Attachment_F_DRWGS_15R4020.pdf
PDF 9 MB Posted
- Attached to
- Repair HVAC & Interior Bldg. 3017 Federal contract opportunity
- Solicitation number
- FA2823-15-R-4020
About this file
Drawings 13BR
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| FA2823-15-R-4020_Amendment_3.pdf | ||
| FA2823-15-R-4020_Amendment_2.pdf | ||
| FA2823-15-R-4020_Consolidated_Q_ _A_090915.pdf | ||
| FA2823-15-R-4020_Consolidated_Q_ _A_090815.pdf | ||
| HVAC_Bldg_3017_Extension.pdf | ||
| FTFA_13-9005_Site_Visit_Sign_in_Sheet.pdf | ||
| Q_ _A_PART_1.docx | DOCX document | |
| Attachment_C_Financial_Responsibility.docx | DOCX document | |
| Attachment_G_WD_15R4020.pdf | ||
| Attachment_D_SOW.pdf | ||
| Attachment_J_Base_Support_Letter.pdf | ||
| Memorandum_Letter.doc | DOC document | |
| FA2823-15-R-4020_RFP_RELEASED.pdf | ||
| Attachment_E_SPECS_139005_15R4020.pdf | ||
| Attachment_I_Hold_Harmless_Agreement_Bldg_3017.pdf | ||
| Attachment_B_Past_Performance_Questionnaire.docx | DOCX document | |
| ATTACHMENT_E-Affidavit.pdf | ||
| Attachment_A_Past_Performance_References.docx | DOCX document |
Show all 18
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
D P R O J E C T
R e p a i r
H V A C a n d
I n t e r i o r
D i n i n g
H a l l
B l d g
D W G M e c h M d w g
P M
D W G
T o
P D F p c
ELECTRICAL PLAN - DEMOLITION - LIGHTING
SCALE: 1/8" = 1'-0"
ELECTRICAL LEGEND - DEMOLITION:
EXISTING COMPACT FLUORESCENT DOWNLIGHT - TO REMAIN - PROVIDE SUPPORT TO HOLD FIXTURE IN PLACE WHILE CEILING
IS DEMOLISHED AND REPLACED - ADJUST LOCATION OF EXISTING FIXTURE AS REQUIRED TO REINSTALL IN NEW CEILING.
EXISTING FLUORESCENT TROFFER - TO REMAIN - PROVIDE SUPPORT TO HOLD FIXTURE IN PLACE WHILE CEILING IS
DEMOLISHED AND REPLACED - ADJUST LOCATION OF EXISTING FIXTURE AS REQUIRED TO REINSTALL IN NEW CEILING.
EXISTING EXIT LIGHT - TO REMAIN - PROVIDE SUPPORT TO HOLD FIXTURE IN PLACE WHILE CEILING IS DEMOLISHED AND
REPLACED - REINSTALL FIXTURE ON NEW CEILING.
EXISTING COMPACT FLUORESCENT DOWNLIGHT - REMOVE AND RELOCATE, AS SHOWN ON NEW WORK PLAN.
EXISTING FLUORESCENT TROFFER - REMOVE.
EXISTING WALL SWITCH - REMOVE.
EXISTING CONDUIT & WIRING - TO REMAIN & BE REUSED, AS SHOWN ON NEW WORK PLAN.
EXISTING CONDUIT & WIRING - REMOVE.
F
F
S
V
J
M
EXISTING JUNCTION BOX - REMOVE.
EXISTING DUPLEX RECEPTACLE - TO REMAIN.
EXISTING DUPLEX RECEPTACLE - REMOVE.
EXISTING COMBINATION MOTOR STARTER/DISCONNECT SWITCH - REMOVE.
EXISTING MOTOR - REMOVE EXISTING ELECTRICAL CONNECTION.
EXISTING FLEXIBLE CONDUIT & WIRING CONNECTION - REMOVE.
EXISTING FIRE ALARM SYSTEM SPEAKER/STROBE - WALL MOUNTED - REMOVE.
EXISTING FIRE ALARM SYSTEM SPEAKER/STROBE - CEILING MOUNTED - REMOVE.
EXISTING PUBLIC ADDRESS SYSTEM SPEAKER - REMOVE & REINSTALL IN NEW CEILING.
EXISTING PUBLIC ADDRESS SYSTEM VOLUME CONTROL - REMOVE & REINSTALL IN NEW WALL.
H
EXISTING ELECTRIC STRIP HEAT - REMOVE EXISTING ELECTRICAL CONNECTION.
(APPLIES TO DRAWINGS E-1 AND E-2.)
FACP
EXISTING FIRE ALARM SYSTEM CONTROL PANEL - FIRE CONTROL INSTRUMENTS # 7200 - REMOVE.
VNP
TR
EXISTING FIRE ALARM SYSTEM VOICE NOTIFICATION PANEL - REMOVE.
EXISTING FIRE ALARM SYSTEM TRANSCEIVER - REMOVE.
GENERAL ELECTRICAL NOTE:
ALL ELECTRICAL WORK AND MATERIAL, UNLESS OTHERWISE NOTED, IS NEW AND SHALL BE
FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR.
PENSACOLA, FLORIDA 32502
75 SOUTH "F" STREET
PETERSON ENGINEERING INC.
