PSFB Facitities List Active Card Reader 11 Feb 26.xlsx

XLSX spreadsheet 18 KB Posted

Attached to
Lenel S2 Renewal
Solicitation number
FA252126QB001
Issued by

About this file

This is a facilities list document detailing active card readers installed at Patrick Space Force Base (PSFB) as of February 11, 2026. The spreadsheet identifies 144 card reader access points distributed across multiple buildings (423, 425, 533, 750, 891, 981, and 350) and includes information on reader type (PIV Class or Multiclass), location, floor level, room assignments, and functional purpose. The readers support access control for various facility types including communications closets, office areas, server farms, lobbies, and exterior doors. Notable controlled areas requiring access restrictions include the Finance Vault, NIPR and SIPR Server Farm rooms, man traps, and classified office spaces. Many reader locations are designated for active shooter and FPCON C (Force Protection Condition) lockdown scenarios, indicating dual-use functionality for both routine access control and emergency response. The document identifies 54 total Multiclass readers distributed throughout the facilities.

This facilities list directly supports the Lenel S2 Renewal solicitation (FA252126QB001) issued by the Department of the Air Force Space Command. The solicitation seeks contractor maintenance and support services for Lenel S2 OnGuard Access Control Systems across three facilities at Patrick AFB and communications closet doors at both Patrick AFB and Cape Canaveral AFS. The contract includes a base year plus four option years, with required services encompassing 24-hour telephone support availability, scheduled maintenance, and emergency service call response by certified technicians. The facilities list serves as the technical reference documenting the specific card reader infrastructure requiring maintenance under this contract.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PSFB Online Card Readers

