Amend 03 Atch 2C Revised Fire Alarm (15 Sep 21).pdf
PDF 686 KB Posted
- Solicitation number
- FA252121B0007
View the file
Other files
Show all 20
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A B C D F G H
● 1 MANUAL PULL STATION
FACP
ANNUNCIATION
NOTIFICATION
TR
A N S M
IT
G
E N E R A L
FIR
E D
E
TE
C
TI
O N S
IG
N A L
TO
C
E N
TR
A L
S
TA
TIO
N
TR
A N S M
IT
S
U P E R V
IS
O R Y S
IG
N A L
TO
C
E N
TR
A L
S
TA
TI
O N
TR
A N S M
IT
T
R O U B
LE
S
IG
N A L
TO
C
E N
TR
A L
S
TA
TIO
N
A C
TU
A
TE
A U D
IB
LE
/V
IS
U A L
N O
TIF
IC
A
TI
O N A
P P
LI
A N C E S
E
FLOW SWITCH
TAMPER SWITCH
D
IS
P
LA
Y E
V E N T M
E S S A G E O
N F
A C P A
N D R
E C O R D E
V E N
T IN
H
IS
TO
R Y L
O G
A C
TU
A
TE
G E N E R A L
A
LA
R M
A U D
IB
LE
A
LA
R M
A N D V
IS
U A L
S
IG
N A L
A T
TH
E P
A N E L
A C
TU
A
TE
S U P E R V
IS
O R Y A
LA
R M
A U D
IB
LE
A
LA
R M
A N D V
IS
U A L
S
IG
N A L
A T T
H E P
A N E L
A C
TU
A
TE
T R O U B
LE
A
LA
R M
A U D
IB
LE
A
LA
R M
A N D V
IS
U A L
S
IG
N A L
A T
TH
E P
A N E L
R E
LE
A S E A
C C E S S C
O N
TR
O
LL
E D D
O O R
TR
A N S M
IT
S
IG
N A L
TO
A
C C E
SS
C O N
TR
O L
S Y S
TE
M
FIRE SYSTEM
CONTROL
I
L M
ANY GROUND FAULT
ANY OPEN CIRCUIT
ANY NOTIFICATION APPLIANCE SHORT CIRCUIT
IN
TE
R R U P T P
A S
Y S
TE
M A
N N O U N C E M
E N
TS
VOICE MESSAGE● ●
D
IS
A B
LE
F
IR
E A
LA
R M
N O
TI
FIC
A
TIO
N A
P P
LI
A N C E S
INTELLIGIBLE VOICE ANNOUNCEMENTS IN CASE OF TERRORIST EVENTS● ●
N
A C
TU
A
TE
A
IR
H A N D
LE
R S
H U
TD
O W
N R
E
LA
Y
● SMOKE DETECTOR ABOVE FACP
DUCT SMOKE DETECTORS
1. ALL FIRE ALARM CONSTRUCTION/INSTALLATION MUST BE IN
ACCORDANCE WITH NFPA 70, 70E, 72, 101, UFC 3-580-01, UFC 3-600-01
AND UFC 4-021-01. MATERIALS MUST BE UL LISTED/FM APPROVED FOR
USE IN FIRE ALARM SYSTEMS.
2. ALL CONSTRUCTION WILL BE GOVERNED BY THE PLANS,
SPECIFICATIONS AND ALL APPLICABLE BUILDING AND SAFETY CODES,
LAWS AND ORDINANCES.
3. CONTRACTOR MUST BE FAMILIAR WITH THE SITE, THE WORK
REQUIRED, THE CUSTOMER'S WORK PROCEDURES AND ALL OTHER
CONDITIONS THAT MAY AFFECT THE SUCCESSFUL COMPLETION OF THE
JOB PRIOR TO COMMENCEMENT OF WORK.
4. LOCATIONS OF ALL FIRE ALARM EQUIPMENT ARE APPROXIMATE AND
MAY BE RELOCATED TO AN APPROVED LOCATION. VERIFY ALL
LOCATIONS AND SPACING IN THE FIELD. CONTACT CONTRACTING
OFFICER PRIOR TO ANY FIELD CHANGES.
5. IN THE EVENT ANY ERRORS OR OMISSIONS ARE DISCOVERED IN THE
PLANS, IMMEDIATELY NOTIFY THE CONTRACTING OFFICER.
6. ALL SPECIFIC MATERIALS AND PRODUCTS IDENTIFIED IN THE PLANS
ARE INCLUDED AS THE BASIS OF DESIGN. CONTRACTOR MAY SUBMIT
EQUIVALENT PRODUCTS IN COMPLIANCE WITH THE PROJECT
SPECIFICATIONS FOR APPROVAL INSTEAD OF THOSE SPECIFIED.