(850) 434-0513
F
F
F
F
S
V
ELECTRICAL PLAN - DEMOLITION - POWER & AUXILIARY SYSTEMS
SCALE: 1/8" = 1'-0"
J
J
M
M
AHU-1
AHU-2
CWP
HWP
B-1
MU-4
MU-3
MU-2
MU-1
SF-5
SF-4
SF-3
ELECTRICAL PLAN - MEZZANINE - DEMOLITION
SCALE: 1/8" = 1'-0"
M
M
M
M
S
MEZZANINE, ABOVE. SEE "ELECTRICAL PLAN -
MEZZANINE - DEMOLITION," THIS SHEET.
SF-6
M
M
H
H
H
H
V
F
EXISTING PANEL "WEST" - REMOVE &
REINSTALL IN NEW WALL & RECONNECT
EXISTING BRANCH CIRCUITS AS SHOWN
ON "ELECTRICAL PLAN - NEW WORK -
POWER," SHEET E-4.
EXISTING PANEL "EAST" - REMOVE &
REINSTALL IN NEW WALL & RECONNECT
EXISTING BRANCH CIRCUITS AS SHOWN
ON "ELECTRICAL PLAN - NEW WORK -
POWER," SHEET E-4.
EXISTING PANEL "H1"
EXISTING PANEL "E1"
EXISTING PANEL "MDP1"
EXISTING PANEL "MDP2"
EXISTING PANEL "L2"
EXISTING PANEL "LP1"
T
EXISTING ELECTRICAL ROOM LAYOUT
SCALE: 1/8" = 1'-0"
FACP
TR
VNP
TEMPORARILY DISCONNECT EXISTING 120 V. POWER
CONNECTION FROM EXISTING BOILER & RECONNECT
TO NEW BOILER.
WORK NOTES:
REMOVE EXISTING CONDUIT & WIRING BACK TO EXISTING PANEL "MDP2."
2 REMOVE EXISTING CONDUIT & WIRING BACK TO EXISTING PANEL "MDP1."
PENSACOLA, FLORIDA 32502
75 SOUTH "F" STREET
ELECTRICAL PLAN - NEW WORK - LIGHTING
ELECTRICAL LEGEND - NEW WORK:
EXISTING COMPACT FLUORESCENT DOWNLIGHT - ADJUST LOCATION OF EXISTING FIXTURE AS REQUIRED TO REINSTALL IN
NEW CEILING - RECONNECT EXISTING FLEXIBLE CONDUIT WHIP & WIRING TO RELOCATED FIXTURE.
EXISTING FLUORESCENT TROFFER - ADJUST LOCATION OF EXISTING FIXTURE AS REQUIRED TO REINSTALL IN NEW GRID TEE
CEILING - RECONNECT EXISTING FLEXIBLE CONDUIT WHIP & WIRING TO RELOCATED FIXTURE.
EXISTING EXIT LIGHT - TO REMAIN - REINSTALL FIXTURE ON NEW GRID TEE CEILING.
EXISTING COMPACT FLUORESCENT DOWNLIGHT - REINSTALL IN NEW LOCATION & PROVIDE NEW CONDUIT & WIRING, AS SHOWN.
WALL SWITCH - QUIET TYPE - 20 A., 120/277 V., 1 POLE - MTD. 48" A.F.F. TO TOP OF BOX.
EXISTING CONDUIT & WIRING - TO REMAIN & BE REUSED, AS SHOWN ON NEW WORK PLAN.
M
JUNCTION BOX - SIZE AS REQUIRED - CONCEAL ABOVE NEW GRID TEE CEILING.
EXISTING DUPLEX RECEPTACLE - TO REMAIN.
DUPLEX RECEPTACLE - 20 A., 125 V., 2 P., 3 W. - MTD. 18" A.F.F. TO CENTER OF BOX.
MOTOR - FURNISHED BY MECHANICAL CONTRACTOR - CONNECTION BY ELECTRICAL CONTRACTOR.
LIQUID-TIGHT FLEXIBLE CONDUIT & WIRING CONNECTION.
NOTE: TICKMARKS INDICATE NO. OF CONDUCTORS; " " INDICATES FULL SIZE GROUND CONDUCTOR; ARROW INDICATES
HOMERUN TO PANEL; "LP:1" INDICATES PANEL AND CIRCUIT NO.; WIRE IS # 12; CONDUIT IS 1/2" & BREAKER IS 20 A., 1 P., UNLESS NOTED OTHERWISE. ( INDICATES CONCEALED OVERHEAD OR IN WALLS; INDICATES CONCEALED IN
EXISTING PANELBOARD - TO REMAIN.
BRANCH CIRCUIT CONDUIT & WIRING:
OR BELOW FLOOR; INDICATES EXPOSED.)
LP:1
BRANCH CIRCUIT CONDUIT & WIRING:
CONDUIT IS 1/2", UNLESS NOTED OTHERWISE. ( INDICATES CONCEALED OVERHEAD OR IN WALLS; INDICATES EXPOSED.)
NOTE: TICKMARKS INDICATE NO. OF CONDUCTORS; " " INDICATES FULL SIZE GROUND CONDUCTOR; WIRE IS # 12;
MOTOR STARTER - FURNISHED BY MECHANICAL CONTRACTOR - CONNECTION BY ELECTRICAL CONTRACTOR.
DISCONNECT SWITCH - HEAVY DUTY - NON-FUSIBLE.
EXISTING COMPACT FLUORESCENT DOWNLIGHT - TO REMAIN.
J
J
J
J
E
E
E
E
E
E
E
EXISTING BRANCH CIRCUIT CONDUIT & WIRING - INTERCEPT EXISTING CONDUIT & PULL IN NEW WIRING.
EXISTING HOMERUN TO PANEL "H1" TO REMAIN.
