EXHIBIT Q - PACT Space Module Design Guide.pdf

PDF 274 KB Posted

Attached to
X1DZ--Adams County Community Base Outpatient Clinic
Solicitation number
36C24424R0032
Issued by

About this file

This document is the PACT Space Module Design Guide, which provides design guidance for the layout and organization of a Patient Aligned Care Team (PACT) clinic for the Department of Veterans Affairs.

The guide illustrates a prototype clinic design with key functional zones, including a Teamwork Zone, Patient Corridor, and Patient Transition Area. It discusses design considerations such as the arrangement of patient care rooms, staff access corridors, and space allocation. The guide notes that a related CBOC Prototype Study resulted in a variation with a wider Teamwork Zone, allowing for reconfiguration opportunities. Overall, the design guide outlines the intended layout and organization for a PACT clinic space.

View the file

Other files

File Type Posted
EXHIBIT AD - VA Provision Addendum Alternate Protest Procedure - Real Property Lease Procurements.pdf PDF
36C24424R0032.docx DOCX document
36C24424R0032_2.docx DOCX document
EXHIBIT W - Signage Design Manual.pdf PDF
EXHIBIT A - 36C24424L0002.docx DOCX document
EXHIBIT AB - FAR 52.204-25 Reporting Clause 8 2020.docx DOCX document
EXHIBIT B AgencyTechnical Requirements Adams 03.18.24.docx DOCX document
EXHIBIT H - Prelease FPLS Evaluation Form 12000.docx DOCX document
EXHIBIT Z - Past Performance Questionnaire.docx DOCX document
EXHIBIT E - 3517B General Clauses.Oct. 2023.docx DOCX document
EXHIBIT AA - FAR 52.204-24 Representation Digital.docx DOCX document
36C24424R0032_1.docx DOCX document
EXHIBIT J - Security Standards.pdf PDF
EXHIBIT AC - LA-23-04 FAR Clause 52.204-27.docx DOCX document
EXHIBIT N - Tenant Improvements Cost Summary.TICS.Table.Jul. 2022.xlsx XLSX spreadsheet
EXHIBIT K - Security Unit Price List FSL II.Jun. 2022.xlsx XLSX spreadsheet
EXHIBIT F - 1364 Proposal to Lease Space .Jan. 2023.pdf PDF
EXHIBIT O - Contract Submittal Schedule.docx DOCX document
EXHIBIT D - 3516 Solicitation Provisions.Oct. 2023.docx DOCX document
EXHIBIT M - Unit Price List. AdamsCounty.xlsx XLSX spreadsheet
EXHIBIT P - Space Requirement.docx DOCX document
EXHIBIT G - Form 1217 - Lessor_s Annual Cost Statement.Nov. 2016.pdf PDF
EXHIBIT C - Security Requirements.FSL Level II.1.12.24.docx DOCX document
EXHIBIT L - DOL Wage Determination.pdf PDF
Show all 24

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PACT Space Module Design Guide 2015

U.S. Department of Veterans Affairs Office of Construction and Facilities Management

4.0 PLANNING AND DESIGN

4.1 Clinic Organization

31’-0”

+/- MAX.

S

IN

G

LE

D O

O R

A C

C E

S S

STAFF CORRIDOR

TEAMWORK ZONE

E Q

P T

MEDICATION

PATIENT TRANSITION AREA

TEAMWORK SUPPORT ZONE

PA

TI

E N

T C

O R

R

ID

O R

PA

TI

E N

T C

O R

R

ID

O R

STORAGE

PROC

ROOM

STAFF TLT

GROUP CARE

ROOM

PAT. TLT

CONSULT/

EXAM

CONSULT/

EXAM

CONSULT/

EXAM

SUPPORT

CONSULT/

EXAM

CONSULT/

EXAM

CONSULT/

EXAM

Figure 4.1-2 PACT Prototype Design Diagram

CONSULT/

EXAM

PATIENT CORRIDOR

In parallel to the development of the PACT Space Module, VA-CFM was conducting a CBOC Prototype Study through a VA Innovation Project. This Study arrived at a variation of the PACT Space Module;

the Team Work Zone is approximately 30 feet wide in the Prototype developed in the Study.

This width provides a greater net square foot area in the Team Work Zone. With this wider spacing, the Team Work Zone in the future could be reconfigured to include two 6’-0” wide corridors and enclosed functional space.

Utilization of the CBOC Prototype requires additional PACT Care Team members to be located in this Zone. To maintain the program level of net square foot area in the Team Work Zone, the length of the zone is shorter as compared to the PACT Space Module’s Team Work Zone. This results in approximately six (6) patient care rooms being located along the Patient Corridor with single door access vs. the dual door access as provided in patient care rooms that are located adjacent to the Team Work Zone. Staff in turn will utilize the Access Hallway and co-mingle with patients in the Patient Corridor to access these outer rooms.

If this outer layer of patient care rooms is positioned adjacent to the Team Work Zone, the length of the Team Work Zone would become greater, providing an excess of net square foot area in the Work Zone.

CONSULT/

EXAM

PAT. TLT

CONSULT/

EXAM

CONSULT/

EXAM

CONSULT/

EXAM

CONSULT/

EXAM

CONSULT/

EXAM

CONSULT/

EXAM

CONSULT/

EXAM

CONSULT/

EXAM

S U

P P

LY

EXHIBIT Q

LEASE NO. 36C24424L0002 LESSOR:___________ GOVERNEMENT:_____________

Adams County CBOC

File details come from the government source that posted it. Updated .