Plans_1354510_2014-11-21_SIGNED_(2).pdf

PDF 15 MB Posted

Attached to
RFP For PARCS Improvement at NASM-Hazy
Solicitation number
F15SOL10041
Issued by

About this file

Proposed plans for RFP F15SOL10041

View the file

Other files

File Type Posted
IT-960-TN14.pdf PDF
Geotechnical_Engineering_Report_2014-Jun-25.pdf PDF
Am_1_F15SOL10041.pdf PDF
Special-Cond-for-AE-Services-2011-Oct-03.pdf PDF
RFPF15SOL10041.pdf PDF
Past_Perf_ _Exp_PARCS.xls XLS spreadsheet
1354510_HAZY_Parking_Control_Upgrade_SPECS_(3).pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SHEET NO.

GRAPHIC SCALE(S)

KEY PLAN

BUILDING NAME

DATE

REVISION 1

REVISION

SUBMISSION

REVISION 2

REVISION 3

REVISION 4

REVISION 5

REVISION 6

REVISION

SEQUENCETYPEDISCIPLINE

CHECKED BYDRAWN BYDESIGNED BY

WORKING STAFF

DRAWING TYPE

DRAWING TITLE

PROJECT TITLE

A/E PROJECT NUMBER

OFEO PROJECT NUMBER

ADDRESS

C

11400 COMMERCE PARK DR., SUITE 400, RESTON, VA 20191

PHONE: 703-674-1300 FAX: 703-674-1350

WWW.KIMLEY-HORN.COM

NASM - UDVAR-HAZY CENTER

14930 Air & Space Museum Pkwy Chantilly, Virginia 20151

Parking Entrance Control Upgrades

Office of Facilities Engineering and Operations 600 Maryland Avenue S.W. Suite 5001

Washington DC 20024-2520

GENERAL NOTES

11/21/2014

KB JA RJM

Civil

110408000 1354510

A201

ELEVATION ORIENTATION

DETAIL NUMBER

DETAIL SHEET

ELEVATION AND DETAIL CALLOUT

A401

1 DETAIL NUMBER

DETAIL SHEET

A401A401

DETAIL NUMBER

DETAIL SHEET

REFERENCING SHEET

Design-Build Requirements Documents

GRAPHIC SCALE

1:30

30150 756045

SHEET NO.

GRAPHIC SCALE(S)

KEY PLAN

BUILDING NAME

DATE

REVISION 1

REVISION

SUBMISSION

REVISION 2

REVISION 3

REVISION 4

REVISION 5

REVISION 6

REVISION

SEQUENCETYPEDISCIPLINE

CHECKED BYDRAWN BYDESIGNED BY

WORKING STAFF

DRAWING TYPE

DRAWING TITLE

PROJECT TITLE

A/E PROJECT NUMBER

OFEO PROJECT NUMBER

ADDRESS

C

11400 COMMERCE PARK DR., SUITE 400, RESTON, VA 20191

PHONE: 703-674-1300 FAX: 703-674-1350

WWW.KIMLEY-HORN.COM

NASM - UDVAR-HAZY CENTER

14930 Air & Space Museum Pkwy Chantilly, Virginia 20151

Parking Entrance Control Upgrades

Office of Facilities Engineering and Operations 600 Maryland Avenue S.W. Suite 5001

Washington DC 20024-2520

MATCHLINE

- SEE

THIS

SHEET

M

ATC

H

LIN

E

-SEE

TH

IS

SH

EET

NORTH

NORTH

LEGEND

PAVEMENT AND CURB AREAS TO BE REMOVED

LANDSCAPE MEDIAN TO BE REMOVED

EXISTING CONDITIONS AND

DEMOLITION PLAN

11/21/2014

KB JA RJM

110408000 1354510

Civil

1" = 30'-0"C 101

EXISTING CONDITIONS AND DEMOLITION PLAN1

NOTES

1. ITEMS REMOVED SHALL BE DISPOSED OF AT THE CONTRACTOR'S

EXPENSE.

2. SEE SHEETS C102 AND C102 FOR SITE PLAN INFORMATION.

3. SEE SHEETS C104 AND C105 FOR ADDITIONAL INFORMATION ON GRADING

AND DRAINAGE.

4. SEE SHEETS C106 AND C107 FOR ADDITIONAL INFORMATION ABOUT

UTILITIES.

1:30

30150 756045

SHEET NO.

GRAPHIC SCALE(S)

KEY PLAN

BUILDING NAME

DATE

REVISION 1

REVISION

SUBMISSION

REVISION 2

REVISION 3

REVISION 4

REVISION 5

REVISION 6

REVISION

SEQUENCETYPEDISCIPLINE

CHECKED BYDRAWN BYDESIGNED BY

WORKING STAFF

DRAWING TYPE

DRAWING TITLE

PROJECT TITLE

A/E PROJECT NUMBER

OFEO PROJECT NUMBER

ADDRESS

C

11400 COMMERCE PARK DR., SUITE 400, RESTON, VA 20191

PHONE: 703-674-1300 FAX: 703-674-1350

WWW.KIMLEY-HORN.COM

NASM - UDVAR-HAZY CENTER

14930 Air & Space Museum Pkwy Chantilly, Virginia 20151

Parking Entrance Control Upgrades

Office of Facilities Engineering and Operations 600 Maryland Avenue S.W. Suite 5001

Washington DC 20024-2520

NORTH

PROPOSED MILL AND OVERLAY PAVEMENT AREAS

PROPOSED FULL DEPTH PAVEMENT AREAS

PROPOSED STORMWATER BMP AREA

LEGEND

NOTES

1. ALL DIMENSIONS TO THE FACE OF CURB

UNLESS OTHERWISE NOTED.

2. SEE SHEETS C104 AND C105 FOR ADDITIONAL

INFORMATION ON GRADING AND DRAINAGE.

3. SEE SHEETS C106 AND C107 FOR ADDITIONAL

INFORMATION ABOUT UTILITIES.

4. SEE SECURITY PLANS FOR DESIGN

INFORMATION ABOUT SECURITY GATES

PROP. HYDRAULIC CEMENT SIDEWALK

SITE PLAN

11/21/2014

KB JA RJM

110408000 1354510

Civil

MATCHLINE

- SEE

THIS

SHEET

M

ATC

H

LIN

E

-SEE

TH

IS

SH

EET

1" = 30'-0"C 102

SITE PLAN1

NORTH

GRAPHIC SCALE(S)

KEY PLAN

BUILDING NAME

DATE

REVISION 1

REVISION

SUBMISSION

REVISION 2

REVISION 3

REVISION 4

REVISION 5

REVISION 6

REVISION

SEQUENCETYPEDISCIPLINE

CHECKED BYDRAWN BYDESIGNED BY

WORKING STAFF

DRAWING TYPE

DRAWING TITLE

PROJECT TITLE

A/E PROJECT NUMBER

OFEO PROJECT NUMBER

ADDRESS

C

11400 COMMERCE PARK DR., SUITE 400, RESTON, VA 20191

PHONE: 703-674-1300 FAX: 703-674-1350

WWW.KIMLEY-HORN.COM

1:10

1050 252015

NASM - UDVAR-HAZY CENTER

14930 Air & Space Museum Pkwy Chantilly, Virginia 20151

Parking Entrance Control Upgrades

Office of Facilities Engineering and Operations 600 Maryland Avenue S.W. Suite 5001

Washington DC 20024-2520

NORTH

SITE PLAN DETAIL

11/21/2014

KB JA RJM

110408000 1354510

Civil

Reston Association Invites You

1" = 10'-0"C 103

SITE PLAN DETAIL1

Design-Build Requirements Documents

NOTES

1. ALL DIMENSIONS TO THE FACE OF CURB

UNLESS OTHERWISE NOTED.

2. SEE SHEETS C104 AND C105 FOR ADDITIONAL

INFORMATION ON GRADING AND DRAINAGE.

3. SEE SHEETS C106 AND C107 FOR ADDITIONAL

INFORMATION ABOUT UTILITIES.

4. SEE SHEETS C502 FOR ADDITIONAL

INFORMATION ABOUT THE TYPICAL ENTRY/EXIT

LANE CONFIGURATIONS.

5. SEE SHEETS C503 FOR ADDITIONAL DETAILS ON

THE CASHIER STATIONS.

6. SEE SECURITY PLANS FOR DESIGN

INFORMATION ABOUT SECURITY GATES

1:30

30150 756045

SHEET NO.

GRAPHIC SCALE(S)

KEY PLAN

BUILDING NAME

DATE

REVISION 1

REVISION

SUBMISSION

REVISION 2

REVISION 3

REVISION 4

REVISION 5

REVISION 6

REVISION

SEQUENCETYPEDISCIPLINE

CHECKED BYDRAWN BYDESIGNED BY

WORKING STAFF

DRAWING TYPE

DRAWING TITLE

PROJECT TITLE

A/E PROJECT NUMBER

OFEO PROJECT NUMBER

ADDRESS

C

11400 COMMERCE PARK DR., SUITE 400, RESTON, VA 20191

PHONE: 703-674-1300 FAX: 703-674-1350

WWW.KIMLEY-HORN.COM

NASM - UDVAR-HAZY CENTER

14930 Air & Space Museum Pkwy Chantilly, Virginia 20151

Parking Entrance Control Upgrades

Office of Facilities Engineering and Operations 600 Maryland Avenue S.W. Suite 5001

Washington DC 20024-2520

MATCHLINE

- SEE

THIS

SHEET

M

ATC

H

LIN

E

-SEE

TH

IS

SH

EET

NORTH

GRADING AND DRAINAGE PLAN

11/21/2014

KB JA RJM

110408000 1354510

Civil

PROPOSED STORMWATER BMP AREA

LEGEND

CURB INLET

PROPOSED CONTOUR

EXISTING CONTOUR

SPOT ELEVATION

SLOPE

NOTES

1. ALL SPOT SHOT ELEVATIONS ARE PAVEMENT

SURFACE UNLESS OTHERWISE NOTED.

C 104

GRADING AND DRAINAGE PLAN1

1:30

30150 756045

SHEET NO.

GRAPHIC SCALE(S)

KEY PLAN

BUILDING NAME

DATE

REVISION 1

REVISION

SUBMISSION

REVISION 2

REVISION 3

REVISION 4

REVISION 5

REVISION 6

REVISION

SEQUENCETYPEDISCIPLINE

CHECKED BYDRAWN BYDESIGNED BY

WORKING STAFF

DRAWING TYPE

DRAWING TITLE

PROJECT TITLE

A/E PROJECT NUMBER

OFEO PROJECT NUMBER

ADDRESS

C

11400 COMMERCE PARK DR., SUITE 400, RESTON, VA 20191

PHONE: 703-674-1300 FAX: 703-674-1350

WWW.KIMLEY-HORN.COM

NASM - UDVAR-HAZY CENTER

14930 Air & Space Museum Pkwy Chantilly, Virginia 20151

Parking Entrance Control Upgrades

Office of Facilities Engineering and Operations 600 Maryland Avenue S.W. Suite 5001

Washington DC 20024-2520

NORTH

GRADING AND DRAINAGE PLAN

DETAIL

11/21/2014

KB JA RJM

110408000 1354510

Civil

PROPOSED STORMWATER BMP AREA

LEGEND

CURB INLET

PROPOSED CONTOUR

EXISTING CONTOUR

SPOT ELEVATION

SLOPE

NOTES

1. ALL SPOT SHOT ELEVATIONS ARE PAVEMENT

SURFACE UNLESS OTHERWISE NOTED.

