USACE / NAVFAC / AFCEC / NASA UFGS- 07 13 53 ( Febr uar y 2016) Change 1 - 08/ 17 Pr epar i ng Act i v i t y: NAVFAC Super sedi ng UFGS- 07 13 53 ( Apr i l 2006)
UNI FI ED FACI LI TI ES GUI DE SPECI FI CATI ON
Ref er ences ar e i n agr eement wi t h UMRL dat ed Januar y 2021
SECTION TABLE OF CONTENTS
DIVISION 07 - THERMAL AND MOISTURE PROTECTION
SECTION 07 13 53
ELASTOMERIC SHEET WATERPROOFING
02/ 16, CHG 1: 08/ 17
PART 1 GENERAL
1.1 REFERENCES
1.2 SUBMITTALS
1.3 MANUFACTURER'S DETAILS
1.4 PRODUCT DATA
1.5 CODE REQUIREMENTS
1.6 DELIVERY, STORAGE, HANDLING, IDENTIFICATION
1.7 ENVIRONMENTAL CONDITIONS
1.8 SPECIAL WARRANTIES
1.8.1 Guarantee
1.8.2 Warranty
PART 2 PRODUCTS
2.1 SUSTAINABILITY CRITERIA
2.1.1 Reduced Volatile Organic Compound (VOC) Content
2.1.2 Recycled Content
2.2 MATERIALS
2.3 BUTYL RUBBER SHEETING
2.3.1 Butyl Rubber Sheeting Performance Requirements
2.3.2 Adhesive, Cement, and Tape for Use with Butyl Rubber
2.4 THERMOPLASTIC MEMBRANE: POLYVINYL CHLORIDE (PVC)
2.4.1 Thermoplastic Membrane Performance Requirements
2.4.2 Adhesives
2.4.3 Accessories
2.5 COMPOSITE, SELF-ADHERING MEMBRANE SHEETING
2.5.1 Composite, Self-Adhering Sheeting Performance Requirements
2.5.2 Primers
2.5.3 Mastics
2.6 Protection Board
PART 3 EXECUTION
3.1 VERIFICATION OF CONDITIONS
SECTION 07 13 53 Page 1
3.2 SURFACE PREPARATION
3.3 APPLICATION
3.3.1 Building Envelope Requirements
3.3.2 General Installation Requirements
3.3.2.1 Non-Self-Adhering Membrane
3.3.2.2 Self-Adhering Membrane
3.3.2.3 Protection
3.3.3 Butyl Rubber
3.3.4 Thermoplastic Membrane (PVC)
3.4 COMPOSITE, SELF-ADHERING MEMBRANE
3.5 FLASHING
3.6 FIELD QUALITY CONTROL
3.7 PROTECTIVE COVERING
-- End of Section Table of Contents --
SECTION 07 13 53 Page 2
USACE / NAVFAC / AFCEC / NASA UFGS- 07 13 53 ( Febr uar y 2016) Change 1 - 08/ 17 Pr epar i ng Act i v i t y: NAVFAC Super sedi ng UFGS- 07 13 53 ( Apr i l 2006)
UNI FI ED FACI LI TI ES GUI DE SPECI FI CATI ON
Ref er ences ar e i n agr eement wi t h UMRL dat ed Januar y 2021
SECTION 07 13 53
ELASTOMERIC SHEET WATERPROOFING
02/ 16, CHG 1: 08/ 17
NOTE: Thi s gui de speci f i cat i on cover s t he r equi r ement s f or sheet appl i ed el ast omer i c waterproofing.
Adher e t o UFC 1-300-02 Uni f i ed Faci l i t i es Gui de Speci f i cat i ons ( UFGS) For mat St andar d when edi t i ng t hi s gui de speci f i cat i on or pr epar i ng new pr oj ect speci f i cat i on sect i ons. Edi t t hi s gui de speci f i cat i on f or pr oj ect speci f i c r equi r ement s by addi ng, del et i ng, or r evi s i ng t ext . For br acket ed i t ems, choose appl i cabl e i t em( s) or i nser t appr opr i at e i nf or mat i on.
Remove i nf or mat i on and r equi r ement s not r equi r ed i n r espect i ve pr oj ect , whet her or not br acket s ar e present.
Comment s, suggest i ons and r ecommended changes f or t hi s gui de speci f i cat i on ar e wel come and shoul d be submi t t ed as a Criteria Change Request (CCR) .