(APPLIES TO DRAWINGS E-3, E-4 AND E-5.)
EXISTING HOMERUN TO PANEL "H1" TO REMAIN.
E
EXISTING HOMERUN TO PANEL "H1" TO REMAIN.
R
R
R
T
EXISTING DRY-TYPE TRANSFORMER - TO REMAIN.
EXISTING ELECTRICAL ROOM LAYOUT
SCALE: 1/8" = 1'-0"
E
J
E
E
J1
WORK NOTES:
INSTALL WALL SWITCH IN EXISTING WALL. CUT & PATCH EXISTING WALL AND CEILING AS
REQUIRED TO INSTALL NEW SWITCH AND ASSOCIATED CONDUIT & WIRING.
2 INTERCEPT EXISTING CONDUIT, INSTALL JUNCTION BOX ABOVE CEILING, SPLICE EXISTING
WIRING TO NEW WIRING & EXTEND NEW CIRCUIT TO NEW WALL SWITCH.
TOGGLE TYPE DISCONNECT SWITCH - HORSEPOWER RATED - MOUNT ADJACENT TO MOTOR BEING SERVED.
EXISTING PANEL "H1"
EXISTING PANEL "E1"
EXISTING PANEL "MDP1"
EXISTING PANEL "MDP2"
EXISTING PANEL "L2"
EXISTING PANEL "LP1"
T
PENSACOLA, FLORIDA 32502
75 SOUTH "F" STREET
ELECTRICAL PLAN - NEW WORK - POWER
J
J J
M
M
M
M
M
M
ELECTRICAL PLAN - MEZZANINE - NEW WORK - POWER
SCALE: 1/8" = 1'-0"
J
J
MEZZANINE, ABOVE. SEE "ELECTRICAL PLAN -
MEZZANINE - NEW WORK - POWER," THIS SHEET.
EXISTING PANEL "WEST" - REINSTALL IN NEW WALL & RECONNECT
EXISTING BRANCH CIRCUITS. INSTALL NEW FEEDER (4 # 1 & 1 # 6
GND. - 2" C.) BACK TO EXISTING SWITCH IN ELECTRICAL ROOM.
EXISTING PANEL "EAST" - REINSTALL IN NEW WALL & RECONNECT
EXISTING BRANCH CIRCUITS. INSTALL NEW FEEDER (4 # 1 & 1 # 6
GND. - 2" C.) BACK TO EXISTING SWITCH IN ELECTRICAL ROOM.
E
EXISTING HOMERUN TO PANEL "L2" TO REMAIN.
M
M
B-1
M
M
SEE "LARGE SCALE PLAN - MECHANICAL
EQUIPMENT ROOMS," THIS SHEET.
LARGE SCALE PLAN - MECHANICAL EQUIPMENT ROOMS
SCALE: 1/4" = 1'-0"
EXISTING PANEL "H1"
EXISTING PANEL "E1"
EXISTING PANEL "MDP1"
EXISTING PANEL "MDP2"
EXISTING PANEL "L2"
EXISTING PANEL "LP1"
T
EXISTING ELECTRICAL ROOM LAYOUT
SCALE: 1/8" = 1'-0"
DIT
BOILER PUMP
1 1/2 HP, 208 V., 3Ø
CHWP-1
5 HP, 480 V., 3Ø
HWP-1
2 HP, 480 V., 3Ø
AHU-1
7 1/2 HP, 480 V., 3Ø
AHU-2
7 1/2 HP, 480 V., 3Ø
LDCU-1
FANS (2) 0.77 A., 480 V., 3Ø
HP-1
COMPR. (2) 16.7 RLA, 480 V., 3Ø
FANS (4) 0.8 FLA, 480 V., 3Ø
LDCU-2
FANS (2) 0.77 A., 480 V., 3Ø
LDU-2
(2) 4 HP, 480 V., 3Ø
MU-2
3 HP, 480 V., 3Ø
LDU-1
(2) 4 HP, 480 V., 3Ø
MU-1
3 HP, 480 V., 3Ø
M
M
HP-2
COMPR. (2) 16.7 RLA, 480 V., 3Ø
FANS (4) 0.8 FLA, 480 V., 3Ø
30 A., 3 P., NEMA 3R
30 A., 3 P., NEMA 3R
60 A., 3 P., NEMA 3R
60 A., 3 P., NEMA 3R
30 A., 3 P., NEMA 1
30 A., 3 P., NEMA 1
60 A., 3 P., NEMA 1
60 A., 3 P., NEMA 1
30 A., 3 P., NEMA 1
30 A., 3 P., NEMA 1
11 KVA, 3Ø DRIVE ISOLATION TRANSFORMER -
WALL MOUNTED ABOVE DISCONNECT SWITCH
AND VARIABLE FREQUENCY DRIVE.
