Attachment 2 - Technical Specs - Patrick Space Force Base .pdf
PDF 31 MB Posted
- Attached to
- Simplified Acquisition Base Engineering Requirements (SABER) Federal contract opportunity
- Solicitation number
- FA252124R0008
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Solicitation Amendment - FA252124R00080001.pdf | ||
| Attachment 7 - Questions and Answers.pdf | ||
| Solicitation Amendment FA252124R00080001 SF 30.pdf | ||
| Attachment 9 - Section L Addendum Rev 1.pdf | ||
| Attachment 5 - Past Performance Questionnaire Final.pdf | ||
| Attachment 9 - Section L Addendum.pdf | ||
| Attachment 10 - Section M Addendum.pdf | ||
| Attachment 6 - Sample_Consent Form.docx | DOCX document | |
| Attachment 3 - Wage Determination FL20240001-02Feb2024.pdf | ||
| Attachment 7 - Question_and_Answer_Template.docx | DOCX document | |
| Attachment 8 - Fact Sheet.pdf | ||
| Attachment 1 - SABER 2023 SOW July 23.pdf | ||
| Attachment 4 - Price Schedule .xlsx | XLSX spreadsheet | |
| Solicitation - FA252124R0008.pdf |
Show all 14
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Job Order Contract Technical Specifications Book 1 of 5 CSI Divisions 01 - 06 January 2022
Patrick Space Force Base
FA252124R0008
Attachment 2
This Page Intentionally Left Blank
Table of Contents
January 2022
Patrick Space Force Base TOC - 1
01 General Requirements
01 20 00 00 General Requirements and Conditions 01 20 00 00a Summary of Work 01 22 16 00 No Specification Required 01 41 26 00 Sources for Reference Publications 01 52 13 00 Temporary Facilities and Controls 01 54 23 00 Scaffolding Tubular Steel 01 54 23 00a Unit Masonry Assemblies 01 56 26 00 Sediment Removal 01 56 26 00a Erosion Control 01 56 39 00 Temporary Pest Control 01 58 00 00 Environmental Protection 01 58 00 00a Temporary Storm Water Pollution Control 01 58 13 00 Signage 01 66 19 00 Recycled / Recovered Materials 01 71 23 16 Cutting and Patching 01 74 19 00 Integrated Solid Waste Management 01 74 19 00a Closeout Procedures 01 74 19 00b Construction Waste Management
02 Existing Conditions
02 32 13 00 Subsurface Drilling, Sampling, And Testing 02 41 13 13 Selective Demolition 02 41 13 13a Portland Cement Concrete Removal 02 41 16 13 Building Demolition 02 61 00 00 Excavation And Handling Of Contaminated Material 02 61 13 00 Underground Storage Tank Removal 02 61 13 00a Precision Testing Of Underground Fuel Oil Tanks 02 61 13 00b Hydrostatic Pressure Testing Of Air Receiving Tanks 02 61 26 00 Disposal Of Hazardous Materials 02 61 26 00a Removal Of Friable Asbestos-Containing Materials 02 82 13 00 General Provisions (Asbestos Abatement Projects) 02 82 16 00 Encapsulation (Lock-Down) Of Asbestos-Containing Materials 02 82 33 00 Temporary Pressure Differential Systems 02 82 33 00a Respiratory Protection 02 82 33 00b Decontamination Units 02 82 33 00c Removal Of Nonfriable Asbestos-Containing Materials 02 83 19 13 Removal And Disposal Of Lead-Containing Paint 02 83 19 13a Lead Paint Related Abatement Procedures 02 83 19 13b XRF Testing For Lead-Based Paint 02 83 19 13c Lead Dust Wipe, Air And Tclp Sampling And Analysis 02 84 16 00 Removal of Fluorescent Light Ballasts/Capacitors and Fluorescent Light Tubes 02 84 16 00a Interior Lighting 02 84 16 00b Exterior Lighting 02 87 13 33 Mold Remediation 02 87 16 13 Bird And Bird Waste Abatement
03 Concrete
03 01 30 71 Concrete Rehabilitation 03 05 13 00 Cast-In-Place Concrete 03 11 16 13 Rusticated Concrete Finishes 03 11 16 13a Cast-In-Place Architectural Concrete 03 31 13 00 Cement Concrete Pavement 03 31 13 00a Roller Compacted Concrete Pavement 03 31 13 00b Portland Cement Concrete Overlays 03 31 13 00c Steel Reinforced Portland Cement Concrete Overlays 03 31 13 00d Fiber Reinforced Portland Cement Concrete Overlays 03 35 23 00 Exposed Aggregate Surface Concrete Walls 03 37 13 00 Shotcrete 03 37 13 00a Glass Fiber Reinforced Concrete
TOC - 2 Patrick Space Force Base
03 41 16 00 Plant-Precast Structural Concrete 03 41 16 00a Precast Lighweight Roof Slabs 03 41 23 00 Architectural Precast Concrete 03 41 26 00 Unbonded Post-Tensioned Concrete 03 51 13 00 Cementitious Wood-Fiber Deck 03 51 16 00 Gypsum Plank Decking 03 51 16 00a Gypsum Concrete Decks 03 53 14 00 Concrete Floor Topping 03 54 16 00 Cement-Based Underlayment
04 Masonry
04 01 20 51 Clay Masonry Restoration And Cleaning 04 01 40 51 Stone Restoration And Cleaning 04 05 23 16 Sheet Metal Flashing And Trim 04 23 13 00 Glass Unit Masonry Assemblies 04 41 00 00 Dimension Stone Cladding 04 41 00 00a Stone Masonry 04 41 00 00b Interior Stone Facing
05 Metals
05 05 21 00 Structural Steel 05 12 23 00 Cold-Formed Metal Framing 05 14 13 00 Structural Aluminum 05 15 16 00 Ornamental Metal 05 21 19 00 Steel Joists 05 31 13 00 Steel Deck 05 50 00 00 Metal Fabrications 05 51 13 00 Metal Stairs 05 51 13 00a Fabricated Spiral Stairs 05 52 13 00 Pipe And Tube Railings 05 53 13 00 Gratings 05 58 16 00 Ornamental Formed Metal 05 73 23 00 Miscellaneous Ornamental Metals 05 73 23 00a Ornamental Railings
06 Wood, Plastics, and Composites
06 01 20 91 Wood Restoration 06 05 23 00 Timber Bridge Components 06 05 23 00a Miscellaneous Carpentry 06 05 23 00b Heavy Timber Construction 06 05 73 33 Wood Decking 06 10 00 00 Rough Carpentry 06 11 13 00 Rough Carpentry Renovation 06 15 13 00 Exterior Rough Carpentry 06 16 23 00 Sheathing 06 17 13 00 Structural Glued-Laminated Timber 06 17 33 00 Metal-Plate-Connected Wood Trusses 06 22 13 00 Exterior Finish Carpentry 06 22 13 00a Interior Finish Carpentry 06 25 16 00 Paneling 06 41 13 00 Interior Architectural Woodwork 06 41 13 00a WOOD-VENEER-FACED ARCHITECTURAL CABINETS 06 41 93 00 Door Hardware 06 42 19 00 Plastic Paneling 06 46 29 00 Exterior Architectural Woodwork 06 51 13 00 Plastic Lumber 06 51 13 00a Composite Plastic Lumber
