF | ||
| A | A41 | Remove/Insulate 12" Pipe including Aluminum Jacket | 200 | LF | ||
| PIPES & FITTINGS DIRECT BURIED | ||||||
| B | B01 | 12" Pipe Schedule 40 Steam/Condensate | 60 | LF | ||
| B | B02 | 10" Pipe Schedule 40 Steam/Condensate | 80 | LF | ||
| B | B03 | 8" Pipe Schedule 40 Steam/Condensate | 200 | LF | ||
| B | B04 | 6" Pipe Schedule 40 Steam/Condensate | 40 | LF | ||
| B | B05 | 5" Pipe Schedule 40 Steam/Condensate | 40 | LF | ||
| B | B06 | 4" Pipe Schedule 40 Steam/Condensate | 200 | LF | ||
| B | B07 | 2" Pipe Schedule 40 Steam/Condensate | 100 | LF | ||
| B | B08 | 1 1/2" Pipe Schedule 40 Steam/Condensate | 80 | LF | ||
| B | B09 | 1 1/4" Pipe Schedule 40 Steam/Condensate | 80 | LF | ||
| B | B10 | 12" Pipe Schedule 80 Steam/Condensate | 80 | LF | ||
| B | B11 | 10" Pipe Schedule 80 Steam/Condensate | 85 | LF | ||
| B | B12 | 8" Pipe Schedule 80 Steam/Condensate | 100 | LF | ||
| B | B13 | 6" Pipe Schedule 80 Steam/Condensate | 100 | LF | ||
| B | B14 | 5" Pipe Schedule 80 Steam/Condensate | 80 | LF | ||
| B | B15 | 4" Pipe Schedule 80 Steam/Condensate | 240 | LF | ||
| B | B16 | 2" Pipe Schedule 80 Steam/Condensate | 200 | LF | ||
| B | B17 | 1 1/2" Pipe Schedule 80 Steam/Condensate | 70 | LF | ||
| B | B18 | 1 1/4" Pipe Schedule 80 Steam/Condensate | 70 | LF | ||
| B | B19 | 12" Fitting Schedule 40 Steam/Condensate | 10 | EA | ||
| B | B20 | 10" Fitting Schedule 40 Steam/Condensate | 10 | EA | ||
| B | B21 | 8" Fitting Schedule 40 Steam/Condensate | 4 | EA | ||
| B | B22 | 6" Fitting Schedule 40 Steam/Condensate | 4 | EA | ||
| B | B23 | 5" Fitting Schedule 40 Steam/Condensate | 9 | EA | ||
| B | B24 | 4" Fitting Schedule 40 Steam/Condensate | 9 | EA | ||
| B | B25 | 2" Fitting Schedule 40 Steam/Condensate | 9 | EA | ||
| B | B26 | 1 1/2" Fitting Schedule 40 Steam/Condensate | 4 | EA | ||
| B | B27 | 1 1/4" Fitting Schedule 40 Steam/Condensate | 4 | EA | ||
| B | B28 | 12" Fitting Schedule 80 Steam/Condensate | 9 | EA | ||
| B | B29 | 10" Fitting Schedule 80 Steam/Condensate | 9 | EA | ||
| B | B30 | 8" Fitting Schedule 80 Steam/Condensate | 9 | EA | ||
| B | B31 | 6" Fitting Schedule 80 Steam/Condensate | 9 | EA | ||
| B | B32 | 5" Fitting Schedule 80 Steam/Condensate | 9 | EA | ||
| B | B33 | 4" Fitting Schedule 80 Steam/Condensate | 8 | EA | ||
| B | B34 | 2" Fitting Schedule 80 Steam/Condensate | 4 | EA | ||
| B | B35 | 1 1/2" Fitting Schedule 80 Steam/Condensate | 4 | EA | ||
| B | B36 | 1 1/4" Fitting Schedule 80 Steam/Condensate | 4 | EA | ||
| B | B37 | 12" Pipe Schedule 40 Chilled Water | 40 | LF | ||
| B | B38 | 10" Pipe Schedule 40 Chilled Water | 20 | LF | ||
| B | B39 | 8" Pipe Schedule 40 Chilled Water | 40 | LF | ||
| B | B40 | 6" Pipe Schedule 40 Chilled Water | 45 | LF | ||
| B | B41 | 5" Pipe Schedule 40 Chilled Water | 45 | LF | ||
| B | B42 | 4" Pipe Schedule 40 Chilled Water | 60 | LF | ||
| B | B43 | 2" Pipe Schedule 40 Chilled Water | 40 | LF | ||
| B | B44 | 1 1/2" Pipe Schedule 40 Chilled Water | 40 | LF | ||
| B | B45 | 1 1/4" Pipe Schedule 40 Chilled Water | 40 | LF | ||
| B | B46 | 12" Pipe Schedule 80 Chilled Water | 100 | LF | ||
| B | B47 | 10" Pipe Schedule 80 Chilled Water | 40 | LF | ||
| B | B48 | 8" Pipe Schedule 80 Chilled Water | 60 | LF | ||
| B | B49 | 6" Pipe Schedule 80 Chilled Water | 100 | LF | ||
| B | B50 | 5" Pipe Schedule 80 Chilled Water | 90 | LF | ||
| B | B51 | 4" Pipe Schedule 80 Chilled Water | 80 | LF | ||
| B | B52 | 2" Pipe Schedule 80 Chilled Water | 100 | LF | ||
| B | B53 | 1 1/2" Pipe Schedule 80 Chilled Water | 30 | LF | ||
| B | B54 | 1 1/4" Pipe Schedule 80 Chilled Water | 30 | LF | ||
| B | B55 | 12" Fitting Schedule 40 Chilled Water | 4 | EA | ||
| B | B56 | 10" Fitting Schedule 40 Chilled Water | 7 | EA | ||
| B | B57 | 8" Fitting Schedule 40 Chilled Water | 7 | EA | ||