30 A., 3 P., NEMA 1
30 A., 3 P., NEMA 1
E
WORK NOTES:
INTERCEPT EXISTING BRANCH CIRCUITS ABOVE LAY-IN CEILING, INSTALL JUNCTION BOX, SPLICE CONDUCTORS &
EXTEND NEW HOMERUN TO (3) EXISTING 20 A., 1 P. BKRS. IN EXISTING PANEL "WEST." (CIRCUIT # 1/3/5)
2 INTERCEPT EXISTING BRANCH CIRCUITS ABOVE LAY-IN CEILING, INSTALL JUNCTION BOX, SPLICE CONDUCTORS &
EXTEND NEW HOMERUN TO (2) EXISTING 20 A., 1 P. BKRS. IN EXISTING PANEL "WEST." (CIRCUIT # 7/9 AND 2/4)
3 INTERCEPT EXISTING BRANCH CIRCUITS ABOVE LAY-IN CEILING, INSTALL JUNCTION BOX, SPLICE CONDUCTORS &
EXTEND NEW HOMERUN TO (3) EXISTING 20 A., 1 P. BKRS. IN EXISTING PANEL "EAST." (CIRCUIT # 1/3/5 AND 2/4/6)
4 INTERCEPT EXISTING BRANCH CIRCUITS ABOVE LAY-IN CEILING, INSTALL JUNCTION BOX, SPLICE CONDUCTORS &
EXTEND NEW HOMERUN TO (2) EXISTING 20 A., 1 P. BKRS. IN EXISTING PANEL "EAST." (CIRCUIT 7/9)
5 INTERCEPT EXISTING BRANCH CIRCUITS ABOVE LAY-IN CEILING, INSTALL JUNCTION BOX, SPLICE CONDUCTORS &
EXTEND NEW HOMERUN TO (1) EXISTING 20 A., 2 P. BKR. IN EXISTING PANEL "EAST." (CIRCUIT 20/22)
EDH-2
15 KW, 480 V., 3Ø
EDH-1
15 KW, 480 V., 3Ø
30 A., 3 P., NEMA 1 - MOUNT ABOVE
CEILING ADJACENT TO DUCT HEATER.
30 A., 3 P., NEMA 1 - MOUNT ABOVE
CEILING ADJACENT TO DUCT HEATER.
HOMERUN TO EXISTING 20 A., 1 P. SPARE
BKR. IN EXISTING PANEL "EAST," CKT. # 8.
HOMERUN TO EXISTING 20 A., 1 P. SPARE
BKR. IN EXISTING PANEL "WEST," CKT. # 12.
EXTEND TO LDU-1 ON MEZZANINE.
EXTEND TO LDU-2 ON MEZZANINE.
EXTEND TO LDCU-1 OUTSIDE.
EXTEND TO LDCU-2 OUTSIDE.
J
INSTALL FLOOR OUTLET W/ DUPLEX RECEPTACLE IN EXISTING CONCRETE
FLOOR. CUT & PATCH EXISTING CONCRETE FLOOR AS REQUIRED TO
INSTALL FLOOR BOX AND CONDUIT & WIRING. VERIFY EXACT LOCATION
W/ CONTRACTING OFFICER AND USER IN FIELD PRIOR TO INSTALLATION.
J
WP
120 V. CONNECTION FOR
CHILLER PIPING HEAT TAPE.
M
HOMERUN TO EXISTING 20 A., 1 P. SPARE
BREAKER IN PANEL "WEST," CKT. # 10.
EXISTING 400 A., 3 P., NEMA 3R
DISCONNECT SWITCH TO
REMAIN. EXTEND NEW 3 # 4/0 & 1
# 4 GND. IN 2" LIQUID TIGHT
FLEXIBLE METAL CONDUIT TO
NEW CHILLER.
EXISTING 100 A., 3 P. DISCONNECT SWITCH MTD. ABOVE
EXISTING DOOR SERVES EXISTING PANEL "WEST." EXTEND
NEW FEEDER (4 # 1 & 1 # 6 GND. - 2" C.) FROM EXISTING
DISCONNECT SWITCH TO RELOCATED PANEL "WEST."
EXISTING 100 A., 3 P. DISCONNECT SWITCH MTD. ABOVE
EXISTING DOOR SERVES EXISTING PANEL "EAST." EXTEND
NEW FEEDER (4 # 1 & 1 # 6 GND. - 2" C.) FROM EXISTING
DISCONNECT SWITCH TO RELOCATED PANEL "EAST."
J
J
6 HOMERUN FROM NEW HOOD SUPPRESSION SYSTEM CONTROL PANELS TO (2) EXISTING 20 A., 1 P. BKRS. IN EXISTING
PANEL "WEST." (CIRCUIT # 6/8)
7 HOMERUN TO EXISTING 20 A., 1 P. BKR. IN EXISTING PANEL "WEST." (CIRCUIT # 11)
HOMERUN TO EXISTING 20 A., 1 P. BKR.
IN PANEL "L2," CKT. # 16.
30 A., 3 P., NEMA 1
HOMERUN TO EXISTING 25 A., 3 P. BKR. IN
EXISTING PANEL "MDP-1."
HOMERUN TO EXISTING 15 A., 3 P. BKR. IN
EXISTING PANEL "MDP-1."
HOMERUN TO EXISTING 15 A., 3 P.
BKR. IN PANEL "MDP2," CKT. # 16.
HOMERUN TO EXISTING 15 A., 3 P.
BKR. IN PANEL "MDP2," CKT. # 18.
HOMERUN 3 # 6 & 1 # 8 GND. - 1" C. TO 50 A., 3 P. BKR. IN
PANEL "MDP1," CKT. # 9. REMOVE EXISTING 90 A., 3 P. BKR.
& INSTALL 50 A., 3 P. BKR. IN EXISTING SIEMENS S5 PANEL.
HOMERUN 3 # 6 & 1 # 8 GND. - 1" C. TO 50 A., 3 P. BKR. IN
PANEL "MDP1," CKT. # 10. REMOVE EXISTING 100 A., 3 P. BKR.
& INSTALL 50 A., 3 P. BKR. IN EXISTING SIEMENS S5 PANEL.