Patrick Space Force Base TOC - 3
06 51 13 00b Structural Plastic Lumber 06 74 13 00 Pultruded Fiberglass Industrial Grating 06 82 00 00 Pultruded Fiberglass Structural Shapes
07 Thermal And Moisture Protection
07 01 50 81 Built-Up Coal-Tar Roofing 07 01 50 81a Membrane Reroofing Preparation 07 05 13 00 CSPE Membrane Roofing 07 05 13 00a APP-Modified Bituminous Membrane Roofing 07 05 13 00b SBS-Modified Bituminous Membrane Roofing 07 11 13 00 Bituminous Dampproofing 07 13 13 00 Bituminous Waterproofing 07 13 53 00 Self-Adhering Sheet Waterproofing 07 13 53 00a Elastomeric Sheet Waterproofing 07 14 13 00 Hot Fluid-Applied Rubberized Asphalt Waterproofing 07 14 16 00 Cold Fluid-Applied Waterproofing 07 16 13 00 Modified Cement Waterproofing 07 16 16 00 Crystalline Waterproofing 07 16 19 00 Metal-Oxide Waterproofing 07 17 13 00 Bentonite Waterproofing 07 19 13 00 Water Repellents 07 21 13 13 Stretched-Fabric Wall Systems 07 21 16 00 Building Insulation 07 24 13 00 Polymer-Based Exterior Insulation And Finish System (EIFS) 07 24 13 00a Water-Drainage Exterior Insulation and Finish System (EIFS) 07 31 13 13 Asphalt Shingles 07 31 16 00 Metal Shingles 07 31 33 00 Composite Rubber Shingles 07 32 13 00 Clay Roof Tiles 07 32 16 00 Concrete Roof Tiles 07 34 00 00 Slate Shingles 07 34 00 00a Wood Shingles And Shakes 07 41 13 00 Metal Roof Panels 07 41 13 00a Sheet Metal Roofing 07 42 13 19 Glazing 07 42 93 00 Siding 07 46 16 00 Metal Wall Panels 07 46 16 00a Metal Plate Wall Panels 07 46 63 00 Insulated-Core Metal Wall Panels 07 51 13 00 Built-Up Asphalt Roofing 07 53 16 00 EPDM Membrane Roofing 07 54 19 00 Polyvinyl-Chloride (PVC) Roofing 07 54 23 00 Thermoplastic Polyolefin (TPO) Roofing 07 56 00 00 Coated Foamed Roofing 07 56 00 00a Fabric-Wrapped Panels 07 63 00 00 Common Work Results for Fire Suppression 07 63 00 00a Common Work Results for Plumbing 07 63 00 00b Common Work Results for HVAC 07 71 23 00 Manufactured Roof Specialties 07 72 13 00 Packaged, Outdoor, Central-Station Air-Handling Units 07 72 13 00a Intake and Relief Ventilators 07 72 23 00 Roof Accessories 07 81 16 00 Sprayed Fire-Resistive Materials 07 84 13 16 Through-Penetration Firestop Systems 07 84 13 16a Fire-Resistive Joint Systems 07 84 13 16b Firestopping 07 84 56 13 Board Fire Protection 07 91 23 00 Joint Sealants 07 95 13 13 Architectural Joint Systems 07 95 13 16 Roof Expansion Assemblies
08 Openings
08 01 52 61 Wood Windows
TOC - 4 Patrick Space Force Base
08 05 13 00 Steel Doors And Frames 08 05 13 00a Steel Entry Doors 08 05 13 00b Stainless Steel Doors And Frames 08 05 13 00c Wood Doors 08 05 13 00d Flush Wood Doors 08 11 63 13 Steel Storm Doors 08 11 63 13a Security Window Screens and Doors 08 11 63 23 Aluminum Storm Doors 08 11 73 00 Sliding Metal Fire Doors 08 14 16 00 Stile And Rail Wood Doors 08 16 13 00 Fiberglass Reinforced Plastic (FRP) Doors and Frames 08 18 16 00 Sliding Aluminum-Framed Glass Doors 08 18 16 00a Sliding Wood-Framed Glass Doors 08 31 13 00 Access Doors And Frames 08 33 16 00 Overhead Coiling Grilles 08 33 23 11 Overhead Coiling Doors 08 33 36 00 Side Coiling Grilles 08 34 49 13 Radiation Protection 08 34 53 00 Detention Doors And Frames 08 34 53 00a Security Grilles 08 34 73 16 Sound Control Doors 08 35 13 13 Folding Doors 08 36 13 00 Sectional Overhead Doors 08 38 13 00 Flexible Doors 08 42 13 00 Aluminum-Framed Entrances And Storefronts 08 42 26 00 All-Glass Entrances And Storefronts 08 42 29 23 ICU/CCU Entrance Doors 08 44 13 00 Glazed Aluminum Curtain Walls 08 44 13 00a Structural-Sealant-Glazed Curtain Walls 08 44 13 00b Sloped Glazing Assemblies 08 45 23 00 Unit Skylights 08 45 23 00a Metal-Framed Skylights 08 45 23 00b Structured-Polycarbonate-Panel Assemblies 08 45 23 00c Fiberglass-Sandwich-Panel Assemblies 08 51 13 00 Aluminum Windows 08 51 13 00a Aluminum Replacement Windows 08 51 23 00 Steel Windows 08 51 69 00 Aluminum Storm Windows 08 53 13 00 Vinyl Windows 08 56 19 00 Security Windows 08 56 83 00 Roof Windows 08 71 11 00 Detention Door Hardware 08 75 13 00 Automatic Door Operators 08 83 13 00 Mirrors 08 84 00 00 Plastic Glazing 08 87 23 16 Fragment Retention Film For Glass 08 88 53 00 Security Glazing 08 90 00 00 Louvers And Vents
09 Finishes
09 01 30 91 Ceramic Tile 09 01 60 91 Carpet 09 22 13 13 Gypsum Plaster 09 22 13 13a Gypsum Veneer Plaster 09 22 13 13b Portland Cement Plaster 09 22 16 13 Non-Load-Bearing Steel Framing 09 22 36 23 Lath and Plaster Renovation 09 23 13 00 Gypsum Board Renovation 09 28 13 00 Gypsum Board 09 28 13 00a Gypsum Board Shaft-Wall Assemblies 09 51 13 00 Acoustical Panel Ceilings 09 51 23 00 Acoustical Tile Ceilings 09 63 13 00 Brick Flooring 09 64 13 00 Wood Flooring 09 64 23 00 Wood Sports-Floor Assemblies
Patrick Space Force Base TOC - 5
09 65 13 13 Cork Flooring 09 65 13 13a Resilient Wall Base And Accessories 09 65 13 33 Resilient Floor Tile 09 65 13 33a Resilient Sheet Flooring 09 65 13 33b Linoleum Floor Coverings 09 65 19 23 Material and Design Standards 09 65 66 00 Fluid-Applied Athletic Flooring 09 65 66 00a Resilient Sports-Floor Coverings 09 66 13 00 Portland Cement Terrazzo Flooring 09 66 23 00 Resinous Matrix Terrazzo Flooring 09 67 16 00 Resinous Flooring 09 68 13 00 Carpet Tile 09 69 13 00 Access Flooring 09 69 33 00 Cable Management System 09 72 16 13 Wall Coverings 09 84 13 00 Acoustical Wall Panels 09 91 13 00 Exterior Painting 09 91 13 00a Wood Stains and Transparent Finishes 09 91 13 00b High-Temperature-Resistant Coatings 09 91 23 00 Interior Painting 09 91 23 00a Multicolored Interior Coatings 09 93 23 13 Floor Treatment Refinishing Wood Floors 09 96 00 00 High-Performance Coatings