C 105

GRADING AND DRAINAGE PLAN DETAIL1

1:30

30150 756045

SHEET NO.

GRAPHIC SCALE(S)

KEY PLAN

BUILDING NAME

DATE

REVISION 1

REVISION

SUBMISSION

REVISION 2

REVISION 3

REVISION 4

REVISION 5

REVISION 6

REVISION

SEQUENCETYPEDISCIPLINE

CHECKED BYDRAWN BYDESIGNED BY

WORKING STAFF

DRAWING TYPE

DRAWING TITLE

PROJECT TITLE

A/E PROJECT NUMBER

OFEO PROJECT NUMBER

ADDRESS

C

11400 COMMERCE PARK DR., SUITE 400, RESTON, VA 20191

PHONE: 703-674-1300 FAX: 703-674-1350

WWW.KIMLEY-HORN.COM

NASM - UDVAR-HAZY CENTER

14930 Air & Space Museum Pkwy Chantilly, Virginia 20151

Parking Entrance Control Upgrades

Office of Facilities Engineering and Operations 600 Maryland Avenue S.W. Suite 5001

Washington DC 20024-2520

M

ATC

H

LIN

E

-SEE

SH

EET

C

NORTH

UTILITY PLAN

11/21/2014

KB JA RJM

110408000 1354510

Civil

Design-Build Requirements Documents

C 106

UTILITY PLAN1

1" = 30'-0"

1:30

30150 756045

SHEET NO.

GRAPHIC SCALE(S)

KEY PLAN

BUILDING NAME

DATE

REVISION 1

REVISION

SUBMISSION

REVISION 2

REVISION 3

REVISION 4

REVISION 5

REVISION 6

REVISION

SEQUENCETYPEDISCIPLINE

CHECKED BYDRAWN BYDESIGNED BY

WORKING STAFF

DRAWING TYPE

DRAWING TITLE

PROJECT TITLE

A/E PROJECT NUMBER

OFEO PROJECT NUMBER

ADDRESS

C

11400 COMMERCE PARK DR., SUITE 400, RESTON, VA 20191

PHONE: 703-674-1300 FAX: 703-674-1350

WWW.KIMLEY-HORN.COM

NASM - UDVAR-HAZY CENTER

14930 Air & Space Museum Pkwy Chantilly, Virginia 20151

Parking Entrance Control Upgrades

Office of Facilities Engineering and Operations 600 Maryland Avenue S.W. Suite 5001

Washington DC 20024-2520

M

AT

CH

LI

NE

- S

EE

TH

IS

SH

EE

T

NORTH

M

ATC

H

LIN

E

-SEE

TH

IS

SH

EET

UTILITY PLAN

11/21/2014

KB JA RJM

110408000 1354510

Civil

Design-Build Requirements Documents

C 107

UTILITY PLAN1

1" = 30'-0"

MATCHLINE

- SEE

SHEET

C106

1:30

30150 756045

SHEET NO.

GRAPHIC SCALE(S)

KEY PLAN

BUILDING NAME

DATE

REVISION 1

REVISION

SUBMISSION

REVISION 2

REVISION 3

REVISION 4

REVISION 5

REVISION 6

REVISION

SEQUENCETYPEDISCIPLINE

CHECKED BYDRAWN BYDESIGNED BY

WORKING STAFF

DRAWING TYPE

DRAWING TITLE

PROJECT TITLE

A/E PROJECT NUMBER

OFEO PROJECT NUMBER

ADDRESS

C

11400 COMMERCE PARK DR., SUITE 400, RESTON, VA 20191

PHONE: 703-674-1300 FAX: 703-674-1350

WWW.KIMLEY-HORN.COM

NASM - UDVAR-HAZY CENTER

14930 Air & Space Museum Pkwy Chantilly, Virginia 20151

Parking Entrance Control Upgrades

Office of Facilities Engineering and Operations 600 Maryland Avenue S.W. Suite 5001

Washington DC 20024-2520

NORTH

SEQUENCE OF CONSTRUCTION - PHASE I:

EROSION AND SEDIMENT

CONTROL PHASE I

11/21/2014

KB JA RJM

08110 OF 33

110408000 1354510

Civil

M

ATC

H

LIN

E

-SEE

TH

IS

SH

EET

MATCHLINE

- SEE

THIS

SHEET

1" = 30'-0"C 108

EROSION AND SEDIMENT CONTROL PHASE I1

1:30

30150 756045

SHEET NO.

GRAPHIC SCALE(S)

KEY PLAN

BUILDING NAME

DATE

REVISION 1

REVISION

SUBMISSION

REVISION 2

REVISION 3

REVISION 4

REVISION 5

REVISION 6

REVISION

SEQUENCETYPEDISCIPLINE

CHECKED BYDRAWN BYDESIGNED BY

WORKING STAFF

DRAWING TYPE

DRAWING TITLE

PROJECT TITLE

A/E PROJECT NUMBER

OFEO PROJECT NUMBER

ADDRESS

C

11400 COMMERCE PARK DR., SUITE 400, RESTON, VA 20191

PHONE: 703-674-1300 FAX: 703-674-1350

WWW.KIMLEY-HORN.COM

NASM - UDVAR-HAZY CENTER

14930 Air & Space Museum Pkwy Chantilly, Virginia 20151

Parking Entrance Control Upgrades

Office of Facilities Engineering and Operations 600 Maryland Avenue S.W. Suite 5001

Washington DC 20024-2520

NORTH

EROSION AND SEDIMENT

CONTROL PHASE II

11/21/2014

KB JA RJM

09111 OF 33

110408000 1354510

Civil

M

ATC

H

LIN

E

-SEE

TH

IS

SH

EET

MATCHLINE

- SEE

THIS

SHEET

1" = 30'-0"C 109

EROSION AND SEDIMENT CONTROL PHASE II1

SEQUENCE OF CONSTRUCTION PHASE II:

1:30

30150 756045

SHEET NO.

GRAPHIC SCALE(S)

KEY PLAN

BUILDING NAME

DATE

REVISION 1

REVISION

SUBMISSION

REVISION 2

REVISION 3

REVISION 4

REVISION 5

REVISION 6

REVISION

SEQUENCETYPEDISCIPLINE

CHECKED BYDRAWN BYDESIGNED BY

WORKING STAFF

DRAWING TYPE

DRAWING TITLE

PROJECT TITLE

A/E PROJECT NUMBER

OFEO PROJECT NUMBER

ADDRESS

C

11400 COMMERCE PARK DR., SUITE 400, RESTON, VA 20191

PHONE: 703-674-1300 FAX: 703-674-1350

WWW.KIMLEY-HORN.COM

NASM - UDVAR-HAZY CENTER

14930 Air & Space Museum Pkwy Chantilly, Virginia 20151

Parking Entrance Control Upgrades

Office of Facilities Engineering and Operations 600 Maryland Avenue S.W. Suite 5001

Washington DC 20024-2520

M

ATC

H

LIN

E

-SEE

SH

EET

C

NORTH

SIGN LEGEND

VISITOR PARKING

YOUR FEE SUPPORTS:

TUNE TO AM 1660 FOR INFORMATION

DMS (1 LINE)

EDUCATIONAL PROGRAMS,

EXHIBITIONS, ARTIFACT CARE,

OPERATIONAL COSTS

THANK YOU!

1. ALL PROPOSED SIGNING AND PAVEMENT MARKINGS SHALL BE IN ACCORDANCE WITH THE MOST CURRENT EDITION

OF EACH OF THE FOLLOWING MANUALS, OR THE MOST RECENT REVISION THERETO:

A. MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD)

B. THE VIRGINIA SUPPLEMENT TO THE MUTCD

C. THE VIRGINIA DEPARTMENT OF TRANSPORTATION ROAD AND BRIDGE SPECIFICATIONS

D. THE VIRGINIA DEPARTMENT OF TRANSPORTATION ROAD AND BRIDGE STANDARDS

2. ALL PAVEMENT MARKINGS SHALL BE TYPE B, CLASS 1, UNLESS OTHERWISE NOTED.

3. PROPOSED SIGN LOCATIONS ARE APPROXIMATE AND SHALL BE MODIFIED IN THE FIELD TO AVOID CONFLICT WITH UNDERGROUND UTILITIES OR OTHER OBSTRUCTIONS, AND TO COMPLY WITH STANDARDS REFERENCED IN NOTE 1

ABOVE.

4. ANY EXISTING PAVEMENT MARKINGS THAT WILL CONFLICT WITH PROPOSED PAVEMENT MARKINGS SHALL BE

COMPLETELY ERADICATED.

5. LIMITS SHOWN OF PROPOSED MARKINGS ARE APPROXIMATE AND SHALL BE MODIFIED IN THE FIELD TO ENSURE THAT PROPOSED PAVEMENT MARKINGS CONTINUE UNTIL EXISTING PAVEMENT MARKINGS CAN BE MATCHED.

6. ALL NEW SIGNS SHALL BE PLACED ON VDOT STP-1 POST(S).

7. ALL SIGNS WITHIN THE CLEAR ZONE SHALL BE INSTALLED ON A BREAKAWAY SUPPORT.

SIGNING AND PAVEMENT MARKING NOTES

TYPE B, CLASS 1, YELLOW, 4" WIDTH

TYPE B, CLASS 1, WHITE, 4" WIDTH

TYPE B, CLASS 1, WHITE, 4" WIDTH, 10' LONG, 30' SPACE

TYPE B, CLASS 1, WHITE 4" WIDTH, 2' LONG, 4' SPACE

PAVEMENT MARKING LEGEND

A

B

C

D

R1-1

PROPOSED

R3-8L

PROPOSED

VISITOR PARKING

YOUR FEE SUPPORTS:

TUNE TO AM 1660 FOR INFORMATION

$15 PER VEHICLE

EDUCATIONAL PROGRAMS,

EXHIBITIONS, ARTIFACT CARE,

OPERATIONAL COSTS

THANK YOU!

SIGNING AND MARKING PLAN

11/21/2014

KB JA RJM

10112 OF 33

110408000 1354510

Civil

1" = 30'-0"C 110

SIGNING AND MARKING PLAN1

VISITOR PARKING

ACCESSIBLE PARKING

MOTORCYCLES

BUSES, TAXIS, RVs

PASSENGER PICK-UP

AND DROP-OFF

PICNIC AREA

R5-1a

PROPOSED

R4-7

PROPOSED

EXISTING TO REMAIN

EXISTING PROPOSED

LARGE VEHICLES

STAY RIGHT FOR

LANES 1 AND 2

PROPOSED

TYPE B, CLASS 1, WHITE 12" WIDTH

TYPE B, CLASS 1, WHITE, 24" WIDTH

TYPE B, CLASS 1, WHITE, ACCESSIBLE PARKING

SPACE SYMBOL

E

F

1:30

30150 756045

SHEET NO.