8 HOMERUN 3 # 6 & 1 # 8 GND. - 1" C. TO 50 A., 3 P. BKR. IN PANEL "MDP2" CKT. # 20. REMOVE
EXISTING 15 A., 3 P. BKR. & INSTALL 50 A., 3 P. BKR. IN EXISTING SIEMENS S5 PANEL
9 HOMERUN 3 # 6 & 1 # 8 GND. - 1" C. TO 50 A., 3 P. BKR. IN PANEL "MDP2" CKT. # 22. REMOVE
EXISTING 15 A., 3 P. BKR. & INSTALL 50 A., 3 P. BKR. IN EXISTING SIEMENS S5 PANEL
10 HOMERUN 3 # 10 & 1 # 10 GND. - 3/4" C. TO 30 A., 3 P. BKR. IN PANEL "MDP2" CKT. # 29. REMOVE
EXISTING 40 A., 3 P. BKR. & INSTALL 30 A., 3 P. BKR. IN EXISTING SIEMENS S5 PANEL
11 HOMERUN 3 # 10 & 1 # 10 GND. - 3/4" C. TO 30 A., 3 P. BKR. IN PANEL "MDP2" CKT. # 30. REMOVE
EXISTING 40 A., 3 P. BKR. & INSTALL 30 A., 3 P. BKR. IN EXISTING SIEMENS S5 PANEL
J
J
J
J
HOMERUN TO EXISTING 20 A., 1 P. SPARE
BKR. IN EXISTING PANEL "EAST," CKT. # 10.
CUT & PATCH EXISTING GYP. BOARD WALL
FOR RECEPTACLE AND CONDUIT & WIRING
INSTALLATION. (TYP.)
INSTALL JUNCTION BOXES FOR NEW
RECEPTACLE CIRCUIT ABOVE EXISTING
LAY-IN CEILING (TYP.)
J
J
CUT & PATCH EXISTING GYP. BOARD
WALL FOR RECEPTACLE AND CONDUIT
& WIRING INSTALLATION. (TYP.)
INSTALL JUNCTION BOXES FOR NEW
RECEPTACLE CIRCUIT ABOVE
EXISTING LAY-IN CEILING (TYP.)
HOMERUN TO EXISTING 20 A., 1 P. SPARE
BKR. IN EXISTING PANEL "WEST," CKT. # 13.
DISCONNECT EXISTING ELECTRICAL
CONNECTION TO EXISTING EF-5 &
RECONNECT TO NEW EXHAUST FAN.
PENSACOLA, FLORIDA 32502
75 SOUTH "F" STREET
ELECTRICAL PLAN - NEW WORK - AUXILIARY SYSTEMS
F
F
F
PA
S
R
S
R S
T
F
F
F
F
F
F
F
F
F
F
F F
F F F
F F F
F
F
FF
F
F
F
F
FF
F
F
S
S
S
S
SS
S
S
SS
S
SS
S
S S
S S
S
SSS
S
S
S
S
S
S
S
V
F
F
FACP
F
F
FSCP-1
FSCP-2
TR
J
P
A
P A
P
A
P
A
L
O
C
AUXILIARY SYSTEMS LEGEND - NEW WORK:
S
V
EXISTING FIRE ALARM SYSTEM SPEAKER/STROBE - WALL MOUNTED - INSTALL NEW FIRE ALARM STROBE IN EXISTING BOX.
EXISTING FIRE ALARM SYSTEM SPEAKER/STROBE - CEILING MOUNTED - INSTALL NEW FIRE ALARM STROBE.
EXISTING PUBLIC ADDRESS SYSTEM VOLUME CONTROL - REINSTALL IN NEW WALL - MOUNT 48" A.F.F. TO TOP OF BOX.
F
F
F
S
EXISTING PUBLIC ADDRESS SYSTEM SPEAKER - REINSTALL IN NEW GRID TEE CEILING.
EXISTING FIRE ALARM SYSTEM SPEAKER/STROBE - CEILING MOUNTED - INSTALL NEW FIRE ALARM STROBE.
MNSP
LOC
MASS NOTIFICATION SYSTEM - CONTROL PANEL - SEE RISER DIAGRAM.
MASS NOTIFICATION SYSTEM - SPEAKER/AMBER STROBE - CEILING MOUNTED.
MASS NOTIFICATION SYSTEM - LOCAL OPERATORS CONSOLE UNIT - FURNISH UNIT W/ HVAC EMERGENCY SHUTOFF - RED MUSHROOM TYPE CUTOFF
PUSHBUTTON W/ LABELING.
PA
PUBLIC ADDRESS SYSTEM - CONDUIT & WIRING.
FACP
FIRE ALARM SYSTEM CONTROL PANEL - SEE "FIRE ALARM RISER DIAGRAM," SHEET E-7.
(APPLIES TO DRAWINGS E-5 AND E-6.)
EXISTING PUBLIC ADDRESS SYSTEM SPEAKER - RELOCATE TO POSITION SHOWN - EXTEND P.A. CIRCUIT CONDUIT & WIRING TO
RELOCATED SPEAKER AS INDICATED ON "ELECTRICAL PLAN - NEW WORK - AUXILIARY SYSTEMS," SHEET E-5.
TR
FIRE ALARM SYSTEM TRANSCEIVER - SEE "FIRE ALARM RISER DIAGRAM," SHEET E-7.
F
EXISTING FIRE ALARM SYSTEM PULL STATION - WALL MOUNTED - INSTALL NEW PULL STATION IN EXISTING BOX.
S
FIRE ALARM SYSTEM DUCT SMOKE DETECTOR - PHOTO-ELECTRIC TYPE - "S" = SUPPLY; "R" = RETURN.
