ISSUE / REVISION

DATE:

NOT TO SCALE

ACCEPTABLE SYSTEMS:

DETAIL NO.

07/18/2019ULTRAPLY TPO

UT-PE-3

TM

MAXIMUM WARRANTY: 20 Years

ALL

BATTEN WITH 5.5" ULTRAPLY TPO QUICKSEAM

FLASHING AT PERIMETER ENHANCEMENT

SPACING VARIES WITH SHEET WIDTH AND FROM JOB TO JOB

5 m

m) M

AX

HD SEAM PLATES

FASTENED 12" (305 mm)

O.C. MAX. WITH FIRESTONE

FASTENERS

ROOF EDGE - REFER TO ROOF EDGE DETAILS

FIELD OF THE ROOF

5 m

m) M

AX

3" (7

6 m m)

MUST EXTEND THE

ENTIRE PRESCRIBED

PERIMETER AREA

REFER TO THE

ATTACHMENT

LAYOUTS FOR

EACH SPECIFIC

PROJECT

FIELD SEAM WITH

1.5" ROBOTIC WELD

BATTEN FASTENED

12" (305 mm O.C.) WITH

FASTENERS

2" (51 mm) DIAMETER

FIELD-CUT TPO PAD

(SEE NOTE #4)

NOTE:

1. REFER TO WEBSITE FOR MOST CURRENT

INFORMATION.

2. REFER TO UT-PE-7 FOR 9.5" TPO QUICKSEAM

FLASHING DETAIL.

3. APPLY TPO GENERAL PURPOSE SEALANT TO

CUT ENDS OF QUICKSEAM FLASHING.

4. INSTALL 2" DIAMETER FIELD CUT TPO PAD

UNDER BATTEN TERMINATING ENDS.

5. TO ENSURE FORMABILITY, SLIGHTLY

HEAT-FORM THE SURFACE OF TPO

QUICKSEAM PRODUCTS AT STEP-OFFS AND

ANGLE CHANGES.

6. USE AN ACCEPTABLE PRIMER TO CLEAN

AND PRIME TPO MATING SURFACE PRIOR

TO INSTALLATION OF QUICKSEAM

PRODUCTS.

FIELD SEAM WITH

1.5" ROBOTIC WELD

5.5" (140 mm)

ULTRAPLY TPO

QUICKSEAM FLASHING

(SEE NOTE #3, #5 AND #6)

0 1"

A N

S I

D

P r o j e c t

W o r k

O r d e r

N o

A P

P R

SHEET REFERENCE

NUMBER

D E

S I G

N E

D

B

Y

D W

N

B

Y

C K

D

B

Y

S U

B M

I T

T E

D

B

Y

F I L E

N

A M

E

S I Z

E

P L O

T T

D

B

Y

S C

A L E

C O

N T

R A

C T

U M

B E

R S

W O

R K

O

D

U M

B E

R

D A

T E

M A

R K

D E

S C

R I P

T I O

N D

A T

E A

P P

R

M A

R K

D E

S C

R I P

T I O

N D

A T

E

Ft. Drum

Public Works

Engineering Branch

54321

D

C

B

A

C O

N T

R A

C T

O R

SITE LOCATION

M a r

F o r t

D r u m

N e w

Y o r k

AutoCAD SHX Text P U B L I C W O R K S

AutoCAD SHX Text

FORT DRUM, NEW YORK

AutoCAD SHX Text Drawing Location.:

AutoCAD SHX Text Submitted by:

AutoCAD SHX Text Plot Date:

AutoCAD SHX Text WARNING: THIS DOCUMENT MAY CONTAIN SENSITIVE SECURITY INFORMATION AND THEREFORE MUST BE TREATED AS A CONFIDENTIAL DOCUMENT. THE INFORMATION CONTAINED IN THIS DOCUMENT MUST BE MAINTAINED IN A CONFIDENTIAL MANNER TO PREVENT COMPROMISING HOMELAND SECURITY AS PROVIDED IN SECTION 214 OF THE HOMELAND SECURITY ACT OF 2002. NO PART OF THIS DOCUMENT SHALL BE REPRODUCED, RELEASED OR DISTRIBUTED WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE CONTRACTING OFFICER. UNAUTHORIZED REPRODUCTION, RELEASE OR DISTRIBUTION MAY RESULT IN CIVIL PENALTY OR OTHER ACTION BY THE GOVERNMENT.

AutoCAD SHX Text ALL DIMENSIONS/EXISTING CONDITIONS SHOWN SHALL BE CHECKED AND VERIFIED BY THE CONTRACTOR AT THE SITE, ANY DISCREPANCIES SHALL BE IMMEDIATELY REPORTED TO THE GOVERNMENT FOR CLARIFICATIONS. DRAWING SHALL NOT BE SCALED TO OBTAIN DIMENSIONS OR DISTANCES.

AutoCAD SHX Text FORT DRUM PUBLIC WORKS ENGINEERING BRANCH 4894 NINNINGER ROAD FORT DRUM, NY 13602

AutoCAD SHX Text THIS BAR IS ONE INCH ON ORIGINAL DRAWING IF NOT ONE INCH ON THIS SHEET, ADJUST SCALES ACCORDINGLY

AutoCAD SHX Text 10-Mar-21

AutoCAD SHX Text UT-PE-3 Perimeter Enhancement

AutoCAD SHX Text C:\Users\roger.c.hurd.civ\Desktop

Sheets and Views
11x17

File details come from the government source that posted it. Updated .