| B | B58 | 6" Fitting Schedule 40 Chilled Water | 4 | EA | ||
| B | B59 | 5" Fitting Schedule 40 Chilled Water | 7 | EA | ||
| B | B60 | 4" Fitting Schedule 40 Chilled Water | 7 | EA | ||
| B | B61 | 2" Fitting Schedule 40 Chilled Water | 7 | EA | ||
| B | B62 | 1 1/2" Fitting Schedule 40 Chilled Water | 8 | EA | ||
| B | B63 | 1 1/4" Fitting Schedule 40 Chilled Water | 8 | EA | ||
| B | B64 | 12" Fitting Schedule 80 Chilled Water | 7 | EA | ||
| B | B65 | 10" Fitting Schedule 80 Chilled Water | 7 | EA | ||
| B | B66 | 8" Fitting Schedule 80 Chilled Water | 7 | EA | ||
| B | B67 | 6" Fitting Schedule 80 Chilled Water | 6 | EA | ||
| B | B68 | 5" Fitting Schedule 80 Chilled Water | 6 | EA | ||
| B | B69 | 4" Fitting Schedule 80 Chilled Water | 6 | EA | ||
| B | B70 | 2" Fitting Schedule 80 Chilled Water | 7 | EA | ||
| B | B71 | 1 1/2" Fitting Schedule 80 Chilled Water | 6 | EA | ||
| B | B72 | 1 1/4" Fitting Schedule 80 Chilled Water | 6 | EA | ||
| JUNCTION BOX | ||||||
| C | C01 | Replace Valve (12") | 1 | EA | ||
| C | C02 | Replace Valve (10") | 2 | EA | ||
| C | C03 | Replace Valve (8") | 2 | EA | ||
| C | C04 | Replace Valve (6") | 2 | EA | ||
| C | C05 | Replace Valve (5") | 2 | EA | ||
| C | C06 | Replace Valve (4") | 1 | EA | ||
| C | C07 | Replace Valve (3") | 2 | EA | ||
| C | C08 | Replace Valve (2") | 2 | EA | ||
| C | C09 | Replace Valve (1 1/2") | 2 | EA | ||
| C | C10 | Replace Valve (1 1/4") | 2 | EA | ||
| C | C11 | Replace Valve (1") | 2 | EA | ||
| C | C12 | Replace Valve (1/2") | 2 | EA | ||
| C | C13 | Replace Flange Gasket (12") | 2 | EA | ||
| C | C14 | Replace Flange Gasket (10") | 2 | EA | ||
| C | C15 | Replace Flange Gasket (8") | 2 | EA | ||
| C | C16 | Replace Flange Gasket (6") | 2 | EA | ||
| C | C17 | Replace Flange Gasket (5") | 4 | EA | ||
| C | C18 | Replace Flange Gasket (4") | 4 | EA | ||
| C | C19 | Replace Flange Gasket (3") | 3 | EA | ||
| C | C20 | Replace Flange Gasket (2") | 4 | EA | ||
| C | C21 | Replace Flange Gasket (1 1/2") | 3 | EA | ||
| C | C22 | Replace Flange Gasket (1 1/4") | 3 | EA | ||
| C | C23 | Replace Flange (12") | 2 | EA | ||
| C | C24 | Replace Flange (10") | 3 | EA | ||
| C | C25 | Replace Flange (8") | 3 | EA | ||
| C | C26 | Replace Flange (6") | 2 | EA | ||
| C | C27 | Replace Flange (5") | 2 | EA | ||
| C | C28 | Replace Flange (4") | 3 | EA | ||
| C | C29 | Replace Flange (3") | 3 | EA | ||
| C | C30 | Replace Flange (2") | 4 | EA | ||
| C | C31 | Replace Flange (1 1/2") | 3 | EA | ||
| C | C32 | Replace Flange (1 1/4") | 2 | EA | ||
| C | C33 | Provide Gear Actuator(valves 6" and Larger) | 2 | EA | ||
| C | C34 | Insulate 1 1/2" fitting including Aluminum Jacket | 4 | EA | ||
| C | C35 | Insulate 2" fitting including Aluminum Jacket | 4 | EA | ||
| C | C36 | Insulate 3" fitting including Aluminum Jacket | 3 | EA | ||
| C | C37 | Insulate 4" fitting including Aluminum Jacket | 3 | EA | ||
| C | C38 | Insulate 5" fitting including Aluminum Jacket | 4 | EA | ||
| C | C39 | Insulate 6" fitting including Aluminum Jacket | 5 | EA | ||
| C | C40 | Insulate 8" fitting including Aluminum Jacket | 4 | EA | ||
| C | C41 | Insulate10" fitting including Aluminum Jacket | 4 | EA | ||
| C | C42 | Insulate 12" fitting including Aluminum Jacket | 5 | EA | ||
| C | C43 | Remove & Replace high pressure drip valve | 4 | EA | ||
| C | C44 | Remove & Replace bypass valve 1" | 4 | EA | ||
| C | C45 | Remove & Replace check valve 1" | 2 | EA | ||
| C | C46 | Remove & Replace steam valve 1" | 3 | EA | ||
| C | C47 | Remove & Replace globe valve 1" | 3 | EA | ||
| C | C48 | Remove & Replace bucket trap | 3 | EA | ||
| C | C49 | Remove & Replace gate valve blow off | 3 | EA | ||
| C | C50 | Remove & Replace strainer | 3 | EA | ||