GRAPHIC SCALE(S)

KEY PLAN

BUILDING NAME

DATE

REVISION 1

REVISION

SUBMISSION

REVISION 2

REVISION 3

REVISION 4

REVISION 5

REVISION 6

REVISION

SEQUENCETYPEDISCIPLINE

CHECKED BYDRAWN BYDESIGNED BY

WORKING STAFF

DRAWING TYPE

DRAWING TITLE

PROJECT TITLE

A/E PROJECT NUMBER

OFEO PROJECT NUMBER

ADDRESS

C

11400 COMMERCE PARK DR., SUITE 400, RESTON, VA 20191

PHONE: 703-674-1300 FAX: 703-674-1350

WWW.KIMLEY-HORN.COM

NASM - UDVAR-HAZY CENTER

14930 Air & Space Museum Pkwy Chantilly, Virginia 20151

Parking Entrance Control Upgrades

Office of Facilities Engineering and Operations 600 Maryland Avenue S.W. Suite 5001

Washington DC 20024-2520

M

AT

CH

LI

NE

- S

EE

TH

IS

SH

EE

T

MATCHLINE

- SEE

SHEET

C110

NORTH

M

ATC

H

LIN

E

-SEE

TH

IS

SH

EET

EX SIGN NO PARKING (R8-3)

EX SIGN DOUBLE ARROW (M6-4)

TO REMAIN

EX SIGN 'GATE 317 RIGHT LANE'

TO REMAINEX SIGN NO PARKING (R8-3)

EX SIGN DOUBLE ARROW (M6-4)

TO REMAIN

EX SIGN AUTHORIZED VEHICLES ONLY (R5-11)

TO REMAINEX STOP SIGN (R1-1)

TO REMAIN

EX SIGN KEEP RIGHT (R4-7)

TO REMAIN

EX SIGN 'GATE 317 (ARROW)

OFFICIAL AIRPORT

BUSINESS ONLY

NEXT RIGHT'

TO REMAIN

EX SIGN NO PARKING (R8-3)

EX SIGN DOUBLE ARROW (M6-4)

TO REMAIN

EX SIGN RIGHT LANE MUST TURN RIGHT (R3-7R)

TO REMAIN

EX SIGN 'GATE 317 (ARROW)

OFFICIAL AIRPORT

BUSINESS ONLY

CLOSED 1730-0530 HOURS'

TO REMAIN

EX SIGN KEEP RIGHT (R4-7)

TO REMAIN

EX STOP SIGN (R1-1)

TO REMAIN

EX SIGN

NO PARKING (R8-3)

EX SIGN

DOUBLE ARROW (M6-4)

TO REMAIN

EX SIGN NO PARKING (R8-3)

EX SIGN DOUBLE ARROW (M6-4)

TO REMAIN 3

SIGN LEGEND

ALL PARKING

AND DELIVERIES

ACCESSIBLE

BUSES, TAXIS, RVs

SHUTTLES

Smithsonian Inst itut ion

STEVEN F. UDVAR-HAZY CENTER

VISITOR PARKING

FOR INFORMATION

WEAPONS PROHIBITED

$15.OO per car

TUNE TO AM 1660

VISITOR PARKING

BUSES, TAXIS, RVs

LANES 1-4

TUNE TO AM 1660 FOR INFORMATION

3 4l

$15 PER VEHICLE

SHUTTLES

LANE 5

1. ALL PROPOSED SIGNING AND PAVEMENT MARKINGS SHALL BE IN ACCORDANCE WITH THE MOST

CURRENT EDITION OF EACH OF THE FOLLOWING MANUALS, OR THE MOST RECENT REVISION

THERETO:

A. MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD)

B. THE VIRGINIA SUPPLEMENT TO THE MUTCD

C. THE VIRGINIA DEPARTMENT OF TRANSPORTATION ROAD AND BRIDGE

SPECIFICATIONS

D. THE VIRGINIA DEPARTMENT OF TRANSPORTATION ROAD AND BRIDGE STANDARDS

2. ALL PAVEMENT MARKINGS SHALL BE TYPE B, CLASS 1, UNLESS OTHERWISE NOTED.

3. PROPOSED SIGN LOCATIONS ARE APPROXIMATE AND SHALL BE MODIFIED IN THE FIELD TO AVOID

CONFLICT WITH UNDERGROUND UTILITIES OR OTHER OBSTRUCTIONS, AND TO COMPLY WITH

STANDARDS REFERENCED IN NOTE 1 ABOVE.

4. ANY EXISTING PAVEMENT MARKINGS THAT WILL CONFLICT WITH PROPOSED PAVEMENT MARKINGS

SHALL BE COMPLETELY ERADICATED.

5. LIMITS SHOWN OF PROPOSED MARKINGS ARE APPROXIMATE AND SHALL BE MODIFIED IN THE FIELD

TO ENSURE THAT PROPOSED PAVEMENT MARKINGS CONTINUE UNTIL EXISTING PAVEMENT

MARKINGS CAN BE MATCHED.

6. ALL NEW SIGNS SHALL BE PLACED ON VDOT STP-1 POST(S).

7. ALL SIGNS WITHIN THE CLEAR ZONE SHALL BE INSTALLED ON A BREAKAWAY SUPPORT.

SIGNING AND PAVEMENT MARKING NOTES

M

AT

C

H

EX

ST

R

IP

IN

G

M

AT

C H

EX

ST

R

IP

IN

G

C

B

D

C

TYPE B, CLASS 1, YELLOW, 4" WIDTH

TYPE B, CLASS 1, WHITE, 4" WIDTH

TYPE B, CLASS 1, WHITE, 4" WIDTH, 10' LONG, 30' SPACE

TYPE B, CLASS 1, WHITE 4" WIDTH, 2' LONG, 4' SPACE

TYPE B, CLASS 1, WHITE 12" WIDTH

TYPE B, CLASS 1, WHITE, 24" WIDTH

TYPE B, CLASS 1, WHITE, ACCESSIBLE PARKING SPACE SYMBOL

PAVEMENT MARKING LEGEND

A

B

C

D

E

F

A

VISITOR PARKING

FOR INFORMATION

WEAPONS PROHIBITED

TUNE TO AM 1660

VISITOR PARKING

BUSES, TAXIS, RVs

TUNE TO AM 1660 FOR INFORMATION

SHUTTLES

LANE 7

5 74 6

SIGNING AND MARKING PLAN

11/21/2014

KB JA RJM

11113 OF 33

110408000 1354510

Civil

1" = 30'-0"C 111

SIGNING AND MARKING PLAN1

DMS (1 LINE) DMS (1 LINE)

EXISTING EXISTING TO REMAINEXISTING EXISTING

PROPOSED PROPOSED PROPOSED

VISITOR PARKING

BUSES, TAXIS, RVs

TUNE TO AM 1660 FOR INFORMATION

3 4l

$15 PER VEHICLE

SHUTTLES

VISITOR PARKING

BUSES, TAXIS, RVs

TUNE TO AM 1660 FOR INFORMATION

SHUTTLES

5 74 6

DMS

(2 LINES)

DMS (1 LINE)

DMS

(2 LINES)

KEY PLAN

BUILDING NAME

DATE

REVISION 1

REVISION

SUBMISSION

REVISION 2

REVISION 3

REVISION 4

REVISION 5

REVISION 6

REVISION

SEQUENCETYPEDISCIPLINE

CHECKED BYDRAWN BYDESIGNED BY

WORKING STAFF

DRAWING TYPE

DRAWING TITLE

PROJECT TITLE

A/E PROJECT NUMBER

OFEO PROJECT NUMBER

ADDRESS

C

11400 COMMERCE PARK DR., SUITE 400, RESTON, VA 20191

PHONE: 703-674-1300 FAX: 703-674-1350

WWW.KIMLEY-HORN.COM

NASM - UDVAR-HAZY CENTER

14930 Air & Space Museum Pkwy Chantilly, Virginia 20151

Parking Entrance Control Upgrades

Office of Facilities Engineering and Operations 600 Maryland Avenue S.W. Suite 5001

Washington DC 20024-2520

11/21/2014

KB JA RJM

Civil

110408000 1354510

12114 OF 33

1. UNLESS OTHERWISE APPROVED OR DIRECTION BY THE SMITHSONIAN, THE CONTRACTOR SHALL PLAN AND PROSECUTE THE WORK IN ACCORDANCE WITH THE FOLLOWING SEQUENCE AND MAINTENANCE OF TRAFFIC PLAN. IT IS NOT THE INTENT OF THIS SEQUENCE OF CONSTRUCTION PLAN TO ENUMERATE EVERY DETAIL WHICH MUST BE CONSIDERED IN THE CONSTRUCTION OF EACH PHASE, BUT ONLY TO

SUMMARIZE GENERAL TRAFFIC MANAGEMENT AND MAJOR CONSTRUCTION ITEM SEQUENCING.

2. ALL STANDARDS AND GUIDELINES OF THE VIRGINIA WORK AREA PROTECTION MANUAL, DATED AUGUST 2011 (INCLUDING ALL REVISIONS) SHALL APPLY TO THESE TRAFFIC CONTROL PLANS. WHILE THESE TRAFFIC CONTROL PLANS AND THE 2011 WORK AREA PROTECTION MANUAL PROVIDE GUIDELINES FOR THE DESIGN AND APPLICATION OF TRAFFIC CONTROL DEVICES, THEY ARE NO SUBSTITUTE FOR

ENGINEERING JUDGEMENT.

3. ALL WORK AREAS (AND THE LIMITS THEREOF) AND LANE CLOSURES SHALL BE IN ACCORDANCE WITH THE VIRGINIA WORK AREA PROTECTION MANUAL, DATED AUGUST 2011 (INCLUDING ALL REVISIONS), AND

SHALL BE DIRECTED OR APPROVED BY THE ENGINEER OR SMITHSONIAN.

4. IT IS THE CONTRACTOR'S RESPONSIBILITY TO MAINTAIN SATISFACTORY DRAINAGE THROUGHOUT THE

CONSTRUCTION OF THIS PROJECT.

5. THE CONTRACTOR SHALL NOT CONDUCT REPAIR OPERATIONS WHEN THE WEATHER CAUSES UNSAFE CONDITIONS FOR THE TRAVELING PUBLIC AS DETERMINED BY THE ENGINEER OR SMITHSONIAN.

6. TRAFFIC CONTROL DEVICES SHALL BE KEPT CLEAN, LEGIBLE, AND IN PROPER WORKING ORDER AT ALL TIMES. THE CONTRACTOR SHALL PROVIDE A PERSON WHOSE RESPONSIBILITY SHALL BE TO INSPECT AND MAINTAIN SIGNS, BARRICADES, OTHER CHANNELIZING DEVICES, AND LIGHTS DURING THE TIME THAT

TRAFFIC IS RESTRICTED DUE TO CONSTRUCTION OPERATIONS.