NOTE: Thi s gui de speci f i cat i on i s i nt ended f or use wher e l ocal pr act i ce and exper i ence i ndi cat es, or wher e I nt er nat i onal Code Counci l ( I CC) , I nt er nat i onal Bui l di ng Code ( I BC) , sect i on Damppr oof i ng and Wat er pr oof i ng al l ows, t hat pr ot ect i on agai nst hydr ost at i c pr essur e or condi t i ons of excessi ve dampness can be achi eved by usi ng el ast omer i c wat er pr oof i ng. Typi cal appl i cat i ons i ncl ude, but ar e not l i mi t ed t o, wal l and f oundat i on wat er pr oof i ng, wat er pr oof i ng pr omenades and par ki ng decks, wat er pr oof i ng beneat h shower pans, k i t chens, t oi l et f aci l i t i es, j ani t or i al r ooms, and i ndoor swi mmi ng pool s.
NOTE: Wher e gr oundwat er i nvest i gat i on r equi r ed by I BC Sect i on 1803. 5. 4 i ndi cat es t hat i f a hydr ost at i c pr essur e condi t i on exi st s, and t he desi gn does not
SECTION 07 13 53 Page 3 i ncl ude a gr oundwat er cont r ol syst em as descr i bed i n Sect i on 1805. 1. 3, wat er pr oof wal l s and f l oor s i n accor dance wi t h t hi s sect i on.
NOTE: Wher e concr et e vaul t magazi nes ar e desi gned bel ow gr ound, pr ovi de but yl r ubber , or el ast omer i c composi t e, t her mopl ast i c wat er pr oof sheet i ng.
NOTE: On t he dr awi ngs, show:
1. Ext ent of membr ane wat er pr oof i ng, subst r at es, t er mi nat i on det ai l s, t er mi nat i on det ai l s, f l ashi ng, and count er f l ashi ng, pi pe and condui t penet r at i ons, and j unct i ons at wal l s and f l oor s.
PART 1 GENERAL
1.1 REFERENCES
NOTE: Thi s par agr aph i s used t o l i s t t he publ i cat i ons c i t ed i n t he t ext of t he gui de speci f i cat i on. The publ i cat i ons ar e r ef er r ed t o i n t he t ext by basi c desi gnat i on onl y and l i s t ed i n t hi s par agr aph by or gani zat i on, desi gnat i on, dat e, and t i t l e.
Use t he Ref er ence Wi zar d' s Check Ref er ence f eat ur e when you add a Ref er ence I dent i f i er ( RI D) out si de of t he Sect i on' s Ref er ence Ar t i c l e t o aut omat i cal l y pl ace t he r ef er ence i n t he Ref er ence Ar t i c l e. Al so use t he Ref er ence Wi zar d' s Check Ref er ence f eat ur e t o updat e t he i ssue dat es.
Ref er ences not used i n t he t ext wi l l aut omat i cal l y be del et ed f r om t hi s sect i on of t he pr oj ect speci f i cat i on when you choose t o r econci l e r ef er ences i n t he publ i sh pr i nt pr ocess.
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
ASTM INTERNATIONAL (ASTM)
ASTM C1305 (2008) Standard Test Method for Crack Bridging Ability of Liquid-Applied Waterproofing Membrane
ASTM D41/D41M (2011; R 2016) Standard Specification for Asphalt Primer Used in Roofing, Dampproofing, and Waterproofing
ASTM D146/D146M (2004; E 2012; R 2012) Sampling and
SECTION 07 13 53 Page 4
Testing Bitumen-Saturated Felts and Woven Fabrics for Roofing and Waterproofing
ASTM D297 (2015; R 2019) Rubber Products - Chemical Analysis
ASTM D412 (2016) Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers - Tension
ASTM D429 (2014) Rubber Property-Adhesion to Rigid Substrates
ASTM D471 (2016a) Standard Test Method for Rubber Property - Effect of Liquids
ASTM D570 (1998; E 2010; R 2010) Standard Test Method for Water Absorption of Plastics
ASTM D573 (2004; R 2019) Standard Test Method for Rubber - Deterioration in an Air Oven
ASTM D624 (2000; R 2020) Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
ASTM D638 (2014) Standard Test Method for Tensile Properties of Plastics
ASTM D746 (2014) Standard Test Method for Brittleness Temperature of Plastics and Elastomers by Impact
ASTM D751 (2006; R 2011) Coated Fabrics
ASTM D903 (1998; R 2017) Standard Test Method for Peel or Stripping Strength of Adhesive Bonds
ASTM D1004 (2013) Initial Tear Resistance of Plastic Film and Sheeting