| C | C51 | Remove & Replace Drip leg and fittings | 3 | EA | ||
| C | C52 | Remove & Replace Fin pipe radiator, 4' long, 4-1/2" fins | 3 | EA | ||
| C | C53 | Remove & Replace cooling control valve. | 2 | EA | ||
| C | C54 | Remove & Replace 2" vent w/ gooseneck | 2 | EA | ||
| C | C55 | Remove & Replace 6" vent and hood | 3 | EA | ||
| C | C56 | Remove & Replace condensate valve | 2 | EA | ||
| C | C57 | Remove & Replace bypass valve | 4 | EA | ||
| C | C58 | Remove & Replace check valve | 4 | EA | ||
| C | C59 | Remove & Replace steam valve | 4 | EA | ||
| C | C60 | Remove & Replace globe valve | 4 | EA | ||
| C | C61 | Remove & Replace bucket trap | 4 | EA | ||
| C | C62 | Remove & Replace gate valve blow off | 5 | EA | ||
| C | C63 | Remove & Replace strainer | 10 | EA | ||
| C | C64 | Remove & Replace High Pressure Orphic Trap w/ bucket trap | 1 | EA | ||
| C | C65 | Insulate 1 1/2" valve | 4 | EA | ||
| C | C66 | Insulate 2" valve | 4 | EA | ||
| C | C67 | Insulate 3" valve | 2 | EA | ||
| C | C68 | Insulate 4" valve | 2 | EA | ||
| C | C69 | Insulate 5" valve | 2 | EA | ||
| C | C70 | Insulate 6" valve | 2 | EA | ||
| C | C71 | Insulate 8" valve | 2 | EA | ||
| C | C72 | Insulate10" valve | 2 | EA | ||
| C | C73 | Insulate 12" valve | 2 | EA | ||
| C | C74 | Remove and Replace Steam Trap | 2 | EA | ||
| C | C75 | Remove and Replace Electric Ejector Pump | 2 | EA | ||
| C | C76 | Remove and Replace Steam Ejector Pump | 1 | EA | ||
| C | C77 | New sump pump in trench at high ground water location. | 2 | EA | ||
| C | C78 | Remove & Replace 1-1/2" Drain | 2 | EA | ||
| C | C79 | Remove & Replace Siphon | 2 | EA | ||
| C | C80 | Remove & Replace In-line strainer | 2 | EA | ||
| C | C81 | Remove & Replace Pipe strainer at bottom sump pit (Foot Valve) | 3 | EA | ||
| C | C82 | Remove & Replace 1-1/2" Weld-O-Let | 2 | EA | ||
| C | C83 | Remove & Replace Snap valve with bleed-off | 3 | EA | ||
| C | C84 | Remove & Replace 2'x2' Metal Grate 1"x1/4" at sump pit | 2 | EA | ||
| C | C85 | Replace Discharge Diffuser at Condensate Line connection. | 3 | EA | ||
| C | C86 | 1 1/2" Valve Access Cover | 2 | EA | ||
| C | C87 | 2" Valve Access Cover | 2 | EA | ||
| C | C88 | 3" Valve Access Cover | 2 | EA | ||
| C | C89 | 4" Valve Access Cover | 2 | EA | ||
| C | C90 | 5" Valve Access Cover | 2 | EA | ||
| C | C91 | 6" Valve Access Cover | 2 | EA | ||
| C | C92 | 8" Valve Access Cover | 2 | EA | ||
| C | C93 | 10" Valve Access Cover | 3 | EA | ||
| C | C94 | 12" Valve Access Cover | 3 | EA | ||
| TRENCHES | ||||||
| D | D01 | Replace 2" Pipe Hangers and Rollers Assembly | 5 | EA | ||
| D | D02 | Replace 3" Pipe Hangers and Rollers Assembly | 7 | EA | ||
| D | D03 | Replace 4" Pipe Hangers and Rollers Assembly | 5 | EA | ||
| D | D04 | Replace 5" Pipe Hangers and Rollers Assembly | 7 | EA | ||
| D | D05 | Replace 6" Pipe Hangers and Rollers Assembly | 5 | EA | ||
| D | D06 | Replace 8" Pipe Hangers and Rollers Assembly | 7 | EA | ||
| D | D07 | Replace 10" Pipe Hangers and Rollers Assembly | 8 | EA | ||
| D | D08 | Replace 12" Pipe Hangers and Rollers Assembly | 5 | EA | ||
| D | D09 | Replace Threaded rod @ Hardware for 2" Pipe Hangers / Rollers | 10 | EA | ||
| D | D10 | Replace Threaded rod @ Hardware for 3" Pipe Hangers / Rollers | 9 | EA | ||
| D | D11 | Replace Threaded rod @ Hardware for 4"Pipe Hangers / Rollers | 5 | EA | ||
| D | D12 | Replace Threaded rod @ Hardware for 5" Pipe Hangers / Rollers | 6 | EA | ||
| D | D13 | Replace Threaded rod @ Hardware for 6" Pipe Hangers / Rollers | 10 | EA | ||
| D | D14 | Replace Threaded rod @ Hardware for 8" Pipe Hangers / Rollers | 9 | EA | ||
| D | D15 | Replace Threaded rod @ Hardware for 10" Pipe Hangers/Rollers | 10 | EA | ||
| D | D16 | Replace Threaded rod @ Hardware for 12" Pipe Hangers/Rollers | 10 | EA | ||