7. ANY CONTRACT ITEMS NOT SPECIFICALLY NOTED IN THE SEQUENCE OF CONSTRUCTION MAY BE

CONSTRUCTED AT THE CONVENIENCE OF THE CONTRACTOR AS DIRECTED BY THE ENGINEER OR

SMITHSONIAN.

8. ALL CONSTRUCTION AND CONSTRUCTION EQUIPMENT SHALL BE MAINTAINED WITHIN THE

CONSTRUCTION WORK ZONE.

9. ALL CONSTRUCTION SIGNING AND PAVEMENT MARKINGS SHALL BE IN ACCORDANCE WITH THE MUTCD

AND THE VIRGINIA SUPPLEMENT TO THE MUTCD STANDARDS.

10. CONTRACTOR SHALL SUBMIT A MAINTENANCE OF TRAFFIC PLAN FOR EACH PHASE TO THE ENGINEER

AND SMITHSONIAN FOR REVIEW AND APPROVAL PRIOR TO START OF CONSTRUCTION.

11. CONTRACTOR SHALL CONTACT THE PROJECT ENGINEER IN WRITING WITH A WORK SCHEDULE 2-WEEKS

BEFORE STARTING WORK.

12. ALL WORK WITHIN 30 FEET OF THE OUTSIDE EDGE OF PAVEMENT SHALL BE SIGNED. UNDER NO CIRCUMSTANCES WILL CONCURRENT WORK LEFT AND RIGHT OF ANY LANE OF TRAFFIC BE ALLOWED.

13. FOR NIGHT WORK, FLOODLIGHTS SHALL BE USED WHERE EXISTING LIGHT IS NOT ADEQUATE TO

PERFORM THE WORK SAFELY. IN NO CASE SHALL FLOODLIGHTING BE PERMITTED TO CREATE A

DISABLING GLARE FOR DRIVERS.

14. FAILURE TO PROVIDE TEMPORARY TRAFFIC CONTROL IN ACCORDANCE WITH THE VIRGINIA WORK AREA PROTECTION MANUAL AND THE PLANS, SPECIFICATIONS, AND SPECIFICATIONS SHALL RESULT IN

IMMEDIATE CORRECTIVE MEASURES BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE

SMITHSONIAN.

15. PROVIDE ADVANCE WARNING SIGNS PER THE VIRGINIA WORK AREA PROTECTION MANUAL FIGURE

TTC-53.0. SEE FIGURE ON THIS SHEET.

16. THE EXISTING PAY-ON-ENTRANCE OPERATIONS MUST REMAIN IN EFFECT UNTIL PHASE 3. THE

CONTRACTOR SHALL RECEIVE APPROVAL FROM THE SMITHSONIAN AND THE ENGINEER PRIOR TO

INITIATING THE NEW PAY-ON-EXIT SYSTEM.

17. CHANNELIZATION DEVICE SPACING SHALL BE 40' WHERE PARALLEL TO THE TRAVELWAY AND 20' IN

TAPERS AND CURVES PER THE VIRGINIA WORK AREA PROTECTION MANUAL.

18. IT IS THE CONTRACTOR'S RESPONSIBILITY TO MAINTAIN ACCESS FOR LARGE VEHICLES TO AND FROM THE MUSEUM. ADDITIONAL SIGNAGE SHALL BE PROVIDED TO GUIDE DRIVERS THROUGH THE GATES

DURING CONSTRUCTION.

GENERAL NOTES FOR ALL PHASES OF CONSTRUCTION

NOT TO SCALEC 112

MAINTENANCE OF TRAFFIC NOTES AND DETAILS1

MAINTENANCE OF TRAFFIC

NOTES AND DETAILS

11/21/2014

KB JA RJM

Civil

SHEET NO.

GRAPHIC SCALE(S)

KEY PLAN

BUILDING NAME

DATE

REVISION 1

REVISION

SUBMISSION

REVISION 2

REVISION 3

REVISION 4

REVISION 5

REVISION 6

REVISION

SEQUENCETYPEDISCIPLINE

CHECKED BYDRAWN BYDESIGNED BY

WORKING STAFF

DRAWING TYPE

DRAWING TITLE

PROJECT TITLE

A/E PROJECT NUMBER

OFEO PROJECT NUMBER

ADDRESS

C

11400 COMMERCE PARK DR., SUITE 400, RESTON, VA 20191

PHONE: 703-674-1300 FAX: 703-674-1350

WWW.KIMLEY-HORN.COM

NASM - UDVAR-HAZY CENTER

14930 Air & Space Museum Pkwy Chantilly, Virginia 20151

Parking Entrance Control Upgrades

Office of Facilities Engineering and Operations 600 Maryland Avenue S.W. Suite 5001

Washington DC 20024-2520

110408000 1354510

13115 OF 33

NOT TO SCALEC 113

MAINTENANCE OF TRAFFIC DETAILS1

MAINTENANCE OF TRAFFIC

DETAILS

1:30

30150 756045

SHEET NO.

GRAPHIC SCALE(S)

KEY PLAN

BUILDING NAME

DATE

REVISION 1

REVISION

SUBMISSION

REVISION 2

REVISION 3

REVISION 4

REVISION 5

REVISION 6

REVISION

SEQUENCETYPEDISCIPLINE

CHECKED BYDRAWN BYDESIGNED BY

WORKING STAFF

DRAWING TYPE

DRAWING TITLE

PROJECT TITLE

A/E PROJECT NUMBER

OFEO PROJECT NUMBER

ADDRESS

C

11400 COMMERCE PARK DR., SUITE 400, RESTON, VA 20191

PHONE: 703-674-1300 FAX: 703-674-1350

WWW.KIMLEY-HORN.COM

NASM - UDVAR-HAZY CENTER

14930 Air & Space Museum Pkwy Chantilly, Virginia 20151

Parking Entrance Control Upgrades

Office of Facilities Engineering and Operations 600 Maryland Avenue S.W. Suite 5001

Washington DC 20024-2520

MATCHLINE

- SEE

THIS

SHEET

1. INSTALL TEMPORARY TRAFFIC CONTROL DEVICES AS REQUIRED AND GENERALLY AS SHOWN IN THE

TRAFFIC CONTROL PLAN FOR PHASE 1 ACTIVITIES.

2. CONSTRUCT NEW ENTRANCE ROAD, EMPLOYEE PARKING, NEW CONCRETE PAVEMENT, ISLAND, AND

PRCS EQUIPMENT FOR LANES 6 AND 7.

3. THE CONTRACTOR HAS THE OPTION TO INSTALL THE CASHIER BOOTH FOR LANE 5 IN PHASE 1.

4. LANES 5, 6, AND 7 ARE CLOSED DURING PHASE 1 CONSTRUCTION.

5. FOR GENERAL NOTES FOR ALL PHASES OF CONSTRUCTION SEE THE MAINTENANCE OF TRAFFIC NOTES

AND DETAILS SHEET.

PHASE 1 CONSTRUCTION GENERAL NOTES

WORK AREA

TRAFFIC SPACE

TYPE III BARRICADE

GROUP II CHANNELIZING DEVICE

TRAVEL DIRECTION

LEGEND

1" = 30'-0"C 114

MAINTENANCE OF TRAFFIC PLAN - PHASE I1

BUS LANE

BUS LANES

11/21/2014

KB JA RJM

14116 OF 33

110408000 1354510

Civil

M

ATC

H

LIN

E

-SEE

TH

IS

SH

EET

MAINTENANCE OF TRAFFIC

PLAN - PHASE I

Design-Build Requirements Documents

NORTH

NORTH

LANE 7

LANE 6

LANE 5

LANE 4

LANE 3

LANE 2

LANE 1

1:30

30150 756045

SHEET NO.

GRAPHIC SCALE(S)

KEY PLAN

BUILDING NAME

DATE

REVISION 1

REVISION

SUBMISSION

REVISION 2

REVISION 3

REVISION 4

REVISION 5

REVISION 6

REVISION

SEQUENCETYPEDISCIPLINE

CHECKED BYDRAWN BYDESIGNED BY

WORKING STAFF

DRAWING TYPE

DRAWING TITLE

PROJECT TITLE

A/E PROJECT NUMBER

OFEO PROJECT NUMBER

ADDRESS

C

11400 COMMERCE PARK DR., SUITE 400, RESTON, VA 20191

PHONE: 703-674-1300 FAX: 703-674-1350

WWW.KIMLEY-HORN.COM

NASM - UDVAR-HAZY CENTER

14930 Air & Space Museum Pkwy Chantilly, Virginia 20151

Parking Entrance Control Upgrades

Office of Facilities Engineering and Operations 600 Maryland Avenue S.W. Suite 5001

Washington DC 20024-2520

MATCHLINE

- SEE

THIS

SHEET

WORK AREA

TRAFFIC SPACE

TYPE III BARRICADE

GROUP II CHANNELIZING DEVICE

TRAVEL DIRECTION

LEGEND

1. INSTALL TEMPORARY TRAFFIC CONTROL DEVICES AS REQUIRED AND GENERALLY AS SHOWN IN THE

TRAFFIC CONTROL PLAN FOR PHASE 2 ACTIVITIES.

2. CONSTRUCT NEW CONCRETE PAVEMENT, ISLANDS, MEDIAN, AND PRCS EQUIPMENT FOR LANES 2 - 5.

3. REMOVE EXISTING MEDIANS.

4. LANES 2 - 5 CLOSED DURING PHASE 2 CONSTRUCTION. THE CONTRACTOR SHALL MERGE THE ENTRANCE

AND EXIT TRAVEL LANES DOWN TO ONE LANE AS SHOWN ON PLAN.

5. PROVIDE INSIDE LANE CLOSURE PER VIRGINIA WORK AREA PROTECTION MANUAL FIGURE TTC-17.0. SEE

MAINTENANCE OF TRAFFIC NOTES AND DETAILS SHEET.

6. FOR GENERAL NOTES FOR ALL PHASES OF CONSTRUCTION SEE THE MAINTENANCE OF TRAFFIC NOTES

AND DETAILS SHEET.

PHASE 2 CONSTRUCTION GENERAL NOTES

BUS LANE

MAINTENANCE OF TRAFFIC

PLAN - PHASE II

11/21/2014

KB JA RJM

15117 OF 33

110408000 1354510

Civil

1" = 30'-0"C 115

MAINTENANCE OF TRAFFIC PLAN - PHASE II1

M

ATC

H

LIN

E

-SEE

TH

IS

SH

EET

Design-Build Requirements Documents

NORTH

NORTH

LANE 7

LANE 6

LANE 5

LANE 4

LANE 3

LANE 2

BUS LANE

1:30

30150 756045

SHEET NO.