ASTM D1149 (2007; R 2012) Standard Test Method for Rubber Deterioration - Surface Ozone Cracking in a Chamber
ASTM D1204 (2014; R 2020) Linear Dimensional Changes of Nonrigid Thermoplastic Sheeting or Film at Elevated Temperature
ASTM D1876 (2008; R 2015; E 2015) Standard Test Method for Peel Resistance of Adhesives (T-Peel Test)
ASTM D2136 (2002; R 2012) Coated Fabrics - Low-Temperature Bend Test
ASTM D2240 (2015; E 2017) Standard Test Method for Rubber Property - Durometer Hardness
SECTION 07 13 53 Page 5
ASTM D3045 (1992; R 2010) Practice for Heat Aging of Plastics Without Load
ASTM D5385/D5385M (1993; R 2014; E 2014) Standard Test Method for Hydrostatic Pressure Resistance of Waterproofing Membranes
ASTM E96/E96M (2016) Standard Test Methods for Water Vapor Transmission of Materials
ASTM E154/E154M (2008a; R 2013; E 2013) Water Vapor Retarders Used in Contact with Earth Under Concrete Slabs, on Walls, or as Ground Cover
INTERNATIONAL CODE COUNCIL (ICC)
ICC IBC (2018) International Building Code
1.2 SUBMITTALS
NOTE: Revi ew Submi t t al Descr i pt i on ( SD) def i ni t i ons i n Sect i on 01 33 00 SUBMI TTAL PROCEDURES and edi t t he f ol l owi ng l i s t , and cor r espondi ng submi t t al i t ems i n t he t ext , t o r ef l ect onl y t he submi t t al s r equi r ed f or t he pr oj ect . The Gui de Speci f i cat i on t echni cal edi t or s have cl assi f i ed t hose i t ems t hat r equi r e Gover nment appr oval , due t o t hei r compl exi t y or cr i t i cal i t y, wi t h a " G. " Gener al l y, ot her submi t t al i t ems can be r evi ewed by t he Cont r act or ' s Qual i t y Cont r ol Syst em. Onl y add a " G" t o an i t em i f t he submi t t al i s suf f i c i ent l y i mpor t ant or compl ex i n cont ext of t he pr oj ect .
For Ar my pr oj ect s, f i l l i n t he empt y br acket s f ol l owi ng t he " G" c l assi f i cat i on, wi t h a code of up t o t hr ee char act er s t o i ndi cat e t he appr ovi ng aut hor i t y. Codes f or Ar my pr oj ect s usi ng t he Resi dent Management Syst em ( RMS) ar e: " AE" f or Ar chi t ect - Engi neer ; " DO" f or Di st r i ct Of f i ce ( Engi neer i ng Di v i s i on or ot her or gani zat i on i n t he Di st r i ct Of f i ce) ; " AO" f or Ar ea Of f i ce; " RO" f or Resi dent Of f i ce; and " PO" f or Pr oj ect Of f i ce. Codes f ol l owi ng t he " G" t ypi cal l y ar e not used f or Navy, Ai r For ce, and NASA pr oj ect s.
The " S" c l assi f i cat i on i ndi cat es submi t t al s r equi r ed as pr oof of compl i ance f or sust ai nabi l i t y Gui di ng Pr i nci pl es Val i dat i on or Thi r d Par t y Cer t i f i cat i on and as descr i bed i n Sect i on 01 33 00 SUBMI TTAL
PROCEDURES.
Choose t he f i r st br acket ed i t em f or Navy, Ai r For ce, and NASA pr oj ect s, or choose t he second br acket ed i t em f or Ar my pr oj ect s.
SECTION 07 13 53 Page 6
Government approval is required for submittals with a "G" or "S" classification. Submittals not having a "G" or "S" classification are [for Contractor Quality Control approval.][for information only. When used, a code following the "G" classification identifies the office that will review the submittal for the Government.] Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:
SD-03 Product Data
Manufacturer's Standard Details ; G[, [_____]]
Elastomeric Waterproofing Sheet Material ; G[, [_____]]
Protection Board ; G[, [_____]]
Primers, Adhesives, and Mastics ; G[, [_____]]
SD-06 Test Reports
Elastomeric Waterproofing Sheet Material ; G[, [_____]]
Field Quality Control documentation; G[, [_____]]
Protective Covering ; G[, [_____]]
NOTE: Cer t i f i cat es ar e r equi r ed f or ver i f i cat i on of mat er i al s compl yi ng wi t h UFC 1- 200- 02 HI GH
PERFORMANCE AND SUSTAI NABLE BUI LDI NG REQUI REMENTS;
edi t as necessar y.