10 Specialties
10 01 50 11 Metal Lockers 10 11 13 13 Visual Display Surfaces 10 14 23 11 Vitrified Brick Pavement Replacement 10 14 53 11 Traffic Signs 10 17 16 13 Telephone Specialties 10 21 13 13 Toilet Compartments 10 21 13 19 Solid Surface Material Toilet Compartments 10 21 16 17 Cubicle Curtains and Tracks 10 22 13 00 Wire Mesh Partitions 10 22 19 13 Demountable Partitions 10 22 43 00 Operable Panel Partitions 10 26 13 00 Impact-Resistant Wall Protection 10 28 13 13 Toilet And Bath Accessories 10 28 13 13a Detention Toilet Accessories 10 28 16 13 Bath Accessories 10 28 19 16 Plumbing Fixtures 10 44 13 00 Fire Protection Cabinets 10 44 16 13 Fire Extinguishers 10 51 26 00 Solid Plastic Lockers 10 55 23 23 Postal Specialties 10 56 13 16 Metal Storage Shelving 10 71 13 13 Exterior Shutters 10 71 13 13a Hurricane Shutters 10 73 13 13 Awnings 10 75 16 00 Flagpoles 10 81 13 00 Oriented Flexible Netting Bird Barrier 10 86 00 00 Detention Furniture
11 Equipment
11 12 16 00 Parking Control Equipment 11 12 16 00a Prefabricated Control Booths 11 13 13 00 Loading Dock Equipment 11 14 13 16 Turnstiles 11 21 63 00 Food Service Equipment 11 30 13 13 Residential Appliances 11 30 13 13a Refrigerators 11 30 13 13b Gas Ranges 11 30 13 13c Electric Ranges
TOC - 6 Patrick Space Force Base
11 30 13 13d Range Hoods 11 32 13 00 Unit Kitchens 11 41 33 00 Residential Casework 11 52 13 13 Projection Screens 11 66 13 00 Playground Equipment And Structures 11 66 13 00a Recreational Facilities 11 66 13 00b Gymnasium Equipment 11 66 53 11 Gymnasium Dividers 11 68 23 13 Playing Fields 11 82 19 00 Packaged Incinerators 11 82 26 00 Waste Compactors 11 98 12 00 Detention Enclosures
12 Furnishings
12 01 60 00 Fixed Audience Seating 12 21 13 13 Horizontal Louver Blinds 12 21 13 13a Vertical Louver Blinds 12 22 13 00 Draperies and Tracks 12 24 13 00 Roller Shades 12 24 13 00a Pleated Shades 12 31 16 00 Stone Countertops 12 31 16 00a Kitchen Casework, Stainless Steel Cabinets 12 36 61 16 Solid Polymer Fabrications 12 48 13 13 Floor Mats And Frames 12 48 13 13a Foot Grilles 12 62 23 00 Portable Bleachers 12 66 00 00 Telescoping Stands
13 Special Construction
13 34 16 13 Fixed Wood Bleachers (Exterior) 13 34 16 13a Demountable Bleachers (Exterior) 13 34 16 13b Grandstands And Bleachers 13 34 19 00 Metal Building Systems 13 42 63 16 Security Ceiling Systems 13 47 13 13 Cathodic Protection
14 Conveying Equipment
14 01 30 71 Electric Traction Elevators 14 01 30 71a Hydraulic Elevators 14 11 00 00 Dumbwaiters 14 31 00 00 Escalators 14 41 16 00 Personnel Lifts 14 42 13 00 Wheelchair Lifts 14 91 33 00 Chutes
21 Fire Suppression
21 05 13 00 Common Motor Requirements for Fire Suppression Equipment 21 05 19 00 Water Distribution 21 05 29 00 Heat Tracing for Fire-Suppression Piping 21 05 48 13 Vibration And Seismic Controls For Fire-Suppression Piping And Equipment 21 07 00 00 Fire-Suppression Systems Insulation 21 11 19 00 Fire-Suppression Standpipes 21 13 00 00 Fire Suppression Sprinkler Systems
Patrick Space Force Base TOC - 7
21 13 13 00 Wet-Pipe Fire-Suppression Sprinklers 21 13 16 00 Dry-Pipe Fire-Suppression Sprinklers 21 13 19 00 Preaction Sprinkler Systems 21 13 26 00 Deluge Fire Suppression Sprinkler Systems 21 13 39 00 Foam Fire Extinguishing 21 22 16 00 Clean-Agent Extinguishing Systems 21 24 00 00 Dry-Chemical Fire-Extinguishing Systems 21 30 00 00 Fire Pumps 21 31 13 00 Electric-Drive, Centrifugal Fire Pumps 21 31 13 00a Pressure-Maintenance Pumps 21 31 13 00b Controllers for Fire-Pump Drivers 21 31 16 00 Diesel-Drive, Centrifugal Fire Pumps
22 Plumbing
22 01 40 81 Emergency Plumbing Fixtures 22 05 13 00 Common Motor Requirements for Plumbing Equipment 22 05 19 00 Meters and Gages for Plumbing Piping 22 05 48 13 Vibration And Seismic Controls For Plumbing Piping And Equipment 22 05 53 00 Identification for Plumbing Piping and Equipment 22 05 76 00 Sanitary Sewerage 22 05 76 00a Storm Drainage Piping Specialties 22 07 19 00 Plumbing Insulation 22 07 19 00a Piping Insulation 22 11 16 00 Piped Utilities Basic Materials And Methods 22 11 16 00a Domestic Water Piping 22 11 16 00b Sanitary Waste And Vent Piping 22 11 16 00c Storm Drainage Piping 22 11 16 00d Hydronic Piping 22 11 16 00e Steam And Condensate Piping 22 11 16 00f Refrigerant Piping 22 11 16 00g General-Service Compressed-Air Piping 22 11 16 00h Compressed-Air Piping For Laboratory And Healthcare Facilities 22 11 16 00i Vacuum Piping For Laboratory And Healthcare Facilities 22 11 16 00j Gas Piping For Laboratory And Healthcare Facilities 22 11 19 00 Electronic Air Cleaners 22 11 23 13 Water Distribution Pumps 22 11 23 13a Packaged Booster Pumps 22 11 23 23 Water Supply Wells 22 11 23 23a Hydronic Pumps 22 12 23 13 Electric, Domestic Water Heaters 22 12 23 13a Fuel-Fired, Domestic Water Heaters 22 12 23 26 Underground Storage Tanks 22 13 19 13 High-Efficiency Particulate Filtration 22 13 19 26 Interceptors 22 13 19 33 General-Duty Valves for Plumbing Piping 22 13 19 33a General-Duty Valves for HVAC Piping 22 13 29 13 Packaged Sewage Pumping Stations 22 13 29 13a Lift Station 22 13 29 13b Sewage Pumps 22 14 29 13 Sump Pumps 22 15 13 00 General-Service Packaged Air Compressors and Receivers 22 31 16 00 Water Softeners 22 34 36 23 Water-Tube Boilers 22 35 23 13 Domestic Water Heat Exchangers 22 42 19 00 Porcelain Steel Bathtub Liners and Surrounds 22 43 00 00 Medical Plumbing Fixtures 22 46 13 13 Security Plumbing Fixtures 22 47 13 00 Drinking Fountains And Water Coolers 22 66 83 16 Chemical-Waste Systems for Laboratory and Healthcare Facilities