MASS NOTIFICATION SYSTEM - CONDUIT & WIRING - 3/4" C. MINIMUM.
M
N
MASS NOTIFICATION SYSTEM - SPEAKER/AMBER STROBE - WALL MOUNTED 80" A.F.F. TO BOTTOM OF BOX.
MNSP
PA
EXISTING PUBLIC ADDRESS SYSTEM CONSOLE - TO REMAIN.
T
F
FIRE ALARM CONNECTION TO SPRINKLER SYSTEM FLOW SWITCH.
FIRE ALARM CONNECTION TO SPRINKLER SYSTEM TAMPER SWITCH.
INSTALL A KNOX BOX MODEL
3200 WITHOUT TAMPER SWITCH
ON EXTERIOR WALL.
F
V
P
A
CUT & PATCH EXISTING WALL & CEILING AS REQUIRED TO
INSTALL VOLUME CONTROL SWITCH IN NEW LOCATION &
CONNECT TO EXISTING SPEAKER.
PROVIDE A REMOTE ANNUNCIATOR AT THE DESIGNATED PRIMARY ENTRANCE.
PROVIDE REMOTE ANNUNCIATOR WITH CONTROL FUNCTIONS THE SAME AS THE
MAIN CONTROL PANEL. CONTROL FUNCTIONS SHALL BE ACCESSIBLE ONLY BY
USER CODE OR SECURED BEHIND A LOCKED PANEL.
FIRE ALARM ANNUNCIATOR NOTE:
F
FIRE ALARM SYSTEM - CONDUIT & WIRING.
CUT & PATCH EXISTING CEILING AS REQUIRED TO INSTALL
NEW FIRE ALARM STROBE IN NEW FURRED OUT WALL
ANN
FIRE ALARM SYSTEM ANNUNCIATOR - SEE "FIRE ALARM ANNUNCIATOR NOTE," THIS SHEET.
R
FIRE ALARM SYSTEM AHU SHUT DOWN RELAY.
MEZZANINE, ABOVE. SEE "ELECTRICAL PLAN -
MEZZANINE," THIS SHEET.
ELECTRICAL PLAN - MEZZANINE
SCALE: 1/8" = 1'-0"
R
R
CUT & PATCH EXISTING CEILING AS
REQUIRED TO INSTALL ANNUNCIATOR
AND CONDUIT & WIRING.
CUT & PATCH EXISTING CEILING AS REQUIRED TO
INSTALL LOC AND CONDUIT & WIRING.
T
FIRE ALARM SHOP DRAWINGS SHALL BE SUBMITTED FOR REVIEW AND APPROVAL
PRIOR TO ANY WORK IN ACCORDANCE WITH UFC 3-600-01, CHAPTER 5 AND NFPA 72,
PARAGRAPH 10.4.
FIRE ALARM SHOP DRAWINGS NOTE:
M
FIRE ALARM SYSTEM MONITOR MODULE.
MOUNT MONITOR MODULE ADJACENT TO WET CHEMICAL
SUPPRESSION SYSTEM CONTROL PANEL
MOUNT MONITOR MODULE ADJACENT TO WET
CHEMICAL SUPPRESSION SYSTEM CONTROL PANEL
PENSACOLA, FLORIDA 32502
75 SOUTH "F" STREET
FIRE ALARM/MASS NOTIFICATION RISER DIAGRAM
BATTERIES
MNSP
MONACO BT-X TRANSCEIVER W/ 141.3625 MHZ
FREQUENCY & LIVE VOICE CAPABILITIES
NOT TO SCALE
BATTERIES
FACP
F
WIRING & CONDUIT AS REQD.
BY SYSTEM
F
ADDRESSABLE INTELLIGENT
FIRE ALARM CONTROL PANEL
SSSS
EXTERIOR WALL
EXISTING WEATHERHEAD
EXISTING ANTENNA
TRANSCEIVER ZONES:
WORK NOTES:
(TYP.)
20 # 14 - 1/2" C.EXISTING LOW LOSS COAX CABLE IN 1"C. -
RECONNECT TO NEW TRANSCEIVER.
EXISTING
LIGHTNING
ARRESTER
EXISTING GROUND
CONDUCTOR CONNECTION
TO EXISTING GROUND ROD.
EXISTING GROUND CONNECTION
TO MAIN SERVICE
RECONNECT EXISTING FIRE ALARM CIRCUITS TO NEW
CONTROL PANEL. PULL NEW WIRING (IF REQUIRED BY THE
NEW SYSTEM) IN EXISTING CONDUITS TO NEW DEVICES.
2 # 16 AWG STRANDED, TWISTED PAIR FOR FIRE ALARM SIGNALLING
LINE CIRCUIT. SLC SHALL BE INSTALLED IN A LOOPED CONDUIT
SYSTEM. SEE SPECIFICATION SECTION 28 31 76.
2 # 14 AWG THHN FOR NOTIFICATION APPLIANCE CIRCUIT & 2 # 16
AWG UNSHIELDED PAIR FOR MASS NOTIFICATION SPEAKER LOOP.
NAC AND SPEAKER CIRCUITS SHALL BE INSTALLED IN A LOOPED
CONDUIT SYSTEM. SEE SPECIFICATION SECTION 28 31 76.
TIE INTO EXISTING P.A. SYSTEM SO THAT
MASS NOTIFICATION SYSTEM OVERRIDES P.A.
SYSTEM. INSTALL RELAY AT EXISTING P.A.