Patrick Space Force Base - Active Card Readers MultiClass
BLDG #Room #Reader CountFloor #
14231 - Piv Class ReaderController- 1st Floor South Communications Closet
21st Floor South Communications Closet Door
31st Floor SE Lobby Door Entry (Act. Shoot/ PFCON C Lockdown)
41st Floor SE Lobby Door Exit
51st Floor SW Lobby Door Entry (Act. Shoot/ PFCON C Lockdown)
61st Floor SW Lobby Door Exit
7425Exterior DoorsActive Shooter/ FPCON C Lockdowns- Both Lobbies
84231- Piv Class ReaderController- 1st Floor North East Communications Closet
91st Floor NE Communications Closet Door
101st Floor NW Communications Closet Door
111st Floor NE Lobby Door Entry (Act. Shoot/ PFCON C Lockdown)
121st Floor NE Lobby Door Exit
131st Floor NW Lobby Door Entry (Act. Shoot/ PFCON C Lockdown)
141st Floor NW Lobby Door Exit
15Finance Vault- CONTROLLED AREA
16Exterior DoorsActive Shooter/ FPCON C Lockdowns- Both Lobbies
174231- Multiclass ReaderController- 2nd Floor Center Communications Closet
182nd Floor Center Communications Closet
191st Floor CE Lobby Door Entry (Act. Shoot/ PFCON C Lockdown)
201st Floor CE Lobby Door Exit
211st Floor CW Lobby Door Entry (Act. Shoot/ PFCON C Lockdown/Single Point Entry)
221st Floor CW Lobby Door Exit
23425Exterior DoorsActive Shooter/ FPCON C Lockdowns- Both Lobbies
244231- Multiclass ReaderController- 2nd Floor South Communications Closet
252nd Floor South Communications Closet Door
264231- Multiclass ReaderController- 2nd Floor North Communications Closet
272nd Floor North Communications Closet Door
284231- Multiclass ReaderController-3rd Floor North Communications Closet
293rd Floor North Communications Closet Door
304231- Multiclass ReaderController- 3rd Floor South Communications Closet
313rd Floor South Communications Closet Door
323rd Floor SE SLD45 CC Section Offices Door- CONTROLLED AREA
333rd Floor SW SLD45 Cc Section Offices Door- CONTROLLED AREA
344251-1171- PIVClass ReaderController- B425 Room 1-17
35Rm 1-17 Sys. Admin Main Door
36Rm 1-17 Sys. Admin Back Door (Act. Shoot/ PFCON C Lockdown)
371st Floor NW Lobby Entrance (Act. Shoot/ PFCON C Lockdown/ Single Point Entry)
381st Floor NW Lobby Exit
39425Exterior DoorsActive Shooter/ FPCON C Lockdowns- Lobby
40425Room 1-491- Multiclass ReaderController- Rm. 1-49 Communications Closet
41Rm. 1-49 Communications Closet Door
421st Floor SW Lobby Entrance (Act. Shoot/ PFCON C Lockdown)
431st Floor SW Lobby Exit
44425Exterior DoorsActive Shooter/ FPCON C Lockdowns- Lobby
45425Room 1-581- Multiclass ReaderController- Rm. 1-80 1st Floor NE Communications Closet
46Rm. 1-80 Communications Closet Door
47NOTE- This Door is off-line1st Floor NE Lobby Entrance (Act. Shoot/ PFCON C Lockdown)
48due to key pad over riding1st Floor NE Lobby Exit
49425Exterior DoorsActive Shooter/ FPCON C Lockdowns- Lobby
50425Room 1-891- Multiclass ReaderController Room 1-89
51Room 1-89 CST Office Area
52425Room 2-151- Multiclass ReaderController- Room 2-15
53Room 2-15 MDT Lab
54Room 2-17 MDT Offices Area Door 1
55Room 2-17 MDT Offices Area Door 2
56Room 2-17 MDT Offices Area Door 3
57425Room 2-211- Multiclass Readercontroller- Second Floor NW Communications Closet Rm.2-21
58Second Floor NW Communications Closet Door
59425Room 2-21- Multiclass ReaderController- Second Floor SE Communications Closet Rm. 2-2
60Second Floor SE Communications Closet Door
611st floor 920th RQW CC Private Door (Acive shooter/ FPCON C Lockdown)
621st Floor SE Lobby Entrance (Acive shooter/ FPCON C Lockdown)
631st Floor SE Lobby Exit
64425Exterior DoorsActive Shooter/ FPCON C Lockdowns- Lobby, 920th CC Private Door
6553312910- Multiclass / 2- PIVClass ReadersControler- Room 129 (B533 East Half)
66East Hall South Entry (Act. Shoot/ PFCON C Lockdown/ Single Point Entry)
67East Hall South Exit
68East Hall North Entry (Active Shooter Lockdown)
69East Hall North Exit
70Room 103- Server Farm Area-East Door Entrance
71Room 103- Server Farm Area West Door Entrance (Acive shooter/ FPCON C Lockdown)
72Room 103 -Server Farm Area- West door Exit
73Room 104- Server Farm UPS Room- CONTROLLED AREA
74Room 105- NIPR Server Farm Room Entrance- CONTROLLED AREA
75Room 105- NIPR Server Farm Room Exit- CONTROLLED AREA
76Room 109- SIPR Server Farm Entrance- CONTROLLED AREA
77Room 113- Conference Room (Shelter In Place)
78Room 115- SCOO- Server Admin
79Room 116- QA
80Room 117- Communications Closet Door
81Room 121- SCOB Tele. Survey Front Office
82Room 121/129 Door- CONTROLLED AREA
83Room 125- SCOIT SIPR Office- CONTROLLED AREA
84Room 128- SCOIT/ SCOIA Area Man Trap South Door- CONTROLLED AREA
85Room 128- SCOIT/ SCOIA Area Man Trap North Door- CONTROLLED AREA
86Room 129- North East Door Entrance- CONTROLLED AREA (Acitive Shooter/ FPCON C Lock Downs)
87Room 129- North East Door Exit- CONTROLLED AREA
88Room 132- North Door- SCOIA UPS Room (Door Alarm Sensor Only)- CONTROLLED AREA
89Room 135- PT Testing, PA Storage Entrance- (Active Shooter Lockdown)
90Room 135- PT Testing, PA Storage Exit
91Room 136- SCOIB Office Area Entrance (Active Shooter Lockdown)
92Room 136- SCOIB Office Area Exit
93533Exterior DoorsExterior Doors Active Shooter/ FPCON Lockdowns
94533145A16- Multiclass ReadersController- Room 145A (533 West Half)
95West Hall- South Door Entrance (Acitive Shooter/ FPCON C Lock Downs)
96West Hall- South Door Exit
97West Hall- South Door Entrance (Acitive Shooter Lockdown)
98West Hall- South Door Exit
99Room 136D- SCOIB Office Area North Door Entrance (Active Shooter Lockdown)
100Room 136D- SCOIB Office Area North Door Exit
101Room 136D- SCOIB Office Area South Door Entrance (Active Shooter, FPCON C Lockdowns)
102Room 136D- SCOIB Office Area South Door Exit
103Room 147- 45th SCS Booster Club Storage Room
104Room 145- Microwave Wide Band Hallway Entrance- CONTROLLED AREA
105Room 145- Microwave Wide Band Hallway Exit- CONTROLLED AREA
106Room 145- West Door Entrance- CONTROLLED AREA (Active Shooter, FPCON C Lockdowns)
107Room 145- West Door Exit
108Room 145A- East Door (Door Alarm Sensor Only)- CONTROLLED AREA
109Room 146- 45th SCS Material Control Office Area
110Room 149- EWOKS Network Engineers
111Room 150- Hallway Entrance
112Room 150/153B Door
113Room 153A- EWOKS CFP Entrance- (Active Shooter Lockdown)
114Room 153A/ 153 Entrance Door
115Room 153/153A Exit Door
116Room 160- EWOKS Main Office AreaHallway Door Entrance- (Active Shooter Lockdown)
117Room 160- EWOKS Main Office Area Hallway Door Exit
118Room 160A- EWOKS Admin. Office door
119Room 160D- EWOKS Network Defence Offcie Door
120Room 162- EWOKS Network Office Door Entrance (Active Shooter Lockdown)
121Room 162- EWOKS Network Office Door Exit
122Room 164- SCOIB Storage Garage (Active Shooter Lockdown)
123533Exterior DoorsExterior Doors Active Shooter/ FPCON Lockdowns
1247501151- Multiclass ReaderController- Room 115
125Room 115 Communications Closet Door
1267501061- Multiclass ReaderController Room 106
127Room 106 Communications Closet Door
1287501611- Multiclass ReaderController- Room 161
129Room 161 Comunications Closet Door
1307502511- Multiclass ReaderController- Room 251
131Room 251 Communications Closet Door
132891Comm Hut3- Multiclass ReadersController- B891 Main Room
133Gate- Entrance- NOTE- Gate very damaged due to GOV wrecking into it
134South Door- Entrance- CONTROLLED AREA
135North Door Entrance- CONTROLLED AREA
136981341- Multiclass ReaderController- Room 34
137Room 34 Main Entrance
138Room 34 Main Emergency Exit
1399811191- Multiclass ReaderController- room 119
140Room 119- Communications Closet Door
1419811231- Multiclass ReaderController- Room 123
142Room 123- Communications Closet Door
143350Comm Room1-Multiclass ReaderController- Communication Closet (Loading Dock)
144Communication Closet (Loading Dock) Door
Total MultiClass Readers : 54

File details come from the government source that posted it. Updated .