GRAPHIC SCALE(S)

KEY PLAN

BUILDING NAME

DATE

REVISION 1

REVISION

SUBMISSION

REVISION 2

REVISION 3

REVISION 4

REVISION 5

REVISION 6

REVISION

SEQUENCETYPEDISCIPLINE

CHECKED BYDRAWN BYDESIGNED BY

WORKING STAFF

DRAWING TYPE

DRAWING TITLE

PROJECT TITLE

A/E PROJECT NUMBER

OFEO PROJECT NUMBER

ADDRESS

C

11400 COMMERCE PARK DR., SUITE 400, RESTON, VA 20191

PHONE: 703-674-1300 FAX: 703-674-1350

WWW.KIMLEY-HORN.COM

NASM - UDVAR-HAZY CENTER

14930 Air & Space Museum Pkwy Chantilly, Virginia 20151

Parking Entrance Control Upgrades

Office of Facilities Engineering and Operations 600 Maryland Avenue S.W. Suite 5001

Washington DC 20024-2520

MATCHLINE

- SEE

THIS

SHEET

M

ATC

H

LIN

E

-SEE

TH

IS

SH

EET

NORTH

WORK AREA

TRAFFIC SPACE

TYPE III BARRICADE

GROUP II CHANNELIZING DEVICE

TRAVEL DIRECTION

LEGEND

1" = 30'-0"C 116

MAINTENANCE OF TRAFFIC PLAN - PHASE III1

1. INSTALL TEMPORARY TRAFFIC CONTROL DEVICES AS REQUIRED AND GENERALLY AS SHOWN IN THE

TRAFFIC CONTROL PLAN FOR PHASE 3 ACTIVITIES.

2. CONSTRUCT NEW CONCRETE PAVEMENT, ISLAND, PRCS EQUIPMENT FOR LANE 1, AND INSTALL THE BIO

FILTER.

3. REMOVE EXISTING EMPLOYEE PARKING.

4. LANES 1 AND 2 ARE CLOSED DURING PHASE 3 CONSTRUCTION. USE LANES 3 - 5 AS EXIT LANES.

5. CONTRACTOR SHALL PERFORM FINAL PAVEMENT OVERLAY, INSTALL SIGNS AND PAVEMENT MARKINGS, PLACE PAY-ON-EXIT SYSTEM INTO SERVICE, AND DISMANTLE WORK ZONE.

6. FOR GENERAL NOTES FOR ALL PHASES OF CONSTRUCTION SEE THE MAINTENANCE OF TRAFFIC NOTES

AND DETAILS SHEET.

PHASE 3 CONSTRUCTION GENERAL NOTES

BUS LANE

BUS LANE

11/21/2014

KB JA RJM

16118 OF 33

110408000 1354510

Civil

MAINTENANCE OF TRAFFIC

PLAN - PHASE III

NORTH

Design-Build Requirements Documents

LANE 7

LANE 6

LANE 5

LANE 4

LANE 3

LANE 2

GRAPHIC SCALE(S)

KEY PLAN

BUILDING NAME

DATE

REVISION 1

REVISION

SUBMISSION

REVISION 2

REVISION 3

REVISION 4

REVISION 5

REVISION 6

REVISION

SEQUENCETYPEDISCIPLINE

CHECKED BYDRAWN BYDESIGNED BY

WORKING STAFF

DRAWING TYPE

DRAWING TITLE

PROJECT TITLE

A/E PROJECT NUMBER

OFEO PROJECT NUMBER

ADDRESS

C

11400 COMMERCE PARK DR., SUITE 400, RESTON, VA 20191

PHONE: 703-674-1300 FAX: 703-674-1350

WWW.KIMLEY-HORN.COM

1:10

1050 252015

NASM - UDVAR-HAZY CENTER

14930 Air & Space Museum Pkwy Chantilly, Virginia 20151

Parking Entrance Control Upgrades

Office of Facilities Engineering and Operations 600 Maryland Avenue S.W. Suite 5001

Washington DC 20024-2520

NOTES

1. THE BASEMAP FOR THIS DETAIL UTILIZED

SHEET AB-E-1-2-01 AND AB-E-1-2-02 OF M.C.

DEANS AS-BUILT

2. CONTRACTOR SHALL COORDINATE WITH NASM

FOR FINAL LOCATION OF PAY-ON-FOOT DEVICE

LOCATIONS

PAY-ON-FOOT STATION PLAN

11/21/2014

KB JA RJM

19119 OF 33

110408000 1354510

Civil

1" = 10'-0"C 119

PAY-ON-FOOT STATION PLAN1

N O

R

TH

KEY PLAN

BUILDING NAME

DATE

REVISION 1

REVISION

SUBMISSION

REVISION 2

REVISION 3

REVISION 4

REVISION 5

REVISION 6

REVISION

SEQUENCETYPEDISCIPLINE

CHECKED BYDRAWN BYDESIGNED BY

WORKING STAFF

DRAWING TYPE

DRAWING TITLE

PROJECT TITLE

A/E PROJECT NUMBER

OFEO PROJECT NUMBER

ADDRESS

C

11400 COMMERCE PARK DR., SUITE 400, RESTON, VA 20191

PHONE: 703-674-1300 FAX: 703-674-1350

WWW.KIMLEY-HORN.COM

NASM - UDVAR-HAZY CENTER

14930 Air & Space Museum Pkwy Chantilly, Virginia 20151

Parking Entrance Control Upgrades

Office of Facilities Engineering and Operations 600 Maryland Avenue S.W. Suite 5001

Washington DC 20024-2520

CONSTRUCTION DETAILS

11/21/2014

KB JA RJM

01520 OF 33

110408000 1354510

Civil

1" = 30'-0"C 501

CONSTRUCTION DETAILS1

KEY PLAN

BUILDING NAME

DATE

REVISION 1

REVISION

SUBMISSION

REVISION 2

REVISION 3

REVISION 4

REVISION 5

REVISION 6

REVISION

SEQUENCETYPEDISCIPLINE

CHECKED BYDRAWN BYDESIGNED BY

WORKING STAFF

DRAWING TYPE

DRAWING TITLE

PROJECT TITLE

A/E PROJECT NUMBER

OFEO PROJECT NUMBER

ADDRESS

C

11400 COMMERCE PARK DR., SUITE 400, RESTON, VA 20191

PHONE: 703-674-1300 FAX: 703-674-1350

WWW.KIMLEY-HORN.COM

NASM - UDVAR-HAZY CENTER

14930 Air & Space Museum Pkwy Chantilly, Virginia 20151

Parking Entrance Control Upgrades

Office of Facilities Engineering and Operations 600 Maryland Avenue S.W. Suite 5001

Washington DC 20024-2520

TYPICAL LANE LAYOUTS

11/21/2014

KB JA RJM

02521 OF 33

110408000 1354510

Design-Build Requirements Documents

Civil

NOT TO SCALEC 502

TYPICAL ENTRY LANE LAYOUT1

NOT TO SCALEC 502

TYPICAL EXIT LANE LAYOUT2

NOT TO SCALEC 502

TYPICAL REVERSIBLE LANE LAYOUT3

NOT TO SCALEC 502

TYPICAL SECTION A-A4

NOT TO SCALEC 502

TYPICAL SECTION B-B5

KEY PLAN

BUILDING NAME

DATE

REVISION 1

REVISION

SUBMISSION

REVISION 2

REVISION 3

REVISION 4

REVISION 5

REVISION 6

REVISION

SEQUENCETYPEDISCIPLINE

CHECKED BYDRAWN BYDESIGNED BY

WORKING STAFF

DRAWING TYPE

DRAWING TITLE

PROJECT TITLE

A/E PROJECT NUMBER

OFEO PROJECT NUMBER

ADDRESS

C

11400 COMMERCE PARK DR., SUITE 400, RESTON, VA 20191

PHONE: 703-674-1300 FAX: 703-674-1350

WWW.KIMLEY-HORN.COM

NASM - UDVAR-HAZY CENTER

14930 Air & Space Museum Pkwy Chantilly, Virginia 20151

Parking Entrance Control Upgrades

Office of Facilities Engineering and Operations 600 Maryland Avenue S.W. Suite 5001

Washington DC 20024-2520

CASHIER STATION DETAILS

11/21/2014

KB JA RJM

03522 OF 33

110408000 1354510

Civil

1" = 30'-0"C 503

CASHIER STATION DETAILS1

1:30

30150 756045

SHEET NO.

GRAPHIC SCALE(S)

KEY PLAN

BUILDING NAME

DATE

REVISION 1

REVISION

SUBMISSION

REVISION 2

REVISION 3

REVISION 4

REVISION 5

REVISION 6

REVISION

SEQUENCETYPEDISCIPLINE

CHECKED BYDRAWN BYDESIGNED BY

WORKING STAFF

DRAWING TYPE

DRAWING TITLE

PROJECT TITLE

A/E PROJECT NUMBER

OFEO PROJECT NUMBER

ADDRESS

E

11400 COMMERCE PARK DR., SUITE 400, RESTON, VA 20191

PHONE: 703-674-1300 FAX: 703-674-1350

WWW.KIMLEY-HORN.COM

NASM - UDVAR-HAZY CENTER

14930 Air & Space Museum Pkwy Chantilly, Virginia 20151

Parking Entrance Control Upgrades

Office of Facilities Engineering and Operations 600 Maryland Avenue S.W. Suite 5001

Washington DC 20024-2520

LEGEND

GENERAL NOTES

1. THE BASEMAP FOR THIS DETAIL UTILIZED THE

ELECTRONIC DRAWING FILE FROM THE

UDVAR-HAZY PACKAGE B LIGHTING PLAN

PROVIDE BY THE SMITHSONIAN INSTITUTION.

ELECTRIC VEHICLE CHARGING

STATIONS PLAN

11/21/2014

JS BL JC

01123 OF 33

110408000 1354510

ELECTRICAL

1" = 10'-0"E 101

EVC STATIONS DETAIL2

Design-Build Requirements Documents

NORTH

NORTH

1" = 30'-0"E 101

ELECTRIC VEHICLE CHARGING STATIONS PLAN1

DUAL ELECTRIC VEHICLE CHARGING STATION

(LEVEL 2) PEDESTAL

ELECTICAL CONDUIT (SIZE, QUALITY, AND

TYPE AS NOTED)

SHEET NOTES

EXISTING PANEL 511D3 IN ELECTRICAL ROOM

104.06. USE EXISTING SPARE 225 A CIRCUIT

BREAKER FOR EV CHARGERS.

USE EXISTING 4" CONDUITS 18 AND 19 (FROM MC

DEAN ASBUILTS) FOR PATH TO EXISTING MANHOLE

#10. CONDUIT 19 TO BE SPARE.

(5) 2" RGS CONDUITS

(2) 3" RGS CONDUITS

(1) 4" RGS CONDUIT

(1) 2" PVC SCHEDULE 40 CONDUIT TO EV CHARGING

PEDESTAL. TYPICAL FOR CONDUIT PATH TO ALL

CHARGERS.

(2) 4" PVC SCHEDULE 40 CONDUIT. 1 0F THE 2

CONDUITS SHALL BE SPARE WITH PULL ROPE.

(2) 4" HDPE SDR 11 CONDUITS. 1 OF THE 2

CONDUITS SHALL BE SPARE WITH PULL ROPE.

(1) 1" PVC SCHEDULE 40 CONDUIT TO EV CHARGER

FOR COMMUNICATION. TYPICAL FOR

COMMUNICATION CONDUIT PATH TO ALL

CHARGERS.

(1) 3" RGS CONDUIT

(1) 2" RGS CONDUIT

COMMUNICATIONS CABINET WITH RUGGEDIZED

SWITCH AND CELLULAR MODEM.