| D | D17 | Replace 4" Pipe Anchor | 5 | EA | ||
| D | D18 | Replace 5" Pipe Anchor | 5 | EA | ||
| D | D19 | Replace 6" Pipe Anchor | 5 | EA | ||
| D | D20 | Replace 8" Pipe Anchor | 5 | EA | ||
| D | D21 | Replace 10" Pipe Anchor | 5 | EA | ||
| D | D22 | Replace 3" Pipe Anchor Band | 5 | EA | ||
| D | D23 | Replace 6" Pipe Anchor Band | 5 | EA | ||
| D | D24 | Replace 3" Pipe Anchor plate | 5 | EA | ||
| D | D25 | Replace 6" Pipe Anchor plate | 5 | EA | ||
| D | D26 | Replace Pipe Support 1-1/2" through 4" | 5 | EA | ||
| D | D27 | Replace Pipe Support 5" through 12" | 5 | EA | ||
| D | D28 | Replace Suspension Rod | 5 | EA | ||
| D | D29 | Replace Pipe Alignment Guide 2" through 14" | 5 | EA | ||
| D | D30 | Install 5" Pipe Saddle | 5 | EA | ||
| D | D31 | Install 6" Pipe Saddle | 5 | EA | ||
| D | D32 | Remove/Reinstall/Reseal Concrete Trench Cover | 4 | EA | ||
| D | D33 | Provide and Install New Reinforced Concrete Trench Cover, 4'W x 3'L x 9"D, with embedded lift pins (match exg). Actual size vary to fit field conditions (at roadways with raiting not less than H20 Truck Load). | 4 | EA | ||
| D | D34 | Provide and Install New Reinforced Concrete Trench Cover, 4'W x 3'L x 6"D, with embedded lift pins (match exg). Actual size vary to fit field conditions (at sidewalks). | 4 | EA | ||
| D | D35 | Patch Concrete where deteriorated at top edge of Conc trench. | 40 | LF | ||
| D | D36 | Remove exg deteriorated L4x4x +/-4’-0” angle pipe support; Provide and install new galv L4x4 angle. | 100 | LF | ||
| D | D37 | At Drip Leg / Steam Ejector: Remove trench cap support beam, W8x31x +/-5’-5” ; Provide and install new support beam and end bearing angles. Paint with rust proof primer. | 1 | EA | ||
| D | D38 | At Expansion Loop: Remove trench cap support beam, W8x48x +/-9’-8” ; Provide and install new galv support beam and end bearing angles. | 2 | EA | ||
| D | D39 | At Expansion Loop: Remove trench cap support beam, W8x31x +/-4’-7” ; Provide and install new support beam. Paint with rust proof primer. | 2 | EA | ||
| D | D40 | At Junction Box: Remove exg cap support beam, W8x48x +/-7’-6”; Provide and install new support beam and end bearing angles. Paint with rust proof primer. | 3 | EA | ||
| D | D41 | At Junction Box: Remove exg cap support beam, W8x48x +/-4’-0”; Provide and install new galv support beam. | 3 | EA | ||
| SITE WORK | ||||||
| E | E01 | Steel Plates for road trench cover to support vehicular traffic. | 6 | EA | ||
| E | E02 | Fencing 6' w/ brown fabric covering | 600 | LF | ||
| E | E03 | Remove & replace Granite Curb | 200 | LF | ||
| E | E04 | Remove, Dispose of & Replace Bituminous Conc. Curb | 200 | LF | ||
| E | E05 | Remove, Dispose of & Replace Concrete Curb | 200 | LF | ||
| E | E06 | Remove, Dispose of & Replace Concrete Sidewalk | 200 | CY | ||
| E | E07 | Remove, Dispose of & Replace Bituminous Sidewalk | 200 | CY | ||
| E | E08 | Excavate and Repave Direct Burial of Concrete Trench Cover under 5" pavement. | 100 | CY | ||
| E | E09 | Excavate for Direct Burial of Concrete Trench Cover under 6" of Grass area | 200 | CY | ||
| E | E10 | Remove and stockpile Topsoil | 100 | SY | ||
| E | E11 | Place topsoil back in original locations | 200 | SY | ||
| E | E12 | Provide and spread Loam | 1,000 | CY | ||
| E | E13 | Spread Fertilizer | 2,000 | SY | ||
| E | E14 | Spread Lime | 1,000 | SY | ||
| E | E15 | Spread Grass Seeds | 30 | LB | ||
| E | E16 | Spread Hydro Grass Seed | 7,000 | SF | ||
| E | E17 | Sedimentation Control Bale Barrier | 20 | LF | ||
| E | E18 | Ordinary Borrow | 100 | CY | ||
| E | E19 | Gravel Borrow | 100 | CY | ||
| E | E20 | Gravel Base | 100 | CY | ||
| E | E21 | Crushed Stone | 100 | CY | ||
| E | E22 | Sand Borrow | 80 | CY | ||
| E | E23 | Removal & disposal of excess excavation material | 200 | CY | ||