SD-07 Certificates
Elastomeric Waterproofing Sheet Material ; G [, [_____]]
Primers, Adhesives, and Mastics ; G[, [_____]]
[ Protective Coverings ; G[, [_____]]
] Draft Special Warranties ; G[, [_____]]
Final Special Warranties ; G[, [_____]]
Certificates Of Compliance ; G[, [_____]]
SD-08 Manufacturer's Instructions
Primers, Adhesives, and Mastics ; G[, [_____]]
SD-11 Closeout Submittals
Certificates Of Compliance with sustainable requirements for items listed in SD-07; G[, [_____]]
1.3 MANUFACTURER'S DETAILS
Submit manufacturer's standard details indicating methods of attachment
SECTION 07 13 53 Page 7 and spacing, transition and termination details, and installation details. Include verification of existing conditions.
1.4 PRODUCT DATA
Include data for material descriptions, recommendations for product shelf life, requirements for protective coverings , and manufacturer's Safety Data Sheets (SDS) for primers, adhesives, and mastics .
NOTE: Choose br acket ed opt i on i f t hi s pr oj ect i s r equi r ed t o compl y wi t h I CC I BC Sect i on 1805 Damppr oof i ng and Wat er pr oof i ng.
[ 1.5 CODE REQUIREMENTS
Provide membrane waterproofing system in accordance with ICC IBC Section 1805 Dampproofing and Waterproofing.
] 1.6 DELIVERY, STORAGE, HANDLING, IDENTIFICATION
Deliver and store materials in accordance with manufacturer's printed instructions, out of the weather, in manufacturer's original packaging with brand name and product identification clearly marked. Keep materials wrapped and separated from off-gassing materials (such as drying paints and adhesives). Do not use materials that have visible moisture or biological growth. Do not permit unidentified materials in the work area or in the project.
1.7 ENVIRONMENTAL CONDITIONS
NOTE: When wat er pr oof i ng wi l l be i nst al l ed i ndoor s pr ot ect ed f r om t he weat her , del et e t he br acket ed r equi r ement s f or out door envi r onment al condi t i ons.
Al so, i n geogr aphi cal ar eas wher e t he speci f i er det er mi nes i t i s r out i ne t o ut i l i ze ar t i f i c i al means of mai nt ai ni ng t he sur f ace and ambi ent t emper at ur es above 4 degr ees C 40 degr ees F, i ncl ude t he condi t i ons f or wai ver i n t he pr oj ect speci f i cat i ons.
Do not apply waterproofing during inclement weather or when there is ice, frost, surface moisture, or visible dampness on the surface to receive waterproofing for when ambient and surface temperatures are 4 degrees C 40 degrees F or below. [The restriction on the application of waterproofing materials when ambient and surface temperatures are below 4 degrees C 40 degrees F will be waived if the Contractor devises a means, approved by the Contracting Officer in writing, of maintaining the surface and ambient temperatures above 4 degrees C 40 degrees F .]
1.8 SPECIAL WARRANTIES
1.8.1 Guarantee
Guarantee waterproofing membrane installation against failure due to leaks for a period of two years from the date of Beneficial Occupancy. Submit draft and final guarantees in accordance with Sections 01 78 00 CLOSEOUT
SECTION 07 13 53 Page 8
SUBMITTALS [and 01 78 23 OPERATION AND MAINTENANCE DATA].
1.8.2 Warranty
Provide manufacturer's material warranty for all system components for a period of ten years from the date of Beneficial Occupancy. Submit draft and final warranties in accordance with Sections 01 78 00 CLOSEOUT SUBMITTALS [and 01 78 23 OPERATION AND MAINTENANCE DATA].
PART 2 PRODUCTS
2.1 SUSTAINABILITY CRITERIA
Where allowed by performance criteria:
2.1.1 Reduced Volatile Organic Compound (VOC) Content
Provide products with reduced VOC content and provide certificates of compliance in accordance with Section 01 33 29 SUSTAINABILITY REQUIREMENTS AND REPORTING paragraph REDUCE VOLATILE ORGANIC COMPOUNDS.
