EXHIBIT_R_-_JMMU_Target_designation_ref__TAB_B_-_Clusters_and_Moving_Infantry_Targets_(MITs).pdf

PDF 65 KB Posted

Attached to
Sources Sought notice - JMMU Range at Fort Hood, TX
Solicitation number
DOIDFBO260051
Issued by

About this file

This document is an exhibit reference table for JMMU (Joint Mobility and Maneuver Unit) Target Designation, specifically detailing clusters and Moving Infantry Targets (MITs) specifications.

The exhibit presents a comprehensive target designation matrix encompassing 15 clusters containing 105 targets, plus 12 SIT targets configured as SIT/SAT combos (C62, C64, C66) at three separate SAT locations (SAT420, SAT426, SAT440), for a total of 117 SITs. Each target is assigned a 6-fiber count, resulting in a total fiber requirement of 630 strands. Of these 630 fibers, 252 strands are positioned forward of the Line of Advance (LOA). Target specifications include standardized 16-inch front wall heights across all designations, with varying topography classifications (low, semi, or medium built-up), positioning relative to LOA (behind or forward), and super-elevation configurations. Power centers are designated across multiple power junction categories (PJ1A through PJ6A), with drawing references provided for each target. The ditch presence and semi-elevation requirements are indicated individually for each cluster designation, ranging from JC-1 through JC-15, with color-coded highlighting in the reference table indicating forward-of-LOA positions in red and specific configuration anomalies in magenta.

View the file

Other files

File Type Posted
EXHIBIT_AA___DMMU_MAT_System_locations_and_existing_conditions.pdf PDF
EXHIBIT_R_-_JMMU_Target_designation_ref__TAB_D_-_Drainage_(ditches_culverts_and_sump_pumps).pdf PDF
Fort_Hood_JMMU_Range_Upgrades_WORKIN_DRAFT_SOW_9Apr26.pdf PDF
EXHIBIT_Y_-_Range_Limit_Marker_Design.pdf PDF
EXHIBIT_L_-_JMMU_RANGE_SITE_SUMMARY_PCs_AND_CAMERA.pdf PDF
EXHIBIT_R_-_JMMU_Target_designation_ref__TAB_E_-_Power_Centers.pdf PDF
EXHIBIT_W_-_CCI-TII_Checklist.pdf PDF
EXHIBIT_V_-_CCI-TII_Checklist_Instructions.pdf PDF
EXHIBIT_A_-_FTHOOD-JMMU-AERIAL.pdf PDF
EXHIBIT_X_-_Portable_HSAT_Specifications.pdf PDF
EXHIBIT_R_-_JMMU_Target_designation_ref__TAB_F_-_Fiber_Optics.pdf PDF
EXHIBIT_M_-_Species_List_for_Range_Seed.pdf PDF
EXHIBIT_U_-_Gate_Design.pdf PDF
EXHIBIT_B_-_JMMU_CLUSTER_LOCATIONS_FOR_MIT_LOCATIONS.pdf PDF
EXHIBIT_P_-_ELECTRICAL_AND_COMMUNICATIONS.pdf PDF
EXHIBIT_E___Cluster_MIT_V-Shape_Formation.pdf PDF
EXHIBIT_T_-_Portable_Armored_Target_Protection.pdf PDF
EXHIBIT_Q___TC25-8_Minimum_MAT_Specification_Requirements.pdf PDF
EXHIBIT_O___Summary_Target_Electrical_and_Communications.pdf PDF
EXHIBIT_C_-_JMMU_MAT54_MAT56__MAT58___AT60_CROSS-SECTION.pdf PDF
EXHIBIT_R_-_JMMU_Target_designation_ref__TAB_A_-_Moving_Armored_Targets_(MATs).pdf PDF
EXHIBIT_S_-_Target_Protection_-_July_2017.pdf PDF
EXHIBIT_J_-_Moving_Armor_Target_(MAT)_-_Aug2017.pdf PDF
EXHIBIT_H_-_SIT_Cluster_November_2018.pdf PDF
EXHIBIT_G_-_Moving_InfantryTarget_(MIT)_-_Aug2017.pdf PDF
EXHIBIT_Z_-_JMMU_SACON_Trench_System_Repairs.pdf PDF
EXHIBIT_N_-_Mandatory_Shutdown_times.pdf PDF
EXHIBIT_K_-_TXDOT_Concrete_Repair_Manual_crm.pdf PDF
EXHIBIT_D_-_Moving_Armor_Target_MAT_Locations.pdf PDF
EXHIBIT_R_-_JMMU_Target_designation_ref__TAB_C_-_Startionary_Armored_Targets_(SATs).pdf PDF
EXHIBIT_I_-_Stationary_ArmorTarget_(SAT)_-_Aug2017.pdf PDF
Show all 31

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

EXHIBIT R - JMMU Target Designation Ref:

TAB B - Clusters and Moving Infantry Targets (MITs) cluster CURRENT

DESIGNATION

designation

BUILD MIT

AT TGT# topography notes drawing

Front Wall Height? Ditch?

Super Elevated powered by power center fiber count fiber fed from

C12 JC-1

Behind LOA low 16-inches No No PJ2A 42 PJ2A C14 JC-2 1 Behind LOA low 16-inches No Semi PJ2A 42 PJ2A

C16 JC-5 1 Behind LOA semi 16-inches No Semi PJ2B 42 PJ2B C18 JC-8 1 Behind LOA semi 16-inches No Semi PJ2B 42 PJ2B C20 JC-4 1 Behind LOA semi 16-inches No Semi PJ1A 42 PJ1A

C22 JC-6 7 Behind LOA semi 16-inches No Semi PJ3A 42 PJ3A C24 JC-7 7 Behind LOA med built up 16-inches No Yes PJ4A 42 PJ4A C26 JC-9 no Forward of LOA low 16-inches No Semi JP6A 42 JP6A C28 JC-3 7 Forward of LOA low 16-inches No No JP6A 42 JP6A

C30 JC-10

Behind LOA low 16-inches Ditch No PJ5A 42 PJ5A

C32 JC-11

Behind LOA semi 16-inches No Semi PJ4B 42 PJ4B C34 JC-14 1 Forward of LOA semi 16-inches No Semi PJ5A 42 PJ5A

C36 JC-12 7 Forward of LOA low 16-inches Ditch No JP6A 42 JP6A C38 JC-13 no Forward of LOA semi 16-inches No Semi JP6A 42 JP6A

C40 JC-15

Forward of LOA LOW 16-inches Ditch No PJ5B 42 PJ5B C62 C64 C66 other Clusters at heavy SATs

15 clusters = 105 targets SIT/SAT COMBOs (C62, C64, C66)= 12 SIT targets @ 3 SATS (SAT420, SAT426, SAT440) TOTAL 117 SITs each target receives 6 fiber count for a total of 630 fiber count

(42 SITs) 252 strands forward of LOA

File details come from the government source that posted it. Updated .