23 Heating, Ventilating, and Air-Conditioning (HVAC)
23 01 10 91 Sequence Of Operation 23 01 10 91a Testing, Adjusting, And Balancing
TOC - 8 Patrick Space Force Base
23 01 30 51 Air Duct Cleaning 23 01 50 61 Cast-Iron Boilers 23 01 60 71 Condensing Units 23 05 13 00 Common Motor Requirements for HVAC Equipment 23 05 16 00 Expansion Fittings and Loops for Plumbing Piping 23 05 16 00a Expansion Fittings and Loops for HVAC Piping 23 05 19 00 Meters and Gages for HVAC Piping 23 05 29 00 Steam Distribution 23 05 29 00a Hangers and Supports for Plumbing Piping and Equipment 23 05 29 00b Hangers and Supports for HVAC Piping and Equipment 23 05 48 13 Vibration And Seismic Controls For HVAC Piping And Equipment 23 05 53 00 Identification for HVAC Piping and Equipment 23 07 13 00 HVAC Insulation 23 07 13 00a Equipment Insulation 23 07 13 00b Duct Insulation 23 09 00 00 HVAC Instrumentation And Controls 23 09 23 53 Enclosed Controllers 23 11 23 00 Relief Wells 23 11 23 00a Monitoring Wells 23 11 23 00b Facility Natural-Gas Piping 23 11 23 00c Facility Liquefied-Petroleum Gas Piping 23 13 23 16 Facility Fuel-Oil Piping 23 21 13 23 Radiant Heating Piping 23 21 23 23 Electric-Drive, Vertical-Turbine Fire Pumps 23 21 23 23a Diesel-Drive, Vertical-Turbine Fire Pumps 23 22 23 13 Steam Condensate Pumps 23 25 13 00 HVAC Water Treatment 23 31 13 13 Metal Ducts 23 31 13 13a HVAC Casings 23 31 13 16 Tailpipe Exhaust Equipment 23 31 13 19 Duct Accessories 23 31 16 13 Nonmetal Ducts 23 33 13 13 Draft Control Devices 23 34 13 00 Axial Fans 23 34 16 00 Centrifugal Fans 23 34 16 00a Power Ventilators 23 34 33 00 Air Curtains 23 36 13 00 Diffusers, Registers, And Grilles 23 41 13 00 Air Filters 23 42 13 00 Gas-Phase Air Filtration 23 51 13 13 Breechings, Chimneys, And Stacks 23 52 13 00 Electric Boilers 23 52 16 13 Condensing Boilers 23 52 36 00 Fire-Tube Boilers 23 53 16 00 Feedwater Equipment 23 53 16 00a Deaerators 23 54 19 00 Furnaces 23 55 23 13 Radiant Heating and Cooling Units 23 55 23 13a Radiant-Heating Electric Panels 23 55 33 13 Unit Heaters 23 55 33 16 Fuel-Fired Unit Heaters 23 57 13 00 Heat Exchangers 23 61 16 00 Centrifugal Water Chillers 23 61 16 00a Rotary-Screw Water Chillers 23 62 13 00 Indirect-Fired Absorption Water Chillers 23 63 13 00 Air-Cooled Condensers 23 63 13 00a Split-System Air-Conditioning Units 23 64 13 16 Direct-Fired Absorption Water Chillers 23 64 16 16 Fan-Coil Units 23 64 23 13 Scroll Water Chillers 23 64 23 16 Reciprocating Water Chillers 23 65 13 16 Cooling Towers 23 72 13 00 Air-To-Air Energy Recovery Units 23 73 13 00 Modular Indoor Central-Station Air-Handling Units 23 74 16 13 Rooftop Replacement Air Units 23 74 16 13a Self-Contained Air-Conditioners 23 74 16 13b Unit Ventilators 23 74 23 13 Direct-Fired, Makeup Air Units 23 74 23 13a Indirect-Fired, Packaged H&V Units 23 81 13 11 Packaged Terminal Air Conditioners
Patrick Space Force Base TOC - 9
23 81 23 12 Computer-Room Air-Conditioners 23 82 16 11 Air Coils 23 82 33 00 Convection Heating Units 23 83 13 00 Radiant-Heating Electric Cables 23 83 13 13 Heat Tracing for Plumbing Piping 23 83 13 13a Heat Tracing for HVAC Piping 23 84 13 16 Humidifiers 23 84 16 33 Dehumidification Units
26 Electrical
26 01 20 91 Electrical Renovation 26 05 00 00 Common Work Results for Electrical 26 05 13 16 Conductors And Cables 26 05 13 16a Undercarpet Cables 26 05 13 16b Medium-Voltage Cables 26 05 19 13 Raceways And Boxes 26 05 19 13a Underfloor Raceways For Electrical Systems 26 05 19 16 Common Work Results for Communications 26 05 19 16a Common Work Results for Electronic Safety and Security 26 05 19 16b Control-Voltage Electrical Power Cables 26 05 19 16c Communications Equipment Room Fittings 26 05 19 16d Communications Backbone Cabling 26 05 19 16e Communications Horizontal Cabling 26 05 19 16f Conductors and Cables for Electronic Safety and Security 26 05 26 00 Lightning Protection 26 05 26 00a Grounding And Bonding 26 05 26 00b Overhead Electrical Distribution 26 05 29 00 Hangers And Supports For Electrical Systems 26 05 29 00a Vibration And Seismic Controls For Electrical Systems 26 05 33 16 Wiring Devices 26 05 36 00 Cable Trays 26 05 53 00 Electrical Identification 26 05 53 00a Intercommunications and Program Systems 26 09 23 00 Lighting Controls 26 09 23 00a Lighting Control Devices 26 09 23 00b Electrical Power Monitoring And Control 26 09 23 00c Motor-Control Centers 26 09 23 00d Central Dimming Controls 26 09 23 00e Modular Dimming Controls 26 11 13 00 Secondary Unit Substations 26 11 16 11 Switchgear 26 12 13 00 Medium-Voltage Transformers 26 12 13 00a Low-Voltage Transformers 26 24 13 00 Electricity Metering 26 24 13 00a Enclosed Switches And Circuit Breakers 26 24 13 00b Switchboards 26 24 16 00 Panelboards 26 24 19 00 Power Distribution Units 26 25 13 00 Enclosed Bus Assemblies 26 28 13 00 Fuses 26 31 00 00 Photovoltaic Energy Equipment 26 32 13 13 Packaged Engine Generators 26 33 43 00 Central Battery Inverters 26 33 43 00a Nurse Call 26 33 43 00b Public Address and Mass Notification Systems 26 33 53 00 Static Uninterruptible Power Supply 26 33 53 00a Variable Frequency Controllers 26 35 33 16 Power Factor Correction Capacitors 26 36 13 00 Transfer Switches 26 55 61 00 Stage Lighting
27 Communications