2.1.2 Recycled Content
Provide products with recycled content and provide certificates of compliance in accordance with Section 01 33 29 SUSTAINABILITY REQUIREMENTS AND REPORTING paragraph RECYCLED CONTENT.
2.2 MATERIALS
Provide one of the types of elastomeric waterproofing sheet material and related primers, adhesives, and mastics as specified herein. Ensure compatibility of waterproofing materials with each other, and with materials on which they are applied. Provide materials that comply with applicable requirements cited below when tested in accordance with the referenced ASTM publications.
NOTE: Wher e concr et e vaul t magazi nes ar e desi gned bel ow gr ound, speci f y membr ane sheet i ng. Do not appl y pr i mer or mast i c unt i l concr et e has cur ed not l ess t han 7 days, or as r equi r ed by t he manuf act ur er , r emove al l moi st ur e, f or m oi l and non-f ungi cur i ng agent s.
NOTE: Speci f y a hi gher punct ur e r esi st ance i f wat er pr oof i ng wi l l be subj ect t o abuse. Commer ci al membr anes ar e avai l abl e whi ch exceed 890 N 200 pounds i n punct ur e r esi st ance.
2.3 BUTYL RUBBER SHEETING
Not less than 1.5 mm 60 mils minimum thickness.
2.3.1 Butyl Rubber Sheeting Performance Requirements
a. Thickness Tolerance, ASTM D412: Plus or minus 10 percent.
b. Specific Gravity, ASTM D297: 1.20, plus or minus 0.05.
SECTION 07 13 53 Page 9
c. Tensile Strength, ASTM D412: 7.7 MPa 1200 psi minimum.
d. Tensile Stress at 300 percent elongation, ASTM D412: 3.85 MPa 600 psi minimum.
e. Elongation, ASTM D412: 300 percent minimum.
f. Tear Resistance, Die C, ASTM D624: 26.3 Newtons per millimeter (N/mm) 150 pound force per inch (lbf/inch) minimum.
g. Shore A Hardness, ASTM D2240: 5-second interval before reading; 60 plus or minus 10.
h. Ozone Resistance, ASTM D1149: No cracks, 7 days - 50 pphm - 37.8 degrees C 100 degrees F , 20 percent elongation.
i. Heating Aging-Accelerated, ASTM D573: Tensile retention, 60 percent of minimum original elongation retention; 60 percent of minimum original requirement; 7 days, 115.6 degrees C 240 degrees F .
j. Butyl Identification, ASTM D471 REV A, Tricresyl Phosphate Immersion:
Maximum volume swell 10 percent, 70 hrs, 100 degrees C 212 degrees F .
k. Low Temperature Flexibility, ASTM D746: No failure at minus 40 degrees C minus 40 degrees F .
l. Water Absorption, ASTM D471 REV A: Plus 1 percent maximum. 7 days, 70 degrees C 158 degrees F .
m. Exposure to Fungi and Bacteria in Soil, ASTM E154/E154M REV A, Minimum 16 Weeks: Unaffected.
n. Water Vapor Transmission, 26.7 degrees C 80 degrees F Permeance, ASTM E96/E96M, Procedure B or BW: 8.58 by 10-7 g/Pa.s.m2 0.15 perms maximum.
2.3.2 Adhesive, Cement, and Tape for Use with Butyl Rubber
As recommended by the butyl rubber waterproofing membrane manufacturer.
2.4 THERMOPLASTIC MEMBRANE: POLYVINYL CHLORIDE (PVC)
Polyvinyl chloride (PVC) flexible sheets with non-woven fiberglass reinforcing not less than 1.5 mm 60 mils minimum thickness.
2.4.1 Thermoplastic Membrane Performance Requirements
a. Overall thickness, ASTM D751: 1.50 mm .059 inches minimum
b. Tensile strength, ASTM D638: 11.03 MPa 1600 psi minimum
c. Elongation at break, ASTM D638: 250 percent minimum
d. Seam strength, ASTM D638: 90 percent minimum of tensile strength
e. Retention of properties after heat aging, ASTM D3045
f. Tensile strength, ASTM D638: 95 percent of original
SECTION 07 13 53 Page 10
g. Elongation, ASTM D638: 95 percent of original
h. Tear resistance, ASTM D1004: 7.7 Kilogram Force 17 lbf
i. Low Temperature Bend, ASTM D2136: minus 40 degrees C minus 40 degrees F
j. Liner Dimensional Change, ASTM D1204: 0.002 percent
k. Weight Change After Immersion in Water, ASTM D570: 2.0 percent maximum
2.4.2 Adhesives
a. Adhesive for thermoplastic flashings as recommended by manufacturer.
b. Adhesive for Sub-Membrane Grid: 100 percent solids, two part urethane, with minimum tensile strength of 1.04 MPa 150 psi , in accordance with ASTM D412 and adhesion to concrete of 12 ply in accordance with ASTM D429 as recommended by manufacturer.