CG-12 TYPE B

PAINTED CROSSWALK AND LOADING ZONE

FUTURE DUAL ELECTRIC VEHICLE CHARGING

STATION (LEVEL 2) PEDESTAL

ELECTICAL CONDUIT (SIZE, QUALITY, AND

TYPE AS NOTED) FOR FUTURE EV CHARGERS

FUSED DISCONNECT

150KVA TRANSFORMER

MAIN CIRCUIT BREAKER PANEL

ELECTRICAL JUNCTION BOX

EXISTING CONDUIT

BOLLARD FOR EV CHARGERS

BOLLARD FOR FUTURE EV CHARGERS

EXISTING UNDERGROUND ELECTRICAL CONDUIT

FOR LIGHTING

COMMUNICATIONS CABINET

COMMUNICATIONS CONDUIT (SIZE, QUALITY,

AND TYPE AS NOTED)

COMMUNICATIONS JUNCTION BOX

COMMUNICATIONS CONDUIT (SIZE, QUALITY,

AND TYPE AS NOTED) FOR FUTURE EV

CHARGERS

MU

ES

UM

EC

APS

DNARIA

LANOI

T A

N

DULLES CENTER

STEVEN F. UDVAR-HAZY CENTER

14585 Avion Parkway, Suite 150 Chantilly, Virginia 20151 www.PEGroup-Inc.com

703-488-9990 fax: 703-488-9994

KEY PLAN

GRAPHIC SCALE(S)

SEQUENCETYPEDISCIPLINE

CHECKED BYDRAWN BYDESIGNED BY

WORKING STAFF

DRAWING TYPE

DRAWING TITLE

PROJECT TITLE

A/E PROJECT NO.

ADDRESS

BUILDING NAME

SHEET NO.

OFEO PROJECT NUMBER

OF

Smithsonian Institution

Office of Facilities Engineering and Operations 600 Maryland Avenue S.W. Suite 5001

Washington DC 20024-2520

DATE

REVISION 1

REVISION

SUBMISSION

REVISION 2

REVISION 3

REVISION 4

REVISION 5

REVISION 6

REVISION 7

REVISION

11400 COMMERCE PARK DR., SUITE 400, RESTON, VA 20191

PHONE: 703-674-1300 FAX: 703-674-1350

WWW.KIMLEY-HORN.COM

SC

AL

E : 1

:1

Parking Entrance Control Upgrades

GENERAL NOTES, SYMBOLS

AND ABBREVIATIONS

NASM - UDVAR HAZY CENTER

14930 Air & Space Museum Pkwy Chantilly, Virginia 20151

1354510 110408000

SK MM RH

SC 0 01

11/21/2014 FINAL BRIDGING DOCUMENTS

SYMBOL LEGEND

FIXED DOME CAMERA

PTZ DOME CAMERA - POLE MOUNTED

WALL FIELD (SECURITY PANEL

LOCATION)

CARD READER

AUDIO INTERCOM

DURESS BUTTON

UNDERGROUND CONDUIT

ABBREVIATIONS

AFF ABOVE FINISHED FLOOR

AV AUDIO VISUAL

BCT BONDING CONDUCTOR FOR TELECOMMUNICATIONS

C CONDUIT

CAT CATEGORY

CATV COMMUNITY ANTENNA TELEVISION

CM CEILING MOUNTED

CT CABLE TRAY

EF ENTRANCE FACILITY

EMI ELECTRICAL MAGNETIC INTERFERANCE

EMT ELECTRICAL METALLIC TUBING

ER EQUIPMENT ROOM

FO FIBER OPTIC

IMT INTERMEDIATE METALLIC TUBING

ITS INFORMATION TECHNOLOGY SYSTEMS

LAN LOCAL AREA NETWORK

MAX MAXIMUM

MIN MINIMUM

MM MULTIMODE

MTD MOUNTED

NTS NOT TO SCALE

OC ON CENTER

OPE OWNER PROVIDED EQUIPMET

PP PATCH PANEL

PR PAIR

PTZ PAN-TILT-ZOOM CAMERA

RM ROOM

RMU RACK MOUNTING UNIT (1.75")

SM SINGLEMODE

SP SERVICE PROVIDER

STP SHIELDED TWISTED PAIR

TBB TELECOMMUNICATIONS BONDING BACKBONE

TBD TO BE DETERMINED

TYP TYPICAL

UON UNLESS OTHERWISE NOTED

UPS UNINTERRUPTED POWER SUPPLY

UTP UNSHIELDED TWISTED PAIR

VAC VOLTS ALTERNATING CURRENT

VDC VOLTS DIRECT CURRENT

VP VANDAL PROOF

WAO WORK AREA OUTLET

WM WALL MOUNTED

WPE WEATHER PROOF ENCLOSURE

A201

ELEVATION ORIENTATION

DETAIL NUMBER

DETAIL SHEET

ELEVATION AND DETAIL CALLOUT

A401

1 DETAIL NUMBER

DETAIL SHEET

A401A401

DETAIL NUMBER

DETAIL SHEET

REFERENCING SHEET

AIC

DI

GENERAL NOTES

1. THE SCOPE OF THIS PROJECT INCLUDES DESIGNING AND PROVIDING A NEW

COMPLETELY SUPERVISED ELECTRONIC SECURITY SYSTEM (ESS) CONSISTING OF

ACCESS CONTROL, INTRUSION DETECTION AND CLOSED CIRCUIT SURVEILLANCE

SYSTEM AS SHOWN ON THE DRAWINGS AND DESCRIBED WITHIN SPECIFICATIONS FOR

THE FACILITY IDENTIFIED. THE SYSTEM SHALL INCLUDE ALL WIRING, RACEWAYS, PULL

BOXES, TERMINAL CABINETS, OUTLETS AND MOUNTING BOXES, CONTROL EQUIPMENT,

INTERFACE CABINETS, SUPERVISORY SIGNALS, INTERFACE EQUIPMENT AND ALL

OTHER ACCESSORIES AND MISCELLANEOUS ITEMS INCLUDING ANY SOFTWARE OR

PROGRAMMING, TESTING FOR A COMPLETE OPERATING SYSTEM EVEN THOUGH EACH

ITEM IS NOT SPECIFICALLY MENTIONED OR DESCRIBED.

2. CONTRACTOR SHALL FIELD VERIFY AND COORDINATE ALL EXISTING CONDITIONS AND

DIMENSIONS INDICATED ON DRAWINGS PRIOR TO THE EXECUTION OF THIS CONTRACT.

THE LOCATION OF PARTITIONS IS BASED ON INFORMATION AVAILABLE AT THE TIME OF

DESIGN. THE CONTRACTOR SHALL VERIFY LOCATIONS OF ALL PARTITIONS PRIOR TO

THE BEGINNING OF WORK.

3. THE TERM "PROVIDE" MEANS FURNISH AND INSTALL, COMPLETE AND READY FOR USE.

4. THE TERM "OWNER" MEANS SMITHSONIAN NATIONAL AIR AND SPACE MUSEUM OR ITS

DESIGNATED REPRESENTATIVE OR AGENT.

5. THE TERM "CONTRACTOR" OR "GENERAL CONTRACTOR" MEANS THE PRIME

CONTRACTOR RESPONSIBLE FOR ALL WORK DEFINED IN THE SPECIFICATIONS AND

SHOWN ON THE DRAWINGS.

6. THE TERM "ELECTRICAL CONTRACTOR" MEANS A LICENSED AND QUALIFIED

SUBCONTRACTOR PERFORMING WORK FOR THE CONTRACTOR AS DEFINED IN THE

SPECIFICATIONS AND AS SHOWN ON THE DRAWINGS.

7. THE TERM "SECURITY CONTRACTOR" MEANS A SOFTWARE HOUSE SYSTEMS

CERTIFIED AND QUALIFIED SUBCONTRACTOR PERFORMING WORK FOR THE

CONTRACTOR AS DEFINED IN THE SPECIFICATIONS AND AS SHOWN ON THE

DRAWINGS.

8. THE TERM "CONTRACT DOCUMENTS" MEANS THE SPECIFICATIONS, DRAWINGS,

ADDENDUMS, SKETCHES AND OTHER DOCUMENTATION THAT DEFINE THE WORK. ALL

CONTRACT DOCUMENTS SHALL BE USED IN COMBINATION TO DEFINE THE WORK

REQUIREMENTS. VERIFY ANY CONFLICT BETWEEN DRAWINGS, TECHNICAL

SPECIFICATIONS AND SCHEDULES WITH THE CONTRACTOR PRIOR TO PERFORMANCE

OF THE WORK.

9. THE TERM "EXISTING" SHALL MEAN EXISTING TO REMAIN.

10. THE TERM "NEW" SHALL MEAN CONTRACTOR TO PROVIDE NEW.

11. THE TERM "DEMO" SHALL MEAN DEMOLISH AND REPLACE WITH NEW DEVICE UNLESS

OTHERWISE NOTED.

12. THE CONTRACT DOCUMENTS ARE DIAGRAMMATIC AND DEFINE THE GENERAL

ARRANGEMENT.

13. PROVIDE A COMPLETE AND FULLY FUNCTIONAL SECURITY SYSTEM TO INCLUDE ALL

INSTALLATION, PROGRAMMING, TESTING, COMMISSIONING AND DOCUMENTATION.

14. PROVIDE ALL LABOR, MATERIAL, EQUIPMENT, WIRE, CABLE, CONDUITS AND RACEWAYS

FOR A COMPLETE INSTALLATION.

15. CONTRACTOR SHALL TEST ALL EXISTING SECURITY DEVICES AND EQUIPMENT AND

DOCUMENT PASS/FAIL RESULTS TO VERIFY CORRECT OPERATION OF EXISTING

DEVICES TO REMAIN BEFORE THE START OF ANY CONSTRUCTION DEMO OR

INSTALLATION.

16. PROVIDE COORDINATION AND VERIFICATION OF ALL CONDITIONS INCLUDING

EQUIPMENT AND DEVICES INSTALLED BY OTHER TRADES, THE WORK OF THE

CONTRACTOR AND SUBCONTRACTORS.

17. EXTREME CARE SHALL BE EXERCISED WHEN ROUGHING IN DEVICES SO AS NOT TO

DAMAGE THE EXISTING BUILDING FINISHES.

18. PROVIDE AND MAINTAIN ALL DOCUMENTATION INCLUDING DESIGN DOCUMENTATION,

AS-BUILT DOCUMENTATION, PROGRAMMING WORKSHEETS AND PROJECT

COMMUNICATIONS.

19. FIELD VERIFY AND COORDINATE ALL DEVICE LOCATIONS. WHERE CONFLICTS OCCUR,

COORDINATE AND VERIFY FINAL LOCATIONS WITH COTR PRIOR TO INSTALLATION.

20. CONTRACTOR SHALL PAY ALL FEES AND SHALL OBTAIN ALL PERMITS AND LICENSES AS

REQUIRED TO PERFORM THE WORK DEFINED IN THE SPECIFICATIONS AND AS SHOWN

ON THE DRAWINGS.

