HAZMAT1.pdf
PDF 426 KB Posted
- Attached to
- Modular HAZMAT Storage Container Federal contract opportunity
- Solicitation number
- F1C0RH4216A007
About this file
Contrainer Drawings
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| RFI_5.docx | DOCX document | |
| HAZMAT_Container_RFI_4.docx | DOCX document | |
| HAZMAT1.pdf | ||
| HAZMAT_Container_RFI_3.docx | DOCX document | |
| HAZMAT_Container_RFI_3.docx | DOCX document | |
| ADDITIONAL_INFORMATION.docx | DOCX document | |
| RFI_HAZMAT_Container.docx | DOCX document | |
| 554_RHS_HAZMAT_CONTAINER_REQUIREMENTS_PROSPECTUS_(As_of_15_Sep_14).docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SEMPER DUCIMUS…ALWAYS LEAD! 1
BASIC STRUCTURAL FEATURES
Installation: Requesting the container be turn-key.
Fabrication: Pre-fabricated (Galvanized or Corrugated Steel).
Delivery: Yes.
Color: Painted, Tan/Neutral (preferred).
Design: Yes.
Warranty: Yes. 1-5 yrs required.
Service Support: Yes.
Minimum Size:
Nominal: 31ft x 9ft x 8ft
Exterior: 30ft x 8ft x 7ft
Interior: 29ft x 7ft x 6ft
Maximum Size:
Nominal: 67ft x 25ft x 11ft
Exterior: 66ft x 24ft x 10ft
Interior: 65ft x 23ft x 9ft
SEMPER DUCIMUS…ALWAYS LEAD! 2
BASIC STRUCTURAL FEATURES CONT…
Fixed Fire Protection System: Must meet UL, ULC, NFPA 70 standards.
Fire/Gas Detection System: Must meet NFPA standards for each container’s substances.
Ventilation: Must be explosive-proof, rated for C1 group D, Division 1, hazards, enclosed weather-proof, Class A, B, C, fire rated.
Audible Alarm System: Must meet NFPA 72 standards, (i.e., bell, horn, or automated Voice etc...).
Visible Alert System: Must meet NFPA 72 standards, (i.e., strobe, flashing red light, etc…).
Electrical System: Must meet UL, ULC, NFPA 70.
Static Grounding System: Yes.
Climate Controlled (A/C): Must meet 35-70 F, 40 CFR, NFPA 30, EPA UL, standards.
Racks: Yes.
Flooring (Grating): Yes.
Doors: Must be double door, meet UL, DOT, and NFPA labeling standards.
Ramps: Yes.
Separate Spill Containment per each section: Must meet EPA 40 CFR, NFPA 30, IFC and UFC standards.
SEMPER DUCIMUS…ALWAYS LEAD! 3
BUILDING MUST MEET MINIMUM
NATIONAL REQUIRED CODES
NFPA Standards Code 30 Flammables, Combustibles, Solvents, Paints Code 55 Compressed Gasses Code 58 Liquefied Petroleum Gasses Code 400 All Hazardous Materials Code 434 Pesticides
All Applicable OSHA Standards Flammables, Combustibles, Solvents, Paints Compressed Gasses Liquefied Petroleum Gasses All Hazardous Materials Pesticides
All Applicable EPA Standards Flammables, Combustibles, Solvents, Paints Compressed Gasses Liquefied Petroleum Gasses All Hazardous Materials Pesticides
SEMPER DUCIMUS…ALWAYS LEAD! 4
FLAMMABLE ITEMS TO BE STORED
Battery Cleaner
Brake Cleaner
Adhesive, Pipe, PVC
SEMPER DUCIMUS…ALWAYS LEAD! 5
Aerosol, Spray Paint
Cleaner, Electrical Contacts
Epoxy Resin, Steel
CONT…
SEMPER DUCIMUS…ALWAYS LEAD! 6
Sealant, Plastic Urethane
Sealant Corrosive Preventive, Aerosol
Polyurethane Foam, Aerosol
SEMPER DUCIMUS…ALWAYS LEAD! 7
Pipe Cleaner, PVC
Sealant, Caulk, Silicone, Interior/Exterior
Adhesive, Insulation + Duct Liner, Aerosol
SEMPER DUCIMUS…ALWAYS LEAD! 8
COMBUSTIBLE ITEMS TO BE STORED
Refrigerant R134A
Various Gases
Anti-freeze/Coolant
SEMPER DUCIMUS…ALWAYS LEAD! 9
Battery, Sealed Lead-Acid
CORROSIVE ITEMS TO BE STORED
Solvent Cleaner, Degreaser
Additive, Diesel Fuel, Exhaust Fluid
SEMPER DUCIMUS…ALWAYS LEAD! 10
Gojo, Cleaning Compound
Simple Green Cleaning Compound
Absorbent, Cleaning Compound
CORROSIVE ITEMS TO BE STORED
SEMPER DUCIMUS…ALWAYS LEAD! 11
Soad, Grit
Lubricants
CORROSIVE ITEMS TO BE STORED
SEMPER DUCIMUS…ALWAYS LEAD! 12
BASIC FRONT CONTAINER DESIGN
NOTE: All doors/individual entryways MUST be individually marked with the appropriate hazard placards and/or labels. Entry way shall be double door, have entry ramps and be self closing.
A/C & FIRE
SYS
SEMPER DUCIMUS…ALWAYS LEAD! 13
INTERIOR CONTAINER DESIGN
(2x) 3-Shelf units left & right side of container. Must be 4’ deep.
(3x) 3-Shelf units left, right side, and rear of container.
Must be 4’ deep.
(3x) 3-Shelf units left, right side, and rear of container.
Must be 4’ deep.
Cage separating Cylinders
(2x) 3-Shelf units left and right side of container. Must be 4’ deep.
TOP VIEW
Lubricants (55-Gal Drums Oil)
Full Empty
Shelved Items
Cleaning Compounds
Solvents
Batteries
Battery
Cleaners Adhesives Electrical
Cleaners Epoxy Resins Spray Paints Sealants Foams Pipe Cleaners
Cleaning Compounds
Solvents
Batteries
Caged (C) & Shelved (S) Items
Argon (C) Acetylene (C) Helium (C) Carbon Dioxide
(C) Oxygen (C) Antifreeze (S) Coolants (S) Refrigerants
(S)
CORROSIVES
CORROSIVES COMBUSTIBLES FLAMMABLES
A/C & FIRE
SEMPER DUCIMUS…ALWAYS LEAD! 14
EXTERIOR CONTAINER A/C & DRY CHEM
FIRE SYSTEM
A/C UNIT
DRY
CHEM
FIRE
SYS
A/C UNIT DRY
CHEM
FIRE
Left Side (END) View Right Side (END) View
| Slide Number 1 |
| Slide Number 2 |
| Slide Number 3 |
| Slide Number 4 |
| Slide Number 5 |
| Slide Number 6 |
| Slide Number 7 |
| Slide Number 8 |
| Slide Number 9 |
| Slide Number 10 |
| Slide Number 11 |
| Slide Number 12 |
| Slide Number 13 |
| Slide Number 14 |
File details come from the government source that posted it. Updated .