NOTE: Wher e r ecommended by t he manuf act ur er f or bel ow gr ound membr ane sheet i ng, pr ovi de secur ement st r i p at per i met er and at any penet r at i ons( s) as wel l as any el evat i on changes.
2.4.3 Accessories
Securement Strip: 14 gauge stainless steel metal bar 2.54 cm 1 inch wide, pre-punched 2.54 cm 1 inch on center for securement.
2.5 COMPOSITE, SELF-ADHERING MEMBRANE SHEETING
Cold applied composite sheet consisting of rubberized asphalt and cross laminated, high density polyethylene film. Not less than 1.5 mm 60 mils minimum thickness is required.
2.5.1 Composite, Self-Adhering Sheeting Performance Requirements
a. Tensile Strength ASTM D412, Die C: 1.6 MPa 250 psi minimum.
b. Ultimate Elongation, ASTM D412, Die C: 200 percent minimum.
c. Water Vapor Transmission, ASTM E96/E96M 26.7 degrees C 80 degrees F Permeance, Procedure B: 5.72 by 10-7 g/Pa.s.m2 0.1 perm maximum.
d. Pliability degrees, ASTM D146/D146M: (180 degrees Bend Over 25 mm 1 Inch Mandrel): No cracks at minus 32 degrees C minus 25 degrees F .
e. Provide test report data for crack bridging ability: Either in accordance with ASTM C1305 as modified for a dry film thickness specified by the manufacturer and conducted at low temperature; or in accordance with a cycling over crack test also conducted for the specified dry film thickness at low temperature. Using either test, verify crack bridging up to 6 mm 1/4 inch without damage to the membrane system.
f. Puncture Resistance, ASTM E154/E154M REV A: 18 kg 40 lb minimum.
SECTION 07 13 53 Page 11
g. Lap Adhesion at Minimum Application Temperature, ASTM D1876 Modified, 880 N/m 5 lbs/in. .
h. Peel Strength, ASTM D903: Modified 1576 N/m 9 lbs/in.
i. Resistance to Hydrostatic Head, ASTM D5385/D5385M : 70 m 231 ft of water.
j. Water Absorption, ASTM D570; 0.1 percent maximum.
2.5.2 Primers
Asphalt composition, ASTM D41/D41M, or synthetic polymer in solvent as recommended by the membrane manufacturer.
2.5.3 Mastics
Polymer modified asphalt in suitable solvent of trowel grade consistency and as recommended by the membrane manufacturer.
2.6 Protection Board
NOTE: Al ways r equi r e pr ot ect i on mat er i al separ at i ng wat er pr oof i ng f r om f i l l mat er i al . Del et e pr ot ect i on boar d opt i on and r equi r e t he pol ymer i c gr i d opt i on f or ear t h cover ed magazi nes or f aci l i t i es wi t h r out i ne gr ound wat er exposur e.
NOTE: Fi ber boar d wi l l not pr ovi de pr ot ect i on af t er i t becomes wet . Do not use bi t umi nous- i mpr egnat ed pr ot ect i on boar d when i n cont act wi t h pol yvi nyl chl or i de ( PVC) , whi ch may be i n composi t e membr anes. Pol yst yr ene i s not compat i bl e wi t h pet r ol eum pr oduct s. The membr ane and pr ot ect i on boar d must be compat i bl e.
[ Provide protection board that is compatible with the waterproofing membrane. Use a minimum 13 mm 1/2 inch thick fir bitumen impregnated board 25 mm 1 inch for polystyrene 3 mm 1/8 inch thick for vertical and 6 mm 1/4 inch for horizontal premolded bituminous protection board as recommended by the manufacturer.
][ Three dimensional, high impact resistant polymeric grid with woven monofilament drainage fabric bonded to the grid.