SYSTEM FOR OVERRIDE CONNECTION.
S
ZONE 1 PULL STATIONS
ZONE 2 SMOKE DETECTOR
ZONE 3 DUCT SMOKE DETECTORS
ZONE 4 KITCHEN HOOD FIRE SUPPRESSION CONTROL PANEL # 1
ZONE 5 KITCHEN HOOD FIRE SUPPRESSION CONTROL PANEL # 2
ZONE 6 SPRINKLER FLOW
ZONE 7 SPRINKLER TAMPERS
ZONE 8 SERVING LINE HOOD WET CHEMICAL HOOD SYSTEMS
ZONE 9 FIRE ALARM SYSTEM TROUBLE
ZONE 10 MASS NOTIFICATION SYSTEM TROUBLE
INTERCEPT EXISTING 120 V. CIRCUIT FEEDING EXISTING FACP & PROVIDE
IN-LINE SERIES SURGE SUPPRESSOR. MOUNT SUPPRESSOR AS CLOSE
TO PANEL AS POSSIBLE.
INTERCEPT EXISTING 120 V. CIRCUIT FEEDING EXISTING VOICE PANEL &
PROVIDE IN-LINE SERIES SURGE SUPPRESSOR. MOUNT SUPPRESSOR AS
CLOSE TO PANEL AS POSSIBLE.
LOC
CONNECT TO AIR HANDLING UNIT MOTOR STARTER FOR SHUT DOWN.
SEE "AHU SHUTDOWN DIAGRAM," THIS SHEET.
FRM-1
ADDRESS
ONES
TENS
LOOP
RELAY
COMMON 2
NORMALLY
CLOSED 2
NORMALLY
OPEN 2
RELAY
COMMON 1
NORMALLY
CLOSED 1
NORMALLY
OPEN 1
ADDRESSABLE FIRE ALARM
CONTROL PANEL "FACP"
AUXILIARY FORM
"C" CONTACTS
AUX
DC
AHU SHUTDOWN DIAGRAM
NOT TO SCALE
FIRE ALARM SYSTEM MICROPROCESSOR-BASED ADDRESSABLE
CONTROL RELAY MODULE (FOR FAN MOTOR SHUTDOWN)
MOUNTED IN 4" SQ. X 2 1/8" DEEP DEVICE BOX. RELAY SHALL
PROVIDE TWO FORM "C" DRY RELAY CONTACTS RATED 2 AMPS
AT 24 VDC AND HAVE NOMINAL OPERATING VOLTAGE OF 15 TO
32 VDC WITH A MAXIMUM CURRENT DRAW OF 6.5 mA
SIGNALLING LINE
CIRCUIT (SLC) LOOP
2#16, 3/4"C.
DATA IN (+)
T3
T3
T2
T1
T2
T1
M
AHU MOTOR
STARTER
STOP
CONTROL
INPUT
MOTOR REQUIREMENTS VARY FOR
ALL EQUIPMENT SUPPLIED. SEE
PLANS FOR ACTUAL MOTOR
HORSEPOWER, VOLTAGE & PHASE
DATA IN (-)
DATA OUT (+) DATA OUT (-)
SIGNALLING LINE
CIRCUIT (SLC) LOOP
2#16, 3/4"C.
TO NEXT
DEVICE OR
"FACP"
2#14, 1/2"C. (VERIFY
WITH EQUIPMENT
MANUFACTURER)
R RR S R
F T T
HOOD SUPPRESSION
SYSTEM CONTROL PANEL
F
MONITOR MODULE FOR HOOD
SUPPRESSION SYSTEM
CONNECT TO AUXILIARY CONTACTS IN HOOD
CONTROL PANEL TO SIGNAL FIRE ALARM CONTROL
PANEL IF THE SUPPRESSION SYSTEM DISCHARGES.
LAY IN CEILING
FIRE ALARM SYSTEM
CONDUIT & WIRING
DETAIL - HOOD SUPPRESSION SYSTEM CONNECTION
N.T.S.
CONNECT TO SHUNT TRIP CIRCUIT BREAKER IN PANEL "MDP1," CKT. # 2.
CONNECT TO SHUNT TRIP CIRCUIT BREAKER IN PANEL "MDP1," CKT. # 3.
CONNECT TO SHUNT TRIP CIRCUIT BREAKER IN PANEL "MDP-2," CKT. # 12.
CONNECT TO ALARM CONTACTS IN EXISTING FIRE SUPPRESSION CONTROL PANEL.
CONNECT TO ALARM CONTACTS IN NEW WET CHEMICAL SYSTEM CONTROL PANEL.
CONNECT TO LIQUID DESSICANT UNIT MOTOR STARTER FOR SHUT
DOWN. SEE "AHU SHUTDOWN DIAGRAM," THIS SHEET.
CONNECT TO SHUNT TRIP CIRCUIT BREAKER IN PANEL "LP1," CKT. # 27,29.
CONNECT TO SHUNT TRIP CIRCUIT BREAKER IN PANEL "LP1," CKT. # 31,33.
CONNECT TO SHUNT TRIP CIRCUIT BREAKER IN PANEL "LP1," CKT. # 35,37.
CONNECT TO SHUNT TRIP CIRCUIT BREAKER IN PANEL "LP1," CKT. # 24,26.
CONNECT TO SHUNT TRIP CIRCUIT BREAKER IN PANEL "LP1," CKT. # 28,30.
CONNECT TO SHUNT TRIP CIRCUIT BREAKER IN PANEL "LP1," CKT. # 32,34.