7. ALL NEW FIRE ALARM WIRING MUST BE #16 AWG MINIMUM.
8. ALL NEW FIRE ALARM WIRING MUST BE CLASS B.
9. ALL NEW FIRE ALARM CONDUITS MUST BE EMT 1 INCH MINIMUM.
ENSURE CONDUIT IS NO MORE THAN 40% FILLED.
10. SEAL ALL NEW PENETRATIONS IN WALL ASSEMBLIES WITH UL RATED
AND APPROVED SEALANT TO MATCH WALL ASSEMBLY RATING.
REFERENCE ARCHITECTURAL PACKAGE FOR DETAILS.
11. CONTRACTOR TO SUBMIT COMPLETE SHOP DRAWINGS INCLUDING
FLOOR PLAN, BATTERY CALCULATIONS AND BILL OF MATERIALS SIGNED
AND SEALED BY FIRE PROTECTION ENGINEER FOR APPROVAL AND
RECORD AS-BUILTS.
GENERAL NOTES:
1. DE-ENERGIZE ALL ITEMS TO BE DEMOLISHED OR REMOVED. PERFORM
LOCKOUT/TAGOUT IN ACCORDANCE WITH OSHA 29 CFR 1910.147 AND
THE LATEST REVISION OF NFPA 70E.
2. CONTRACTOR MUST TAKE NECESSARY PRECAUTIONS AND PROVIDE
PROTECTION AS REQUIRED TO PRESERVE CONDITION OF EXISTING
UTILITIES, EQUIPMENT, FURNISHINGS, AND SURFACES NOT INDICATED
FOR REMOVAL. IT IS THE CONTRACTOR'S RESPONSIBILITY TO WORK
AROUND THE EXISTING CONDITIONS TO ACCOMPLISH THE WORK.
3. COVER ALL OPENINGS OR PENETRATIONS IN ELECTRICAL ENCLOSURES
RESULTING FROM DEMOLITION ACTIVITIES WITH METAL PLUGS
MANUFACTURED FOR THAT PURPOSE.
4. SEAL ALL WALL PENETRATIONS RESULTING FROM DEMOLITION
ACTIVITIES WITH UL RATED AND APPROVED SEALANT TO MATCH
EXISTING WALL ASSEMBLY RATING.
GENERAL NOTES - DEMOLITION:
29 CFR 1926 OSHA STANDARDS FOR CONSTRUCTION
NFPA 70 NATIONAL ELECTRICAL CODE, 2020
NFPA 70E STANDARDS FOR ELECTRICAL SAFETY, 2018
NFPA 72 NATIONAL FIRE ALARM AND SIGNALING CODE, 2019
NFPA 101 LIFE SAFETY CODE, 2018
UFC 3-600-01 FIRE PROTECTION ENGINEERING FOR FACILITIES
UFC 4-021-01 MASS NOTIFICATION SYSTEMS
CODES AND STANDARDS: ABBREVIATIONS:
AFF ABOVE FINISHED FLOOR
AWG AMERICAN WIRE GAUGE
CD CANDELA
DB DECIBEL
EMT ELECTRICAL METALLIC TUBING
FAAP FIRE ALARM ANNUNCIATOR PANEL
NFPA NATIONAL FIRE PROTECTION ASSOCIATION
OSHA OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION
RM ROOM
FACP FIRE ALARM CONTROL PANEL
UFC UNIFIED FACILITIES CRITERIA
CFR CODE OF FEDERAL REGULATIONS
LEGEND:
FIRE ALARM / MASS NOTIFICATION SPEAKER STROBE COMBINATION DEVICE
PHOTOELECTRIC SMOKE DETECTOR
FIRE ALARM CONTROL PANEL WITH INTEGRATED AUTONOMOUS CONTROL UNIT
MANUAL PULL STATIONF
MASS NOTIFICATION VISUAL TEXT DEVICET
MASS NOTIFICATION LOCAL OPERATING CONSOLE
FACP
LOC
NON-FUSED FIRE ALARM DISCONNECT SWITCH
SPD SURGE PROTECTION DEVICE
PHOTOELECTRIC SMOKE DETECTOR (WALL MOUNTED)
F
FLOW SWITCH
TAMPER SWITCH
FS
TS
SHEET
IDENTIFICATION
1 2 3 4 5
D
C
B
A
C O
N T
R A
C T
N O
D R
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
D E
L
IV
E R
Y O
R D
E R
N O
C
K D
B Y x
F
IL
E N
U M
B E
R
P L
O T
S C
A L E
P L
O T
D A
T E
T R
A C
E S
T E
C H
N
IC
A L R
A N
G E
A R
C H
IT
E
C T
U R
A L E
N G
IN
E
E R
IN
G
S E
R V
IC
E
S
A A rh o d e s b ri to
A
C
H
I T
E
S
T H
S P
A C
E W
IN
G
C C
A F
S F
L
A s i n d ic a te d
/1
/2
:4
:2
A
M
R E
N O
V A
T
IO
N S
T O
S T
O R
M A
G A
G
F A
C
IL
IT
Y
B
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
FA-001
F
IR
E A
L A
R M
G E
N E
R A
L N
O T
E S
L E
G E
N D
A N
D A
B B
R E
V
IA
T
IO
N S
D B
E H
-1
F A
-0
F A
-1
-F
A
S E
P T
E M
B E
R
F A
F A
F A
-1
-F A
J P
B H
S J
C h e c k e r
FIRE ALARM I/O MATRIX
MARK DESCRIPTION DATE APPR
REF.