| E | E24 | Saw Cut Bit. Pavement | 50 | LF | ||
| E | E25 | Test Pit Excavation | 30 | CY | ||
| E | E26 | New drywell adjacent to new sump pump. Include related piping. | 1 | EA | ||
| E | E27 | Provide Traffic Sign | 8 | EA | ||
| E | E28 | Jersey Barriers with 3' fence | 300 | LF | ||
| E | E29 | Excavate for Direct Burial Pipe (Double) | 480 | CY | ||
| E | E30 | Excavate for Direct Burial Pipe (Single) | 480 | CY | ||
| E | E31 | Trench Shoring 4 to 8 feet | 200 | LF | ||
| E | E32 | Trench Shoring 8 and above | 200 | LF | ||
| WATER | ||||||
| F | F01 | Copper pipe, 1/2" diameter | 100 | LF | ||
| F | F02 | Copper pipe, 3/4" diameter | 100 | LF | ||
| F | F03 | Copper pipe, 1" diameter | 200 | LF | ||
| F | F04 | Copper pipe, 1 1/2" diameter | 80 | LF | ||
| F | F05 | Copper pipe, 2" diameter | 200 | LF | ||
| F | F06 | Service connection, Size <= 1 1/2" | 4 | EA | ||
| F | F07 | Service connection, 1-1/2" > Size <= 2 1/2" | 4 | EA | ||
| F | F08 | Service connection, Size > 2 1/2" | 4 | EA | ||
| F | F09 | Ductile iron pipe, 4" diameter | 200 | LF | ||
| F | F10 | Ductile iron pipe, 6" diameter | 100 | LF | ||
| F | F11 | Ductile iron pipe, 8" diameter | 100 | LF | ||
| F | F12 | Ductile iron pipe, 10" diameter | 80 | LF | ||
| F | F13 | Ductile iron pipe, 12" diameter | 80 | LF | ||
| F | F14 | Ductile iron pipe, 16" diameter | 40 | LF | ||
| F | F15 | Hose bib, up to 1 1/2" diameter | 10 | EA | ||
| F | F16 | Ball valve, 1/2" to 1" diameter | 4 | EA | ||
| F | F17 | Ball valve, 1 1/2" to 2" diameter | 4 | EA | ||
| F | F18 | Curb stop valve, 3/4" diameter | 10 | EA | ||
| F | F19 | Curb stop valve, 1" diameter | 4 | EA | ||
| F | F20 | Curb stop valve, 1 1/2" diameter | 10 | EA | ||
| F | F21 | Curb stop valve, 2" diameter | 4 | EA | ||
| F | F22 | Water gate valve, 2" diameter | 4 | EA | ||
| F | F23 | Water gate valve, 3" diameter | 4 | EA | ||
| F | F24 | Water gate valve, 4" diameter | 4 | EA | ||
| F | F25 | Water gate valve, 6" diameter | 4 | EA | ||
| F | F26 | Water gate valve, 8" diameter | 4 | EA | ||
| F | F27 | Water gate valve, 10" diameter | 4 | EA | ||
| F | F28 | Water gate valve, 12" diameter | 4 | EA | ||
| F | F29 | Water gate valve, 16" diameter | 4 | EA | ||
| F | F30 | Post indicator valve, 6" diameter | 4 | EA | ||
| F | F31 | Post indicator valve, 8" diameter | 4 | EA | ||
| F | F32 | Water gate casting and cover | 5 | VF | ||
| F | F33 | Ductile iron fitting, 4" diameter | 3 | EA | ||
| F | F34 | Ductile iron fitting, 6" diameter | 3 | EA | ||
| F | F35 | Ductile iron fitting, 8" diameter | 3 | EA | ||
| F | F36 | Ductile iron fitting, 10" diameter | 3 | EA | ||
| F | F37 | Ductile iron fitting, 12" diameter | 3 | EA | ||
| F | F38 | Ductile iron fitting, 16" diameter | 3 | EA | ||
| F | F39 | Pipe coupling, 3" dia | 3 | EA | ||
| F | F40 | Pipe coupling, 4" dia | 3 | EA | ||
| F | F41 | Pipe coupling, 6" dia | 3 | EA | ||
| F | F42 | Pipe coupling, 8" dia | 3 | EA | ||
| F | F43 | Pipe coupling, 10" dia | 3 | EA | ||
| F | F44 | Pipe coupling, 12" dia | 3 | EA | ||
| F | F45 | Pipe coupling, 16" dia | 3 | EA | ||
| F | F46 | Drill and tap unpressurized main ("dry tap") <=8" | 3 | EA | ||
| F | F47 | Drill and tap unpressurized main ("dry tap") > 8" | 3 | EA | ||
| F | F48 | Drill and tap pressurized main ("wet tap") <=8" | 3 | EA | ||
| F | F49 | Drill and tap pressurized main ("wet tap") > 8" | 3 | EA | ||
| F | F50 | Pressure testing, sanitizing and lab analysis | 3 | EA | ||
| F | F51 | Fire hydrant | 3 | EA | ||
| F | F52 | Relocate fire hydrant | 4 | EA | ||
| F | F53 | 6" Fire Hydrant Extension Kit | 3 | EA | ||
| F | F54 | 12" Fire Hydrant Extension Kit | 3 | EA | ||
| F | F55 | 18" Fire Hydrant Extension Kit | 3 | EA | ||
| F | F56 | 24" Fire Hydrant Extension Kit | 3 | EA | ||
