HAZMAT1.pdf

PDF 426 KB Posted

Attached to
Modular HAZMAT Storage Container Federal contract opportunity
Solicitation number
F1C0RH4216A007
Issued by
Department of the Air Force Pacific Air Forces

About this file

Contrainer Drawings

View the file

Other files for this federal contract opportunity

Other files attached to Modular HAZMAT Storage Container, newest first.
File Type Posted
RFI_5.docx DOCX document
HAZMAT_Container_RFI_4.docx DOCX document
HAZMAT1.pdf PDF
HAZMAT_Container_RFI_3.docx DOCX document
HAZMAT_Container_RFI_3.docx DOCX document
ADDITIONAL_INFORMATION.docx DOCX document
RFI_HAZMAT_Container.docx DOCX document
554_RHS_HAZMAT_CONTAINER_REQUIREMENTS_PROSPECTUS_(As_of_15_Sep_14).docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SEMPER DUCIMUS…ALWAYS LEAD! 1

BASIC STRUCTURAL FEATURES

Installation: Requesting the container be turn-key.

Fabrication: Pre-fabricated (Galvanized or Corrugated Steel).

Delivery: Yes.

Color: Painted, Tan/Neutral (preferred).

Design: Yes.

Warranty: Yes. 1-5 yrs required.

Service Support: Yes.

Minimum Size:

Nominal: 31ft x 9ft x 8ft

Exterior: 30ft x 8ft x 7ft

Interior: 29ft x 7ft x 6ft

Maximum Size:

Nominal: 67ft x 25ft x 11ft

Exterior: 66ft x 24ft x 10ft

Interior: 65ft x 23ft x 9ft

SEMPER DUCIMUS…ALWAYS LEAD! 2

BASIC STRUCTURAL FEATURES CONT…

Fixed Fire Protection System: Must meet UL, ULC, NFPA 70 standards.

Fire/Gas Detection System: Must meet NFPA standards for each container’s substances.

Ventilation: Must be explosive-proof, rated for C1 group D, Division 1, hazards, enclosed weather-proof, Class A, B, C, fire rated.

Audible Alarm System: Must meet NFPA 72 standards, (i.e., bell, horn, or automated Voice etc...).

Visible Alert System: Must meet NFPA 72 standards, (i.e., strobe, flashing red light, etc…).

Electrical System: Must meet UL, ULC, NFPA 70.

Static Grounding System: Yes.

Climate Controlled (A/C): Must meet 35-70 F, 40 CFR, NFPA 30, EPA UL, standards.

Racks: Yes.

Flooring (Grating): Yes.

Doors: Must be double door, meet UL, DOT, and NFPA labeling standards.

Ramps: Yes.

Separate Spill Containment per each section: Must meet EPA 40 CFR, NFPA 30, IFC and UFC standards.

SEMPER DUCIMUS…ALWAYS LEAD! 3

BUILDING MUST MEET MINIMUM

NATIONAL REQUIRED CODES

NFPA Standards Code 30 Flammables, Combustibles, Solvents, Paints Code 55 Compressed Gasses Code 58 Liquefied Petroleum Gasses Code 400 All Hazardous Materials Code 434 Pesticides

All Applicable OSHA Standards Flammables, Combustibles, Solvents, Paints Compressed Gasses Liquefied Petroleum Gasses All Hazardous Materials Pesticides

All Applicable EPA Standards Flammables, Combustibles, Solvents, Paints Compressed Gasses Liquefied Petroleum Gasses All Hazardous Materials Pesticides

SEMPER DUCIMUS…ALWAYS LEAD! 4

FLAMMABLE ITEMS TO BE STORED

Battery Cleaner

Brake Cleaner

Adhesive, Pipe, PVC

SEMPER DUCIMUS…ALWAYS LEAD! 5

Aerosol, Spray Paint

Cleaner, Electrical Contacts

Epoxy Resin, Steel

CONT…

SEMPER DUCIMUS…ALWAYS LEAD! 6

Sealant, Plastic Urethane

Sealant Corrosive Preventive, Aerosol

Polyurethane Foam, Aerosol

SEMPER DUCIMUS…ALWAYS LEAD! 7

Pipe Cleaner, PVC

Sealant, Caulk, Silicone, Interior/Exterior

Adhesive, Insulation + Duct Liner, Aerosol

SEMPER DUCIMUS…ALWAYS LEAD! 8

COMBUSTIBLE ITEMS TO BE STORED

Refrigerant R134A

Various Gases

Anti-freeze/Coolant

SEMPER DUCIMUS…ALWAYS LEAD! 9

Battery, Sealed Lead-Acid

CORROSIVE ITEMS TO BE STORED

Solvent Cleaner, Degreaser

Additive, Diesel Fuel, Exhaust Fluid

SEMPER DUCIMUS…ALWAYS LEAD! 10

Gojo, Cleaning Compound

Simple Green Cleaning Compound

Absorbent, Cleaning Compound

CORROSIVE ITEMS TO BE STORED

SEMPER DUCIMUS…ALWAYS LEAD! 11

Soad, Grit

Lubricants

CORROSIVE ITEMS TO BE STORED

SEMPER DUCIMUS…ALWAYS LEAD! 12

BASIC FRONT CONTAINER DESIGN

NOTE: All doors/individual entryways MUST be individually marked with the appropriate hazard placards and/or labels. Entry way shall be double door, have entry ramps and be self closing.

A/C & FIRE

SYS

SEMPER DUCIMUS…ALWAYS LEAD! 13

INTERIOR CONTAINER DESIGN

(2x) 3-Shelf units left & right side of container. Must be 4’ deep.

(3x) 3-Shelf units left, right side, and rear of container.

Must be 4’ deep.

(3x) 3-Shelf units left, right side, and rear of container.

Must be 4’ deep.

Cage separating Cylinders

(2x) 3-Shelf units left and right side of container. Must be 4’ deep.

TOP VIEW

Lubricants (55-Gal Drums Oil)

Full Empty

Shelved Items

Cleaning Compounds

Solvents

Batteries

Battery

Cleaners Adhesives Electrical

Cleaners Epoxy Resins Spray Paints Sealants Foams Pipe Cleaners

Cleaning Compounds

Solvents

Batteries

Caged (C) & Shelved (S) Items

Argon (C) Acetylene (C) Helium (C) Carbon Dioxide

(C) Oxygen (C) Antifreeze (S) Coolants (S) Refrigerants

(S)

CORROSIVES

CORROSIVES COMBUSTIBLES FLAMMABLES

A/C & FIRE

SEMPER DUCIMUS…ALWAYS LEAD! 14

EXTERIOR CONTAINER A/C & DRY CHEM

FIRE SYSTEM

A/C UNIT

DRY

CHEM

FIRE

SYS

A/C UNIT DRY

CHEM

FIRE

Left Side (END) View Right Side (END) View