This document is a Request for Information (RFI) for an AV Buildout project at Tinker Air Force Base, detailing technical specifications for audiovisual systems across multiple conference rooms with classified network requirements. The project involves installing eight 85" Samsung and one 75" LG monitors, along with six to seven government-furnished equipment (GFE) computers per conference room, supporting multiple network classifications including NIPR, SECRET, TS, and TS/SCIF. Each conference room will have specific configuration needs, including video teleconferencing (VTC) capabilities, codec support, and content sharing requirements.
The solicitation (F3YCBN5133A001) is a Firm Fixed Price contract with a 90-day performance period, evaluated using a lowest price technically acceptable (LPTA) methodology. Key requirements include TAA-compliant equipment, on-site training, and support for Microsoft Teams in select rooms. A mandatory site visit is scheduled for 26 June 2025 at 10:00 AM CST, with point of contact Darrius Miller. The project involves complex audiovisual integration across multiple security domains, requiring careful consideration of network separation, microphone configurations, display technologies, and control system implementations.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| F3YCBN5133A001- AV Buildout B9201 Questions and Answers.docx | DOCX document | |
| Video Wall size.pdf | ||
| F3YCBN5133A001 Additional Questions.docx | DOCX document | |
| 9201 AV SOO.docx | DOCX document | |
| AV Buildout LOM.xlsx | XLSX spreadsheet |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| QUESTION | ANSWER | ||
| 1 | General | Can you provide a complete list of Government-Furnished Equipment (GFE) - model numbers, quatities? | eight (8) 85" Samsung Mfr Part No: QB85C-N and one (1) LG Electronics Mfr Par No:75UL3J-E |
| 2 | General | In each room/space, can the government clarify classification domains (NIPR, SIPR, JWICS) needs in each space? | Conference Room 1: one (1) NIPR, three (3) SECRET, one (1) TS, and one (1) TS/SCIF; |
Conference Room 2: two (2) SECRET, one (1) TS and two (2) TS/SCIF; Conference Room 3: one (1) NIPR, three (3) SECRET, one (1) TS, and one (1) TS/SCIF;
Conference Room 4: one (1) NIPR, three (3) SECRET, one (1) TS, and one (1) TS/SCIF;
Conference Room 5: one (1) NIPR, three (3) SECRET, one (1) TS, and one (1) TS/SCIF.
| 3 | General | If additional electrical circuits or outlets are needed ar those to be provided by base facilities, or must bidders add to RFQ as part of their bid? | This will be done by base facilities. But this information will need to be added to the quote. |
| 4 | General | What is the period of performance on this project? | It will be a 60 day completion once given the notice to proceed. This building is still undergoing construction modifications and it could still be delayed until late 2025 even after contract award. Vendor should noet that this will not start as soon as contract is awarded. |
| 5 | General | Will there be a single VTC codec used in each space or will there be multiple? What are the classifications of the codec(s)? | There will be one Codec for SECRET and TS, TS/SCIF |
| 6 | General | Is there a requirement to be capable of participating in MS Teams meetings in these spaces? | Yes, in Conference Room 1, Conference Room 4, and Conference Room 5 via NIPR. |
| 7 | General | Is there a room status (classification/mic status/etc.) signage requirement for the rooms? If so, is the signage required internal and external? | No, this is not needed. |
| 8 | General | Are GFE wall mounts to be provided to support installation of GFE monitors? If so, what is the make/model number of these? | Yes, Manhattan Full-Motion TV Wall Mount for the 75" Part No"461290 |
Samsung Part No: 757J7U3
| 9 | General | Is there a requirement to share content (GFE PCs output) during a VTC? | Yes. |
| 10 | General | Is there a requirement for HDMI extenders to be supported by fiber, no copper, connectivity? | Fiber is preferred to meet tempest separation requirements |
| 11 | General | What are the exact model numbers of the GFE Cisco VTC codecs? | We only have one at the moment. Model . We do not have these yet for the rest of the conference rooms. These cannot be requested until after accreditation of the building. |
| 12 | General | It is assumed that a control system with touch panel is to be installed to operate these rooms. Can you confirm this is accurate? Is the a specific manufacturer you would like to be used here? | Yes, as long as device is TAA compliant |
| 13 | Room 145 | Can you confirm there is to be a single 85" monitor used in this room? | There are two (2) monitors on the wall with the door |
| 14 | Room 145 | Six GFE PCs have been requested for use in this room. Are these to be single output? What is the classifications/qty. to be used in this space? Are the PCs to be loctaed in a credenza? | Dual output is needed with the capability to use VTC and second input source. |
Conference Room 1: one (1) NIPR, three (3) SECRET, one (1) TS, and one (1) TS/SCIF;
The computers do not need to be located in the credenza, alternate solution proposal requested/welcomed.