| F | F57 | Temporary By-Pass Piping | 400 | LF | ||
| SANITARY SEWER | ||||||
| G | G01 | Clean and inspect sewer lines 12" and under | 240 | LF | ||
| G | G02 | Clean and inspect sewer lines over 12" | 200 | LF | ||
| G | G03 | PVC sewer pipe, 4" | 100 | LF | ||
| G | G04 | PVC sewer pipe, 6" | 100 | LF | ||
| G | G05 | PVC sewer pipe, 8" | 100 | LF | ||
| G | G06 | PVC sewer pipe, 10" | 200 | LF | ||
| G | G07 | PVC sewer pipe, 12" | 400 | LF | ||
| G | G08 | PVC sewer pipe, 15" | 40 | LF | ||
| G | G09 | PVC sewer pipe, 18" | 400 | LF | ||
| G | G10 | PVC service connection, 4" | 60 | LF | ||
| G | G11 | PVC service connection, 6" | 4 | LF | ||
| G | G12 | PVC service connection, 8" | 4 | LF | ||
| G | G13 | PVC wye/tee connection, 4" | 5 | EA | ||
| G | G14 | PVC wye/tee connection, 6" | 5 | EA | ||
| G | G15 | PVC wye/tee connection, 8" | 5 | EA | ||
| G | G16 | PVC wye/tee connection, 10" | 5 | EA | ||
| G | G17 | PVC wye/tee connection, 12" | 4 | EA | ||
| G | G18 | PVC wye/tee connection, 15" | 5 | EA | ||
| G | G19 | PVC wye/tee connection, 18" | 4 | EA | ||
| G | G20 | PVC Chimney, 4" | 2 | VF | ||
| G | G21 | PVC Chimney, 5" | 2 | VF | ||
| G | G22 | PVC Chimney, 6" | 2 | VF | ||
| G | G23 | Resinous liner, 6" | 20 | LF | ||
| G | G24 | Resinous liner, 8" | 20 | LF | ||
| G | G25 | Resinous liner, 10" | 20 | LF | ||
| G | G26 | Resinous liner, 12" | 20 | LF | ||
| G | G27 | Resinous liner, 15" | 20 | LF | ||
| G | G28 | Resinous liner, 18" | 20 | LF | ||
| G | G29 | Pipe bursting, 6" | 20 | LF | ||
| G | G30 | Pipe bursting, 8" | 20 | LF | ||
| G | G31 | Pipe bursting, 10" | 20 | LF | ||
| G | G32 | Pipe bursting, 12" | 20 | LF | ||
| G | G33 | Pipe bursting, 15" | 20 | LF | ||
| G | G34 | Pipe bursting, 18" | 20 | LF | ||
| G | G35 | Drop connection, any size | 20 | LF | ||
| G | G36 | Tree root removal | 20 | LF | ||
| G | G37 | Clean sewer manhole | 5 | EA | ||
| G | G38 | Repair structure - trough | 20 | EA | ||
| G | G39 | Sewer manhole, 4' diameter | 3 | VF | ||
| G | G40 | Sewer manhole, 5' diameter | 3 | VF | ||
| G | G41 | Sewer manhole, 6' diameter | 3 | VF | ||
| STORM DRAINAGE | ||||||
| H | H01 | Catchbasin/manhole, 4' diameter | 1 | VF | ||
| H | H02 | Catchbasin/manhole, 5' diameter | 1 | VF | ||
| H | H03 | Catchbasin/manhole, 6' diameter | 1 | VF | ||
| H | H04 | Catchbasin casting and cover | 3 | EA | ||
| H | H05 | Manhole casting and cover | 3 | EA | ||
| H | H06 | Clean and adjust structure | 3 | EA | ||
| H | H07 | Deepen structure | 1 | VF | ||
| H | H08 | Repair structure | 1 | VF | ||
| H | H09 | Reinforced concrete pipe, 12" dia | 10 | LF | ||
| H | H10 | Reinforced concrete pipe, 18" dia | 10 | LF | ||
| H | H11 | Reinforced concrete pipe, 24" dia | 10 | LF | ||
| H | H12 | PVC drain pipe, 6" dia | 30 | LF | ||
| H | H13 | PVC drain pipe, 8" dia | 30 | LF | ||
| H | H14 | PVC drain pipe, 12" dia | 20 | LF | ||
| H | H15 | PVC drain pipe, 15" dia | 10 | LF | ||
| H | H16 | PVC drain pipe, 18" dia | 10 | LF | ||
| H | H17 | PVC drain pipe, 21" dia | 20 | LF | ||
| H | H18 | PVC drain pipe, 24" dia | 20 | LF | ||
| H | H19 | Foundation drain, 4” diameter | 100 | LF | ||
| H | H20 | Foundation drain, 6” diameter | 80 | LF | ||
| H | H21 | Foundation drain, 8” diameter | 80 | LF | ||
| H | H22 | Existing storm drain pipe cleaning | 300 | LF | ||
| H | H23 | Existing storm structure cleaning | 4 | EA | ||
| ELECTRIC/COMM | ||||||
| J | J01 | Install GRS Conduit < 1" | 10 | LF | ||
| J | J02 | Install GRS Conduit 1" - 2" | 40 | LF | ||
| J | J03 | Install GRS Conduit > 2" | 80 | LF | ||
| J | J04 | Remove GRS Conduit < 1" | 20 | LF | ||
| J | J05 | Remove GRS Conduit 1" - 2" | 20 | LF | ||
| J | J06 | Remove GRS Conduit > 2" | 20 | LF | ||
| J | J07 | Remove PVC Conduit < 1" | 20 | LF | ||