27 11 19 00 Loose-Tube Gel-Filled Fiber Optic Cables
TOC - 10 Patrick Space Force Base
27 51 43 00 Educational Intercommunications and Program Systems 27 53 13 13 Clock And Program Control
28 Electronic Safety and Security
28 16 11 00 Perimeter Security 28 16 11 00a Intrusion Detection 28 16 11 00b Security Access 28 21 31 00 Video Surveillance 28 46 00 00 Fire Detection and Alarm 28 46 00 00a Fire Detection and Alarm (Proprietary) 28 46 00 00b Fire Detection and Alarm Interfaces 28 46 21 17 Digital, Addressable Fire-Alarm System 28 46 21 17a Zoned (DC Loop) Fire-Alarm System
31 Earthwork
31 05 13 00 Earthwork 31 05 13 00a Subdrainage 31 11 00 00 Site Clearing 31 13 13 00 Tree Protection And Trimming 31 23 16 13 Excavation Support And Protection 31 23 19 00 Dewatering 31 24 13 00 Embankment 31 24 13 00a Levee Closure 31 25 14 13 Geosynthetic Fabric 31 25 14 23 Unit Pavers 31 25 14 26 Silt Fences 31 31 19 13 Soil Sterilization 31 32 13 16 Soil Stabilization-Lime 31 32 19 16 Sewage Treatment Lagoons 31 32 19 16a Pond Reservoir Liners 31 36 13 00 Wire Mesh Gabions 31 37 13 00 Riprap 31 41 13 00 Drilled Piers 31 45 13 00 Soil Stabilization-Vibroflotation 31 62 16 16 Steel H Piles 31 62 23 13 Concrete-Filled Steel Piles
32 Exterior Improvements
32 01 11 53 Asphalt Paving 32 01 11 53a Traffic Coatings 32 01 13 61 Crack Sealing Of Bituminous Pavements 32 01 13 61a Spray Applications, Seal Coats, And Surface Treatments 32 01 16 71 Cold Mix Recycling 32 11 16 16 Crushed Stone Paving 32 11 16 16a Crushed Stone 32 11 16 16b Select Gravel 32 12 13 13 Bituminous Paving-Repair And Resurfacing 32 12 13 13a Asphaltic Concrete Overlays 32 13 13 33 Decorative Cement Concrete Pavement 32 14 09 00 Exterior Plants 32 14 11 00 Asphalt Concrete Sidewalks 32 14 11 00a Miscellaneous Sidewalks 32 14 11 00b Precast Sidewalks And Pavers 32 14 33 13 Porous Unit Paving 32 16 13 13 Steel Curbs 32 17 23 13 Track, Court, And Playground Markings 32 17 26 00 Tactile/Detectable Warning Tile
Patrick Space Force Base TOC - 11
32 18 23 29 Colored Athletic Wearing Surface 32 18 23 29a Synthetic Turf 32 18 23 33 Synthetic Running Track Surface 32 31 13 13 Chain-Link Fences And Gates 32 31 13 53 High-Security Chain-Link Fences And Gates 32 31 19 00 Ornamental Metal Fences and Gates 32 31 29 00 Permanent Wood Fencing 32 32 13 00 Segmental Retaining Walls 32 33 23 00 Site Furnishings 32 33 23 00a Miscellaneous Site and Street Furnishings 32 84 13 00 Irrigation Systems 32 91 13 16 Tree Relocation 32 91 13 33 Lawns And Grasses 32 91 19 13 Concrete Revetment 32 91 19 13a Septic Tank Systems
33 Utilities
33 01 10 58 Repair And Maintenance Of Imhoff Tanks 33 01 10 58a Sewer Line Cleaning 33 01 10 71 Pipe Lining 33 01 30 42 Repair And Maintenance Of Siphon Tank And Siphons 33 01 30 81 Underground Ducts And Utility Structures 33 05 07 13 Trenchless Excavation Using Microtunneling 33 14 13 23 Sand Drains 33 14 13 23a Hydronic Distribution 33 14 13 23b Ground-Loop Heat-Pump Piping 33 42 11 00 Storm Drainage 33 42 13 13 Culverts
34 Transportation
34 41 13 00 Electrical Traffic Control Signals 34 71 13 13 Beam-Type Guardrail 34 71 13 16 Active Vehicle Barriers
35 Waterway and Marine Construction
35 22 26 00 Sluice Gate
41 Material Processing and Handling Equipment
41 22 23 13 Material Handling Hoists 41 22 23 13a Monorails With Air Motor Powered Hoist 41 22 23 13b Monorails With Electric Powered Hoists 41 22 23 13c Monorails With Manual Hoist 41 22 23 23 Ash Hoists
TOC - 12 Patrick Space Force Base
THIS PAGE INTENTIONALLY LEFT BLANK
01 - General Requirements
January 2022 General Requirements and Conditions Patrick Space Force Base 01 20 00 00 - 1
SECTION 01 20 00 00 - GENERAL REQUIREMENTS AND CONDITIONS
INTRODUCTION
1-1 BACKGROUND
Unified Facilities Criteria (UFC) provide common requirements across DoD for safety, sustainability, durability, and functionality for DoD facilities. UFC incorporate a combination of consensus building codes, DoD-defined technical and user requirements, and applicable statutory and regulatory requirements.
1-2 PURPOSE AND SCOPE
UFC 1-200-01 represents the foundational document of the UFC program in providing general building requirements and overarching criteria, establishing the use of consensus building codes and standards, establishing criteria implementation rules and protocols (including core UFC), and identifying unique military criteria. In accordance with the authority in MIL-STD-3007, UFC are prepared by DoD committees called Discipline Working Group (DWG), and are published by the Military Services under the authority of the Engineering Senior Executive Panel (ESEP), comprised of the following:
• Deputy Assistant Secretary of Defense (Facilities Management) Office of the Assistant Secretary of Defense (Sustainment)
• Chief, Engineering and Construction Division, Headquarters United States Army Corps of Engineers (HQ USACE)
• Chief Engineer, Naval Facilities Engineering Command (NAVFAC)
• Department of the Air Force, Deputy Director of Civil Engineers DCS Logistics, Engineering & Force Protection
1-3 APPLICABILITY
This UFC applies to the planning, design, construction, sustainment, restoration, and modernization of DoD-owned facilities. It is applicable to all methods of project delivery and levels of construction as defined below.
For facilities supporting military operations see Paragraph 1-3.5.
1-3.1 Implementation, Administration, and Enforcement
UFC are effective upon issuance for projects as follows:
• Design-Bid-Build projects that have not proceeded beyond 35% design completion.