21. PROVIDE NEW MATERIAL AND EQUIPMENT THAT CONFORM TO THE APPLICABLE

STANDARDS OF UL, NEC, NEMA, ASTM, ANSI AND OTHERS AS IDENTIFIED IN THE

TECHNICAL SPECIFICATIONS.

22. ALL WORK SHALL BE GUARANTEED FOR A MINIMUM OF ONE YEAR COMMENCING ON

THE DATE OF FINAL ACCEPTANCE OF THE SYSTEM BY THE OWNER.

23. PROVIDE LABOR, TOOLS, CONTAINERS AND SERVICES AS REQUIRED TO MAINTAIN A

CLEAN WORKSITE. REMOVE FROM THE WORK SITE ALL EXCESS MATERIAL AND

DEBRIS. CLEAN THE WORK SITE DAILY.

24. PROVIDE INTEGRATION OF SECURITY DEVICES AND EQUIPMENT WITH BUILDING FIRE

ALARM DEVICES AND EQUIPMENT TO COMPLY WITH NFPA, NEC AND CODES AND

STANDARDS.

25. FLOOR PLANS ARE TYPICAL AND SIMILAR. MINOR DISCREPANCIES WITH EXISTING

CONDITIONS EXIST, CONTRACTOR SHALL FIELD VERIFY PARTITION LOCATIONS AND

CONSTRUCTION TYPE PRIOR TO STARTING WORK.

WIRE AND CABLE NOTES

1. PROVIDE ALL WIRE AND CABLE FOR COMPLETE AND FUNCTIONAL SECURITY

SYSTEM.

2. PROVIDE WIRE AND CABLE THAT COMPLY WITH NEC AND UL REQUIREMENTS

OR COMPLY WITH LOCAL CODES AND ORDINANCES. THE MOST STRINGENT

REQUIREMENTS SHALL GOVERN.

3. WIRE AND CABLE CONDUCTORS FOR DATA CIRCUITS, CONTROL CIRCUITS AND

COMMUNICATIONS WIRING SHALL BE #22 AWG MINIMUM. UP SIZE

CONDUCTORS AS REQUIRED TO PROVIDE A MAXIMUM VOLTAGE DROP OF 10%.

4. WIRE AND CABLE CONDUCTORS FOR LOW VOLTAGE POWER DISTRIBUTION

AND CONTROL CIRCUIT WIRING SHALL BE #18 AWG MINIMUM. UP SIZE

CONDUCTORS AS REQUIRED TO PROVIDE A VOLTAGE DROP LESS THAN 10%.

5. MANUFACTURER'S INTERNAL INTERCONNECT WIRING SHALL BE UL APPROVED

AND SHALL BE SIZED IN ACCORDANCE WITH THE MANUFACTURER'S MINIMUM

REQUIREMENTS.

6. PROVIDE SHIELDED CABLE FOR ALL LOW SPEED SERIAL DATA CIRCUITS,

CONTROL CIRCUITS AND COMMUNICATIONS WIRING.

7. PROVIDE UTP CAT 5E/6 CABLE FOR ALL HIGH SPEED DATA CIRCUITS

(ETHERNET).

8. GROUND LOOPS ARE NOT PERMITTED. GROUND SHIELD DRAIN WIRES SHALL

TERMINATE TO VERIFIED EARTH GROUND TERMINAL LUGS AT THE CONTROL

CABINET OR ORIGINATING EQUIPMENT. INSULATE SHIELDS AND DRAIN WIRES

AT THE DEVICE OR REMOTE TERMINATION POINT USING UL APPROVED

INSULATORS. THE USE OF AC POWER NEUTRAL CONDUCTORS FOR GROUND

CONNECTIONS IS UNACCEPTABLE.

9. PROVIDE UNSHIELDED TWISTED PAIR CABLE ASSEMBLIES FOR ALL DC LOW

VOLTAGE POWER DISTRIBUTION AND CONTROL CIRCUITS.

10. PROVIDE SHIELDED TWISTED PAIR CABLE ASSEMBLIES FOR ALL AC LOW

VOLTAGE POWER DISTRIBUTION.

11. WIRE AND CABLE SPLICES ARE NOT PERMITTED.

12. PENETRATIONS IN MASONRY WALLS AND FLOOR/CEILING SLABS SHALL BE

CORE DRILLED WITH MASONRY TYPE CORE BIT.

13. PENETRATIONS IN FIRE RESISTIVE WALLS AND FLOOR/CEILING AND ROOF

SLABS SHALL BE PROPERLY CLEANED AND SEALED TO THE FULL THICKNESS

OF THE PENETRATION WITH A LISTED AND APPROVED FIRE STOPPING

MATERIAL OF EQUAL OR GREATER FIRE RESISTANCE THAN THE PENETRATED

ASSEMBLE. UNLESS OTHERWISE NOTED, ALL FLOOR/CEILING SLABS, STAIR

ENCLOSURES, VERTICAL SHAFT AND CHASE ENCLOSURES, MASONRY SLAB

TO SLAB, MECHANICAL, ELECTRICAL ROOM WALLS SHALL BE CONSIDERED

2-HOUR FIRE RESISTIVE RATED CONSTRUCTION AND FIRE STOPPED AS

SPECIFIED. REFER TO ARCHITECTURAL DRAWINGS FOR LOCATION AND

RATINGS OF FIRE RESISTIVE ASSEMBLIES.

14. CONCEAL ALL ELECTRICAL CONDUITS ABOVE SUSPENDED CEILINGS AND

INSIDE WALLS, EXCEPT IN UNFINISHED AREAS WHERE CONDUIT MAY BE

SURFACE MOUNTED, UNLESS OTHERWISE SPECIFIED. EXPOSED CONDUIT

SHALL BE PAINTED TO MATCH ADJACENT FINISH.

CONDUIT AND RACEWAY NOTES

1. PROVIDE CONDUITS AND RACEWAYS FOR A COMPLETE INSTALLATION. ALL

SECURITY WIRE AND CABLE SHALL BE ROUTED IN METALLIC CONDUITS, OR

CLOSED WIRE TROUGHS.

2. PROVIDE CONDUITS THAT COMPLY WITH NEC REQUIREMENTS OR COMPLY

WITH LOCAL CODES AND ORDINANCES. THE MOST STRINGENT

REQUIREMENTS SHALL GOVERN.

3. REGARDLESS OF NEC OR LOCAL CODES AND ORDINANCES, PROVIDE

CONDUIT AND RACEWAY SIZED FOR A MAXIMUM FILL OF 40%.

4. REGARDLESS OF NEC OR LOCAL CODES AND CONDUIT FILL REQUIREMENTS,

CONDUIT SHALL BE 19mm [3/4"] MINIMUM DIAMETER.

5. PROVIDE COMPRESSION TYPE CONDUIT FITTINGS. SET SCREW TYPE

FITTINGS ARE NOT ACCEPTABLE.

6. PROVIDE OWNER APPROVED SECURITY SCREWS AND FASTENERS FOR ALL

SECURITY JUNCTION BOXES AND SCREW COVER ENCLOSURES.

7. PROVIDE COLOR CODING OF ALL SECURITY CONDUITS. ALL JUNCTION

BOXES, DEVICE BOXES, TERMINAL CABINETS AND WIRE TROUGH COVERS

SHALL BE PAINTED. COLOR TO BE BENJAMIN MOORE #791 OR APPROVED

EQUAL.

8. CONCEAL CONDUIT AND RACEWAYS TO THE EXTENT POSSIBLE. WHERE

CONDUITS AND RACEWAYS CANNOT BE CONCEALED, COORDINATE WITH

THE COTR TO OBTAIN APPROVAL PRIOR TO INSTALLATION.

9. PROVIDE SEPARATE RACEWAY, CONDUITS, JUNCTION BOXES AND

ENCLOSURES FOR ALL SECURITY WIRE AND CABLE. DO NOT COMBINE

120VAC OR ANY POWER DISTRIBUTION CIRCUIT WITH SECURITY WIRE AND

CABLE.

10. PROVIDE ACCESS COVERS OR HATCHES FOR ALL SECURITY JUNCTION

BOXES CONCEALED IN STRUCTURE. PROVIDE ACCESS TO JUNCTION BOXES

AND EQUIPMENT ENCLOSURES LOCATED WITHIN 3m OF SECURITY DEVICES.

REMOVAL NOTES

1. PRIOR TO INITIATING ANY REMOVAL WORK THE CONTRACTOR SHALL

PERFORM A "FUNCTIONAL CHECK" OF ALL ESS EQUIPMENT

INCLUDING BUT NOT LIMITED TO: ACCESS CONTROL PANELS,

READER INTERFACE MODULES, VIDEO SURVEILLANCE CAMERAS,

CARD READERS, ELECTRIFIED LOCKS, ELECTROMAGNETIC LOCKS,

INTERCOMS, DOOR CONTACTS, CONDUIT, CABLING, VIDEO

SURVEILLANCE HEAD-END EQUIPMENT. "FUNCTIONAL CHECK"

RESULTS SHALL BE COMPILED AND DELIVERED TO THE OWNER.

CONTRACTOR SHALL NOTIFY OWNER OF ANY EQUIPMENT THAT DOES

NOT FUNCTION PROPERLY.

2. TERM "REMOVE" MEANS DISCONNECT, REMOVE FROM SITE AND

LEGALLY DISPOSE.

3. SECURITY EQUIPMENT, COMPONENTS, AND DEVICES SCHEDULED

FOR REMOVAL SHALL BE REMOVED IN SUCH A MANNER AS TO

PRESERVE THE APPEARANCE AND OPERABILITY TO THE GREATER

EXTENT POSSIBLE.

4. CONTRACTOR SHALL INVENTORY AND TURN OVER TO OWNER ALL

EQUIPMENT REMOVED DURING DEMO PHASE.

5. EXISTING SECURITY DEVICES SHALL REMAIN OPERATIONAL AS LONG

AS POSSIBLE. COORDINATE SECURITY SYSTEM OUTAGE TIME WITH

COTR AND BUILDING SECURITY.

6. IF SYSTEM OUTAGE EXTENDS BEYOND NORMAL BUSINESS HOURS;

THE CONTRACTOR SHALL INCUR THE COST FOR UTILIZING THE

OWNERS UNIFORMED GUARD SERVICE TO PROVIDE ADDITIONAL

SECURITY.

7. ALL EXISTING ELECTRICAL WORK WHICH WILL NOT BE RENDERED

OBSOLETE AND WHICH MAY BE DISTURBED DUE TO CHANGES

REQUIRED UNDER CONTRACT SHALL BE RESTORED TO ITS ORIGINAL

OPERATING CONDITION. OTHER ELECTRICAL MATERIAL RENDERED

OBSOLETE SHALL BE ABANDONED, DISCONNECTED, AND REMOVED

BACK TO SOURCE. REMOVAL SHALL STOP WHERE DAMAGE WOULD

OCCUR IF FURTHER REMOVAL OCCURRED. CUT CONDUIT OFF AND

REMOVE WIRE CONDUCTORS UNDER THESE CONDITIONS.

