Access Control for WARF from RTA_Drawings Page T-604.pdf

PDF 85 KB Posted

Attached to
Purchase & Installation of Lenel Access Control System
Solicitation number
FA282324Q0052
Issued by

About this file

This document appears to be an architectural drawing detailing the access control system (ACS) requirements for the Weapon Algorithm Research Facility (WARF) at Eglin Air Force Base. The drawing provides specifications for the installation of power, boxes, pathways, and pull strings to support the ACS, which will be provided under a separate contract. Key details include requirements for card readers, electric door strikes, motion detectors, and door position switches. The drawing also includes general notes and a legend to guide the installation. This drawing is likely part of the technical specifications for a federal contract opportunity to purchase and install a Lenel ACS at the WARF facility.

View the file

Other files

File Type Posted
Card Reader and Control Panel Locations WARF T101.pdf PDF
WARF Door Hardware.pdf PDF
Access Control System QA.pdf PDF
Amendment FA282324Q00520002 SF 30 SIGNED.pdf PDF
Solicitation Amendment FA282324Q00520001 SF 30.pdf PDF
Solicitation - FA282324Q0052.pdf PDF
RFQ Attachment Addendum 2.pdf PDF
RFQ Attachment Addendum 3.pdf PDF
SOW.pdf PDF
SCA WD NEWAUG1.pdf PDF
SVL PDF.pdf PDF
SSJ Redacted.pdf PDF
RFQ Attachment Cover_Sheet example.pdf PDF
Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

8"

A .F

.F

INTERNAL

CONNECTION

CEILING LINE

12 2

8"

A .F

.F

CEILING LINE

1. CONTRACTOR PROVIDES ONLY ROUGH IN OF ACCESS CONTROL SYSTEM (ACS) CONSISTING OF ALL POWER, BOXES, PATHWAYS, AND PULL STRING. ACS COMMUNICATION CABLE AND END EQUIPMENT IS PROVIDED UNDER A SEPARATE

CONTRACT.

2. CONTRACTOR SHALL COORDINATE ALL DOOR HARDWARE WITH ARCHITECTURAL HARDWARE SCHEDULE. THIS SHEET

IS SHOWN AS TYPICAL ONLY.

3. CONTRACTOR SHALL INSTALL FLUSH MOUNT JUNCTION BOX FOR ALL EQUIPMENT SHOWN AS NOT IN CONTRACT (NIC).

4. PROVIDE 3' EXCESS CONDUCTOR AT ALL ICIDS PANEL LOCATIONS.

5. PER UFC 3-600-01 4-44, DOOR PERSONNEL "ACCESS CONTROL SYSTEMS" MUST NOT RESTRICT FREE EGRESS AT ALL TIMES. BADGE ID READERS MAY BE INSTALLED ON THE INTERIOR SIDE OF A DOOR FOR PERSONNEL "AUDIT" PURPOSES ONLY, BUT MUST NOT BE CONNECTED TO ANY PHYSICAL SECURITY DOOR HARDWARE (I.E. ELECTRIC DOOR STRIKES, MAGNETIC LOCKS, ETC.) THAT WOULD RESTRICT SINGLE-MOTION DOOR OPERATION.

GENERAL NOTES:

KEYED NOTES: (APPLICABLE TO THIS SHEET)

1. CARD READER MOUNTS TO ELECTRIC BOX ON UNSECURED SIDE OF DOOR.

2. ELECTRIFIED EXIT DEVICE.

3. ELECTRIC TRANSFER HINGES MOUNTED TO DOOR FRAME. CONNECT TO ELECTRIC LEVER SET.

4. REX MOTION DECTECTOR MOUNTS TO SINGLE GANGE ELECTRICAL BOX ON SECURED SIDE OF DOOR.

5. FLUSH MOUNTED DOOR POSITION SWITCH MOUNTED AT TOP OF DOOR ON SECURE SIDE OF DOOR.

6. CONDUIT SIZED PER LOCATION AND DEVICE.

7. CONNECTION FROM ELECTRIC LOCKSET TO ELECTRIC TRANSFER DEVICE.

8. JUNCTION BOX ON SECURE SIDE OF DOOR IN ACCESSIBLE SPACE.

9. NOT USED

10. NOT USED

11. NOT USED

12. ELECTRIC STRIKE MOUNTED IN DOOR FRAME. WIRE STRIKE BACK TO THE RTE J-BOX USING 18/2 CONDUCTOR.

13. CONDUIT TO CABLE TRAY, CONDUIT SIZED PER LOCATION.

LEGEND:

J-BOX

NOTES:

CR CARD READER CONTRACTOR SHALL PROVIDE A 4"x4" RECESSED JUNCTION BOX W/ 2"x4" DEEP BOX ADJACENT TO DOOR. BOTTOM OF J-

BOX TO BE 5 FT. A.F.F.

JUNCTION BOX (6"x6"x4" MIN).

(TO ELEC. DOOR STRIKE J-

BOX,

SEE DETAIL BELOW)

COMM RM

PANEL (GFGI)

ACS CONTROL

2" C BACK TO

HOST PC

KEYPAD/CARD READER J-

BOX

(TYP.) (SEE DETAIL AT RIGHT)

3/4" C

(TYP.)

J-BOX

3/4" C (TYP.).

CR TYPICAL DOOR W/ ACS

110 VAC SUPPLY

DL TYPICAL DOOR W/ ACS

1. CONDUIT AND JUNCTION BOXES FOR POWER AND VIDEO FEED SHALL BE RUN FOR THE

GOVERNMENT INSTALLED CCTV SYSTEM.

2. PROVIDE PATHWAY AND SUPPORT IN ACCORDANCE WITH UFC 3-580-01

TELECOMMUNICATIONS INTERIOR INFRASTRUCTURE PLANNING AND DESIGN.

3. PROVIDE NYLON PULL ROPE IN ALL EMPTY CONDUITS.

US Army Corps of Engineers

SHEET ID

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

F

IL

E N

A M

E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

P R

O J E

C T

N U

M B

E R

A

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

D E

S C

R

IP

T

IO

N

T-604

W E

A P

O N

A L G

O R

IT

H

M R

E S

E A

R C

H F

A C

IL

IT

Y R

E S

E A

R C

H F

A C

IL

IT

Y

W A

R F

M o b ile

D is tr ic t L C

T A

M B

L Y

N

E N

D E

D D

C O

L L

IE

R

C P

G U

N N

N O

V E

M B

E R

W -X

X -X

-X X

X X

W -X

X -X

-X X

X X

M H

F

M H

F

FTFA-19JC03

E G

L

IN

A F

B F

L

S

A

IN

T J

O S

E P

H S

T R

E E

T M

O B

IL

E

A L

S Y

S T

E M

S R

IS

E

R S

A C

C E

S S

C O

N T

R O

L S

Y S

T E

M

N.T.S.

ACCESS CONTROL WITH KEYLESS DETAIL -

DOUBLE DOOR

N.T.S.

ACCESS CONTROL WITH KEYLESS DETAIL -

NOTES

N.T.S.

ACCESS CONTROL WITH KEYLESS DETAIL -

SINGLE DOOR

N.T.S.

ACS INFRASTRUCTURE RISER DIAGRAM

M A

R K

D A

T E

File details come from the government source that posted it. Updated .