] PART 3 EXECUTION
NOTE: Do not i nst al l t hi s syst em on t op of wat er l ogged soi l s. Add r equi r ement s f or dr y i ng/ dewat er i ng and wr i t t en ver i f i cat i on of dr yness ( moi st ur e t est i ng) pr i or t o i nst al l at i on of sheet wat er pr oof i ng; coor di nat e wi t h Di v i s i on 31 dewat er i ng r equi r ement s.
SECTION 07 13 53 Page 12
3.1 VERIFICATION OF CONDITIONS
Before starting the work, verify surfaces that must be waterproofed are in satisfactory condition. Notify the Contracting Officer of defects or conditions anticipated to prevent a satisfactory application. Do not start application until defects and conditions have been corrected.
3.2 SURFACE PREPARATION
NOTE: Add a par agr aph t o Sect i on 03 30 00 CAST- I N- PLACE CONCRETE r equi r i ng cur i ng compound cont ai ni ng wax or oi l t o be r emoved pr i or t o appl i cat i on of wat er pr oof i ng.
Ensure surfaces to receive treatment are clean, dry, smooth, and free from deleterious materials and projections. [Thoroughly wet holes, joints, cracks, and voids in [masonry] [concrete] with water and fill with Portland cement mortar, strike flush, and permit to dry.] Cut off high spots or grind smooth. Finish top surfaces of projecting masonry or concrete ledges below grade, except footings, to a steep bevel with Portland cement mortar. Sweep surfaces to receive covering before applying waterproofing to remove dust and foreign matter. Cure concrete by a method compatible with the waterproofing system.
3.3 APPLICATION
NOTE: Del et e r equi r ement s f or cant st r i ps i f cant st r i ps ar e not r equi r ed.
3.3.1 Building Envelope Requirements
Provide a continuous waterproofing system at all material and building transitions. Lap, wrap, fasten and seal products in accordance with manufacturer's printed instructions. Envelope assembly variations are not permitted without written approval from the Contracting Officer's Representative.
3.3.2 General Installation Requirements
Provide sheet waterproofing in accordance with manufacturer's printed installation instructions. Ensure the surface to receive membrane is clean, smooth and dry without surface irregularities; correct deficiencies prior to installation. [Where indicated, mop continuous cant strips in place at vertical and horizontal corners before installing the waterproofing membrane. Do not use untreated wood or wood fiber cants.] When using solvent welding liquid, avoid prolonged contact with skin and breathing of vapor and provide adequate ventilation. Carry waterproofing of horizontal surfaces up abutting vertical surfaces and adhere solid to the substrate. Avoid wrinkles and buckles in applying membrane and joint reinforcement.
3.3.2.1 Non-Self-Adhering Membrane
Unroll membrane and allow to remain flat for at least one-half hour before application. Apply an asphalt concrete primer prior to application of
SECTION 07 13 53 Page 13 asphaltic adhesive. Where solvent adhesive is applied, allow major portion of solvent to evaporate so that bonding adhesive does not stick to a dry finger touching it. Apply elastomeric waterproofing membrane in a full bed of adhesive at a uniform coverage rate in accordance with the membrane manufacturer's printed instructions. [Where membrane on horizontal surfaces are to receive concrete fill, apply adhesive in 100 mm 4 inch wide strips at 600 mm 2 feet on center.] Pull membrane tight without stretching. As soon as adhesive is fully set and dry, recheck lap splices. Where openings or fishmouths appear, reseal and reroll lap splices.
3.3.2.2 Self-Adhering Membrane
Apply composite, self-adhering membrane on surfaces primed at a uniform coverage rate in accordance with membrane manufacturer's printed instructions. Remove release sheet and apply with tacky surface in contact with dried primer.
3.3.2.3 Protection
Protect membrane over horizontal surfaces from traffic during installation. Use only equipment with rubber tires. Provide walkway protection where heavy traffic from other trades is expected. Do not store material on membrane.
3.3.3 Butyl Rubber
Lap sheets at sides and ends a minimum of 150 mm 6 inches over the preceding sheet. Apply lap splicing cement over entire 150 mm 6 inches splice area prior to application of sealant. Make sealant continuous along the entire length of the splice. Maintain a continuous bead of sealant at all membrane splices or as required by the manufacturer.
Provide a tongue and groove cemented splice a minimum of 150 mm 6 inches wide with factory made heat vulcanized seam of not less than 50 mm 2 inches or as required by the manufacturer, when membrane is below water table.