| J | J08 | Remove PVC Conduit 1" - 2" | 20 | LF | ||
| J | J09 | Remove PVC Conduit > 2" | 20 | LF | ||
| J | J10 | Install PVC Conduit < 1" | 60 | LF | ||
| J | J11 | Install PVC Conduit 1" - 2" | 80 | LF | ||
| J | J12 | Install PVC Conduit > 2" | 100 | LF | ||
| J | J13 | Trap Monitor and Transmitter | 4 | EA | ||
| J | J14 | Trap Monitor Relay | 4 | EA | ||
| J | J15 | #14 Wire | 400 | LF | ||
| J | J16 | #12 Wire | 600 | LF | ||
| J | J17 | #10 Wire | 600 | LF | ||
| J | J18 | #8 Wire | 200 | LF | ||
| MECHANICAL ROOMS | ||||||
| K | K01 | Asbestos Abatement 10" Pipe | 100 | LF | ||
| K | K02 | Asbestos Abatement 8" Pipe | 80 | LF | ||
| K | K03 | Asbestos Abatement 6" Pipe | 20 | LF | ||
| K | K04 | Asbestos Abatement 5" Pipe | 20 | LF | ||
| K | K05 | Asbestos Abatement 4" Pipe | 80 | LF | ||
| K | K06 | Asbestos Abatement 2" Pipe | 60 | LF | ||
| K | K07 | Asbestos Abatement 1 1/2" Pipe | 20 | LF | ||
| K | K08 | Asbestos Abatement 1 1/4" Pipe | 60 | LF | ||
| K | K09 | Remove existing flash tank. | 3 | EA | ||
| K | K10 | Provide and install new flash tank. | 3 | EA | ||
| K | K11 | Remove existing condensate receiver pump. | 4 | EA | ||
| K | K12 | Provide and install new condensate receiver pump. | 4 | EA | ||
| K | K13 | Insulate Heat Exchanger | 4 | EA | ||
| K | K14 | Insulate flash tank | 4 | EA | ||
| K | K15 | Insulate 1 1/2" Pipe | 100 | LF | ||
| K | K17 | Insulate 2" Pipe | 400 | LF | ||
| K | K18 | Insulate 3" Pipe | 100 | LF | ||
| K | K19 | Insulate 4" Pipe | 400 | LF | ||
| K | K20 | Insulate 5" Pipe | 100 | LF | ||
| K | K21 | Insulate 6" Pipe | 400 | LF | ||
| K | K22 | Insulate 8" Pipe | 100 | LF | ||
| K | K23 | Insulate10" Pipe | 100 | LF | ||
| K | K24 | Insulate Fitting (6") | 15 | EA | ||
| K | K25 | Insulate Fitting (4") | 15 | EA | ||
| K | K26 | Insulate Fitting (3") | 15 | EA | ||
| K | K27 | Insulate Fitting (2") | 15 | EA | ||
| K | K28 | Insulate Fitting (1 1/2") | 15 | EA | ||
| K | K29 | Insulate Fitting (1") | 15 | EA | ||
| K | K30 | Insulate Fitting (3/4") | 15 | EA | ||
| K | K31 | Insulate Fitting (1/2") | 15 | EA | ||
| K | K32 | Insulate Valve (6") | 15 | EA | ||
| K | K33 | Insulate Valve (4") | 15 | EA | ||
| K | K34 | Insulate Valve (3") | 15 | EA | ||
| K | K35 | Insulate Valve (2") | 15 | EA | ||
| K | K36 | Insulate Valve (1 1/2") | 15 | EA | ||
| K | K37 | Insulate Valve (1") | 15 | EA | ||
| K | K38 | Insulate Valve (3/4") | 10 | EA | ||
| K | K39 | Insulate Valve (1/2") | 10 | EA | ||
| K | K40 | Provide wrap around & strap on Pipe Markers 1 1/2" | 5 | EA | ||
| K | K41 | Provide wrap around & strap on Pipe Markers 2" | 20 | EA | ||
| K | K42 | Provide wrap around & strap on Pipe Markers 3" | 10 | EA | ||
| K | K43 | Provide wrap around & strap on Pipe Markers 4" | 20 | EA | ||
| K | K44 | Provide wrap around & strap on Pipe Markers 5" | 5 | EA | ||
| K | K45 | Provide wrap around & strap on Pipe Markers 6" | 4 | EA | ||
| K | K46 | Provide wrap around & strap on Pipe Markers 8" | 5 | EA | ||
| K | K47 | Provide wrap around & strap on Pipe Markers 10" | 5 | EA | ||
| K | K48 | Install Dosing Pot | 5 | EA | ||
| K | K49 | Replace Valve (12") | 10 | EA | ||
| K | K50 | Replace Valve (10") | 10 | EA | ||
| K | K51 | Replace Valve (8") | 10 | EA | ||
| K | K52 | Replace Valve (6") | 40 | EA | ||
| K | K53 | Replace Valve (5") | 10 | EA | ||
| K | K54 | Replace Valve (4") | 8 | EA | ||
| K | K55 | Replace Valve (3") | 6 | EA | ||
| K | K56 | Replace Valve (2") | 8 | EA | ||
| K | K57 | Replace Valve (1 1/2") | 6 | EA | ||
| K | K58 | Replace Valve (1 1/4") | 6 | EA | ||
| K | K59 | Replace Valve (1") | 15 | EA | ||
| K | K60 | Replace Valve (1/2") | 12 | EA | ||
| K | K61 | Replace Flange Gasket (12") | 6 | EA | ||
| K | K62 | Replace Flange Gasket (10") | 9 | EA | ||
