SFS_Shoot_House_Bid_Schedule.pdf
PDF 101 KB Posted
- Attached to
- 50 SFS Indoor Shoot House
- Solicitation number
- FA2550-14-R-2007
About this file
Bid Schedule
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Wall_Illustration.docx | DOCX document | |
| Updated_Site_Visit_Q A.docx | DOCX document | |
| Shoothouse_directional_layout.pdf | ||
| Updated_Site_Visit_Q A.docx | DOCX document | |
| Site_Visit_Q A.pdf | ||
| Revised_Bid_Schedule.pdf | ||
| SOW_SFS_Shoothouse_03_Sep_14.pdf | ||
| SOW_SFS_Shoothouse_07_Aug_14.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
50 SFS Indoor Shoot House Bid Schedule
ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT
0001 1 Each HUFCOR FlexTract System or Equivalent
FFP
TThis will consist of an creating 45'x49'x8' interior room within an existing building with the capacity of maintaining a 40'x40'x8' room supporting a 40'x40' overhead grid tract system sectioned into 4'x4' blocks with 40 modular walls, 5 modular windows, and 10 modular doors capable of withstanding repeated
9mm/5.56mm simmunition round impacts. Refer to SOW dated 07 August 2014
FOB: Destination
PURCHASE REQUEST NUMBER: F3R3E04216A001
SIGNAL CODE: A
NET AMT
0002 1 Each OPTION Breach Door
FFP
Install breach door. Door must withstand a minimum of 1,500 breaches, measure
36” wide by 80” tall, be made of solid steel, be capable of breaching with pry or ram, and utilized reusable locking pins for breach operations. Refer to SOW dated
07 August 2014.
FOB: Destination
0003 1 Each OPTION Catwalk
FFP
Install a system of four interconnected catwalks; two running north to south and two running east to west. The contractor will install one set of stairs on the east end of the structure and another set of stairs on the north end of the structure to allow access to the catwalks. The contractor will ensure that the catwalk can support no less than 2000 lbs. The contractor will ensure that there are guard rails on all sides of the catwalk as well as both sides of the stairs. Refer to SOW dated
07 August
0004 1 Each OPTION Camera System
FFP
Install a camera system that will have the capability of coverage in hallways, entry points, and rooms. The contractor will ensure the camera system will be capable to play live footage as well as record footage for future use. The system will consist of 11 cameras with a minimum resolution of 720p, in color, with infrared capabilities, capable of recording, and being fixed mounted. The contractor will ensure that the installation of the camera system does not interfere with operation of the modular wall system. Refer to SOW dated 07 August 2014.
ATTACHMENTS
Refer to Attachment #1 Statement of Work dated 07 August 2014
INSPECTION AND ACCEPTANCE TERMS
Supplies/services will be inspected/accepted at:
CLIN INSPECT AT INSPECT BY ACCEPT AT ACCEPT BY
0001 Destination Government Destination Government
0002 Destination Government Destination Government
0003 Destination Government Destination Government
0004 Destination Government Destination Government
DELIVERY INFORMATION
CLIN DELIVERY DATE QUANTITY SHIP TO ADDRESS UIC
0001 120 dys. ADC 1 F3R3E0 50 SFS
101 FALCON PARKWAY
STE 17
SCHRIEVER AFB CO 80912
(719)567-5652
F3R3E0
0002 120 dys. ADC 1 (SAME AS PREVIOUS LOCATION)
0003 120 dys. ADC 1 (SAME AS PREVIOUS LOCATION)
0004 120 dys. ADC 1 (SAME AS PREVIOUS LOCATION)
File details come from the government source that posted it. Updated .