LOC
FACP
A
B
A.3
A.6
MEZZANINE RAILING
STORAGE
F
(TYP.)
1 2 3 654
A
B
A.3
A.6
OFFICE
GARAGE
STORAGE
TOILET
SHOWER
104B
HALL
F
F
F
F
F F
F
F
F
F
(TYP.)
(TYP.)
F
TT
(TYP.)
FS TS
FIRE RISER
PA EQ. CABINET (ETR) 11
B
B
B
B
B
B
B
SHEET
IDENTIFICATION
1 2 3 4 5
D
C
B
A
C O
N T
R A
C T
N
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
D E
L
IV
E R
Y O
R D
E R
N O
C
K D
B Y x
F
IL
E N
U M
B E
R
P L
O T
S C
A L E
P L
O T
D A
T E
T R
A C
E S
T E
C H
N
IC
A L R
A N
G E
A R
C H
IT
E
C T
U R
A L E
N G
IN
E
E R
IN
G
S E
R V
IC
E
S
A A rh o d e s b ri
T H
S P
A C
E W
IN
G
C C
A F
S F
L
/8
/1
/2
:4
:2
A
M
R E
N O
V A
T
IO
N S
T O
S T
O R
M A
G A
G
F A
C
IL
IT
Y
B
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
FA-102
F
IR
E A
L A
R M
P L
A N
D B
E H
-1
F A
-1
F A
-1
-F
A
S E
P T
E M
B E
R
F A
F A
F A
-1
-F A
J P
B H
S J
S J
PLAN NORTH PLAN NORTH
04 8 16268
SCALE: 1/8"=1'-0"
KEY NOTES:
1. INSTALL NEW 30A, 1P, 240VAC NONFUSED DISCONNECT SWITCH
EQUIPPED WITH SURGE PROTECTION DEVICE TO SUPPLY NEW FIRE
ALARM CONTROL PANEL.
2. INSTALL NEW SIEMENS MODEL FD0421 OR APPROVE EQUAL
PHOTOELECTRIC SMOKE DETECTOR, WALL MOUNTED, WITHIN THREE
(3) FEET OF THE FACP.
3. INSTALL NEW SIEMENS FIRE FINDER XLSV OR APPROVED EQUAL FIRE
ALARM CONTROL PANEL, BATTERIES AND BATTERY CABINET AS
REQUIRED. NEW FACP MUST BE EQUIPPED WITH INTEGRATED
AUTONOMOUS CONTROL UNIT FOR MASS NOTIFICATION. CONNECT
NEW FACP TO NEW RADIO TRANSMITTER.
4. NOT USED
5. INSTALL NEW SIEMENS MODEL HMS-D OR APPROVED EQUAL MANUAL
PULL STATION AT 48 INCHES AFF.
6. INSTALL NEW WALL MOUNTED VISUAL TEXT NOTIFICATION DEVICE
OVER EGRESS DOOR, COORDINATE MOUNTING HEIGHT WITH EXIT
SIGNS IN ELECTRICAL PACKAGE.
7. INSTALL NEW SIEMENS MODEL SE-MC-R OR APPROVED EQUAL
SPEAKER/STROBE COMBINATION APPLIANCE AT 90 INCHES AFF.
8. INSTALL NEW MASS NOTIFICATION LOCAL OPERATING CONSOLE.
9. INSTALL TAMPER SWITCH ON FIRE RISER. COORDINATE WITH FIRE
SUPPRESSION CONTRACTOR ON EXACT PLACEMENT OF DEVICE.
10. INSTALL FLOW SWITCH ON FIRE RISER. COORDINATE WITH FIRE
SUPPRESSION CONTRACTOR ON EXACT PLACEMENT OF DEVICE.