ABANDONED OUTLETS IN WALL SHALL BE REMOVED AND WALL

PATCHED AND PAINTED TO MATCH ADJACENT FINISH. NO BLANK

COVERS SHALL BE USED IN WALLS. ABANDONED OUTLETS ABOVE

CEILING SHALL BE COVERED WITH BRUSH STAINLESS STEEL COVER

PLATES OR PAINTED PLATES TO MATCH ADJACENT FINISH. ALL

UNUSED WIRING AND DEVICES SHALL BE REMOVED UON.

310.1

310.1

309.0

ELEC. DUCT

8" P

VC

A

HH

HH

HH

D

D

S

E

E

E

E

E

E

E E

HH

HH

C4

CLR

RC

IN

9x

N

N

N

N

N

N

D

D

D

D

D

D

SC 103

SC 101

SC 102

MU

ES

UM

EC

APS

DNARIA

LANOI

T A

N

DULLES CENTER

STEVEN F. UDVAR-HAZY CENTER

14585 Avion Parkway, Suite 150 Chantilly, Virginia 20151 www.PEGroup-Inc.com

703-488-9990 fax: 703-488-9994

KEY PLAN

GRAPHIC SCALE(S)

SEQUENCETYPEDISCIPLINE

CHECKED BYDRAWN BYDESIGNED BY

WORKING STAFF

DRAWING TYPE

DRAWING TITLE

PROJECT TITLE

A/E PROJECT NO.

ADDRESS

BUILDING NAME

SHEET NO.

OFEO PROJECT NUMBER

OF

Smithsonian Institution

Office of Facilities Engineering and Operations 600 Maryland Avenue S.W. Suite 5001

Washington DC 20024-2520

DATE

REVISION 1

REVISION

SUBMISSION

REVISION 2

REVISION 3

REVISION 4

REVISION 5

REVISION 6

REVISION 7

REVISION

11400 COMMERCE PARK DR., SUITE 400, RESTON, VA 20191

PHONE: 703-674-1300 FAX: 703-674-1350

WWW.KIMLEY-HORN.COM

SC

AL

E : 1

:1

Parking Entrance Control Upgrades

OVERALL PLAN

NASM - UDVAR HAZY CENTER

14930 Air & Space Museum Pkwy Chantilly, Virginia 20151

1354510 110408000

SK SK RH

SC 0 02

11/21/2014 FINAL BRIDGING DOCUMENTS

1" = 30'-0"SC 002

OVERALL PLAN - SECURITY1

# KEY NOTES

1 GATE HOUSE

2 INBOUND LANE

3 OUTBOUND LANE

4 EXISTING CAMERA WITH CAMERA POLE

TO BE RELOCATED

5 NEW LOCATION FOR RELOCATED

CAMERA POLE

6 EXISTING CAMERA POLE TO REMAIN.

PROVIDE NEW IP PTZ CAMERA AND

CAMERA WIRING. PROVIDE TVSS

DEVICES FOR CAMERA WIRING.

7 EXISTING OSP DUCT BANK (FIBER

OPTIC)

0 100' 200'

G112

G106

G107

G103

G105

G110

G112

G106

G107

G103

G105

G110

C1

CLR

RC

IN

CG01

CLRRCIN

CG02

CLRRCIN

AIC

A IC

D I

D I

D I

D I

A IC

A IC

EXISTING SECURITY

MONITORING STATION

DURESS BUTTON

INSTALLED AT

WORKSTATION DESK -

LOCATION TBD.

MU

ES

UM

EC

APS

DNARIA

LANOI

T A

N

DULLES CENTER

STEVEN F. UDVAR-HAZY CENTER

14585 Avion Parkway, Suite 150 Chantilly, Virginia 20151 www.PEGroup-Inc.com

703-488-9990 fax: 703-488-9994

KEY PLAN

GRAPHIC SCALE(S)

SEQUENCETYPEDISCIPLINE

CHECKED BYDRAWN BYDESIGNED BY

WORKING STAFF

DRAWING TYPE

DRAWING TITLE

PROJECT TITLE

A/E PROJECT NO.

ADDRESS

BUILDING NAME

SHEET NO.

OFEO PROJECT NUMBER

OF

Smithsonian Institution

Office of Facilities Engineering and Operations 600 Maryland Avenue S.W. Suite 5001

Washington DC 20024-2520

DATE

REVISION 1

REVISION

SUBMISSION

REVISION 2

REVISION 3

REVISION 4

REVISION 5

REVISION 6

REVISION 7

REVISION

11400 COMMERCE PARK DR., SUITE 400, RESTON, VA 20191

PHONE: 703-674-1300 FAX: 703-674-1350

WWW.KIMLEY-HORN.COM

SC

AL

E : 1

:1

Parking Entrance Control Upgrades

PARTIAL SITE PLAN - INBOUND

LANES AND GATE HOUSE

NASM - UDVAR HAZY CENTER

14930 Air & Space Museum Pkwy Chantilly, Virginia 20151

1354510 110408000

SK SK SK

SC 1 01

11/21/2014 FINAL BRIDGING DOCUMENTS

26 3/16" = 1'-0"SC 101

PARTIAL SITE PLAN - INBOUND

LANES AND GATE HOUSE1

KEY NOTES

1 EXISTING SECURITY PANELS LOCATION. EXISTING

DATA GATHERING PANEL (ACM), AND POWER

SUPPLIES. PROVIDE NEW SOFTWARE HOUSE

ISTAR PRO PANEL TO REPLACE THE EXISTING

DGP.

2 EXISTING CCTV SYSTEM ENCLOSURE.

3 EXISTING SECURITY CONTROL STATION.

4 UNDERGROUND CONDUIT.

5 EXISTING CAMERA POLE TO REMAIN AT SAME

LOCATION. PROVIDE NEW IP PTZ CAMERA. UTILIZE

EXISTING CONDUITS TO ROUTE NEW WIRING TO

CAMERA POLE. PROVIDE TVSS DEVICES FOR

CAMERA WIRING ROUTED BETWEEN THE GATE

HOUSE AND CAMERA POLE.

6 EXISTING INDOOR DOME CAMERA TO BE

REMOVED PRIOR TO GUARD BOOTH DEMOLITION

AND RETURNED TO THE OWNER.

7 EXISTING OSP DUCT BANK (FIBER OPTIC).

8 LOW VOLTAGE CONDUIT (SECURITY & TELECOM).

SHEET NOTES

1. EXISTING DATA GATHERING PANELS SHALL

REMAIN IN OPERATION DURING CONSTRUCTION.

2. REUSE EXISTING CAMERAS.

3. REPLACE EXISTING EXTERIOR POLE MOUNTED

CAMERAS WITH IP PTZ CAMERAS.

4. VIDEO RECORDING CAPPACITIES PROVIDED BY

THE OWNER. THE NEW IP BASED EXTERIOR PTZ

DOMES TO BE CONNECTED TO SI HEAD END

DEVICES VIA ETHERNET.

5. EXISTING MONITORS AND WORKSTATIONS SHALL

BE UTILIZED FOR LOCAL VIDEO SURVEILLANCE

(LOCAL=GATE HOUSE SECURITY DESK)

6. ALL SECURITY (CONDUCTIVE) WIRING ROUTED

OUTSIDE THE GATE HOUSE SHALL BE PROTECTED

WITH TVSS DEVICES.

7. PROVIDE WIRED DURESS BUTTON AT EACH GATE

HOUSE WORKSTATION.

8. PROVIDE INTEGRATION OF THE GATE

OPERATORS WITH SECURITY CONTROL SYSTEM.

THE GATE CLOSING AND OPENING SEQUENCES

BE ACTIVATED THROUGH SECURITY

MANAGEMENT SYSTEM. COORDINATE THE

PROGRAMMING REQUIREMENTS WITH SI OPS.

0 10' 20'

G106 G106

C2

CLR

RC

IN

C2

CLR

RC

IN

CG03

CLR

RC

IN

CG01CLRRCIN

CG03CLRRCIN

CG02CLRRCIN

CG02

CLR

RC

IN

D I

D I

A

IC

A

IC

A

IC

A

IC

A

IC

A

IC

A

IC

CASHIER BOOTH

A

IC

MU

ES

UM

EC

APS

DNARIA

LANOI

T A

N

DULLES CENTER

STEVEN F. UDVAR-HAZY CENTER

14585 Avion Parkway, Suite 150 Chantilly, Virginia 20151 www.PEGroup-Inc.com

703-488-9990 fax: 703-488-9994

KEY PLAN

GRAPHIC SCALE(S)

SEQUENCETYPEDISCIPLINE

CHECKED BYDRAWN BYDESIGNED BY

WORKING STAFF

DRAWING TYPE

DRAWING TITLE

PROJECT TITLE

A/E PROJECT NO.

ADDRESS

BUILDING NAME

SHEET NO.

OFEO PROJECT NUMBER

OF

Smithsonian Institution

Office of Facilities Engineering and Operations 600 Maryland Avenue S.W. Suite 5001

Washington DC 20024-2520

DATE

REVISION 1

REVISION

SUBMISSION

REVISION 2

REVISION 3

REVISION 4

REVISION 5

REVISION 6

REVISION 7

REVISION

11400 COMMERCE PARK DR., SUITE 400, RESTON, VA 20191

PHONE: 703-674-1300 FAX: 703-674-1350

WWW.KIMLEY-HORN.COM

SC

AL

E : 1

:1

Parking Entrance Control Upgrades

PARTIAL SITE PLAN -

OUTBOUND AND REVERSIBLE

LANES

NASM - UDVAR HAZY CENTER

14930 Air & Space Museum Pkwy Chantilly, Virginia 20151

1354510 110408000

SK SK RH

SC 1 02

11/21/2014 FINAL BRIDGING DOCUMENTS

3/16" = 1'-0"SC 102

PARTIAL SITE PLAN - OUTBOUND

AND REVERSIBLE LANES1

KEY NOTES

1 EXISTING CAMERA AND CAMERA POLE.

REPOSITION CAMERA POLE TO NEW LOCATION.

REPLACE SECURITY CAMERA WITH NEW IP PTZ

CAMERA.

2 NEW CAMERA POLE LOCATION.

3 EXISTING CAMERA TO BE REUSED.

4 DUAL INTERCOM/CARD READER PEDESTAL.

5 EXISTING INDOOR DOME CAMERA TO BE

RELOCATED FROM GUARD BOOTH.

6 EXISTING INDOOR DOME CAMERA TO BE

REMOVED PRIOR TO GUARD BOOTH DEMOLITION

AND RETURNED TO THE OWNER.

7 UNDERGROUND CONDUIT.

8 LOW VOLTAGE CONDUIT (SECURITY & TELECOM).

9 GATE WITH GATE OPERATOR - PROVIDE

PROGRAMMING AND INTERFACES AS REQUIRED

TO ACHIEVE THE INTEGRATION OF THE DOOR

OPERATOR WITH THE SECURITY MANAGEMENT

SYSTEM.

SHEET NOTES

1. PROVIDE NEW WIRING FOR CAMERAS

INSTALLED ON A REPOSITIONED CAMERA

POLES.

2. PROVIDE NEW WIRING FOR ALL…