• Design-Build projects that have not proceeded beyond date of Request for Proposal (RFP) issuance. When an RFP is issued in multiple phases or steps use the date of the last phase of the RFP issuance.
• Projects that have a delay, either planned or unintentional, of more than 18 months between design completion and the solicitation of offers for construction must be re-evaluated to determine if any design revision is necessary due to changes in criteria (including codes and standards) or site infrastructure (for example, water supply for fixed fire suppression systems, water for hose stream allowances, or fire department vehicle access). Note: The evaluation must also include retroactive requirements that have been included in the new editions of the criteria.
1-3.2 Levels of Construction
General Requirements and Conditions January 2022
01 20 00 00 - 2 Patrick Space Force Base
1-3.2.1 Permanent Construction
Buildings and facilities designed and constructed to serve a life expectancy of more than 25 years.
1-3.2.2 Semi-permanent Construction
Buildings and facilities designed and constructed to serve a life expectancy of more than 5 years, but less than 25 years. This construction level is typically only used for support of military operations. Expediency of construction and material availability may be a factor. Facilities are intended to have a more enduring presence with operational characteristics and functional performance similar to permanent construction.
Maintainability of finishes and systems must be commensurate with facility life expectancy and available maintenance capabilities. A moderate level of energy and water efficiency must be considered.
1-3.2.3 Temporary Construction
Buildings and facilities designed and constructed to serve a life expectancy of five years or less using low cost construction. Temporary construction typically cannot be economically converted to a higher level of construction. Temporary facilities have limited flexibility for conversion and re-use.
1-3.3 Waivers and Exemptions
A waiver provides authority to deviate from a criteria requirement for a specific period, typically 12 months. An exemption provides authority to deviate from a requirement indefinitely. Refer to MIL-STD-3007 for the waiver and exemption request and approval process. When additional coordination for waivers or exemptions is required due to a regulatory or functional authority, the affected criteria document will include additional information.
1-3.4 UFC Hierarchy
UFC 1-200-01 is the overarching document for buildings and facilities used by DoD. UFC 1-200-01 directs the use of the International Building Code® (IBC), the International Existing Building Code® (IEBC), Core UFC, other UFC as applicable to the building, facility, structure, or system, and Facility Criteria (FC) as they pertain to the applicable DoD Component.
1-3.4.1 UFC 3- Series
The UFC 3- Series and FC 3- Series (simply referred to as UFC 3- Series) provide discipline specific criteria requirements for the various engineering disciplines.
• If conflict occurs between a UFC 3- Series and UFC 3-600-01, the requirements of UFC 3-600-01 take precedence.
• If conflict occurs between two UFC within the UFC 3- Series, the requirements of the UFC that is more detailed pertaining to that specific building, facility, structure, or system take precedence.
1-3.4.2 UFC 4- Series
The UFC 4- Series and FC 4- Series (simply referred to as UFC 4- Series) provide requirements for multi-disciplinary and facility-specific design.
• If conflict occurs between a UFC 4- Series facility type UFC and UFC 3- 600-01, the requirements of UFC 4- Series facility type UFC take precedence.
• If conflict occurs between two UFC within the UFC 4- Series, the requirements of the UFC that is more detailed pertaining to that specific building, facility, structure, or system
Patrick Space Force Base 01 20 00 00 - 3 take precedence.
• If conflict occurs between a UFC 4- Series and a UFC 3- Series, the requirements of the UFC 4- Series take precedence.
1-3.5 Facilities in Support of Military Operations
The following UFC are intended for use outside of the United States and its territories and possessions. In addition, Joint Publication (JP) 3-0, Joint Operations, provides typical examples of military operations where uses of these UFC are appropriate.
1-3.5.1 UFC 1-201-01
Use UFC 1-201-01 for design of non-permanent facilities constructed for use by DoD personnel in support of military operations.
1-3.5.2 UFC 1-201-02
Use UFC 1-201-02 to assess existing facilities for life safety and habitability for use by DoD personnel in support of military operations.
1-3.5.3 UFC 1-202-01
Use UFC 1-202-01 for design of host nation facilities that support military operations.
1-4 OVERARCHING CRITERIA OR REGULATORY REQUIREMENTS
Design and Construction must comply with Public Laws (P.L.), Executive Orders (E.O.), Code of Federal Regulations (CFR), Department of Defense Instructions (DoDI), Department of Defense Manuals (DoDM), and Department of Defense Directives (DoDD) or other higher authority documents as applicable.
1-4.1 Vending Facilities for the Blind
Verify with the using activity the requirement to provide blind-operated vending facilities in compliance with the Randolph-Sheppard Act and DoDI 1125.03. This requirement generally applies in buildings that are over 15,000 square feet (1,400 square meters) that will contain over 100 employees, but may also apply in other situations at the discretion of the using activity.
1-4.2 Nursing and Lactation Rooms
Military installations and DoD facilities should provide a private space for nursing mothers as required by the Office of the Undersecretary of Defense (OUSD) Memorandum, Department-Wide Policy for Nursing and Lactation Rooms. Use the Office of Personnel Management (OPM) Guide for Establishing a Federal Nursing Mother’s Program to implement best practices for creating a successful nursing mother’s program, consistent with the demand of the workplace and the needs of the mission. This space may not be a bathroom, and must be shielded from view and free from intrusion of others. A nursing mother’s space must be functional, with a private space with a place to sit and a flat surface, other than the floor, to place the breast pump and other supplies. Although there are no size or permanency requirements, this space must provide access to electricity for the use of a breast pump, as well as good lighting, a comfortable temperature, and proper ventilation; and be near a source of hot and cold running water. In addition, comply with any command-specific policy applicable to this requirement or applicable to the establishment of a working mothers program within the facility.
1-5 UFC AUTHORITIES
1-5.1 Engineering Senior Executive Panel
01 20 00 00 - 4 Patrick Space Force Base
UFC and FC are issued under the authority of the ESEP as identified in paragraph 1-2.
1-5.2 Component Technical Representative
The enforcement of the codes, UFC and FC as they pertain to facility projects may be delegated to the local Component Office’s Chief Engineer’s Technical Representative at the discretion of the component’s aforementioned office.
1-5.2.1 Army
The component office of responsibility is HQUSACE/CECW-EC.
1-5.2.2 Navy and Marine Corps
The component office of responsibility is NAVFAC HQ Code CI/Chief Engineer.
1-5.2.3 Air Force
The component office of responsibility is AFCEC/CFT.
1-5.3 Building Official / Authority Having Jurisdiction
The Component Office’s Chief Engineer’s local Technical Representatives are the “Building Official” or “Authority Having Jurisdiction” (AHJ) as used in the codes and standards referenced in this UFC. The terms “Building Official” and “AHJ” used in the UFC or FC criteria, reference codes, and standards are synonymous.
1-6 GENERAL BUILDING REQUIREMENTS
1-6.1 Building Codes
Use 2018 IBC and 2018 IEBC as follows:
• Use IBC, including all published errata, as the building code for DoD, except as modified by this UFC, other UFC, and FC. Where a paragraph in any chapter of IBC references a paragraph in a different chapter, the referenced chapter shall be modified as described in
CHAPTER 2.