11. CONNECT EXISTING PA EQUIPMENT CABINET TO NEW FACP/ACU.
GENERAL NOTES:
1. SUPPLY ALL NEW FIRE ALARM END DEVICES FROM NEW FACP USING
MINIMUM OF #16 AWG CONDUCTORS IN 3/4 INCH CONDUIT.
1/8" = 1'-0"FA-102
A4 MEZZANINE LEVEL FIRE ALARM PLAN
1/8" = 1'-0"FA-102
A2 GROUND LEVEL FIRE ALARM PLAN
MARK DESCRIPTION DATE APPR
B AURAL WARNING SYSTEM REMOVAL AND TELECOMM
GROUND BUS ADDITION
09/08/21 SJ
B
F F
FFFFF
F
F F
TT
F F
SPD
HIGH BAY
NW WALL RM 101
120VAC
PNL LP2
CKT 42
BATTERY
HIGH BAY
NW WALL
FIRE ALARM CONTROL PANEL
WITH INTEGRATED ACU
HIGH BAY
SE WALL
LOC
HIGH BAY
NW WALL
HALL ENTRANCE
HIGH BAY
N WALL
HIGH BAY
E WALL
HIGH BAY
S WALL
HALL
TOILET
STORAGE OFFICE
SHOWER
ENTRANCEHALL
ENTRANCE
MEZZANINE
TS
FS
HIGH BAY
NW WALL
HIGH BAY
SW WALL
PA CABINET
SUPPLY
DUCT
RETURN
DUCT
SHEET
IDENTIFICATION
1 2 3 4 5
D
C
B
A
C O
N T
R A
C T
N
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
D E
L
IV
E R
Y O
R D
E R
N O
C
K D
B Y x
F
IL
E N
U M
B E
R
P L
O T
S C
A L E
P L
O T
D A
T E
T R
A C
E S
T E
C H
N
IC
A L R
A N
G E
A R
C H
IT
E
C T
U R
A L E
N G
IN
E
E R
IN
G
S E
R V
IC
E
S
A A rh o d e s b ri
T H
S P
A C
E W
IN
G
C C
A F
S F
L
/1
/2
:4
:2
A
M
R E
N O
V A
T
IO
N S
T O
S T
O R
M A
G A
G
F A
C
IL
IT
Y
B
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
FA-601
F
IR
E A
L A
R M
R
IS
E R
D
IA
G R
A M
D B
E H
-1
F A
-6
F A
-1
-F
A
S E
P T
E M
B E
R
F A
F A
F A
-1
-F A
J P
B H
S J
C h e c k e r
FIRE ALARM RISER DIAGRAM
SCALE: NONE
MARK DESCRIPTION DATE APPR
B AURAL WARNING SYSTEM REMOVAL AND TELECOMM
GROUND BUS ADDITION
09/08/21 SJ
B
1 2 3 654
B
A.3
A.6
SHEET
IDENTIFICATION
1 2 3 4 5
D
C
B
A
C O
N T
R A
C T
N
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
D E
L
IV
E R
Y O
R D
E R
N O
C
K D
B Y x
F
IL
E N
U M
B E
R
P L
O T
S C
A L E
P L
O T
D A
T E
T R
A C
E S
T E
C H
N
IC
A L R
A N
G E
A R
C H
IT
E
C T
U R
A L E
N G
IN
E
E R
IN
G
S E
R V
IC
E
S
A A rh o d e s b ri
T H
S P
A C
E W
IN
G
C C
A F
S F
L
/8
/1
/2
:4
:2
A
M
R E
N O
V A
T
IO
N S
T O
S T
O R
M A
G A
G
F A
C
IL
IT
Y
B
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
FAD-101
F
IR
E A
L A
R M
D E
M O
L
IT
IO
N
P L
A N
D B
E H
-1
F A
D -1
F A
-1
-F
A
S E
P T
E M
B E
R
F A
F A
F A
-1
-F A
J P
B H
S J
C h e c k e r
KEY NOTES:
1. DEMOLISH FIRE ALARM SYSTEM INCLUDING FACP, BATTERIES, BATTERY
CABINET, RADIO TRANSMITTER, ANTENNA, END DEVICES, CONDUCTORS
AND CONDUIT.
PLAN NORTH
04 8 16268
SCALE: 1/8"=1'-0"
1/8" = 1'-0"FAD-101
B2 FIRE ALARM DEMOLITION PLAN
MARK DESCRIPTION DATE APPR
| Sheets |
| FA-001 - FIRE ALARM GENERAL NOTES, LEGEND AND ABBREVIATIONS |
| FA-102 - FIRE ALARM PLAN |
| FA-601 - FIRE ALARM RISER DIAGRAM |
| FAD-101 - FIRE ALARM DEMOLITION PLAN |
File details come from the government source that posted it. Updated .