Attachment 3- 3 TES RM 308 Floor Plan.pdf
PDF 220 KB Posted
- Attached to
- 3 TES Furniture Room 308
- Solicitation number
- FA255026Q0018
About this file
This document is a space planning layout and renovation specification for office suite 308. The project involves reconfiguring existing office space by removing a center wall and upper office to create a new open layout with four designated rooms (308A, 308B, 308C, and 308D). The proposed layout includes an executive suite with separate offices for SEL and CC functions, a front office CSS area, cubicle workstations, an award display area, and a snack/cabinet/refrigerator/coffee station. All interior walls must be constructed to achieve a Sound Transmission Class (STC) rating of approximately 40 or higher, and demountable walls with doors are specified at particular locations. Fire suppression systems are mandatory in every enclosed room. The current layout diagram shows the existing configuration with numbered work areas (01-09) and three primary rooms (308A, 308B, and 308C) that require modification. The proposed layout is noted as alterable and subject to estimate adjustments. The document provides floor dimensions of approximately 29'5" by 28'5" and includes detailed furniture placement for the reconfigured space.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 0610 3TES Furniture Questions and Answers.xlsx | XLSX spreadsheet | |
| Copy of Questions and Answers 3 TES Furniture.xlsx | XLSX spreadsheet | |
| FA255026Q00180001.pdf | ||
| 3TES room 308 Questions and Answers.xlsx | XLSX spreadsheet | |
| 3 TES RM 308 Floor Plan.pptx | PPTX presentation | |
| Attachment 2-3 TES Room 308 Salient Characteristics v2.pdf | ||
| Copy of Questions and Answers 3 TES Furniture.xlsx | XLSX spreadsheet | |
| Solicitation - FA255026Q0018.pdf | ||
| Attachment 4-Price Schedule.xlsx | XLSX spreadsheet | |
| Attachment 2-3 TES Room 308 Salient Characteristics.pdf | ||
| Attachment 1-3 TES Room 308 Furniture Statement of Work.pdf |
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Snack/Cabinets/Fridge/Coffee
(Exec) SEL Ofc
(exec) CC Ofc
(Front Office) CSS Ofc
Aw ard D isplay
Cubicle furniture
- Fire Suppression (must be in every enclosed room)
- All interior walls are to be built
(STC ~40+)
Proposed Layout: Can be altered/only estimates
RM: 308 D
RM: 308 C
RM: 308 B
RM: 308 A
• Solid black interior walls are intended to be demountable walls with doors shown as specific locations
Current Layout
- Center wall needs to be removed, and upper office needs to be removed
| Slide Number 1 |