3.3.4 Thermoplastic Membrane (PVC)
Consult with membrane manufacturer prior to grid application. Install
30.48 cm 12 inches wide sub-membrane containment grid as required by manufacturer. Provide the containment grid at intervals across the width and length of the substrate, at the base of all transitions, walls, curbs, penetrations, and at the perimeter of each deck/substrate section. Fully adhere strips to the deck in a full bedding of two-part urethane adhesive. Weld adjacent sheets in accordance with manufacturer's instructions. Hot-air weld all side and end lap joints. Provide lap area a minimum of 7.62 cm 3 inch wide when machine welding, and a minimum of
10.16 cm 4 inch wide when hand welding but not less than recommended by the manufacturer. Orient overlaps with the direction of flow of water.
3.4 COMPOSITE, SELF-ADHERING MEMBRANE
Lap sheets at edges and ends a minimum of 65 mm 2-1/2 inches over the preceding sheet. Provide all side laps a minimum 65 mm 2-1/2 inches and end laps 127 mm 5 inches . Provide self-adhesive, mastic laps in accordance with manufacturer's recommendation. Roll or firmly press to adhere membrane to substrate. Cover corners and joints with two layers of reinforcement by first applying a 300 mm 12 inch width of membrane centered along the axis. Flash drains and projections with a second ply
SECTION 07 13 53 Page 14 of membrane for a distance of 150 mm 6 inches from the drain or projection. Finish exposed, terminated edges of membrane on horizontal or vertical surfaces with a toweled bead of mastic. Apply mastic around edges of membrane, and drains and projections. Apply mastic at end of each work day.
3.5 FLASHING
Flash penetrations through membrane. Seal all penetrations where reinforcing bars penetrate a waterproofing membrane with the appropriate sealant or mastic flashing component. Embed elastomeric membrane in a heavy coat of adhesive, except for self-adhering membrane. Position continuous metal reglets horizontally on footing and vertically on intersecting and connecting walls, and as specified in Section 07 60 00 FLASHING AND SHEET METAL. Metal reglets are to receive exposed edges of membrane waterproofing. Secure membrane into reglets by lead wedges and fill with cement as recommended in writing by manufacturer of waterproofing materials. Counterflash upper edge of membrane waterproofing and protective covering as specified in Section 07 60 00 FLASHING AND
SHEET METAL.
NOTE: Coor di nat e and speci f y f i el d t est pr ot ocol i n accor dance wi t h UFC 3- 110- 03 Roof i ng. El ect r i c f i el d vect or mappi ng ( EFVM) i s r ecommended f or r oof i ng syst ems cover ed by ot her mat er i al s t hat make t hem i naccessi bl e f or subsequent r oof i nspect i ons.
Syst ems t hat woul d benef i t f r om EFVM ar e assembl i es such as veget at i ve, paver , and bal l ast ed r oof s.
EFVM i s not r equi r ed on al l r oof i ng pr oj ect s and due t o cost , may i ncr ease r oof t ot al owner shi p cost .
Eval uat e cost s ver sus benef i t s f or t he pr oj ect and speci f y f i el d t est pr ot ocol accor di ngl y.
3.6 FIELD QUALITY CONTROL
Notify the Contracting Officer 5 working days prior to date of performing tests. Before concealment, cover elastomeric waterproofing on horizontal surfaces over finished spaces with [75][100] mm [3][4] inches of ponded water for 24 hours. Do not add water after start of 24 hour period.
Accurately measure water level at beginning and end of 24 hour period. If water level falls, remove water and inspect waterproofing membrane. Make repairs or replacement as directed, and repeat test. Do not proceed with work that conceals membrane waterproofing before receiving approval and acceptance of the Contracting Officer.
3.7 PROTECTIVE COVERING
After installation has been inspected and approved by the Contracting Officer, apply a protective covering to the membrane waterproofing prior to backfilling. Protect vertical membrane waterproofing with a 13 mm 1/2 inch minimum thickness of asphalt plank; 13 mm 1/2 inch minimum thickness of fiberboard; or 3 mm 1/8 inch minimum thickness of compatible water resistant bitumen type protection board with edges abutting adjacent edges
SECTION 07 13 53 Page 15 and exposed surfaces covered by a taping system recommended by manufacturer of protection board. Cover horizontal membrane waterproofing with similar protection board and Portland cement mortar not less than 20 mm 3/4 inch thick; place uniformly and allow to set before installing subsequent construction.
-- End of Section --
SECTION 07 13 53 Page 16