This document appears to be a systems plan for the Card Reader and Control Panel Locations of the Weapon Algorithm Research Facility (WARF) T-101 at Eglin Air Force Base in Florida.
The systems plan details the access control system, intrusion detection system, and closed-circuit television (CCTV) system for the facility. It provides specifications for components such as card readers, control panels, cameras, and monitoring locations. The plan also includes general notes, keyed notes, and a scale floor plan showing the layout of the various rooms and equipment. While this document does not directly address a federal contract opportunity, it appears to be supporting documentation related to the requirements for the facility's security systems.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
REF.REF.
W
W W
CR
CR
B
T V
T V
T V
H D
DB
C H
T V
HD
H D
HDH
D
HDHD
CR
CR
C R
C C
CC
CONFERENCE
UNI-SEX
R-2
UNI-SEX
R-3
LACTATION
JAN.
96CS TR
MECH/RISER
WAP
SIPRJWICS
T-400
SECTION CHIEF
#1
TV
IDS
ALGORITHM LAB
BREAK AREA
SECTION CHIEF
#2
UNI-SEX
R-1
ELEC.
CATV
TV
JS
J S
S J
S
J
S
J
SJSJ
RF LAB
J
S
S J
J
S
TV
J S
SMT
BD
VESTIBULE
CORRIDOR
J
S
OPEN OFFICE
AREA
JSJS
DREN
ENCLAVE
C C
T V
A C
S
SYS
AC
S
J
A
A
A
A
B
B
AB
SCALE:
3/16" = 1' - 0"
4' 8' 12'
PLAN NORTH
US Army Corps of Engineers
SHEET ID
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
P R
O J E
C T
N U
M B
E R
A
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
D E
S C
R
IP
T
IO
N
T-101
W E
A P
O N
A L G
O R
IT
H
M R
E S
E A
R C
H F
A C
IL
IT
Y R
E S
E A
R C
H F
A C
IL
IT
Y
W A
R F
M o b ile
D is tr ic t L C
T A
M B
L Y
N
L C
T A
M B
L Y
N
D D
C O
L L
IE
R
C P
G U
N N
N O
V E
M B
E R
W -X
X -X
-X X
X X
W -X
X -X
-X X
X X
M H
F
FTFA-19JC03
E G
L
IN
A F
B F
L
S
A
IN
T J
O S
E P
H S
T R
E E
T M
O B
IL
E
A L
S Y
S T
E M
S P
L A
N
3/16" = 1'-0"1
SYSTEMS PLAN
GENERAL NOTES:
1. ACCESS CONTROL SYSTEM CONSISTS OF CONDUIT AND BOXES
FOR COMMUNICATION CABLE, AND CONSISTS OF WIRE, CONDUIT,
AND BOXES FOR POWER. END EQUIPMENT AND COMMUNICATION
CABLE IS PART OF A DIFFERENT SOLE SOURCE CONTRACT.
2. INTRUSION DETECTION SYSTEM CONSISTS OF CONDUIT AND
BOXES FOR COMMUNICATION CABLE, AND CONSISTS OF WIRE,
CONDUIT, AND BOXES FOR POWER. END EQUIPMENT AND
COMMUNICATION CABLE IS PART OF A DIFFERENT SOLE SOURCE
CONTRACT.
3. CCTV SYSTEM CONSISTS OF CONDUIT, COMMUNICATION CABLE,
AND BOXES FOR COMMUNICATION CABLE; WIRE, CONDUIT, AND
BOXES FOR POWER; AND END EQUIPMENT.
KEYED NOTES:
PROVIDE A SPIN-DIAL COMBINATION LOCK, LOCKMASTER CDX-10,
THAT MEETS CURRENT VERSION OF FEDERAL SPEC FFL-2740,
EQUIPPED WITH A LIFE SAFETY PUSH-BUTTON FEATURE,
PROVIDED THE BUTTON FEATURE IS ENABLED AT ALL TIMES THE
SECURE ROOM IS OCCUPIED.
DOORBELL IS MOUNTED ABOVE CARD READER, AND CHIME IS
ABOVE WATER FOUNTAIN 8 FEET AFF.
ALL OUTLETS IN LABS ARE AT 4 FEET AFF.
FOR CONFERENCE ROOM, SEE T-504 FOR FLOOR BOX DETAILS 1
& 2. PROVIDE CONNECTIONS IN TABLE FOR LAPTOPS. FOR
SECTION CHIEF OFFICES, SEE T-603, DETAIL 1 FOR ROUTING FOR
SECTION CHIEF TO CONNECT TO SCREEN IN THE OFFICE.
SIPR WALL MOUNT CABINET SHALL BE SPECIFIED BY 96CS, AND
THE SIZING WILL BE DEPENDENT ON THE REQUIREMENT FOR
SIPR DROPS.
WIRELESS ACCESS POINTS ARE FOR GOVERNMENT NETWORK.
LOCATION OF EGLIN EMCS CABINET. SEE DETAIL 4, T-502.
FOR ALL CAMERAS AND MONITORING LOCATIONS, PROVIDE
COMMUNICATION CONDUIT FROM THE ELECTRICAL ROOM,
COMMUNICATIONS CABLE, BOXES, AND POWER WIRE. CAMERA
SYSTEM IS AN INTERNAL BUILDING CCTV NETWORK. EXTERIOR
DOOR CAMERAS AND CAMERAS AT GATE ARE MONITORED AT
THE OPEN OFFICE FRONT DOOR DESK. HALL CAMERA IS
MONITORED WITHIN THE VESTIBULE. PROVIDE CONDUIT AND
POWER TO AGREE WITH MONITORING LOCATIONS. EXTERIOR
CAMERAS ARE AT 12' 6" AFF.
PROVIDE RADIO FREQUENCY (RF) SHIELDING ON ALL FOUR
WALLS OF EACH OF THREE SECURE ROOMS.
DREN AND ENCLAVE CABINETS ARE ON A TELEPHONE
BACKBOARD ABOVE THE WATER FOUNTAIN. CENTER OF
CABINETS ARE AT 9' AFF. POWER RECEPTACLE IS IN BOTTOM
LEFT SIDE OF CABINET.
EXTERIOR ACCESS CONTROL INCLUDING GATE; EXTERIOR CCTV
INCLUDING GATE; AND GATE ARE MONITORED AND CONTROLLED
AT THE OPEN OFFICE FRONT DESK. PROVIDE A PATHWAY FROM
THE ELECTRICAL ROOM TO THE FRONT DESK.
HALLWAY CCTV IS MONITORED AT THE VESTIBULE DESK.
PROVIDE TWO NIPR DROPS, ONE DREN DROP, AND ONE ENCLAVE
DROP AT EACH WORKSTATION. SEE TELECOMMUNICATIONS
LEGEND T-001 AND DETAILS ON EP502.
EACH OF THE ROOMS, VESTIBULE, RF LAB, AND ALGORITHM LAB
IS A SECURE ROOM.