Exhibit I Security Unit Price List FSL II.xlsx

XLSX spreadsheet 20 KB Posted

Attached to
Huntsville, Alabama Women's Health Clinic Lease
Solicitation number
36C24426R0054
Issued by

About this file

This is a Security Unit Price List (Exhibit I) template for a General Services Administration (GSA) lease opportunity for the Birmingham VA Medical Center in Huntsville, Alabama under Lease Number 36C24426L0008. The spreadsheet is designed for lessors to quote unit prices on security countermeasures and calculate the Building Specific Amortized Capital (BSAC) amount, which represents an estimate of possible security improvements to be determined after final design. The document organizes security requirements across seven main categories: Facility Entrances and Lobby; Interior Government Space; Sites and Exterior of the Building; Security Systems; Structure; Operations and Administration; and Cybersecurity.

Most security requirements are designated as "Priced in Shell" or "Priced in Tenant Improvements" and should not be priced on this document, as these costs are included elsewhere on a TICS form if provided by the Government. Lessor-provided pricing is required only for specific BSAC line items including public space restrictions relative to primary vertical load members, ground floor window locks with intrusion detection system monitoring, secure air intake grilles, security systems design and testing, video surveillance system design and installation, intrusion detection system design and installation, and duress alarm design and installation. The lessor must input unit prices and quantities for each applicable BSAC item, with totals automatically calculated; Government-provided items are noted and excluded from pricing. Lease-specified overhead fees on the BSAC amount can be calculated on the TICS form by transferring the total BSAC costs from this worksheet.