CONNECT TO SHUNT TRIP CIRCUIT BREAKER IN PANEL "LP1," CKT. # 50,52.
MOUNT LOC 44" ABOVE FINISHED FLOOR
(MAX.) TO TOP MESSAGE BUTTON.
MOUNT ANNUNCIATOR 60" ABOVE FINISHED
FLOOR (MAX.) TO TOP OF ENCLOSURE.
MOUNT FACP AND MNSP 70" (MAX.)
TO TOP OF ENCLOSURES.
MOUNT TRANSCEIVER 60" (MAX.)
TO TOP OF ENCLOSURE.
PENSACOLA, FLORIDA 32502
75 SOUTH "F" STREET
ELECTRICAL ROOF PLAN
WORK NOTES:
EXISTING ALUMINUM LIGHTNING PROTECTION SYSTEM ROOF CONDUCTOR.
2 EXISTING ALUMINUM AIR TERMINAL.
3 NEW ALUMINUM LIGHTNING PROTECTION SYSTEM ROOF CONDUCTOR.
4 NEW LIGHTNING PROTECTION SYSTEM MECHANICAL CONNECTOR FOR WIRE TO WIRE
CONNECTIONS.
5 BOND ALUMINUM CONDUCTOR TO CATWALK FRAME WITH BONDING CONNECTOR.
EXISTING EXHAUST FAN (TYP.)
NEW CATWALK SYSTEM (TYP.)
34 5
34 5
LIGHTNING PROTECTION SYSTEM NOTES:
1. ALL WORK SHALL BE IN COMPLIANCE WITH NFPA 780.
2. ALL MATERIALS SHALL BE IN COMPLIANCE WITH NFPA 780 AND UL 96.
3. ALUMINUM ROOF CONDUCTORS SHALL BE 98,600 CIRCULAR MILS WITH A MINIMUM STRANDING OF
14 AWG, AND A WEIGHT OF 95 LBS./1000 FEET. CONDUCTORS SHALL BE ATTACHED TO THE ROOF
WITH CABLE CLAMPS LOCATED 3'-0" ON CENTER (MAXIMUM).
3. WIRE TO WIRE CONNECTORS SHALL BE IN ACCORDANCE WITH DETAILS SHOWN ON THIS SHEET.
4. BONDING CONNECTORS SHALL BE IN ACCORDANCE WITH DETAILS SHOWN ON THIS SHEET.
5. ROOF CONDUCTOR BENDS SHALL BE MADE WITH A MINIMUM RADIUS OF 8".
DETAIL - BONDING CONNECTOR
N.T.S.
5/8" MOUNTING HOLE FOR
MECHANICALLY SECURING
PLATE TO EQUIPMENT
(TYP. OF 2 PER PLATE)
ALUMINUM BONDING PLATE - 3 SQ.
INCH CONTACT SURFACE.
ALUMINUM ROOF CONDUCTOR
BOILER FLUE
DETAIL - WIRE TO WIRE CONNECTIONS
N.T.S.
PARALLEL CONNECTORCROSS RUN CONNECTOR
ALUMINUM ROOF CONDUCTOR
ALUMINUM CONNECTOR
ALUMINUM CONNECTOR
ALUMINUM ROOF CONDUCTOR
ALUMINUM ROOF CONDUCTOR
PENSACOLA, FLORIDA 32502
75 SOUTH "F" STREET
| 01 FTFA 13-9005 T001 |
| 02 FTFA 13-9005 S001 |
| 03 FTFA 13-9005 S100 |
| 04 FTFA 13-9005 S101 |
| 05 FTFA 13-9005 S102 |
| 06 FTFA 13-9005 S103 |
| 07 FTFA 13-9005 S301 |
| 08 FTFA 13-9005 AD101 |
| 09 FTFA 13-9005 AD102 |
| 10 FTFA 13-9005 A101 |
| 11 FTFA 13-9005 A102 |
| 12 FTFA 13-9005 A103 |
| 13 FTFA 13-9005 A301 |
| 14 FTFA 13-9005 A401 |
| 15 FTFA 13-9005 I101 |
| 16 FTFA 13-9005 I102 |
| 17 FTFA 13-9005 I103 |
| 18 FTFA 13-9005 I104 |
| 19 FTFA 13-9005 P101 |
| 20 FTFA 13-9005 P102 |
| 21 FTFA 13-9005 M001 |
| 22 FTFA 13-9005 M101 |
| 23 FTFA 13-9005 M102 |
| 24 FTFA 13-9005 M111 |
| 25 FTFA 13-9005 M121 |
| 26 FTFA 13-9005 M401 |
| 27 FTFA 13-9005 M402 |
| 28 FTFA 13-9005 M501 |
| 29 FTFA 13-9005 M502 |
| 30 FTFA 13-9005 M503 |
| 31 FTFA 13-9005 M504 |
| 32 FTFA 13-9005 M601 |
| 33 FTFA 13-9005 M602 |
| 34 FTFA 13-9005 M701 |
| 35 FTFA 13-9005 M702 |
| 36 FTFA 13-9005 M703 |
| 37 FTFA 13-9005 M704 |
| 38 FTFA 13-9005 M705 |
| 39 FTFA 13-9005 E1 |
| 40 FTFA 13-9005 E2 |
| 41 FTFA 13-9005 E3 |
| 42 FTFA 13-9005 E4 |
| 43 FTFA 13-9005 E5 |
| 44 FTFA 13-9005 E6 |
| 45 FTFA 13-9005 E7 |
File details come from the government source that posted it. Updated .