3 TES RM 308 Floor Plan.pptx
PPTX presentation 288 KB Posted
- Attached to
- 3 TES Furniture Room 308
- Solicitation number
- FA255026Q0018
About this file
This is a floor plan document for Room 308 at Schriever Space Force Base detailing the spatial layout and furniture configuration requirements for the 3 TES (Tactical Exploitation Squadron) facility. The plan specifies that the current center wall and upper office must be removed to accommodate the new layout. Room 308 is divided into four sections: Rooms 308A, 308B, and 308C will contain executive-style L-shaped furniture with credenzas, while Room 308D will be configured with workstations. The floor plan indicates placement of a NIPR printer, NIPR laptop, tower display case, break table, circle table, D-shaped meeting table, NIPR phone, and kitchen facilities with lower cabinets and laminate countertop. Fire suppression systems must be installed in every enclosed room, and the government will furnish and install all communications equipment and data lines. Data drops and duplex outlets can be positioned within plus or minus three feet of the indicated locations, and the design may be modified to avoid conflicts with lights, HVAC, or fire suppression systems. The floor plan includes ceiling tile and fire suppression system layouts, with flexibility noted for adjustments based on government-installed infrastructure requirements.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 0610 3TES Furniture Questions and Answers.xlsx | XLSX spreadsheet | |
| Copy of Questions and Answers 3 TES Furniture.xlsx | XLSX spreadsheet | |
| FA255026Q00180001.pdf | ||
| 3TES room 308 Questions and Answers.xlsx | XLSX spreadsheet | |
| Attachment 2-3 TES Room 308 Salient Characteristics v2.pdf | ||
| Copy of Questions and Answers 3 TES Furniture.xlsx | XLSX spreadsheet | |
| Solicitation - FA255026Q0018.pdf | ||
| Attachment 4-Price Schedule.xlsx | XLSX spreadsheet | |
| Attachment 2-3 TES Room 308 Salient Characteristics.pdf | ||
| Attachment 3- 3 TES RM 308 Floor Plan.pdf | ||
| Attachment 1-3 TES Room 308 Furniture Statement of Work.pdf |
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Current Layout
- Center wall needs to be removed, and upper office needs to be removed N S
308A
308B
308C
- Fire Suppression (must be in every enclosed room)
RM: 308 D
RM: 308 C
RM: 308 B
RM: 308 A
NIPR Printer NIPR Laptop Tower Display Case Kitchen Height lower cabinets w/laminate countertop Credenza L-Shape Exec L-Shape Exec L-Shape Exec L-Shape Exec L-Shape Exec Circle table D-Shape mtg table Workstations Break table Workstations
NIPR Phone
NIPR
SIPR
Display Data Drop (opening for gov to install data lines) 3 duplex outlets Single duplex outlet Design can be changed if conflicts with lights/hvac/fire suppression All comm equipment and data lines will be government installed/furnished, on layout for assisting with design Fridge will be bought by government Rooms 308 A/B/C shall have executive style furniture Room 308 D will be workstations Outlets/data drops can be + or – 3ft
NIPR Printer
S
Ceiling tile layout Fire suppression is red Lights are yellow
S image1.png image2.png image3.png