View the file

Other files

Show all 18

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Security Unit Costs

INSTRUCTIONS TO THE LEASING SPECIALISTS: THIS SPREADSHEET REFLECTS THE BASELINE SET OF SECURITY PARAGRAPHS. EACH PARAGRAPH IN THE SECURITY SECTION WILL HAVE A CORRESPONDING LINE. IF THE SECURITY SECTION IS ADJUSTED BY ADDING OR DELETING PARAGRAPHS THE SPREADSHEET MUST BE CHANGED ACCORDINGLY.
EXHIBIT I SECURITY UNIT PRICE LIST (FSL II)
LEASE NUMBER 36C24426L0008
[INSERT DATE]
Birmingham VA Medical Center
Huntsville, AL
To be filled out post-award
The Building Specific Amortized Capital (BSAC) amount under the Lease represents an estimate of the possible countermeasures outlined under the Security Requirements section of the lease. The actual BSAC amount shall be determined after the final design. Using this form, the Lessor shall quote unit prices on all security countermeasures identified in the Lease, as reflected in the final Design Intent Drawings (DIDs) and Construction Documents (CDs). These unit costs shall be subject to further negotiation, prior to issuance of a 'Notice To Proceed' for the security improvements. Refer to 'Security Standards' attachment to the Lease for additional details. Input 'Unit Price' and 'Quantity' figures for BSAC items (light blue) and the total will automatically be calculated for that row. Items designated as 'Priced in Shell', 'Priced in Tenant Improvements', or 'Government Provided' are included on this form to align with the full requirements of the 'Security Standards' attachment, but should not be priced on this document. SHELL and TI costs should be included on a 'TICS' form if one has been provided by the Government. Lease-specified overhead fees on the BSAC amount can likewise be calculated on the TICS form by transferring the BSAC 'Total Costs' calculated at the bottom of this worksheet to the TICS form according to the instructions on that document.
Lease Security Standards SectionUnit PriceQuantityTotal
I.FACILITY ENTRANCES, LOBBY, COMMON AREAS, NON-PUBLIC, AND UTILITY AREAS
A.FACILITY ENTRANCES AND LOBBY
1.EMPLOYEE ACCESS CONTROL AT ENTRANCES (SHELL)Priced in Shell
B.SCREENING REQUIREMENTS
1.ACCOMODATION OF RETAIL/MIXED USE SPACE (SHELL)Priced in Shell
C.COMMON AREAS, NON-PUBLIC, AND UTILITY AREAS
1.PUBLIC RESTROOM ACCESS (SHELL)Priced in Shell
2.SECURING CRITICAL AREAS (SHELL)Priced in Shell
3.VISITOR ACCESS CONTROL (SHELL)Priced in Shell
4.PUBLIC SPACE RESTRICTIONS WITH PRIMARY VERTICAL LOAD MEMBERS$ - 0
4a.RESTRICT CONTACT FROM PUBLIC AREAS WITH PRIMARY VERTICAL LOAD MEMBERS$ - 0
4b.RESTRICT CONTACT FROM MAIL AREAS WITH PRIMARY VERTICAL LOAD MEMBERS$ - 0
II.INTERIOR (GOVERNMENT SPACE)
A.IDENTITY VERIFICATION (SHELL)Priced in Shell
BFORMAL KEY CONTROL PROGRAM (SHELL)Priced in Shell
III.SITES AND EXTERIOR OF THE BUILDING
A.SIGNAGE
1.POSTING OF SIGNAGE IDENTIFYING THE SPACE AS GOVERNMENTAL (SHELL)Priced in Shell
2.POSTING OF REGULATORY SIGNAGE (SHELL)Priced in Shell
B.LANDSCAPING AND ENTRANCES
1.LANDSCAPING REQUIREMENTS (SHELL)Priced in Shell
2.HAZMAT STORAGE (SHELL)Priced in Shell
3.PLACEMENT OF RECEPTACLES, CONTAINERS, AND MAILBOXES (SHELL)Priced in Shell
C.PARKING
1.PUBLIC ACCESS TO GOVERNMENT PARKING AREAS (SHELL)Priced in Shell
IV.SECURITY SYSTEMS
A.SECURITY SYSTEM TESTING & MAINTENANCE CRITERIA$ - 0
B.VIDEO SURVEILLANCE SYSTEM (VSS)
LESSOR PROVIDED DESIGN AND INSTALLATION$ - 0
GOVERNMENT PROVIDED SCOPE, PRODUCT, AND INSTALLATIONGovernment Provided
C.INTRUSION DETECTION SYSTEM
LESSOR PROVIDED DESIGN AND INSTALLATION$ - 0
GOVERNMENT PROVIDED SCOPE, PRODUCT, AND INSTALLATIONGovernment Provided
D.DURESS ALARM
LESSOR PROVIDED DESIGN AND INSTALLATION$ - 0
GOVERNMENT PROVIDED SCOPE, PRODUCT, AND INSTALLATIONGovernment Provided

E. SECURITY SYSTEMS DESIGN $ - 0

V.STRUCTURE
A.WINDOWS
LOCK GROUND FLOOR WINDOWS (BSAC- IDS Monitoring)$ - 0
B.BUILDING SYSTEMS
1.EMERGENCY GENERATOR PROTECTION (T.I.)Priced in Tenant Improvements
2.SECURE AIR INTAKE GRILLES$ - 0
VI.OPERATIONS AND ADMINISTRATION
A.FACILITY SECURITY COMMITTEE (FSC) - (SHELL *)Priced in Shell
B.ACCESS TO BUILDING INFORMATION (SHELL *)Priced in Shell
C.CONSTRUCTION SECURITY PLAN (SHELL)Priced in Shell
VII.CYBERSECURITY (SHELL *)
CYBERSECURITY REQUIREMENTS OUTLINED IN SECTIONS A-C (SHELL *)Priced in Shell
TOTAL COSTS$ - 0

Security Unit Price List (Level II)

REV (08 2021)

&P

Security Unit Price List (Level III) REV (xx 2021) Page #

Security Unit Price List (Level II)

REV (08 2021)

&P

Security Unit Price List (Level II)

REV (OCT 2024)

&P

File details come from the government source that posted it. Updated .