• Use IEBC, including all published errata, except as modified by this UFC, other UFC, and FC. Where a paragraph in any chapter of IEBC references a paragraph in a different chapter, the referenced chapter shall be modified as described in CHAPTER 3.
1-6.2 Referenced Codes and Substitutions
Treat references in the DoD Building Code (see Paragraph 2-1.1) and the DoD Existing Building Code (see Paragraph 3-1.1) to other codes as follows:
• References to the International Fuel Gas Code® (IFGC) are references to NFPA 54 (ANSI Z223.1) and NFPA 58.
• References to the International Mechanical Code® (IMC) are references to UFC 3-410-01, which cites IMC.
• References to the International Plumbing Code® (IPC) are references to UFC 3-420-01, which
Patrick Space Force Base 01 20 00 00 - 5 cites IPC.
• Dismiss references to the International Property Maintenance Code® (IPMC), as IPMC is not adopted.
• References to the International Fire Code® (IFC) are references to UFC 3-600-01, which cites
NFPA 1.
• References to the International Energy Conservation Code® (IECC) are references to UFC 1- 200-02, which cites ASHRAE 90.1 and ASHRAE189.1.
• References to NFPA 70, National Electrical Code® (NEC) are references to UFC 3-501-01, which cites NFPA 70.
• References to the International Residential Code® (IRC) are references to UFC 3-600-01, which cites IRC.
1-6.3 Other Criteria
In addition to IBC as modified in CHAPTER 2, and IEBC as modified in CHAPTER 3, comply with the following criteria.
1-6.3.1 UFC
Comply with the UFC (latest version, refer to Paragraph 1-3.1) as noted herein.
1-6.3.1.1 Core UFC
Core UFC are criteria that provide requirements for the majority of traditional building systems that are prevalent on DoD facility construction projects. Core UFC also identify additional criteria such as Antiterrorism, High Performance, and Sustainable Building requirements mandated by law and policy. Comply with the Core UFC listed here, and other UFC identified in APPENDIX C as they are applicable.
• 1-200-02, High Performance and Sustainable Building Requirements
• 3-101-01, Architecture
• 3-110-03, Roofing
• 3-120-10, Interior Design
• 3-201-01, Civil Engineering
• 3-201-02, Landscape Architecture
• 3-210-10, Low Impact Development
• 3-220-01, Geotechnical Engineering
• 3-230-01, Water Storage and Distribution
• 3-230-03, Water Treatment
• 3-240-01, Wastewater Collection
• 3-301-01, Structural Engineering
• 3-310-04, Seismic Design for Buildings
• 3-401-01, Mechanical Engineering
• 3-410-01, Heating, Ventilating and Air Conditioning
• 3-420-01, Plumbing Systems
01 20 00 00 - 6 Patrick Space Force Base
• 3-490-06, Elevators
• 3-501-01, Electrical Engineering
• 3-520-01, Interior Electrical Systems
• 3-530-01, Interior and Exterior Lighting Systems and Controls
• 3-540-01, Engine-Driven Generator Systems for Backup Power Applications
• 3-550-01, Exterior Electrical Power Distribution
• 3-560-01, Electrical Safety, O&M
• 3-580-01, Telecommunications Building Cabling Systems Planning and Design
• 3-600-01, Fire Protection Engineering for Facilities
• 4-010-01, DoD Minimum Antiterrorism Standards for Buildings
• 4-010-06, Cybersecurity of Facility-Related Control Systems
• 4-021-01, Design and O&M: Mass Notification Systems
1-6.3.1.2 Other UFC
In addition to the “Core UFC”, comply with other UFC as applicable to the system, structure, or facility type defined in the scope of the construction project.
1-6.3.2 FC
The designation "FC" is for criteria that are not applicable to all DoD Components. For example: FC 4-721- 10N "Navy and Marine Corps Unaccompanied Housing" has a final "N" designation because it is used by the Navy, including its Component, the U.S. Marine Corps. FC are applicable only to the DOD Component in the title and are intended for use with unified technical requirements published in UFC. Comply with the FC for the designated facility type and the DoD Component.
1-6.3.3 Specification Requirements
Use Unified Facilities Guide Specifications (UFGS) for all projects, including Design- Build submittals, and in accordance with UFC 1-300-02. Download, use, and edit the most current UFGS database available from the Whole Building Design Guide website at http://www.wbdg.org/ccb/browse_cat.php?c=3. Modify and edit the UFGS as necessary to suit the work required by the specific project, including editing for metric or inch-pound and to reflect the latest proven technology, materials, and methods for the project. Follow Order of Precedence requirements for each Government Design Agent on use of Regional, Agency, Unified, and Other guide specifications. Other guide specifications may be used as a basis for information when not available in the UFGS.
Provide these specifications in UFGS format and modified to meet the requirements of UFC 1-300-02.
1-6.3.4 Other Military Criteria
Military criteria other than those listed in this UFC may be applicable to specific types of structures, building systems, or building occupancies. Such structures, systems, or buildings must meet the additional requirements of applicable military criteria.
1-6.3.4.1 Explosive Safety
This document does not contain requirements for explosives safety. Facilities that involve DoD Ammunition
Patrick Space Force Base 01 20 00 00 - 7 and Explosives (AE) storage, handling, maintenance, manufacture or disposal, as well as facilities within the explosives safety quantity distance (ESQD) arcs of AE facilities, must comply with the requirements found in DoDM 6055.09, as well as implementing Service criteria found in DA PAM 385-64 (Army), NAVSEA OP 5 (Navy and Marine Corps), and AFMAN 91-201 (Air Force). DoD facilities exposed to potential explosion effects from AE belonging to other nations are also required to meet DoD and Service explosives safety criteria.
Closely coordinate the planning and design of new facilities, and occupation, repair, alteration, and restoration of existing AE-related facilities, or other facilities within ESQD arcs with knowledgeable explosives safety professionals in theater, or with the Services’ Explosives Safety Centers. Coordinate as early as possible in the planning and design process to avoid issues or problems and to ensure compliance.
Facility construction or use within ESQD arcs requires review for compliance with explosives safety criteria, and must have either an approved explosives safety site plan or an approved explosives safety deviation.
Refer to the DoD Service documents mentioned above for further applicable guidance.
1-6.3.4.2 Facility Systems Safety
Safety is an important component of maintaining and operating DoD facilities. Consider safety during design.
Incorporate a hazards review into the regular design review process to ensure systems safety has been considered at the earliest phases of project development to reduce and mitigate unintentional maintenance and operational hazards. Army projects will incorporate the safety engineering practices delineated under the Facilities Systems Safety (FASS) program as prescribed under AR PAM 385- 16, System Safety Management Guide, to the extent practicable and feasible. Air Force projects will incorporate the safety engineering practices delineated in AFMAN 91-203, Air Force Consolidated Occupational Safety Instruction, to the extent practicable and feasible. For Navy the Designer of Record must follow the concepts from the most current ANSI/ASSP Z590.3, Prevention through Design: Guidelines for Addressing Occupational Hazards and Risks in Design and Redesign Processes. All DoD facilities must comply with DoDI 6055.01 and applicable Occupational Safety and Health
Administration (OSHA) safety and health standards.