| 15 | Room 145 | Can you confirm that table (push to mute) microphones are required? If not, is a ceiling microphone an option? | Ceiling microphones can be used. These can be phyical or digital mute buttons. |
| 16 | Room 147 | Can you confirm there is to be a dual 85" monitor used in this room? | yes, on the wall with the door, one (1) on each side of the door |
| 17 | Room 147 | Six GFE PCs have been requested for use in this room. Are these to be dual output? What is the classifications/qty. to be used in this space? Can you confirm that it is a requirement to support extended desktop functionality? Are the PCs to be located in a credenza? | Dual output is needed with the capability to use VTC and second input source. Must be in line with tempest separation requirements. |
Conference Room 2: two (2) SECRET, one (1) TS and two (2) TS/SCIF;
The computers do not need to be located in the credenza, alternate solution proposal requested/welcomed.
| 18 | Room 147 | Can you confirm that table (push to mute) microphones are required? If not, is a ceiling microphone an option? | Ceiling microphones can be used. These can be phyical or digital mute buttons. |
| 19 | Room 148 | Can you confirm there is to be a dual 85" monitor used in this room? | Yes, on the wall to the left of the door |
| 20 | Room 148 | Six GFE PCs have been requested for use in this room. Are these to be dual output? What is the classifications/qty. to be used in this space? Can you confirm that it is a requirement to support extended desktop functionality? Are the PCs to be located in a credenza? | Dual output is needed with the capability to use VTC and second input source. |
Conference Room 3: one (1) NIPR, three (3) SECRET, one (1) TS, and one (1) TS/SCIF;
The computers do not need to be located in the credenza, alternate solution proposal requested/welcomed.
| 21 | Room 148 | Can you confirm that table (push to mute) microphones are required? If not, is a ceiling microphone an option? | Ceiling microphones can be used. These can be phyical or digital mute buttons. |
| 22 | Room 129 | Can you confirm that the scope for this room is limited to install a GFE display and GFE Cisco video/sound bar? | This needs to have the same cability as the other conference rooms. |
| 23 | Room 149 | Please confirm which display option we should price. Dual 2x2 LCD video walls? Ultra Wide direct-view LED video wall? | Please, price both of these options |
| 24 | Room 149 | Is the a video wall processor required to enable multiple windows to be displayed on video wall? | yes |
| 25 | Room 149 | Is there a VTC requirement in this space? If so, what networks will need to be supported? How many cameras are required (front/back)? | yes. |
Conference Room 4: one (1) NIPR, three (3) SECRET, one (1) TS, and one (1) TS/SCIF; one front for large scale meeting, one back for presenter.
VTC will be provided camera with codec once building accreditation is completed.
26 Room 149 Seven GFE PCs have been requested for use in this room. Are these to be dual output? What is the classifications/qty. to be used in this space? Can you confirm that it is a requirement to support extended desktop functionality? Are the PCs to be located in a credenza? These PCs will be located in the media room 149A (media closet).
Yes, they will need ability to be dual outputs.
Conference Room 5: one (1) NIPR, three (3) SECRET, one (1) TS, and one (1) TS/SCIF.
Yes, they will need to be controlled at the desk by the media closet.
| 27 | Room 149 | Can we use ceiling microphone in this space? | Ceiling microphones can be used. These can be phyical or digital mute buttons. |
| 28 | Room 149 | How many location will need to have a touch panel for system control? | Main desk and podium |
| 29 | Room 149 | Can you confirm that in addition to the video wall(s) there will be a confidence monitor and desktop monitor at the coontrol station that will be required? | Yes, there will be both. |
| 30 | General | Are cleared resources required for installation? | Equipment needs to be TAA compliant, personnel can be escorted. |
Note: There will need to be a mount/shelf for the camera for the AF7 to sit on in each conference room. The ones that will require Teams capapbility will need cameras added for NIPR connection that will be separate from the ones used for the AF7. Conference Room 4 will need that NIPR camera in the front and back with the ability ability to select the view wanted (presenter/crowd).