50 SFS Indoor Shoot House Bid Schedule

ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT

0001 1 Each HUFCOR FlexTract System or Equivalent

FFP

TThis will consist of an creating 45'x49'x8' interior room within an existing building with the capacity of maintaining a 40'x40'x8' room supporting a 40'x40' overhead grid tract system sectioned into 4'x4' blocks with 40 modular walls, 5 modular windows, and 10 modular doors capable of withstanding repeated

9mm/5.56mm simmunition round impacts. Refer to SOW dated 07 August 2014

FOB: Destination

PURCHASE REQUEST NUMBER: F3R3E04216A001

SIGNAL CODE: A

NET AMT

0002 1 Each OPTION Breach Door

FFP

Install breach door. Door must withstand a minimum of 1,500 breaches, measure

36” wide by 80” tall, be made of solid steel, be capable of breaching with pry or ram, and utilized reusable locking pins for breach operations. Refer to SOW dated

07 August 2014.

FOB: Destination

0003 1 Each OPTION Catwalk

FFP

Install a system of four interconnected catwalks; two running north to south and two running east to west. The contractor will install one set of stairs on the east end of the structure and another set of stairs on the north end of the structure to allow access to the catwalks. The contractor will ensure that the catwalk can support no less than 2000 lbs. The contractor will ensure that there are guard rails on all sides of the catwalk as well as both sides of the stairs. Refer to SOW dated

07 August

0004 1 Each OPTION Camera System

FFP

Install a camera system that will have the capability of coverage in hallways, entry points, and rooms. The contractor will ensure the camera system will be capable to play live footage as well as record footage for future use. The system will consist of 11 cameras with a minimum resolution of 720p, in color, with infrared capabilities, capable of recording, and being fixed mounted. The contractor will ensure that the installation of the camera system does not interfere with operation of the modular wall system. Refer to SOW dated 07 August 2014.

ATTACHMENTS

Refer to Attachment #1 Statement of Work dated 07 August 2014

INSPECTION AND ACCEPTANCE TERMS

Supplies/services will be inspected/accepted at:

CLIN INSPECT AT INSPECT BY ACCEPT AT ACCEPT BY

0001 Destination Government Destination Government

0002 Destination Government Destination Government

0003 Destination Government Destination Government

0004 Destination Government Destination Government

DELIVERY INFORMATION

CLIN DELIVERY DATE QUANTITY SHIP TO ADDRESS UIC

0001 120 dys. ADC 1 F3R3E0 50 SFS

101 FALCON PARKWAY

STE 17

SCHRIEVER AFB CO 80912

(719)567-5652

F3R3E0

0002 120 dys. ADC 1 (SAME AS PREVIOUS LOCATION)

0003 120 dys. ADC 1 (SAME AS PREVIOUS LOCATION)

0004 120 dys. ADC 1 (SAME AS PREVIOUS LOCATION)