1-6.3.4.3 Antiterrorism
Antiterrorism is defined as defensive measures used to reduce the vulnerability of individuals and property to terrorist acts. UFC 4-010-01 sets the minimum requirements for DoD buildings, and the Geographic Combatant Commander Antiterrorism Construction Standards address unique requirements specific to their area of responsibility. Refer to UFC 4-010-01 and the Geographic Combatant Commander Antiterrorism Construction Standards for the minimum antiterrorism requirements.
1-6.3.4.4 Physical Security
Physical security is defined as that part of security concerned with physical measures designed and placed to safeguard personnel; to prevent unauthorized access to installations, equipment, material and documents, and to safeguard them against espionage, sabotage, damage, and theft. Many buildings require some level of physical security. When required, integrate physical measures into the site, building, room, or area as applicable. DoD requirements for physical security related to specific assets are documented in DoD publications, directives, manuals, and instructions. The Services have related documents that implement the DoD policy for the Services. The main DoD documents that contain the physical security requirements for the protection of specific DoD assets are shown in Table 1-1. This does not include the policy documents associated with the protection of nuclear and chemical assets.
Table 1-1 Policy Related to Physical Security
Asset Policy and Documents
01 20 00 00 - 8 Patrick Space Force Base
Classified Information DoDM 5200.01, Volume 3, DoD Information Security Program: Protection of Classified Information;
https://www.esd.whs.mil/DD/DoD-Issuances/
Sensitive Compartmented Information (SCI)
DoDM 5105.21-Volume 1, Sensitive Compartmented Information (SCI) Administrative Security Manual:
Administration of Information and Information Systems Security; https://www.esd.whs.mil/DD/DoD-Issuances/
DoDM 5105.21-Volume 2, Sensitive Compartmented Information (SCI) Administrative Security Manual:
Administration of Physical Security, Visitor Control, and Technical Security; https://www.esd.whs.mil/DD/DoD- Issuances/
UFC 4-010-05, Sensitive Compartmented Information Facilities Planning, Design, and Construction;
https://www.wbdg.org/ffc/dod/unified-facilities-criteria-ufc/ufc-4- 010- 05/
Special Access Program (SAP) Information
DoDM 5205.07, Volume 3, DoD Special Access Program (SAP) Security Manual: Physical Security;
https://www.esd.whs.mil/DD/DoD-Issuances/
Asset Policy and Documents
Arms, Ammunition, and Explosives
DoDM 5100.76-M, Physical Security of Sensitive Conventional Arms, Ammunition, and Explosives (AA&E); https://www.esd.whs.mil/DD/DoD-Issuances/
Weapons Systems and Platforms
DoD 5200.08-R, Physical Security Program;
https://www.esd.whs.mil/DD/DoD- Issuances/ Bulk Petroleum Products
Communications Systems
Controlled Inventory Items
1-6.3.4.5 Corrosion Prevention and Control Requirements
Use the requirements in CHAPTER 4 in conjunction with other UFC requirements to design for durability and provide for a comprehensive corrosion prevention and control strategy.
1-7 CYBERSECURITY
Plan, design, acquire, execute, and maintain all control systems (including systems separate from a utility monitoring and control system) in accordance with UFC 4-010-06 and as required by individual Service Implementation Policy. Implement cybersecurity requirements to mitigate vulnerabilities to all DoD real property facility-related control systems to a level that is acceptable to the System Owner and Authorizing Official. UFC 4-010-06 provides requirements for integrating cybersecurity into the design and construction of
Patrick Space Force Base 01 20 00 00 - 9 control systems.
1-8 NON-GOVERNMENT STANDARD MODIFICATIONS
CHAPTER 2 modifies IBC and is organized by the chapter of IBC that each section modifies.
CHAPTER 3 modifies IEBC and is organized by the chapter of IEBC that each section modifies. The modifications are one of four actions, according to the following legend:
• [Addition] – Add new section, including new section number, not shown in IBC or IEBC.
• [Deletion] – Delete referenced IBC or IEBC section.
• [Replacement] – Delete referenced IBC or IEBC section or noted portion and replace it with the narrative shown.
• [Supplement] – Add narrative shown as a supplement to the narrative shown in the referenced section of IBC or IEBC.
01 20 00 00 - 10 Patrick Space Force Base
The section modifiers are identified at the end of the paragraph title. Limited commentary has been added in the chapters. Section designations for such commentary are preceded by a “[C]”, and the commentary narrative is shaded.
1-9 GLOSSARY
APPENDIX B contains acronyms, abbreviations, and terms.
1-10 REFERENCES
APPENDIX C contains a list of references used in this document. Unless otherwise specified, the most recent edition of the referenced publication.
Patrick Space Force Base 01 20 00 00 - 11
MODIFICATIONS TO IBC
2-1 CHAPTER 1 – SCOPE AND ADMINISTRATION [SUPPLEMENT]
Use IBC Chapter 1 except as modified below.
2-1.1 Section 101 – GENERAL
101.1 Title [Replacement]
These regulations shall be known as the DoD Building Code, hereinafter referred to as “this code.”
101.4 Referenced codes [Supplement] Refer to
Paragraph 1-6.2 for referenced codes. 2-1.2 Section 102
– APPLICABILITY
102.1 General [Replacement]
Where there is a conflict between a general requirement and a specific requirement, the specific requirement shall be applicable. Where, in any specific case, different sections of this code specify different materials, methods of construction or other requirements, the most restrictive shall govern. Refer to Paragraph 1-3.4 for hierarchy of UFC.
102.2 Other Laws [Replacement]
The provisions of this code shall not be deemed to nullify any provisions of local, state, or federal law. In overseas locations the SOFA, HNFA, and in some instances, BIA may govern requirements.
102.4 Referenced codes and standards [Supplement]
Refer to Paragraph 1-6.2 and Paragraph 1-6.3 for referenced codes and criteria.
2-1.3 Section 103 – DEPARTMENT OF BUILDING SAFETY [Deletion]
2-1.4 Section 104 – DUTIES AND POWERS OF BUILDING OFFICIAL
104.1 General [Replacement]
The Building Official/AHJ is a person authorized and directed to enforce the provisions of this code, UFC, or FC.
They have the authority to render interpretations of this code, UFC, or FC and to clarify the application of the provisions. Such interpretations will be in compliance with the intent and purpose of this code, UFC, or FC and will not have the effect of waiving or exempting requirements specifically provided for in this code, UFC, or FC.
For waiver and exemption process and authority refer to Section 104.10 Waivers and exemptions.
104.10 Waivers and exemptions [Replacement]
Where there are practical difficulties involved in carrying out the provisions of this code, UFC, or FC; the Building Official/AHJ shall first find that special individual case or reason makes the strict letter of this code, UFC, or FC impractical resulting in noncompliance with requirements or an increased risk to: health, accessibility, life and fire safety, structural requirements, or operational requirements. Such cases will be treated as a waiver or exemption. Waivers and exemptions to specific UFC or FC requirements are approved by the Service’s Chief Engineer, Engineering Senior Executive Panel signature authority for the Service.
01 20 00 00 - 12 Patrick Space Force Base
[C] 104.10 Waivers and exemptions [Supplement]
Avoid requests for waivers and…