| K | K63 | Replace Flange Gasket (8") | 10 | EA | ||
| K | K64 | Replace Flange Gasket (6") | 15 | EA | ||
| K | K65 | Replace Flange Gasket (5") | 12 | EA | ||
| K | K66 | Replace Flange Gasket (4") | 15 | EA | ||
| K | K67 | Replace Flange Gasket (3") | 12 | EA | ||
| K | K68 | Replace Flange Gasket (2") | 15 | EA | ||
| K | K69 | Replace Flange Gasket (1 1/2") | 15 | EA | ||
| K | K70 | Replace Flange Gasket (1 1/4") | 15 | EA | ||
| K | K71 | Replace Flange (12") | 15 | EA | ||
| K | K72 | Replace Flange (10") | 15 | EA | ||
| K | K73 | Replace Flange (8") | 15 | EA | ||
| K | K74 | Replace Flange (6") | 15 | EA | ||
| K | K75 | Replace Flange (5") | 15 | EA | ||
| K | K76 | Replace Flange (4") | 15 | EA | ||
| K | K77 | Replace Flange (3") | 15 | EA | ||
| K | K78 | Replace Flange (2") | 15 | EA | ||
| K | K79 | Replace Flange (1 1/2") | 10 | EA | ||
| K | K80 | Replace Flange (1 1/4") | 10 | EA | ||
| K | K81 | Prepare Asbestos Removal Plan | 10 | EA | ||
| TEMPORARY HEAT | ||||||
| L | L01 | Temporary Piping 1 1/2" | 50 | LF | ||
| L | L02 | Temporary Piping 2" | 100 | LF | ||
| L | L03 | Temporary Piping 3" | 50 | LF | ||
| L | L04 | Temporary Piping 4" | 100 | LF | ||
| L | L05 | Temporary Piping 5" | 50 | LF | ||
| L | L06 | Temporary Piping 6" | 100 | LF | ||
| L | L07 | Temporary Piping 8" | 50 | LF | ||
| MISCELLANEOUS | ||||||
| M | M01 | Manufacturer Commissioning and Certification | 4 | EA | ||
| M | M02 | Clean Trench | 1,000 | LF | ||
| M | M03 | Mobilization & Demobilization No Excavation Required | 4 | EA | ||
| M | M04 | Mobilization & Demobilization Excavation Required | 6 | EA | ||
| M | M05 | Red Lines | 100 | HR | ||
| M | M06 | Record Drawings | 100 | HR | ||
| Line Item Total: | $0.00 | |||||
| Coefficients | ||||||
| Hanscom AFB | 0.00% | $0.00 | ||||
| Premium Time | 0.00% | $0.00 |
Sub-Total incl. Coefficients $0.00
| Overhead | 0.00% | $0.00 |
| G&A | 0.00% | $0.00 |
| Other Direct Cost | 0.00% | $0.00 |
| Bond | 0.00% | $0.00 |
| Profit | 0.00% | $0.00 |
Project Total $0.00
&"Arial,Bold"&14Steam and Condensate IDIQ &D &"Arial,Bold"&14FY2015 Contract (5 Year Ordering Period) Period 02 - 01 Oct 16 - 30 Sep 17
&12Page &P of &N
BID (3)
| Sub Sch | Line No. | DESCRIPTION | ESTIMATED | |
| QUANTITY | UM | UNIT | ||
| PRICE | ESTIMATED |
TOTAL
| PIPES & FITTINGS IN CONCRETE TRENCHES | ||||||
| A | A01 | Replace Pipe (12") Schedule 40 | 100 | LF | ||
| A | A02 | Replace Pipe (10") Schedule 40 | 20 | LF | ||
| A | A03 | Replace Pipe (8") Schedule 40 | 40 | LF | ||
| A | A04 | Replace Pipe (6") Schedule 40 | 40 | LF | ||
| A | A05 | Replace Pipe (5") Schedule 40 | 20 | LF | ||
| A | A06 | Replace Pipe (4") Schedule 40 | 80 | LF | ||
| A | A07 | Replace Pipe (3") Schedule 40 | 20 | LF | ||
| A | A08 | Replace Pipe (2") Schedule 40 | 100 | LF | ||
| A | A09 | Replace Fitting (12") Schedule 40 | 10 | EA | ||
| A | A10 | Replace Fitting (10") Schedule 40 | 10 | EA | ||
| A | A11 | Replace Fitting (8") Schedule 40 | 10 | EA | ||
| A | A12 | Replace Fitting (6") Schedule 40 | 10 | EA | ||
| A | A13 | Replace Fitting (5") Schedule 40 | 10 | EA | ||
| A | A14 | Replace Fitting (4") Schedule 40 | 10 | EA | ||
| A | A15 | Replace Fitting (3") Schedule 40 | 10 | EA | ||
| A | A16 | Replace Fitting (2") Schedule 40 | 10 | EA | ||
| A | A17 | Replace Pipe (12") Schedule 80 | 100 | LF | ||
| A | A18 | Replace Pipe (10") Schedule 80 | 80 | LF | ||
| A | A19 | Replace Pipe (8") Schedule 80 | 80 | LF | ||
| A | A20 | Replace Pipe (6") Schedule 80 | 100 | LF | ||
| A | A21 | Replace Pipe (5") Schedule 80 | 80 | LF | ||
| A | A22 | Replace Pipe (4") Schedule 80 | 20 | LF | ||
| A | A23 | Replace Pipe (3") Schedule 80 | 60 | LF | ||
| A | A24 | Replace Pipe (2") Schedule 80 | 100 | LF | ||
| A | A25 | Replace Fitting (12") Schedule 80 | 10 | EA |